| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Lowest Accepted Bidder | |
| 2 | L2₹22.3 L+₹43,639 (2.00%)Rejected-AOC NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L2 | Rejected-AOC Lowest Accepted Bidder is M/S Pareek and Company | |
| 3 | L3₹22.8 L+₹92,968 (4.26%)Rejected-AOC | L3 | Rejected-AOC Lowest Accepted Bidder is M/S Pareek and Company | |
| 4 | L4₹23.4 L+₹1.6 L (7.37%)Rejected-AOC | L4 | Rejected-AOC Lowest Accepted Bidder is M/S Pareek and Company | |
| 5 | L5₹23.6 L+₹1.8 L (8.07%)Rejected-AOC | L5 | Rejected-AOC Lowest Accepted Bidder is M/S Pareek and Company |
Tender Value
₹32.9 L
EMD Value
₹65,800
Closing Date
13 Oct 2020, 6:00 pmClosed
CWE BIKANER
CWE BIKANER, MIL STN BIKANER 334001
Special repair to certain Store Shed at GE (Engr Park) at Suratgarh Military Station
2020_MES_377799_1
CWE BKN TOKEN NO 21 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
150 days
SURATGARH
All contractors enlisted with MES in Class D and above and category a(i) The firms not enlisted with MES shall meet the enlistment criteria of D class MES contractors and category a(i)
7 documents required · 7 mandatory
₹500
GE (A) SURATGARH
₹65,800
Yes
21 Nov 2020
15 Sept 2020
15 Oct 2020
15 Sept 2020
13 Oct 2020
1 Oct 2020
15 Sept 2020 - 24 Sept 2020
Amount
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roof coverings etc including ridges complete all as specified and as directed.
Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each, complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good disturbed surfaces complete all as specified and as directed.
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3, exc half brick & not exc one brick (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall) complete all as specified & as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel (ISI marked) including welding to angle iron frame where required complete all as specified and as directed.
S&F 150 mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified and as directed.
S&F mild steel pressed handle, 125 mm size, oval type, stove enameled black complete all as specified and as directed.
S&F 300 mm long mild steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified & as directed.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified & as directed.
S&F mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates, wind ties, etc. conforming to Grade E-250 quality `A’ complete all as specified and as directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ complete all as specified and as directed.
Supply & fixing steel rolling shutters, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete, gear operated type with bevel gear box and crank handle, thickness of laths 1.00mm, fixed in repairs, complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cooler stand, door frame / chowkat and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed.
S&F mild steel holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Grade E-165 (Fe 290) including necessary welding etc. and fixed in position complete all as specified & as directed.
S&F factory made steel window with side hung shutters including box type hinges with steel handles and peg stay with glazing bars dovetailed or welded complete all as specified & as directed.
S&F factory made steel window with side hung shutters including box type hinges with steel handles and peg stay without glazing bars dovetailed or welded complete all as specified & as directed.
S&F Pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
S&F Pre-painted galvalume aluminum zinc coating Plain steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/ridge/fascia/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
Supply and fixing 2 mm thick transparent fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall etc complete all as specified & as directed.
M&L for 100 mm thick PCC (1:2:4) type B2 using 40 mm graded crushed stone aggregate as in flooring, ramp, etc, surface finished fair and even, complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring, finished even and smooth with using extra cement complete all as specified & as directed.
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement complete all as specified & as directed. Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall & applying three coats of cement base paint in camouflaging pattern (using number of colours) of approved shades/tints over a coat of alkali resistant priming paint complete all as specified and as directed. Note : Camouflaging pattern shall be as approved by GE (workmanship as well as shades/tints of paint).
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint in camouflaging pattern (using number of colours) of approved shades/tints over a coat of alkali resistant priming paint complete all as specified and as directed. Note : Camouflaging pattern shall be as approved by GE (workmanship as well as shades/tints of paint).
Hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for preparation of steel and iron surfaces of any description already having shop coat of primer over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint complete all as specified & as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, top sheet covers, fan regulators, etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC surface conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, junction boxes, junction covers, etc all as per IS, terminated in existing steel terminal boxes for mounting fittings like switches, sockets, regulators etc with and including new 3mm thick phenolic laminated sheet top cover fixed with brass screws & cup washers, complete all as specified and as directed.
All as per serial item No. 41 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch socket combination, 2 in 1, 5 Amps, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F 12 Watt LED Bulb (Non-dimmable) of Standard / Universal size, Base - B22, Power Factor > 0.90, Lamp Efficiency > 80%,, Color Temperature - 6500 K, Lumen output - 950 lm, Colour Rendering Index (CRI) > 70, Warm white (WW) / Cool Day Light (CDL), 230 V, 50 Hz AC, ISI marked, complete all as specified and as directed.
S&F energy efficient decorative ultra slim LED light fitting, 1x18 Watt, 230 Volts, Day Cool light, batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, fixed in repairs, complete all as specified and as directed. Make : Havells Cat Part No. LUMILINEBS18WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, fixed in repairs, complete all as specified and as directed. Make : Havells Cat Part No. RUGBYNEONFT10WLED860SSYM TOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 30 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 40 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 45 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 4600 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based Flood light fitting, 120 Watt with & including LED lamp, housing made up of LM6 pressure epoxy powder coated die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 105 lumens per watt and viewing angle of 120 degree to ensure better uniformity, a minimum system lumen output of not less than 12600 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, fixed in repairs, complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, laying, jointing and testing LT XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :- (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps. Note :- Excavation & earthwork shall be measured & paid for separately.
M/S GODARA CONSTRUCTION CO.
S.K BUILDERS AND ENGINEERS
GARG ENTERPRISES
AK CONSTRUCTION
SHIVA BUILDERS
Gupta Suppliers
J and K constructions company
H S BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .