Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
15 Mar 2021, 6:00 pmClosed
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF HELIPAD LIGHTS SECURITY LIGHTS ALONGWITH CONNECTED WORKS AT INS SHIKRA UNDER GE NW NOFRA AND REPAIR AND REPLACEMENT OF OLD DETERIORATED STREET LIGHT POLES AND LED STREET LIGHTS GARDEN LIGHTS ALONG WITH CONNECTED WORKS AT VARIOUS
2021_MES_422819_1
8845
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
MUMBAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NW NOFRA
₹97,000
Yes
25 Mar 2021
16 Feb 2021
20 Mar 2021
16 Feb 2021
15 Mar 2021
2 Mar 2021
16 Feb 2021 - 1 Mar 2021
Amount
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified and directed by Engineer-in-Charge.
Cutting and removing grass, vegetation bushes etc from surrounding water supply electric supply installation and removing all rubbish to a distance not exceeding 50 m as directed and cleaning/ brooming in water /electric supply station complete all as specified and directed by Engineer-in-Charge.
Trimming tree branches on the route of LT line nearer to LT/HT line , pump house , poer , street light fitting & poles complete all as specified and directed by Engineer-in-Charge.
Dismantling steel poles/struts, any size from existing detorated street pole complete all as specified and directed by Engineer-in-Charge.
Checking and repairs to street light fitting from Truss , Hanger, Halipad ,Highbay light, flood light , Perimeter light , Post Top Lanterns , Obstruction light, Avaition light fittings inside / out side of INS SHIKRA , NT POOL, SASSON COMPLEX , BOOT POOL, TALWAR CAMP, REIVERA & HARBOUR HEIGHTS, DUXBURY, ADITI AHILYA, VISHAKHA , VANDNA AND FOMA HOUSE , fitting any height street light pole (9/11) mtrs, hanger, truss, wall repair and checking and cleaning internal complete wiring, bulb, ignator, holder, rectifying the defects if any including repair/replacing the unserviceable items as mentioned in below items (wherever necessary) and testing the same on ground at site for its serviceability and refixing the same at original place/location complete all as specified and directed by Engineer-in-Charge. Note :- If the contractor have not given job card to his tradesman in any working day and have not attended any complaint , the necessory recovery of Rs. 500/- per day shall be imposed by Engineer-in-charge . Routine check shall be done for all types of non opps street / secutity light fitting in each and every location in routine wise manner every day by tradesman.
Taking down old unserviceable fitting. Supply and fixing in repair of imported energy efficient and super saver LED light fitting 105 Watt, 6.6 Amps suitable for helipad approach light complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable lamp. Supply and fixing of Energy efficent and super saver lamp holder alongwith canopy suitable for rotating beacon sysytem complete all as specified and directed by Engineer-in-Charge. Make as per Existng Sample or its equivalent as approved by GE.
Taking down old unserviceable transformer.Supply and fixing in repair of Isolating transformer,series to series 200 w, 5000 volts,current ration 6.6/6.6 amps suitable for Helipad identification light (CCR) Light fittings complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable fitting. S&F of luminaires integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 nos. LED are provided as per site requirement , complete all as specified and directed by Engineer-in-Charge. Make - Bajaj CAT PART NO - BGAV 302 LED or its equivalent in Havells / Phillips .
Taking down old unserviceable fitting. S & F in Repair aviation obstruction light yellow painted die cast auminium alloy housing , bulit in 75 VA step of transformer, hit resistant, clear thick glass and accessories complete with neon lamp 75 VA with provision of necessary GI pipe for fixing including taking down fron hanger/security post complete all as specified and directed by Engineer-in-Charge. Make : Bajaj Cat Part no 020075 of type BJAOL or its equivalent in phillips / Wipro / Crompton Greeves
Taking down old unserviceable fitting. S & F in Repair aviation obstruction light blue painted die cast auminium alloy housing , bulit in 75 VA step of transformer,hit resistant, clear thick glass and accessories complete with neon lamp 75 VA with provision of necessary GI pipe for fixing including taking down fron hanger/security post complete all as specified and directed by Engineer-in-Charge. Make : Bajaj Cat Part no 020075 of type BJAOL or its equivalent in phillips / Wipro / Crompton Greeves
Taking down old unserviceable wind cone assembly. Supply fix / errect in repair wind cone assembly (wind direction indicator) with bottom base plate and steady burning red obstruction light mounted on top,made of water repellent and resistant to rotating and mildew nylon fabric with colour combination red and white complete of size dia 600 mm, the dia of smallend is 300 mm and length is 2.4 mtr complete all as specified and directed by Engineer-in-Charge. Make shall be of AMA / Mtech system / ctech / cazonil / schenzhenor any other equivalent make as approved by GE.
Taking down/dismantling voltage stablizer of capacity up to 10 KVA,415 Volts carefully from its original position and repair & overhauling carrying with following complete all as specified and directed by Engineer-in-Charge.
(a) Draining out oil from Voltage Stablizer and dismantling the core connections from tank and taking out core along with winding from tank carefully.
(b) Cleaning the oil tank of voltage stablizer and removing sludges from tank.
(c) Dismantling the faulty winding from the core and re-winding to same with suitable size of insulated copper wire as per manufacturers specification.
(d) Core shall be assembled with suitable insulated hardware and insulating material varnishing and re-assamling all parts respect to original position etc.
(e) Refilling of new transformer oil and filter to achieve the BDV Values and testing complete all as directed.
(f) Inspecting/overhauling value of spring drive Mechanism by checking mechanism,lever assembly and apply multy grease lubricant to function smoothy.
S&F cable junction boxes IP 66/67 weather proof for out door installation with knock outs cable entry junction box size should be 205x255x112 with terminals including complete all accessories, all as specified and directed by Engineer-in-Charge. Make - Sintex , Finolex , Universal , National as approved by GE.
Taking down old unserviceable junction box . S&F of new cable junction boxes IP 66/67 weather proof for outdoor installation (with knock outs cable entry junction box size should be 300x100x450 mm aluminium bus bar 4 strip mounted on protection insulator with two Nos and front openable hinged and locking arrangements including complete all accessories , all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED garden light 25 W cylindrical shaped integral decorative LED bollard with Opal acrylic diffuser and IP 65 With all acessories including PCC foundation tapper plug bolts,nuts,screwed and GI pipe 76 mm dia etc complete all as specified and directed by Engineer-in-Charge. Make - Havells cat part No CORAL PT 25WLED 757 PSYMTOPC or its equivalent make in Philips / Jaquar as approved by GE.
Taking down old unserviceable light. S&F in repair of new 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting Source and LENs embedded toughned glass cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge. Make Jaquar cat part No. LSRT01S045XW or its equivalent Make in Phillips/Havells as approved by GE.
Taking down old unserviceable fitting. S&F of new 48 watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing wwith high power LED as lighting Source and LENs embedded PC Cover with IP66 Protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat part no – ENDURA CITY LINER NEX GEN SL 48WLED757SAYSBOPC or its equivalent make in Philips / Jaquar as approved by GE.
Taking down old unserviceable fitting. S&F of New LED Bldg security light 90 Watt indus series powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection , complete all as specified and directed by Engineer-in-Charge. Make- C&S CAT PART NO - LTESS40x2.5HPLED/LS Indus or its equivalent make in Philips / Jaquar / Havells as approved by GE.
Taking down old unserviceable fitting. S&F of 120 WATT LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-Charge. Make- Havells CAT PART NO - ENDURA CITY LINER NEO SL 120W LED 757 SASYBOTG or its equivalent make in Philips / Jaquar as approved by GE.
Taking down old unserviceable fitting. Supply & fix 120 watt JETA PRO PLUS Energy saving environmental friendly, long life,exclusive innotive die cast aluminium IP65 flood light with high power LED s as light source,suitable for high lighting architectural façade highmast and general purpose. Make- Havells Cat part no - JETA PRO PLUS FL120WLED757LTG or its equivalent make in Philips / Jaquar as approved by GE.
Supply & fix in reppcement of Industrial highbay integral LED fittings of capacity 120 watt complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearance complete all as specified and directed by Engineer-in-Charge. Make- Jaquar lighting Cat No - LHBL 090120XW or its equivalent make in Philips / Havells as approved by GE.
S&F in Replacement LED driver for street light / highbay light fitting / flood light 120/150 Watt of any type and size etc to match with existing complete all as specified and directed by Engineer-in-Charge. Make:- C&S/Bajaj/Havells as approved by GE.
Repai/replacement of old unserviceable pply and fixing LED post top integral pole mounted decorative LED post top upto 30 Watt with IP65 protection suitable for 40mm dia GI tubing including complete all as specified and directed by Engineer-in-Charge. Make- Philips Cart part No BGP 161 LED2500/NW PSU 220-240V 7043 or its equivalent make in Havells/ Jaquar as approved by GE.
Taking down old unserviceable fitting. S&F of new 240 Watt LED flood light with pressure die cast aluminium housing with lens (IP 65 rating)) ,complete with all accessories i.e. nuts, bolts, washers etc items included and errection charge of pipe in hard stand (Note : light fixing on 40 mm dia 2 Nos pipe 1 mtr hight at halipad) complete all as specified and directed by Engineer-in-Charge. Make- Jaquar CAT PART NO - JBI-WHT-LFLD 02S240XC or its equivalent to Havells / Phillips as approved by GE.
Taking down old unserviceable light. S&F of new 70 Watt LED flood light with pressure die cast aluminium housing with lens (IP 65 rating)) ,complete with all accessories i.e. nuts, bolts, washers etc and all as specified and directed by Engineer-in-Charge. Make- Jaquar CAT PART NO - JBI-WHT-LFLD 02S070XW or its equivalent to Havells / Phillips as approved by GE.
Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole complete all as specified and directed by Engineer-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately) Make of poles:- National Tubing Co./ Bombay Tubing Ltd / India Tube and Co. / Bharat Conduit & Steel Works as approved by GE.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat No 507791 or its equivalent in Siemens / GE as approved by GE. (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
Taking down/dismantling UPS of capacity upto 10 KVA, 415 Volts carefully from its original position and repair & overhauling carrying with following complete all as specified and directed by Engineer-in-Charge.
(a) Replacement of capacitor 4700MFD/450 Volt,10MFD/440VAC.
(b) Replacement of connector 2 way/60A,3 Way/60 Amps,4 way/60 Amps.
(c) Replacement of display digital meter.
(d) Replacement of fuse igbt 75A/600 volt
(e) Replacement of relay 30A/12/1
(f) Replacement of shunt 75 mv/50Amps.
(g) Replacement of module & Sensing X"MER Charger 19-0-19(440 volt),inverter 7-0-7(230 volt),Display 13-0-13(230 volt)
(h) Replacement of Current Transformer CT25A Double CON
(j) Replacement of tranformer,inverter tx 130v/260v,DC Choke 1.5MH/35A
(k) Replacement of PCB,Charger 3 phase,dc card,combo card front display meter card,divider card.
(l) Replacement of Display sticker,isolate terminal,fuse holder,Registor 1k/20 w,spot switch,buzzer,3 way box connect etc
Dismantling & Repair Static Frequency Converter of capacity 60 KVA, carefully from its original position and repair & overhauling , fabrication,carrying with new essential parts complete all as specified and directed by Engineer-in-Charge.
Dismantling & Repair Static Frequency Converter of capacity 05/03 KVA, carefully from its original position and repair & overhauling , fabrication,carrying with new essential parts complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 9 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket, tapper plug,bolts nuts and screws etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of test Link for connecting the earth pit and down conductor complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable clamp and Supply and fixing iron clamp (flate 25 x 4 MM) with nuts, bolts, washers and removing old clamps complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable bracket and Supply and fixing of new bracket for street/security light fitting made of GI pipe 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable bracket and Supply supply and fixing of new bracket for street/security light fitting made of GI pipe 50 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required complete all as specified and directed by Engineer-in-Charge.
Supply and fix GI tubes Light grade of 40 mm dia complete with all fittings (like; union, tee, bend, elbow, reducer, socket) to be fixed on wall and ceilings or laid in floors/trenches complete all as specified and directed by Engineer-in-Charge.
M&L for straight through jointing heat shrinkable kit for cable of 240 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
M&L for straight through jointing heat shrinkable kit for cable of 185 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables complete all as specified and directed by Engineer-in-Charge.
Taking up old U/S XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including Old concrete cable cover from trenches/walls/ceiling/poles etc any size complete all as specified and directed by Engineer-in-Charge.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 1.5 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6s q mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed by Engineer-in-Charge. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. laid in duct / along pole/wall tc including making connection complete all as directed. Note : The cost of Al thimbles/lugs and cable gland etc to be included in quoted rate and no extra payment will be made for it.
Taking down old unserviceable MCCB . S & F MCCB, 415 volts, pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections conforming to IEC 60947-2 , complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no 420003 or its equivalent in siemens / GE
Taking down old unserviceable MCCB . S & F MCCB, 415 volts, pole of cap 100 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat part no 420005 or its equivalent in siemens / GE
Taking down old unserviceable MCCB. Supply and fiixing MCCB, 415 volts, pole of cap 160 Amps, 36 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no 420087 or its equivalent in siemens/GE
Taking down old unserviceable MCCB . Supply and fixing MCCB, 415 volts, pole of cap 250 Amps, 36 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no 420239 or its equivalent in siemens / GE
Taking down old unserviceable MCCB .Supply and fixing MCCB, 415 volts, 3 pole of cap 400 Amps, 50 KA, ICS = 100% ICU with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no 422016 or its equivalent in siemens / GE
S & F in replacement of MCB, SPN 40 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE.
Supply and fixing of MCB SP 6-32 Amps, 240 Volts - 10 Nos , complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE.
Supply & fix MCB , DP 63 Amps capacity, C Curve type suitable for 240 volts AC supply, DP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed by Engineer-in-Charge. Make-Legrand / Siemens / GE.
S & F of MCCB sheet metal enclosure suitable for holding MCCB of 100 amp capacity four pole type including fixing accessories etc complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no -607906 or its equivalent in Siemens / GE.
S & F of MCCB sheet metal enclosure suitable for holding MCCB of 160 amp capacity four pole type including fixing accessories etc complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat part no -607944 or its equivalent in Siemens / GE.
S & F in replacement 63 Amps Triple pole and earth enclosure with a three pin and earth plug with socket complete with one single pole MCB complete all as specified and directed by Engineer-in-Charge. Make -Legrand Cat part no -507864 or its equivalent in Siemens / GE.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed by Engineer-in-Charge. Make - Legrand cat No 507791 or its equivalent in Siemens / GE. (Note : The cost of removing old box and making all surface good i.e. brick work, plastering etc is to be included in quated rate)
M&L for PCC 1:3:6 type C2 (using 20mm graded stone aggreagate) for base of pole including use and wste of form work complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4 for coping of pole complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through ISI marked with accessories fixed on pole/wall/ceiling/truss etc complete all as specified and directed by Engineer-in-Charge. Make of cable : Polycab, Finolex, Havells.
S&F HDPE of pressure rating 6kg/cm sq pipe of 40 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for scraping the old paint from steel tublar poles by wire brush not more than up to 9/11 mtr length above ground level including street light arms applying one coat of steel primer and two coat of aluminium paint and marking pole no. , complete all as specified and directed by Engineer-in-Charge.
M&L for scraping the old Painted surfaces and spray painting of LT panel board any size with two coat of synthetic enamel paint of approved colour complete with all fitting etc complete all as specified and directed by Engineer-in-Charge.
ORIENT ELECTRIC CO
NOEL ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .