| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹36.5 L+₹48,880 (1.36%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹36.8 L+₹70,280 (1.95%)Rejected-Finance | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹37.1 L+₹1.1 L (2.95%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹38.7 L+₹2.6 L (7.33%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L5 | Rejected-Finance HIGHER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar pin 143001
REPAIR REPLACEMENT OF LT OH LINE UG CABLES AND CONNECTED ITEMS OF EXTERNAL ELECTRIC SUPPLY IN THE AREA OF AGE BR-I AT OLD AMRITSAR CANTT
2023_MES_602652_1
GE/ASR-25/2023-24
Open Tender
Civil Works
Works
180 days
GE Amritsar
Class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹80,000
28 Oct 2024
12 Jun 2023
11 Jul 2023
12 Jun 2023
10 Jul 2023
26 Jun 2023
Amount
Material and Labour for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc ; Complete all as specified and directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take outmost care to avoid damage to existing lines/structures. If any breakdown of line is caused during prunning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occurs the contractor will be solely responsible for it.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr ; Complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on hard / dense soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr; Complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil ; Complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point ; Complete all as specified and directed by Engineer-in-Charge.
Supply & laying HDPE pipe 75mm bore for laying of LT cables etc complete with all accessores ; Complete all as specified and directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-10 sqmm 4 Core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-16 sqmm 4 Core ; Complete all as specified and directed by Engineer-in-Charge.Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-25 sqmm 4 Core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-35 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-50 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-70 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-95 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-120 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-150 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-300 Sqmm 31/2 core ; Complete all as specified and directed by Engineer-in-Charge. Note :- i)The cable will be terminated at connections with end joints heat / cold shrink ii) The rate quoted shall be inclusive of the same.
Material and Labour for making good the damaged Tar Road by using additional stone metal, PCC etc ; Complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repair of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approved ; Complete all as specified and directed by Engineer-in-Charge. Note:(i) MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. (ii) Labour for MCCB, MCB, Switch fuse unit and change over switch measured and paid separately. (iii)Rate of new Busbar, panel door, cable gland, lugs,CRC Solution,nut,bolt, painting etc and washers are deemed to be included in quoted rates.
Material and Labour for replacement of existing Amp meter (0-300Amp) along with unserviceable CT if any from existing LT Panel of any size ; Complete all as specified and directed by Engineer-in-Charge.
Material and Labour for replacement of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size,; Complete all as specified and directed by Engineer-in-Charge.
Material and labour for paintingof LT Steel tubular pole,9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle ; Complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion ; Complete all as specified and directed by Engineer-in-Charge. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates. iii) The earthing done in presence of JE /E-in-Charge will only be measured. iv) The material required for earthing will be first approved from E-in-charge before bulk procurement
Supply, installation, testing and commissioning of switch Air break, Gang operated with 12 insulator polymer type type switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 400 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV system including necessary electric connection and 11 KV fuse (drop out type) of capacity as per site requirement and as specified by Engr Incharge , complete with DO fuses assembly with channel and one No. operating Rod of 25 mm dia bore medium grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set all as directed by Engineer-in-charge.
Supply ,Installing, commissioning and testing in replacement LT bus bar, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 2 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm -90cm long and 45 cm grouted in PCC complete inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated alluminium busbar 300amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and directed by Engineer-in-Charge. (a)MCCB 200 Amp four pole with Breaking Cap 25 KA-01 No (Incoming) (b) Volt Meter (digital Type (0 T0 600 Volts)-01 No (c ) Ammeter (digital type) with Cts 0-300Amps)-01 No (d) Phase indication lamps LED type with holder-01 Set(Set of Three)
Supply ,Installing, commissioning and testing in replacement LT bus bar, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 2 mm thick CRCA sheet and inner sheet of 2.0 mm thick and angle iron frame of size 50x50x5mm-90cm long and 45 cm grouted in PCC complete inside depth not less than 90 cm ( 45 cm grouted in PCC) and size suitable to accommodate the following accessories, with insulated alluminium busbar 200amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and directed by Engineer-in-Charge. (a)MCCB 100 Amp four pole with Breaking Cap 25 KA-01 No (Incoming) (b) Volt Meter (digital Type (0 T0 600 Volts)-01 No (c) Ammeter (digital type) with Cts 0-300Amps)-01 No (d) Phase indication lamps LED type with holder-01 Set(Set of Three)
Supply ,Installing, commissioning and testing in replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside length not less than 90 cm (45 cm grouted in PCC) and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and directed by Engineer-in-Charge. (a)MCCB 250 Amp four pole with Breaking Cap 25 KA-01 No (Incoming) (b) MCCB TPN 100 Amps 4P with breaking cap 25KA - 02Nos (For Out Going) (c) MCCB 630Amps 4 pole with breaking capacity 25 KA -04 Nos (For Out Going) (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e) Ammeter (digital type) with CTs 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three) Notes:- 1. The Panel Should be approved by CPRI. 2) The rates Rate Quoted shall include for earth work and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0..45 M from GL to the bottom of panel board.
Supply and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size ; Complete all as specified and directed by Engineer-in-charge. (Note :- (a) Jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumper & tree branch cutting to make a safe distance from over head line.)
Supply and Fixing in repairs of GI continuous earth wire 4mm dia on cross of poles for guarding including binding with aluminum wire 16 SWG etc. and dismantling of old broken guarding ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for restringing of LT over head line consisting of 4/5 conductors by dismantling taking down, repairing wherever required including cutting, re-joining and restringing in situ, with proper sag, binding to insulator with and including aluminium binding wire ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm ; Complete all as specified and directed by Engineer-in-charge. Note : Loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
Supply only new insulating oil conforming to IS 335 for suitable for transformer 11/0.433 KV etc ; Complete all as specified and directed by Engineer-in-charge.
Labour only for dehydration filtration and cleaning of transformer oil of 66 KV / 11KV power transformer / distribution transformer / HT switchgear till achievement of die-electric-strength of 60 KV for new insulating oil and 45 KV for existing oil at 2.5MM Gap ; Complete all as specified and directed by Engineer-in-charge. Note : Toping of Transformer oil shall be measured and paid separately.
Supply & fixing LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutral or as per site requirement ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement of silica gel including cleaning the breather ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement, breather assembley with silica gel ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement of HT bushing, porcelain vitreous brown body suitable for 11 KV as per IS 3347. as per sample ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement of LT bushing, porcelain vitreous brown body 1100 V grade as per IS 3347 ; Complete all as specified and directed by Engineer-in-charge.
Supply only HV rod, brass, 12 mm dia, 300 mm long with brass nut, 2 Nos and washers ; Complete all as specified and directed by Engineer-in-charge.
Supply only LV rod, brass, 15 mm dia, 300 mm long with brass nut 2 Nos and washers ; Complete all as specified and directed by Engineer-in-charge.
Decanting the transformer oil from leaking transformer by opening the stop valve.Checking for leakages, arresting the leakages, replacing cork sheet gasket 5 mm thick,bushing,washer, HV/LV Road,tapchanger gasket, reassembling the transformer completely refilling transformer oil, connecting HT / LT connection ; Complete all as specified and directed by Engineer-in-charge. NOTE:(i) Spares required shall be measured and paid separately under relevant. (ii) Topping of transformer oil will be measured and paid separately. (iii) Gasket, cork sheet,washers are deemed to the quoted rates.
Supply and fixing in existing panel board against replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA ,,adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in existing panel board against replacement MCCB, 4 Pole, 200 Amps , with breaking capacity 25 KA , ,adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in existing panel board against replacement MCCB, 4 Pole, 100 Amps , with breaking capacity 25 KA ,,adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in existing panel board against replacement MCCB, 4 Pole, 63 Amps , with breaking capacity 25 KA , ,adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for taking down carefully Transformer of capacity 100/200KVA, any make, any type from pole / plinth/ base, disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm, shifting / transporting transformer carefully from the sub station to the other substation/power house 5 Kms of area , transporting returning back to the other substation installing re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc ; Complete all as specified and directed by Engineer-in-charge. (Note : (i) Insulating oil will be measured and paid separately. (ii) Painting of transformer is including of quoted rates
Material and Labour for taking down carefully Transformer of capacity 250 / 500 KVA, any make, any type from pole / plinth/ base, disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm, shifting / transporting transformer carefully from the sub station to the other substation/power house 5 Kms of area , transporting returning back to the other substation installing re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc ; Complete all as specified and directed by Engineer-in-charge. (Note : (i) Insulating oil will be measured and paid separately. (ii) Painting of transformer is including of quoted rates
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of length 2 m complete; Complete all as specified and directed by Engineer-in-charge. Note (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
Supply and fixing in replacement danger notoce plate all as per SSR part-I/II for 440 Volts incl MS strip and nut bolts ; Complete all as specified and directed by Engineer-in-charge.
kailu construction co
Saini Constructions
Raman Electric Trading Co
HARPAL ENGINEERS AND BUILDERS
diamond electrical
Bharat Builder
R D Bansal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .