Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.4 L+₹2.5 L (8.78%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹32.7 L+₹3.8 L (13.1%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.6 L+₹6.7 L (23.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹38.0 L+₹9.1 L (31.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
17 Feb 2021, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
Electrical Maintenance of KLP under AGE E/M at Mil Stn Bikaner under GE (N) Bikaner
2021_MES_414141_1
GE (N) BKN-Token/58/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (N) Bikaner
Class D Category b (i)
8 documents required · 8 mandatory
₹500
GE(N) Bikaner
₹78,000
Yes
21 Jul 2021
19 Jan 2021
19 Feb 2021
19 Jan 2021
17 Feb 2021
3 Feb 2021
Amount
Taking down ceiling fan for repair/serviceing (i.e. winding/ greasing/oiling etc.), 1200/1400 mm sweep of any make and any type model, sealing cable end with tape, dismantling the blades , removing fan and deposite the blades/motor to store for repairing/serviceing complete all as specefied and as directed by Engineer in charge.
Hanging only ceiling fan and connection up the point including provision of cable from ceiling rose to fan complete all as specefied and as directed by Engineer in charge. (Note: For the purpose of payment, the wire using ceiling rose to fan for connection shall be measured and paid seperately in approprite item and nothing extra pay for this item)
Re-winding of ceiling fan new model of size 1200 mm sweep with super enameled copper winding wire of guage as per existing size No of wire confirming to IS including varnishing the motor windings with best quality varnish reassembling and testing complete all as specified and as directed by Engr-in-Charge
Ditto all as per item No 3 here in above but new model ceiling fan of size 1400 mm sweep complete all as specefied and as directed by Engineer in charge.
S&F in replacement of ball bearing of size/No. 6201 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NCB/SKF)
S&F in replacement of ball bearing of size/No. 6202 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NCB/SKF)
S&F in replacement of ball bearing of size/No. 6203 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NCB/SKF)
S&F in replacement of brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement of broken bottom cover (bowl) of PVC suitable for ceiling fan of any make and model complete all as specefied and as directed by Engineer in charge.(Make:bajaj/Kessels)
S&F in replacement of shaft for ceiling fan as per existing size and shape complete all as specefied and as directed by Engineer in charge.
Taking down and dismantling of exhaust fan 225mm/300mm/375mm/450mm sweep of any make and model, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully serviceable condition including replacing the defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete to the satisfaction of Engineer in charge.
Re-winding of exhaust fan 225mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish, reassembling and testing complete all as specefied and as directed by Engineer in charge. (Make:Milan/Atlas/Chetak)
Ditto all as per item No 12 here in above but of size 300mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but of size 375mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but of size 450mm sweep complete all as specefied and as directed by Engineer in charge.
S&F in replacement of blades for size of exhaust fan 225mm dully approved by GE complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 16 here in above but size of exhuast fan 300mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 16 here in above but size of exhuast fan 375mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 16 here in above but size of exhuast fan 450mm sweep complete all as specefied and as directed by Engineer in charge.
S & F in replacement of condenser 04 MFD confirming to IS complete all as specefied and as directed by Engineer in charge. Make : Epcos/Bajaj/Asian
S & F in replacement of MS shaft for exhaust fan as per existing size and shape complete all as specefied and as directed by Engineer in charge.
S&F in replacement of MS back side cover for Exhaust fan of any sweep, size and make complete all as specefied and as directed by Engineer in charge.
Fixing only Exhaust fan and connection up the point including provision of cable from ceiling rose to fan complete all as specefied and as directed by Engineer in charge. (Note: For the purpose of payment, the wire using ceiling rose to fan for connection shall be measured and paid seperately in approprite item of this Schedule)
Taking down and dismantling of cabin/wall mounting fan of any size/make/sweep, opening the cover separating the motor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective parts, fleaxible wire of size 23/0.0076, oiling/greasing the fan and re-assembling the fan, testing and refixing the fan complete all as specefied and as directed by Engineer in charge.
Re-winding the cabin/wall mounting fan with and including super enamelled copper winding wire of existing specification, gauge and weight including insulating materials and varnishing the motor windings with best quality varnish, reassembling and testing complete all as specefied and as directed by Engineer in charge.
S&F in replacement of brass bush suitable for cabin/wall mounting fan of any make/model confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement of push button cover of plastic suitable for cabin/wall mounting fan of any make/model with lock nut confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement down rod 30 cm long suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed by Engineer in charge.
S&F in replacement D Clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed by Engineer in charge.
S&F PVC Canopies (Set of two) for ceiling fan of size 1200/1400 mm sweep as required at site and complete all as specefied and as directed by Engineer in charge
S&Fin replacement condenser 2.5 MFD confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: Tibcon/Orient/Epcos
S&F in replacement of flexible wire of size 23/0.0076 stranded copper conductor complete all as specefied and as directed by Engineer in charge.Make : Anchor / Plaza/Finolex
S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement complete all as specefied and as directed by Engineer in charge. Make : Anchor/Leader/SSK
M & L in replacement fan blade suitable for 1200mm sweep ceiling fan of any make complete all as specefied and as directed by Engineer in charge.
M & L in replacement fan blade suitable for 1400mm sweep ceiling fan of any make complete all as specefied and as directed by Engineer in charge.
Taking down old u/s electric meter with and including old cable from the switch board after disconnecting all electrical connections and depositing in MES store yard complete all as specified as directed by Engineer-in-Charge.
S&F temper proof electronic static watt hour energy meter LCD display of class 1.0 accuracy conforming to IS -13779 and CBIP Technical Report 88 and IEC 62052-11, IEC 62052-21, suitable for single phase system with optical port, 10-Amps (Basic) and 60 Amps (Maximum) capacity, duly encased in PVC housing with and including multi-stranded PVC insulated copper conductor cable/wire of size 6 sq mm cross-sectional area with bottle lugs for connections and connecting complete all as specified as directed by Engineer-in-Charge.
Supply and fixing temper proof electronic static watt hour energy meter LCD display of class 1.0 accuracy conforming to IS -13779 and CBIP Technical Report 88 and IEC 62052-11, IEC 62052-21, suitable for Three phase system with optical port, -60Amps (Basic) and 100 Amps (Maximum) capacity, duly encased in PVC housing with and including multi-stranded PVC insulated copper conductor cable/wire of size 10 sq mm cross-sectional area with bottle lugs for connections and connecting complete all as specified as directed by Engineer-in-Charge.Make . HPL
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engr-in-Charge.
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in PVC concealed/Cassing capping/ conduit Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in and including sunken box covered with and including 3 mm thick bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Make of cables :Havell's/Paragon/Nicco/L&T.Make of PVC Conduit : Polycab/Supreme/Modi/Finolex/Prince/Precision
All as per item No 41 here-in-before but in existing conduit cable of 1.5 Sq mm complete all as specified and directed by Engr-In-charge.
All as per item No 41 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 41 here-in-before but socket point on the independent board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 41 here-in-before but cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board including provision of 2.5 Sqmm PVC insulatred unshethed multistranded copper conductor as earth wire
All as per item No 41 here-in-before but in existing conduit cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board
All as per item No 41 here-in-before but in existing conduit cable of 4 Sq mm for 25 Amp switch socket outlet on independent board
All as per item No 41 here-in-before but one light point controlled by two 02 - way switch complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED T5 Batten lightening fixture, energy efficent 18/20 Watt ( 4 feet) complete all as specified and directed by engineer-in-charge make:-CG/ Havells/Phillips
S&F in replacement LED T5 Batten lightening fixture, energy efficent 9/10 Watt ( 2 feet) complete all as specified and directed by engineer-in-charge make:-CG/ Havells/Phillips
Supply & fix LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished > 0.9 complete all as specified and directed by Engineer-in-charge. Cat Part no. SSk-BH-9W in make Syska / havell's / Phillips.
S&F in replacment LED PLL Lamp (Retro Fit) two pin 9/11/13/18 Watt Make Syska - SSK-PLL-8W-N or equivalent in make phillips/Polycab/havells/CG
S&F in replacement Recessed mounting LED 2x2 luminaire type BCTBLR 36W ZTN NW in make Bajaj or equivelent in CG / Phillips / GE / Wipro / Havell's
S&F LED 2x20W NW interconnectable luminaires for aesthetically appealing downlight application complete all as per specified and directed by Engr-in-Charge Cat Part No. 112114 in make Bajaj and or equivalent
S&F LED 2x40W NW interconnectable luminaires for aesthetically appealing downlight application complete all as per specified and directed by Engr-in-Charge Cat Part No. 112205 in make Bajaj and or equivalent
S&F Recessed mounting LED 4x1 luminaire type Cat Part No. 112665 in make : make Bajaj or equivelent in CG / Phillips / GE / Wipro / Havell's
S&F in replacement 1000 halogen Planoconvex spot light complete with 100 W halogen Bipin T-11 lamp spherical anodised reflector imported socket 150mm dia planoconvex lens, bottom sliding knob , yoke, colour frame & suitable clamp type SL-35H or Equivalent as approved. Make of fitting : Modern stage service, PR Lighting inc, Delhi Light & Music Center Jia lighting & Audio Equipment Co, Illumination india, Make of Lamp CG/ Phillips /Bajaj
S&F in replacement 1000W halogen profile light consisting of 2 nos, 150mm dia PC lenses, imported socket ellipsoidal anodised aluminium reflectro, 1000W halogen Bipin T-11 lamp, yoke colour frame & Suitable clamp, type : Modern - 220 or equivalent as approved Make of fitting . Modern stage service PR lighting Inc, Delhi Light & Music center, Jia lighting & Audio Equipments Co Illuminatio India Make of lamp : CG , Phillips,Bajaj
S&F 500W halogen flood light for cyclorama . Make of fittings : DTS , Italy , Modern Stage Service PR lighting Inc, Delhi Light & Music center Jia Lighting & Audio Enuipments Co, Illumination India, Make of Lamp. CG,Phillips,Bajaj
S&F 1000W halogen light with mash & bamdoor consisting of 2 nos singhle contect compressible holders yoke, 1000W halogen tube & suitable clamp type : HL-44 or Equivalent as approved Make of Fitting. Modern stage servcie PR lighting Ino , Delhi light & Music Center Jia , Lighting & Audio Equipments Co, Illumination India make of Lamp : CG, Phillips , Bajaj
Supply and fix in replacement of existing U/s circular light of any wattage, any make, from any hight and fixed LED commercial down light -round Recess mounting bakelit LED down light, round PDC aluminium body with outer frame, separate driver with 6000K of capacity 15 watt as per polycab cat part no PCGLRD 01 15 16 or equivalent make in CG, Bajaj, Havells
Supply and fix in replacement of existing FPL light fitting 3 x 36 watt of any make and fix with LED slim panel Edgelit LED slim panel having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser separate HPF driver. suitable for arm strong and grid ceiling of size 2 x2 CCT 6000 K of capacity 40 watt as per polycab cat part no PCGLP ECO 2x2 40 60 or equivalent make in CG, Bajaj, Havells
S&F in replacement of existing foot light with LED foot light of capacity 1 x5 watt 230 volt indoor recess mounting foot light with all accessories
S&F in replacement of existing U/s cove light with 9 watt LED light fitting mounting in cove at the ceiling complete with all accessories.
S&F in replacement of existing high bay light /flood light fitting of any capacity and make with the LED Beam/flood lights of capacity 100 watt as per cat part no SSK-BLS-COB -100w of syska LED or equivalent make in CG, Bajaj, Havells
Suppy and Fixing in replacement LED based security light, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 2500 lumens and maximum system wattage 25 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make SYSKA/CG/C&S/Bajaj/Havells
S&F in replacement lamp holder PVC/Poly carbonate body with back plate complete all as specified and as directed by Engineer-in-Charge.Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement switch piano flush type, Single pole 5 Amps, one way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement of switch piano flush type, Single pole 15 Amps, one way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement of socket outlet flush type, 3/5 pin, 5/15 Amps, complete all as specified and as directed by Engineer-in-Charge. Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement of socket outlet flush type, 3 pin, 5 Amps, complete all as specified and as directed by Engineer-in-Charge. Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement Switch piano flush type, Single pole 5 Amps, two way ISI marked, complete all as specified and as directed by Engineer-in-Charge Make : Anchor/ Legrand/Wipro/Havells
S&F in replacement switch socket combination 2 in 1, 5 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
S&F in replacement Switch socket combination 5 in 1, 5/16 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
S&F in replacement Modular switch 1 way 6A, 1 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement Modular switch 1 way 16A, 1 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement Socket, 6A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement Socket, 16A - 2/3 pin combined 2 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement Fan step regulator, 120W - 2 module complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement White cover plate with frame, 1 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement White cover plate with frame, 2 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement White cover plate with frame, 3 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement White cover plate with frame, 4 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement White cover plate with frame, 6 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement White cover plate with frame, 8 modul complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F Bell push flush type, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge
S&F Bell Buzzer, Ding Dong AC 230 Volts, single pole ISI marked, complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of PVC connector, ISI marked complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Tv socket flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Telephone socket flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge
Supply and Fixing MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Legrand,ABB,Schneider
Supply and Fixing MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- ABB,Legrand,Schneider
Supply and Fixing in replacement MCB 63 Amps, 440 Volt AC supply Triple pole with neutral(TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ABB/Schneider
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make -L&T ( Exora series)/Schneider/ legrand/Schnedier/GE /English Elect Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 12 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make -L&T ( Exora series)/Schneider/ legrand/Schnedier/GE /English Elect Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,TPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make -L&T ( Exora series)/Schneider/ legrand/Schnedier/GE /English Elect Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 415 volts with 200 Amps rated bus bar, load line DB's are fittied with bus bar nutural links blank plates TPN vertical load line 4 ways suitable for TP/FP 'A' frame MCCB,includeing 100 Amps MCCB -01Nos ,MCB SPN 32 -04 Nos MCB SP as per required, complete all as specified and as directed by Engineer-in-Charge. Make - Havells or equivelent Legrand/ GE/Seimens/L&T/Schneider/Indo Asian/C & S/ABB/BCH/HPL Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 06 to 32 Amps capacity complete all as specified and directed by Engr-in-charge Cat Part No 607841 in Make Legrand or equivalent in schneider/Seimens/L&T
Sub main wiring in PVC casing capping/conduit/Surface with 2 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping all as specified and as directed by Engineer-in-Charge.(Note two run of 10 sqmm and one run of 6 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in PVC casing capping/conduit/Surface with 2 single core 04 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 2.5 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping all as specified and as directed by Engineer-in-Charge.(Note two run of 4 sqmm and one run of 2.5 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in Existing PVC concealed conduit with 2 single core 4 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 2.5 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note two run of 4 sqmm and one run of 2.5 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in Existing PVC Surface conduit with 2 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note two run of 10 sqmm and one run of 6 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in Existing PVC Concealed conduit with 4 single core 25 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with two earth wire of 16 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note four run of 25 sqmm and two run of 16 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in Existing PVC Concealed conduit with 4 single core 16 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with two earth wire of 10 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note four run of 16 sqmm and two run of 10 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in Existing PVC Concealed conduit with 4 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with two earth wire of 6 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note four run of 10 sqmm and two run of 6 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in Existing PVC Concealed conduit with 4 single core 6 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with two earth wire of 4 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note four run of 6 sqmm and two run of 4 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Taking down of any size unserviceable compressor 01 ton capacity walk in cooler of any make and supply & fixing new compressor 01TR capacity of walk in cooler including gas charging , fan blade , fan motor any size, evaporator unit , condenser unit with connecting accessories etc. and recommended by existing O.E.M.
BALAJI PROJECTS
BIDAWAT ENTERPRISES
K.T. Construction Company
JASNATH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .