| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC | ₹1.5 Cr | 1 | Accepted-AOC Due to lower side of rates |
| 2 | 2₹1.5 Cr+₹8.0 L (5.43%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹1.5 Cr+₹8.0 L (5.43%) | 2 | Rejected-AOC Due to higher side of rates |
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
25 Feb 2022, 2:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PUBLIC HEALTH ENGINEERING DIVISION NARWANA
12 id RCC NP2 IC Const of 1 no SS tank 2 No SS well 1 no HLT 3 no FB 1 no CWT 1 no PC Bwall iron gate Prov Fixing PM E Panel CI DFPE Specials 119 no FHTC 196 no FC Dismantling of streets Const of SV houdies in various streets etc
2022_HRY_208568_1
EIC No. 14.67 dt. 15.02.2022
Open Limited
Civil Works
Tender
9 days
NARWANA
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹3.1 L
Yes
8 Oct 2022
17 Feb 2022
25 Feb 2022
17 Feb 2022
25 Feb 2022
17 Feb 2022
Amount
Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum four (4) star rating durites directly coupled to AC squirrel cage induction type motor with 1440 RPM, 3 phase, 50Hz and accessories as described in Schedule No. II complete in all respects with priming arrangement with complete base frame. A) Raw Water pump set 600 LPM 12 mtr. Head
Supply, erection, testing and commissioning of wall mounted electrical panel board fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 500 x 1200 mm and 400 mm deep having following accessories complete in all respects as per approved NIT 1. Incomer switch 200 Amp. 2. Aluminum bus bar chamber of 300 Amp Capacity. 3. Volt meter 100 x 100 mm range 0 to 500 V (AE/KAPPA/L&T) 4. Indicating lamp one set.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items. A) For Raw water Pump set for 600 LPM x 12 Mtr. head = 2 Nos. (a) Main switch 63 Amp. 2 no. (L&T Siemens, ABB) (b) Volt meter 100 x 100mm range 0 to 500 volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100 x 100mm range 0 to 100 volt 2 no. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/L&T) (e) VSS&ASS 1no. & 2 Nos of approved make (f) SPP 2 no. of approved make (g) Motor starter, star delta 2no. for 600 LPM x 12 M Head Motor (L&T Siemens, AAB) (h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp = one set. (j) Change over switch 63 Amp = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items. B) For Clear water Pump set for 600 LPM x 40 Mtr. head = 2 Nos. (a) Main switch 63 Amp. 2 no. (L&T Siemens, ABB) (b) Volt meter 100 x 100mm range 0 to 500 volt 1 no. (AE/KAPPA/L&T) (c) Amp. meter 100 x 100mm range 0 to 100 volt 2 no. (AE/KAPPA/L&T) (d) CT 100/3 Nos. (AE/KAPPA/L&T) (e) VSS&ASS 1no. & 2 Nos of approved make (f) SPP 2 no. of approved make (g) Motor starter, star delta 2no. for 600 LPM x 40 M Head Motor (L&T Siemens, AAB) (h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp = one set. (j) Change over switch 63 Amp = 1 No.
Supply, erection, testing of ISI marked copper wire for 4 No. Motors with under ground system in PVC & flexible pipes copper wire complete in all respects with accessories like thimble etc. Complete in respects. i) 6 sq mm 3 core
ii) 10 sq mm 3 core
Supply, erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduct pipe & copper wire etc. as per approved specifications complete in respects.
Supply, erection, testing of reputed make LED light 100 watts with fitting and accessories complete in respects.
Operation and Maintenance for the complete scope of work (disinfection material supplied by the PHED) as per schedule-IV for a period of 5 year after 12 months during defect liability period & 3 months trial run period (will be charged to the A/Mtc. Estimate) complete in all respect Operation and maintenance during the defect liability period ( Operation only) after 3 months trial run period
(ii) For 1st year operation and maintenance after defect liability period.
(iii) For 2nd year operation and maintenance.
(iv) For 3rd year operation and maintenance.
(v) For 4th year operation and maintenance .
(vi) For 5th year operation and maintenance .
Bidder Name
Amount
Shiv Shakti(GSTN-NA)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
Shiv Shakti
ROHTASH KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .