| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance VILL AMDIHA SATANPUR PINDRAJORA BOKARO JHARKHAND 827013 | BOKARO | JHARKHAND | 827013 | Admitted-Finance |
Tender Value
₹54.5 L
EMD Value
₹1.1 L
Closing Date
15 Apr 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
3rd Floor JIIDCO New RIADA building Namkum Industrial area Ranchi
Construction of Wood Craft Cluster building at Bokaro Jharkhand
2021_JIIDC_49138_1
JIIDCO/01/Bokaro/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Bokaro
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
JIIDCO
₹1.1 L
19 May 2021
6 Apr 2021
16 Apr 2021
6 Apr 2021
15 Apr 2021
6 Apr 2021
120 days
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E.I. (wide classification of soil item-B)
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or plinth including ramming & watering in layers not exceeding 150 mm thick with all leads and lifts including cost of materials, Labour, royality & taxes all complete as per building specification and direction of E/I. ( mode of measurement compacted volume)
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I.
Providing P.C.C. M-200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone metal grade - III (50 mm to 25mm size) clean coarse sand of F.M 2.5 to 3 including screening, shuttering,mixing cement concrete in mixer and placing in position vibrating, skirting, curing, taxes and royalty all complete all complete as per building specification and direction of Engineer-incharge.
Providing R.C.C. M-200 with normal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I
Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75 Abrick work in C.M (1:6)in superststructure with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials,scaffolfing, raking out joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l
Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening, carrige of materials, scaffolding raking out joints to 15 mm depth , curing, taxes and royalty (but excluding the cost of reinforcement ) all complete as per building specification and direction of E.I
Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in roof beam, floor beam with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering mixing cement concrete in mixes and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement, taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in Band at Lintel Level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering mixing cement concrete in mixes and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement, taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1½:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing av. 63mm thick R.C.C. M-200 with nominal mix of (1:1.5:3) Chajja with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering and mixing cement concrete in mixer and placing in position, vibrating, striking 6mm cement plaster (1:4) in ceiling and sides of chajja with sand of F.M. 1.5 curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing Toe steel reinforcement of 8mm dia to 10mm 12, 16, 32 MM dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel)
Providing and fixing fan hook of 16mm dia. M.S. bar 1 metre long bent ot required size and shape placed in position and fixed in RCC slab/beam at the time of casting all complete at the time of casting all complete as per building specification
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete
Supplying and fixing rolling shutters of approved make , made of required size M.S laths , interlocked together through their made entire length and jointed together at the end by locks , mounted on 80x1.20 mm M.S lathes with 1.20mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing primer one coat of approved shade and make over new wooden surface dirt, scales smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including preparing the surfave after cleaning, removing dirt cales, smokes grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Supplying, fitting & fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminum fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel prime
Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticals sides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin- charge.
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing two coats snow cem coats over new surface with approved quality of lime including cost of cleaning surface by rubbing smooth with sand paper scaffolding curing,taxes all complete as per building specification and direction of E.I
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete 600 x 600mm size
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes 110 mm Rain water pipe
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler - 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend - 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe - 110
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110 mm
Carriage of materials Sand lead 25 KM
Stone Chips lead 15 KM
Bricks lead 8 KM
Cement lead 10 KM
Steel lead 10 KM
Plumbing & Sanitary: Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I. 25mm dia weight not less than 500 gram
Plumbing & Sanitary: Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I. 40 mm dia weight not less than 1.0kg.
Cutting chajja or cornice for laying G.I. pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortar (1:4) and cement plaster (1:4) as per specification and direction of Engineer-in-charge.
Cutting hole upto 30x30 cm in walls including making good the same with ommon burnt clay F.P.S (non modular) bricks
Providing and fixing water closet squatting pan (Indian type W.c. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cictern, including flush pipe, with manually controlled device (handle lever) conforming to ISI: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing white vitrous chaina pedsestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cictern, including flush pipe, with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the wall and floor wherever required. W.C. pan with ISI marked white solied plastic seat and lid.
Providing andd fixing white vitrous Chaina flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing pipe, sereades with urinal and clamps (all in C.P brass) with waste fitting in C.P brass, including painting of fittings and cutting and making good the walls and floor wherever required. Single half urinal with 5 litre PVC automatic flushing cictern
Providing and fixing wash basin with C.I. brackets 15mm C.P brass pillar tap, 32mm C.P brass waste of standard pattern, including painting of fitting and brackets, cutting and making good the walls sherever required. White vitreous Chaina wash basin size 630x450mm with a single 15mm C.P. brass pillar tap.
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. (for classification of soil items A)
Constructing brick masonary chamber for undergroun C.I. inspection chamber and bebds with bricks in cement mortar 1:4 (1 cement :4 coarse sand) C.I. cover with frame (light duty) 455x610mm internal dimensions, total weight of cover eith frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg) RCC top slab with 1:1.5:3 mix (1 cement 1:5 fine sand 3 graded stone aggregate 20 mmnominal size) foundation concrete 1:5:10 (1 cement 5 fine sand 10 graded stone aggregate 40 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement 3 coarse sand) finished with floating coat of neat cement on wall and bed concrete etc. complete as per standard design. Insidedimension 500x700mm and 45 cm deep for pipe line with one or two inlets. With common burnt caly F.P.S (non modular) bricks of class designation 7.5
Supplying laying fitting and fixing NP2 R.C.C spun pipes with collars jointed with stiff mixture of ement mortar in the proportion of 1:2 (1 cement:2 fine sand) including testing of joints etc 250mm dia
Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes. 75 mm
Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes. 110 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall40 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal outer dia Pipes
Providing and fixing PTMT grating of approved quality and colour. Circular type - 100 mm nominal dia
Providing and fixing PTMT grating of approved quality and colour. Circular type125 mm nominal dia with 25 mm waste hole
Providiang and placing on tarrace (at all floor lever) polyethylene water storage tank IS: 12701 marked, with cover and suitable locking arrangment and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank,
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 75 mm Coupler
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110 mm Coupler
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 75 mm Single pushfit Coupler
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110 mm Single pushfit Coupler
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 75 mm Single tee with door
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110 mm Single tee with door
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 75 mm Single tee without door
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110 mm Single tee without door
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 75 mm bend
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110 mm bend
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 75 mm Shoe
Providing and fixing PVC Pipe fittings with all accessories (supreme make) 110 mm Shoe
Electrical work: Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Twin Control Point Wiring in PVC Conduit, with Modular type Switch:-Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc as required.
Wiring for curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC conduit as required
Wiring for curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC conduit as required 2x2.5 sq.mm +1x2.5sq.mm earth wire
Wiring for curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC conduit as required 2x4.0 sq.mm +1x4.0 sq.mm earth wire
S/F PVC conduit- Supplying and fixing of following sized PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20mm
S/F PVC/G.I. boxes- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 75mmx75mmx50mm deep/(4"x4")
Telephone wiring in existing conduit- Supplying and drawing following pair, 0.5 sq.mm FR PVC copper conductor, unamoured telephone cable in the existing surface/recessed PVC conduit as required. 2 pair
TV cable in existing conduit- Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit a required.
S/F modular type switch/socket on the existing switch box including connection etc. as required 5/6 amp. Switch & 3 pin 5/6 amp. Socket/outlet
S/F modular type switch/socket on the existing switch box including connection etc. as required 3 pin 5/6 amp. Socket/outlet
S/F modular type switch/socket on the existing switch box including connection etc. as required Telephone socket outlet
S/F modular type switch/socket on the existing switch box including connection etc. as required TV antenna socket outlet
S/F modular type electronic fan regulator- Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as rquired.
S/F suitable size G.I. box with modular plate and cover in front on surface or in recess including P.F. 3 pin 5/6 amp.
S/F suitable size G.I. box with modular plate and cover in front on surface/recess including PF 6 pin 15/16 amp. And 5/6 amp. Modular socket outlet and 15/16 amp. Modular switch connection as painting etx as required
S/F 3 pin 5 amp ceiling rose on the existing junction box wooden block including connection etc. as required.
S/F brass vatton/Angle Holder including connection etc as required
S/F Dingdong call bel- Supplying and fixing dingdong call bell suitable for D.C/A.C single phase, 2230 volts, complete as required.
ITC fluorescent fitting directly on furface- Installtion, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc, directly on ceiling/wall, including connection with 1.5sq.mm. FR PVC insulated, copper conduit.
ITC of ceiling fan including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm FRPVC with 1.5 sq.mm FRPVC insulated copper conductor single core cable etc. as required.
ITC of exhaust fan up to 450mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc as required.
S/F TP MCB DB- Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc, as required (But without MCB/RCCB/Isolator) 4 way (4+12) double door, Horizontal type
S/F TP MCB DB- Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc, as required (But without MCB/RCCB/Isolator) 6 way (4+18) Double door, Horizontal type
S/F 5 amp. To 32 amp rating 240 volt "C" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB conplete with connection testing and comissioning etc as required. 6/32 amps, single pole, "B"
S/F 'C' series, MCB- Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection testing and commossioning etc as required. 40 amps, TPN
S/F 'C' series, MCB- Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection testing and commossioning etc as required. 50/63 amps, TPN
S/F following rating single pole 240 volts isolator in the existing MCB DB complete with connection testing and commissioning etc as required. 40 amp
S/F following rating single pole 240 volts isolator in the existing MCB DB complete with connection testing and commissioning etc as required. 63 amp
Earthing with G.I. earth pipe 4.5mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required.
Copper earth plate elecrtode- Earthing with copper earth plate 600mm x 3mm thick including accessories and providiang masonary enclosure with cover plate having locking arrangement and watering pipe etc as required (But without charcoal or coke and salt)
Salt/Charcoal for plate earth electrode- Extra for using salt and charcoal for G.I. or copper plate earth electrode as required.
S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc as required
P/F lighting conductor final made of 25mm dia 300mm long copper tube having single pole at top with 85mm dia 3mm thick cipper base plate including holes etc complete as required.
Reverting sweating and soldering of copper/G.I. tape (with another copper G.I. tape base of the final or any other metalic object) as required.
P/F copper lightning conductor tape in horizontal run- Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (for horizontal run)
P/F copper lighning conductor tap in vertical run- Providing and fixing copper tape 20mm x3mm thick on parapet or surface of wall for lightning conductor complete as required (for vertical run)
P/F testing joint made of 20 x 3mm thick cipper strip 125mm long with 4 nos. of tinned brass bolts nuts check nuts and spring washer etc complete as required.
MV cable laying upto 120 sqmm in ground- Laying of one number PVC insulated and PVC sheathed/ x LPE power cable of 1.1 KV grade of following size direct in ground including excavationn sand cushioning, protective covering and refilling the trench etc as required.
MV cable laying upto 400 sq mm in ground- Laying of one number PVC insulated and PVC sheathed / x LPE power cable of 1.1 KV grade of following size direct in ground including excavation sand cushoning protectve covering and refilling the trench etc as required.
Supply 1200mm ceiling an Bajaj/cromption or any other approved make etc without regulator
S/F 18 watt LED
1 x 28 watt T5 tube light fitting
Supply 12" dia khaitan India exhaust fan etc all required
SEPTIC TANK WITH SOAKPIT-2018Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing P.C.C. M-100 in nominal mix of (1:3:6) in foundation with approved quality of stone chips 20mm to 6mm size graded and mixing cement sand of F.M 2.5 to 3 including screening, shuttering, vibrating, skirting, curing, taxes and royalty all complete all complete as per specification and direction of Engineer-incharge.
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Providing TMT steel reinforcement above 16mm to 36mm dia bars as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Carriage of Material Bricks Lead = 8 km
Sand lead = 25 km
Stone chips lead = 15 km
Local Sand lead = 25km
Deep Boring: Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. From 0.00 M to 50.00 M below G.L.
Deep Boring: Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. From 51.0 M to125.00 M
Deep Boring: Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. From126.0 M to250.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I.
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
1% Labour Cess
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .