Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.9 LAccepted-AOC | 1 | Accepted-AOC being lowest | |
| 2 | 2₹10.8 L+₹91,144 (9.25%)Rejected-Finance | 2 | Rejected-Finance being not lowest | |
| 3 | 3₹12.1 L+₹2.3 L (22.9%)Rejected-Finance | 3 | Rejected-Finance being not lowest |
Tender Value
₹9.5 L
EMD Value
₹19,040
Closing Date
12 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF JAIPUR
AGE I AF JAIPUR AMER ROAD OPP JALMAHAL
PROVN OF ANTI - SUICIDE FAN RODS AND POWER SOCKET IN SMQS AT AF STATION JAIPUR
2022_MES_544622_1
8404/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I AIR FORCE JAIPUR
enlisted with MES in Class E and above and category b (I)
8 documents required · 8 mandatory
₹500
AGE I AF JAIPUR
₹19,040
Yes
28 Sept 2022
11 Aug 2022
15 Sept 2022
11 Aug 2022
12 Sept 2022
29 Aug 2022
11 Aug 2022 - 22 Aug 2022
Amount
Taking down existing ceiling fan complete from ceiling including connection, down rod, canopy, nut bolt washer complete and fan rod put in safe custody in MES store yard complete all as specified & directed.
Supply & fix anti sucide fan rod(15'') white ,MS pipe zinc plated,19mm OD,1.8+/-0.05 mm thick,spring set grade 3 carbon steel material zinc plated,MSME tested for,performance test and opening at impact load of 22 KG+ and 'spring hidden in the pipe' will expand to about 1 mtr or more, including fixing/hanging of fans taking down against item No 1, complete all as specified and directed. Make-Gold Life or any other equivalent as approved by Engineer-in-charge.
M&L for point wiring with PVC insulated multi stranded cable with copper conductor of size 1.5 Sq mm single core 650/1100 volts grade ISI mark drawn through PVC casing capping including necessary accessories like bends, tees, elbow, etc fixed on wall/ceiling including second class hard wooden board /sunken type MS box of suitable size with plastic laminated white colored sheet top cover 3 mm thick including 1.5 Sq mm PVC insulated copper conductor earth continuity wire for One 3 pin socket out let 5 Amps on the independent board complete all as specified and directed.
M&L for point wiring with PVC insulated multi stranded cable with copper conductor of size 2.5 Sq mm single core 1100 volts grade ISI mark drawn through non metallic rigid PVC oval conduit/PVC casing capping including necessary accessories like bends, tees, elbow, etc fixed on wall/ceiling including second class hard wooden board /sunken type MS box of suitable size with plastic laminated white coloured sheet top cover 3 mm thick including 1.5 Sq mm PVC insulated copper conductor earth continuity wire complete all as specified and directed.
Supply and fixing wiring for circuit/submain wiring 2 X 2.5 sqmm alongwith 1.5 sqmm earth wire single core cable of FRLS, PVC insulated copper conductor multi stranded, in PVC conduit on surface/ recessed as required as directed.
All as item No.4 here-in-before but for wiring 2 X 4 sqmm alongwith 2.5 sqmm earth wire single core cable complete all as specified and directed.
All as item No.4 here-in-before but for wiring 2 X 6 sqmm alongwith 4 sqmm earth wire single core cable complete all as specified and directed.
S&F exhaust fans AC single phase 230\240 V of size 300 mm sweep with louver complete all as specified and directed.
S&F exhaust fans AC single phase 230\240 V of size 12" sweep, metal body complete all as specified and directed. Make: Usha, Crompton, Havells
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F SPN enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 amps as specified and directed.
Supply and fixing MCB SP 6-32 Amp (Make: Anchor/Legrand/ Havells) complete all as specified and directed.
S&F AC changeover Guard timer 230V AC, 50Hz, Operating temprature 0-100 degree C, LED display, Programme 1 hr to 12 hr, metalic enclouser suitable for window/split and pacakage type AC complete all as spd and directed. Make- Carrier or as approved by Engineer in Charge.
S&F Switch socket combination 3 pin 16 Amp flush type complete all as spd and directed.
S&F PVC rectangular block for mounting switch socket combination of 15 amps with plastic sheet cover, nut bolt complete all as spd and directed.
S&F PVC rectangular block for mounting switch socket combination of 15 amps with plastic sheet cover, nut bolt complete all as spd and directed.
S&F Automatic Street light control switch single phase using infrared sensor based Nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light Luxlevel. Required illumination level for switching ON is less than 30 Lux and for OFF greater than 10 Lux. The sensor along with suitable power contactor and Incomming outgoing MCB of 20-25 Amp rating, should be enclosed in a wall/pole mounted rust proof, electric shock proof. termite proof thermoplastic polycarbonate enclouser with Hinge Lid confirming to IP 66 protecetion class 2 withmain load circuit wiring(copper) of min 10 sqmm complete all as spd and directed. Make Swadeep-66-3Kw1P or equivalent as approved by Engineer in Charge.
M&L for Earthing complete with copper plate electrode 60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper strip 20X3 mm as earthing lead by means of bolts, nuts, check nuts and washers all as per electrical plate shown in plate no 3 connected to earthing test point all as specified or indicated including testing on completion. Note: Earth resistance should be less than 2 ohms.
Taking down chowkhat or frame with shutters (without taking off shutters from frame) n.exc. 1.5 sqm each complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 350x250x7mm or 450x300x7mm thick set in neat cement slurry and pointed in white or coloured cement to match on dado/skirting including 10mm thick rendering in CM1:4 and dismantling of tiles complete all as specified and directed.
S&F aluminium powder coated two track window including aluminum frame, glazed with 4 mm thick tinted glass including rubber bead joining cleat for fixing in position, concealed type lock for two shutter, PVC roller including 25x3mm aluminum flat all round window frame for fixing of wire gauge with stainless steel wire cloth 0.36 mm noimnal dia of wire and average width of aperture 1.40 mm on outer frame on side for fixing exhaust fan complete etc all as specifed below:- (a) frame (top & side) section shall of size 92.00x31.75x1.50mm (b) frame (bottom) section shall of size 92.00x31.75x1.50mm (c) Top & side members of shutters section shall be of size 18.00x40.00x1.50mm (d) Interlocking section of shutter shall be of size 18.00x40.00x1.50mm (e) Bottom members of shutters section shall be of size 18.00x40.00x1.50 mm. (Note :- Thickness or powder coating not less than 50 micron)
S&F powder coated anodised aluminium window and ventilator shutters, fixed/top hung/openable type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified of any colour (Note :- Thickness of powder coating not less than 50 micron).
S & F anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for partition, doors, windows, ventilators with one or more rebates including joining cleat and for fixing of exhaust fan etc. for fixing complete all as specified and directed.
Supply only 4.8 mm thick tinted or reflective type sheet glass glazing to aluminium ventilation windows and the like in square exc. 0.50 sqm in each pane complete all as specified and directed.
S7F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tank or galvanized wire staple complete all as specified and as directed.
S&F powdered coated Aluminium grill (DG 104) 10mm x 5.2mm thick fixed on aluminium section of suitable size fixed to aluminium window / ventilator with and including U or F type aluminium section all as specified.
M&L for Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement with water proofing compound all as specified.
M & L for preparation of newly plastered previously untreated surfaces of walls and applying two coats of distemper over a coat of average 1 mm thick wall care putty complete all as specified and directed.
M&L for demolition of brickwork or stone/ boulder masonry, laid cement mortar complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in in 1:6 CM complete all as specified and directed.
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in 1:6 cement mortar complete all as specified and directed.
M/S ROHIT CONSTRUCTION
M/S JALANDRA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .