Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.7 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹25.8 L+₹7.0 L (37.1%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹30.3 L+₹11.4 L (60.6%)Rejected-AOC | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically unfit due to ban imposed by CEWC in WLR | |
| 5 | Rejected-Technical | - | Rejected-Technical Technically unfit due to ban imposed by CEPZ in WLR |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
19 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
OUTSOURCING OF SERVICES FOR MANNING OPERATION AND MAINTENANCE OF AC PLANT AND GENERATOR SET AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_406127_1
GE/KC/NIT-61/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹96,000
Yes
13 Mar 2021
23 Dec 2020
21 Jan 2021
23 Dec 2020
19 Jan 2021
7 Jan 2021
23 Dec 2020 - 6 Jan 2021
60 days
Amount
Outsourcing of services for Centralised Air Conditioning Plant chilled water type of tentative capacity 12 TR x 3 Nos (Make : VOLTAS) installed in Missile Shed at AP Birpur with one Referigerator Mechanic per shift, daily round the clock in 3 shifts (8 hours for each shift - first shift - 0600 hrs to 1400 hrs, second shift - 1400 hrs to 2200 hrs, third shift - 2200 hrs to 0600 hrs) for 24 Hours round the clock including sundays and holidays for cooling system in summer season and heating system in winter season, complete all as specified & directed by Eng-in-charge. Notes :- (a). The details of installations and works to be carried out are enumerated in Schedule 'A' Notes. (b). The inside room conditions to be maintanied are as under : Temperature : 22 ± 3º C, Relative Humidity : 50 ± 5%.
(c). Contractor shall employ 01 refrigeration mechanic for AC plant in each shift of 08 hours having ITI certificate from Govt recognized institute or equivalent having 02 Yrs experience in the relative field and familiar with Air Conditioning. (d). Maintenance work will be measured & made under Srl item No. 5 to 44 of BOQ as Supply & fixing/ Material & labour. Preventive maintenance will be carried by the contractor through authorised Engineers of Voltas only. (e). The contractor shall make payment to workers/tradesmen not less than minimum wages as per Regional Labour Commissioner including DA as authorised. (f). Salaries for workers / tradesmen shall be paid through bank on or before 07th of every month and proof of payment of NEFT receipt shall be submitted alongwith RAR and Final Bill.
Outsourcing of servces for Manning and Operation of Power House 11/0.433 KV with one electrician (skilled) and one helper per shift in 3 shifts (8 hours for each shift - first shift - 0600 hrs to 1400 hrs, second shift - 1400 hrs to 2200 hrs, third shift - 2200 hrs to 0600 hrs) for 24 hour round the clock including sundays and holiday including attending telephonic complaints, maintain necessary records and documents as per standard practices including carry out periodical maintenance of installations and day to day maintenance, complete all as specified & directed by Eng-in-charge.
The details of equipments to be handled and maintained are as under:- (a) Transfomer 11/0.433 KV Cap 100 KVA - 01 No (b) 11KV VCB - 01 No (c) Servo Voltage Stabilizer 100KVA -01 No (d) Repair/Replacement of jumper of 11 KV line (e) Repair of blown off HT Fuses (f) Any other part required to operate and maintence of receiving station. (g) HT 11 KV overhead line/Cable (h) Street light / Security light complete area (j) APFC/LT Panel -02 Nos Note : The Contractor shall employ three (03) Electrician (skilled) and three (03) Helpers per day as per above shifts, accordingly duty roster to be prepared and submitted before commencement of each month.
Outsourcing of services for manning and operation of DG Set installed at Missile shed with one operator/FGM (skilled) in 3 shifts (8 hours for each shift - first shift - 0600 hrs to 1400 hrs, second shift - 1400 hrs to 2200 hrs, third shift - 2200 hrs to 0600 hrs) for 24 hour round the clock including sundays and holidays including, attending telephonic complaints, maintain necessary records and documents as per standard practices including carry out periodical maintenance of installations and day to day maintenance, complete all as specified & directed by Eng-in-charge.
The details of equipments to be handled and maintained are as under:- (a) DG set of cap 100 KVA complete with batteries - 01 No (b) Perimeter Security light/street light complete Birpur depot Note : The Contractor shall employ three (03) operator/ FGM per day as per above shifts, accordingly duty roster to be prepared and submitted before commencement of each month.
Notes for Serial Item No 1 to 3 : (a). Operation of DG Sets, Main Switches, AMF Panel, Change Over Switch for Electrical Supply Installations are deemed to be included in the Quoted rates. (b). DG Set will be started immediately after break down/shut down of civil electic supply under initimation to Engr-in-Charge. (c) The contractor shall provide and maintain all the documents such as plant running record book, installation chart, daily records i.e log sheets, duty roaster, attendance register etc and cost thereof shall deemed to be included in rates quoted for the above items. The daily record shall be sign by the contractor or his authorised rep and should be submitted to the JE concern on daily bases. (d) Contractor shall submit attendance register, duly completed in all respect to Engr-in-Charge every month.
(e) Unless until releiver report for the duty, staff on duty will not leave the installation without proper handing taking over of the same. In case the operator is found absent from duty at AC Plant/ DG Set / Installation or in case of failure of Electric supply due to any reason the Penal recovery @ Rs.1000/- per shift shall be made from the contractor dues. The decision of the Accepting Officer in this regard shall be final and binding. (f) The contractor shall keep the installation and its surronding neat and clean by cutting the grass, bushes etc and remove debries from installation as directed by the Eng-in-charge with in the fencing area of the installation and the cost on account of the same shall be inclusive of the rate quoted by the contractor. (g) No payment will be made to the contractor if he fails to submit proof of payment of wages in bank account.
(h). Contractor shall make payment to the employees as per minimum wages prescribed by the Dept of labour commissinor. (j) The contractor should provide skilled tradesmen having sufficient knowledge/ experience in the respective field. Experience certificate & qualification certificate as mentioned here-in-before is to be produced to Engr-in Charge at the time of commencement of the work. (k). Contractor shall provide uniform and I-card to each tradesmen to maintain the identity of operating staff employed by the contractor. (l). Contractor shall ensure insurance of each person employed on duty .
(m). Contractor should ensure that his operating staff has experience of handling the DG Set, Pump, Starter, AC plants etc. The contractor should ensure that his operating staff shall operate pumpset/ Lifts/ Security lights on DG Set in case of main failure during supply hours. The details of running hours of DG Set should be entered in daily Log book and should be submitted to concered JE. The DG Set shall be checked and test run daily twice in morning hours and evening hours as directed by Engineer-in-Charge. (n) Contractor should ensure that his operating staff should check equipments as mentioned in respective Sch 'A' items on daily basis and inform the concerned JE incarge in case of any leakage/defect arises. (o). Contractor should ensure that in case of any loss/damage of Govt property occours due to negligence of his employed operating staff it will be the responsibility of the contractor to made good loss/damage at his own cost and arrangement.
(p). FGM (skilled)/ Electrician (skilled)/ Lift Operator (Skilled Technician) shall be of Matric & ITI passed with having training certificate in relevent trade not less than two year shall be employed for each shift. (q). It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen/ FGM (skilled)/ operator etc intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/ State Govt/ Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable.
(r). Monthly wages shall be paid by the Contractor to the workers/labours only once proof of stutory deductions in favour of workers/labours is submitted by the contractor to the Engineer in Charge. The Contractor will be required to submit copy of valid labour license from the labour commissioner within 15 days of commencement of contract. If the contractor fail to submit the same the within stipulated period, the contract shall liable to be cancelled and the performance security of the firm shall be forfeited accordingly as per rule in vouge. (s). In case of requirement, tradesmen/ operator etc provided for one area /station / installation may be utilised in other areas/station/installations under GE Kaluchak at the discreation of the Engineer-in-charge without any extra cost to department. (t) . The firm/ contractor shall be solely and fully responsible to his reprsentative/ personal for any accident/ damage during maintenance/ operation/ health related liabilities/ compensation, penelty etc on this account.
(u). T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost. (v). Rate quoted shall be deemed to include for restoration of jumpers, HT fuses,using existing resources during short circuits/ breakdown due to wind/rain or in normal conditions in the premises of Birpur area to restore the electric supply for incoming and outgoing feeders. (w). Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of pump and motors, filteration plant, chemical dosing plant and as directed by Engr-in-charge. (x). Shift Operator/ FGM/ Electrician/ Helper/ Lift operator (Technician) (reliever) etc shall neither leave the installations without prior permission of JE/ Engineer-in-Charge & proper handing/taking over to the next operator/FGM etc.
(y). Two pairs of uniform with name plate of tradesmen & firm and shoes shall be provided to each operator by the contractor. (z). Cleaning of complete lift cabin, Machine Room, DG Room, filling fuel (Diesel) in DG sets, greasing, tightening of nuts, bolts will be carried out by the operator/ FGM/ electrician/ Lift technician employed by the Contractor. (aa). First Aid box will be provided by contractor at each installation. (ab). Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. No other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates.
(ac). Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor. (ad). The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (ae). Duty roster for detailement of operators / FGM (skilled) shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation.
(af). The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of pump and motors for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (ag). For any damage to the installations due to negligence of operator / FGM such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (ah). Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
MAINTENANCE WORK Dismantling of totally damaged portion of the exposed duct insulation consisting of sand cement plaster chicken wire mesh glasswool etc and disposing of the same within 100mtrs, complete all as specified & directed by Engineer-in-Charge.
Scrubbing of bare GI duct with steel wire brushes ,emery cloth for removing stuck material iron oxides etc and dusting with air blower to make the surface clean, complete all as specified & directed by Engineer-in-Charge.
Rubber/ metal based synthetic adhesive to the so cleaned bare duct and the rubber insulation sheets with brushes including applying adhesive on each surface as per requirement at site, complete all as specified & directed by Engineer-in-Charge.
Nitrile rubber insulation 25mm thick with Alum foil facing as UV protection, cut to size as per duct sizes including covering all longitudinal/ transverse joints with 500 wide alum tape, complete all as specified & directed by Engineer-in-Charge.
Routine checking of complete central AC plant of 3 x 12 TR capacity as required during the contract period, fault detection by OEM/authorised partner of OEM with whom MOU stands signed for smooth functioning of the plant as well as for uninterrupted running all as required at site, complete all as specified & directed by Engineer-in-Charge.
Supply and topping of chiller/ compressor unit (12TR AC Plant) with R-407C refrigerant including leak testing and necessary associated repair works, complete all as specified & directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of microprocessor controllers with scanners/ under voltage/ over voltage protections for chillers including caliberation/ settings as per the requirement of the system of chiller controller for proper safeties like under voltage, overvoltage, low pressure and high pressure complete including taking down old unserviceable controllers, complete all as specified & directed by Engineer-in-Charge. Make: As per OEM
Pressure transducers for suction pressure of compressors including taking down old unserviceable and testing, complete all as specified & directed by Engineer-in-Charge. Make. Danfoss
Pressure transducers for discharge pressure of compressors including taking down old unserviceable and testing, complete all as specified & directed by Engineer-in-Charge. Make. Danfoss
Complete overhauling of Delta cooling tower by chemical cleaning of sump, dismantling and servicing of cooling tower strainer, dismantling of cooling tower motor and fan and sprinkaler assembly, descaling of sprinkler pipes and adjustment of sprinkler speed and refitting of motor and fan assembly after satisfactory operation including descaler and replacement of PVC honeycomb fills, complete all as specified & directed by Engineer-in-Charge.
Servicing of condensor water pumps including replacement of impellors and seals, complete all as specified & directed by Engineer-in-Charge.
Servicing of chilled water circulations pumps including replacement of impellors and seals, complete all as specified & directed by Engineer-in-Charge.
Flow switch including dismantling of old unserviceable condensor pipeline flow switch, complete all as specified & directed by Engineer-in-Charge. Make: CR/ Honeywell or equivalent
Non return valve 50 mm for pump, conforming to relevant IS with jointing materials including taking down old unserviceable valve, complete all as specified & directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of mixing/ diverting valve with actuator and transformer complete for maintaining inside temperature complete including taking down old unserviceable mixing valve, complete all as specified & directed by Engineer-in-Charge.
Prefilters (10 microns) in the AHU complete including taking down old unserviceable prefilters, complete all as specified & directed by Engineer-in-Charge. Make: Thermadyne/ Meckmark/ Dyna
Servicing of AHU cooling coil including chemical cleaning with OEM recommended chemical 'scalefoe', complete all as specified & directed by Engineer-in-Charge.
Y- strainer for chilled water and condensor water lines complete including taking down old unserviceable Y strainer, complete all as specified & directed by Engineer-in-Charge. Make: Castle
Disconnecting the electric connections of the electric motor 2 HP of the cooling tower blower, taking out the old unserviceable winding wire, cleaning the slots for rewinding, rewinding the electric motor 3 Phase, 415 volts with existing size of super enamelled copper winding wire including allied materials like cotton tapes, glass sleeves, varnishing and assembling the complete motor and testing, complete all as specified & directed by Engineer-in-Charge.
Disconnecting the electric connections of the electric motor 10 HP of the AHU blower, taking out the old unserviceable winding wire, cleaning the slots for rewinding, rewinding the electric motor 3 Phase, 415 volts with existing size of super enamelled copper winding wire including allied materials like cotton tapes, glass sleeves, varnishing and assembling the complete motor and testing, complete all as specified & directed by Engineer-in-Charge.
Descaling of condensors with 'scalefoe' 100 chemical by pressure pump, opening of condensor head and rodding with nylon brushes including fixing new gasket, condensors covers and refitting with covers, complete all as specified & directed by Engineer-in-Charge.
V-Belt as per existing for AHU including taking down old unserviceable V-Belt, complete all as specified & directed by Engineer-in-Charge. Make : Fenner / Unigrip
Start push button assembly, complete all as specified & directed by Engineer-in-Charge. Make: L&T/ BCH/ C&S
Stop push button assembly, complete all as specified & directed by Engineer-in-Charge. Make: L&T/ BCH/ C&S
Water pressure gauge 100mm range ( 0 to 75psi) including taking down old unserviceable gauge, complete all as specified & directed by Engineer-in-Charge. Make: Guru
Temperature gauge stem type including taking down old unserviceable gauge, complete all as specified & directed by Engineer-in-Charge.
MCB, triple pole, 63 Amps, AC, 415v, 50Hz, breaking capacity 10 KA, C-series including taking down old unserviceable MCB, complete all as specified & directed.
MCB, triple pole, 32 Amps, AC, 415v, 50Hz, breaking capacity 10 KA, C-series including taking down old unserviceable MCB, complete all as specified & directed.
MCCB of capacity 100 Amps, 3 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 100 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, including taking down old unserviceable MCCB, complete all as specified & directed.
Contactor, triple pole, 440 volts 4 KW, 20Amps including taking down old unserviceable contactor, complete all as specified & directed. Make :Schneider/ Siemens/ L&T/ Legrand/ ABB
Contactor, triple pole, 440 volts 15 KW, 32Amps including taking down old unserviceable contactor, complete all as specified & directed. Make :Schneider/ Siemens/ L&T/ Legrand/ ABB
Contactor, triple pole, 440 volts 22 KW, 40Amps including taking down old unserviceable contactor, complete all as specified & directed. Make :Schneider/ Siemens/ L&T/ Legrand/ ABB
Voltmeter (0-500V) digital flush type 96mm, square type including taking down old unserviceable voltmeter, complete all as specified & directed. Make: AE/ Schneider/ Legrand/ L&T/ C&S
Ammeter (0-60A) digital flush type 96mm square type including taking down old unserviceable ammeter, complete all as specified & directed. Make: AE/ Schneider/ Legrand/ L&T/ C&S
Ammeter (0-100A) digital flush type 96mm square type including taking down old unserviceable ammeter, complete all as specified & directed. Make: AE/ Schneider/ Legrand/ L&T/ C&S
Over load relay with range (12- 18) Amps including taking down old unserviceable relay, complete all as specified & directed. Make: AE/ Schneider/ Legrand/ L&T/ C&S
Over load relay with range (07- 10) Amps including taking down old unserviceable relay, complete all as specified & directed. Make: AE/ Schneider/ Legrand/ L&T/ C&S
B-check general servicing by authorised rep of OEM of DG set of capacity 100 KVA, silent type including replacement of old unserviceable engine oil, oil filter, diesel filter, air filter, bypass filter, rubber parts, fuel pipeline, cleaning of radiator with chemical after draining out engine/lubricant oil ,coolant flushing and cleaning of oil chamber after opening of tappet cover/ top cover tappet clearance setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/chamber gasket at the servicing and other work comes under B-check service as mentioned in B-check by the manufacturer, complete all as specified & directed by Engineer-in-Charge. Make of spares :Kirloskar
Supply, installation, testing and commissioning of maintenance free battery, 12V, 180AH including dismantling of old unserviceable battery, complete all as specified & directed. Make : Exide / Amaron/ Standard/ Furkkava
M/S SALARIA ASSOCIATES
M/S ASHOK KUMAR SURI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .