Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | S A S NAGAR | PUNJAB | 160059 | ₹35.1 L | L1 | Accepted-AOC L1 QUOTED |
| 2 | L2₹35.9 LRejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | ₹35.9 L | L2 | Rejected-AOC L2 QUOTED |
| 3 | L3₹38.1 LRejected-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | ₹38.1 L | L3 | Rejected-AOC L3 QUOTED |
| Sl No | Description | Qty | Unit | HARISH SALES CORPORATION L2 | Anil Kumar Gupta L3 | Baba Engineers and Contractors L1 |
|---|---|---|---|---|---|---|
| .01Note :The unit rate quoted by the tenderer under Col No (13) of Sch `A’ (BOQ) unless specifically mentioned otherwise such as labour only/fixing only, for all items of works shall be deemed to be including cost of all materials, labour, tools and plants, testing and commissioning of work in position complete as required for entire completion of work. | ||||||
| 1.00 | Excavating in trenches in soft /loose soil , not exceeding 1.5 m wide and not exceeding 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engrineer-in-Charge. | 98.6 | CUBIC METRE | 120 ₹11,832 | 250 ₹24,650 | 180 ₹17,748 |
| 2.00 | Returning filling soft/ loose soil in trenches including spreading, leveling in layers not exceeding 25cm thick, watering and well ramming, complete all as specified and directed by Engineer-in-Charge. | 72.5 | CUBIC METRE | 40 ₹2,900 | 100 ₹7,250 | 80 ₹5,800 |
| 3.00 | Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge. | 26.1 | CUBIC METRE | 50 ₹1,305 | 100 ₹2,610 | 60 ₹1,566 |
| 4.00 | Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates and finished the surface rough to provide adequate bond for the topping as in sub base ,foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. | 0.25 | CUBIC METRE | 6,000 ₹1,500 | 2,800 ₹700 | 3,500 ₹875 |
| 5.00 | Plain cement concrete ,100 mm thick (1:2:4) type B-2, using 40 mm graded mechanically crushed stone aggregatesd topping as in sub base finished even & rough to receive the bedding mortar in and including demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge. | 251.52 | SQUARE METRE | 300 ₹75,456 | 500 ₹1.3 L | 250 ₹62,880 |
| 6.00 | Plain Cement concrete 100 mm thick type B-2, 1:2:4 by using 40mm graded mechanically crushed stone aggregate as in floor/hardstanding etc ,laid in panels of approved size and finishing the surfaces of concrete even and rough without using extra cement , complete all as specified and directed by Engineer-in-Charge.
Note :- Quoted rates are inclusive of use and waste of formwork and to devide the area in panels. | 14.58 | SQUARE METRE | 800 ₹11,664 | 500 ₹7,290 | 400 ₹5,832 |
| 7.00 | Brick work with sub-class `B' bricks Fly ash bricks (bricks shall be burnt clay fly ash building bricks as per IS- 13757), straight or curved on plan exceeding 6 M mean radius built in cement sand mortar 1:4 complete , complete all as specified and directed by Engineer-in-Charge.
Note : Quoted rates are inclusive of providing proper anchorage and bond between new brick wall & already existing columns as per site condition. | 39.72 | CUBIC METRE | 5,000 ₹2.0 L | 6,000 ₹2.4 L | 5,500 ₹2.2 L |
| 8.00 | Brick work with sub-class `B' bricks old size , straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 in and including demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc for the area where unservicable bricks retrived and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge. | 2 | CUBIC METRE | 7,000 ₹14,000 | 4,600 ₹9,200 | 5,500 ₹11,000 |
| 9.00 | Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 , complete all as specified and directed by Engineer-in-Charge. | 29.76 | CUBIC METRE | 4,000 ₹1.2 L | 4,600 ₹1.4 L | 5,500 ₹1.6 L |
Updated dates
Tender Value
₹43.8 L
EMD Value
₹87,600
Closing Date
3 Jan 2026, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh, Air Force Station Chandigarh-160003
ADDITION/ALTERATION TO STORAGE ACCN OF LGS SECTION AT AF STN CHANDIGARH UNDER GE (AF) CHANDIGRAH
2025_MES_743488_1
GE (AF)/CHD/T-57/2025-26
Open Tender
Civil Works
183 days
Chandigarh
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Chandigarh
₹87,600
Yes
17 Mar 2026
6 Dec 2025
10 Jan 2026
6 Dec 2025
3 Jan 2026
20 Dec 2025
6 Dec 2025 - 13 Dec 2025
Amount
Note :The unit rate quoted by the tenderer under Col No (13) of Sch `A’ (BOQ) unless specifically mentioned otherwise such as labour only/fixing only, for all items of works shall be deemed to be including cost of all materials, labour, tools and plants, testing and commissioning of work in position complete as required for entire completion of work.
Excavating in trenches in soft /loose soil , not exceeding 1.5 m wide and not exceeding 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engrineer-in-Charge.
Returning filling soft/ loose soil in trenches including spreading, leveling in layers not exceeding 25cm thick, watering and well ramming, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates and finished the surface rough to provide adequate bond for the topping as in sub base ,foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete ,100 mm thick (1:2:4) type B-2, using 40 mm graded mechanically crushed stone aggregatesd topping as in sub base finished even & rough to receive the bedding mortar in and including demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge.
Brick work with sub-class `B' bricks old size , straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 in and including demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc for the area where unservicable bricks retrived and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge.
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 , complete all as specified and directed by Engineer-in-Charge.
Use & waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batte etc of rough finished flat surfaces, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves, including sub-ports, overhangs, etc. also splays between floors and beams, etc.; with rough finished surfaces of concrete, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to soffits of suspended slab of concrete such as roof slabs, floor slabs, cover slab, shelve, landings and similar works n.exc 200 mm thick (horizontal or sloping); with rough finished surfaces of concrete, complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 10mm dia and over as in reinforcement cut to length , bent to shape required, including cranking, bending spirally for hooping ends for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90mm dia, complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 5mm dia and over and upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90mm dia. Or securing with clips , complete all as specified and directed by the Engineer in Charge.
Reinforced Cement concrete (1:2:4), type B-0, using 12.5 mm graded mechanically crushed stone aggregates as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete (1:2:4), type B-0, using 12.5 mm graded mechanically crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likes, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Vitrified ceramic tiles (dark Shade) 10 mm thick (square/ractangular) coloured polished tiles, area of each tile not exceeding 0.36 sqm in floors etc. laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white or coloured cement to match the shade of tiles,complete all as specified and as directed by Engineer -in-Charge. Notes :- (i) Design, pattern and colour of tiles will be as approved by GE. (ii) Tile work to be executed in any position or in any patches or as per site requirement.
Vitrified ceramic tiles (dark Shade) 10mm thick (square/ractangular) coloured polished tiles, area of each tile not exceeding 0.36 sqm as in skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed by the Engineer in Charge. Notes :- (i) Design, pattern and colour of tiles will be as approved by GE. (ii) Tile work to be executed in any position or in any patches or as per site requirement.
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) , finished even and smooth without using extra cement for building upto 12 metre height , complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement for building upto 12 metre height , complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing , complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant priming paint, complete all as specified and directed by Engineer-in-Charge.
Preparation of newly plastered surfaces of brick wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489: 2004, alkali & fungal resistant, dirt resistant exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in-Charge. Note: Weather proof exterior emulsion paint shall be of same manufacturer.
Factory made 35 mm thick (Batten thickness) 2nd class hard wood plain, framed, paneled shutters( two number No of panels) with panels of timber flat on both sides (feather edges) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated and detapering from 5 mm to 10 mm around the panel on one side fitted to chowkat, complete all as specified and directed by the Engineer in Charge.
35 mm thick (Batten thickness) Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats , complete all as specified and directed by the Engineer in Charge.
Factory made box type steel window with pintle hinges and two nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer in and including cutting holes in brick walls for inserting holdfasts and making good dismantled portion in cement mortar 1:4 or cement concrete 1:2:4 Type B-1, complete all as specified and shown on Drawing No CEAF/STD-184-2012 Sheets 1/3 & 3/3 and as directed by the Engineer in Charge.
Factory made made box type steel window with pintle hinges and two Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars, including flat iron 12 x 3 mm for securing wire mesh, dovetailed or welded and with one shop coat of zinc chromate primer complete in and including cutting holes in brick walls for inserting holdfasts and making good dismantled portion in cement mortar 1:4 or cement concrete 1:2:4 Type B-1, complete all as specified and shown on Drawing No CEAF/STD-185-2012 Sheets 1/2 & 2/2 and as directed by the Engineer in Charge.
Butt hinges 100 mm size , extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 ISI marked ,complete all as specified and directed by the Engineer in Charge.
Barrel tower bolts aluminum anodizes of extruded section and fixed of 200 mm long size (length of bolt) ISI marked ,complete all as specified and directed by Engineer-in- Charge.
Handles of size 150 mm 'D' type ,extruded aluminium alloy , fabricated type anodized ISI marked ,complete all as specified and directed by Engineer-in- Charge.
Aluminum alloy, anodized, sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed length of bolt 300mm, bolts not less than 12mm dia with and including a minimum of 6 bolts not,four on bolt plate and two on staple plate complete (ISI marked) , complete all as specified and directed by Engineer-in-Charge.
300mm long ordinary rat tail rod pattern Mild steel door springs including roller and roller plate with steel screws or with welding as required at site , complete all as specified and directed by Engineer-in-Charge.
Door seal 50mm wide and 1 m in lenth built in aluminium black plate with nylon brush fixed with screws , complete all as specified and directed by Engineer-in-Charge.
Aluminium body (extruded section) Door closer hydraulically regulated, designation No. 3 , universal type , suitable for door shutters 851 to 1000 mm in width and of weight between 61 to 80 kg and , complete all as specified and directed by Engineer -in-charge.
Sheet glass 4 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane including fixing with glass pins to hold glass in position ,complete all as specified and directed by Engineer-in- Charge. Note:- No extra payment for replacment of damaged wooden beads required for glazing glass in wooden window.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed to steel frames with stainless steel tacks, or stainless steel wire staples, or fixed to wooden frame with first class hard wood bead, ,complete all as specified and directed by Engineer-in- Charge.
Steel water tubing, 15 mm bore medium grade ISI Marked, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors as in concealed or at surface , complete all as specified and directed by Engineer-in-Charge. Note: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
Rotational moulded PVC, tripple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. including ball brass valve of 20 mm bore,high pressure,with polythene float and fly nut ,complete all as specified and directed by Engineer-in- Charge.
Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 15 mm bore dia , complete all as specified and directed by the Engineer in -Charge.
Stop cock /Angle cock, 15 mm bore cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and , complete all as specified and directed by Engineer-in-Charge.
Gyproc GI T Grid system in 600 x 600mm module which includes providing and fixing wall angle along the perimeter of the room with nylone sleeves and wooden screw at 300mm centre to centre. Suspendeding the main Tee of size from the soft, soffit cleat, rawl plugs and wire rod & leveling spring clips at 1200mm centre to centre cross the interlokined into the pre-cut slots in the main Tee at 600mm centre to centre in direction perpendicular to the main Tee to make a grid of 600 x1200mm. 600mm cross Tees are interlocked into pre-cut slots in the 1200mm Tees at 1200mm centre to centre in direction parallel to the main Tee. Cross Tees having length more than 600mm are to be supported indepndently. 9 to 12mm thick aquestic tiles with square Edge of size 595x595mm be placedin the grid of 600x600mm. Size of T-Grid, complete all as specified and directed by Engineer-in- Charge :- (a) Main T- 24x32x0.3mm thick and length 360mm. (b) Cross T-24x25x0.3mm thick and length 1200mm (c) Cross T-24x25x0.3mm thick and length 1600mm (d) Wall angle - 24x24x0.4mm thick and length 3000mm Make:- SAINT GOBAIN or equivalent as approved by Engr-in-Charge.
M S work as Framed works such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes,framed guard bars barred iron doors ladders, framed balusters walk ways railing, framed work of water tanks, framed and hung as gates including pintle hinges, stops, hand made sliding sliding bolts etc ,drilling bolting or reveting etc and similar work conforming (Fe-410,Gde E-250),complete all as specified and directed by Engineer-in- Charge.
Preparation of new or previously untreated wooden surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over one coat of pink primer,complete all as specified and directed by the Engineer in Charge.
Preparation of new or previously untreated steel surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over one coat of red oxide primer,complete all as specified and directed by the Engineer in Charge.
Preparation of new or previously untreated steel surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over previously primed surfaces ,complete all as specified and directed by the Engineer in Charge.
Steel Rolling Shutters of laths thickness 1.25mm, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type, complete all as specified and directed by Engineer-in- Charge.
Ball bearing for rolling shutters, complete all as specified and directed by Engineer-in- Charge.
Point wiring for one light point/fan point controlled by one switch one way drawn through and including non metalic rigid PVC conduit medium duty of 20 mm dia or higher surface/ concealed type with all strandard fittings such as Tee junction, bends etc ,using FRLS PVC unsheathed multistrand copper conductor cable of 1.5 sqmm single core including 3 mm thick plastic laminated sheet cover incl GI sunken terminal box and earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly ,complete all as specified and as directed by Engineer-in- Charge. Note : Wiring shall be done by using proper colour coding.
Point wiring for 15 Amps socket point controlled by one, one way switch using drawn through and including non metalic rigid PVC conduit medium duty of of 20 mm dia or higher with all strandard fittings such as Tee junction, bends etc ,using FRLS PVC unsheathed multistrand copper conductor cable of 2.5 sqmm single core a including 3 mm thick plastic laminated sheet cover incl GI sunken terminal box and earth continuity insulated PVC unsheathed(green colour) 1.5 sqmm copper earth wire connected to common earth dolly ,complete all as specified and as directed by Engineer-in- Charge. Note : Wiring shall be done by using proper colour coding.
Switch piano, flush type single pole, one way 6 Amp , complete all as specified and directed by Engineer-in-Charge.
Switch piano, flush type single pole, one way 16 Amp , complete all as specified and directed by Engineer-in-Charge.
Socket outlet 2 in1, flush type 3 pin,6 and 16 Amp multipurpose, complete all as specified and directed by Engineer-in-Charge.
Ceiling Rose, surface bakelite 65x50 two or three terminal, complete all as specified and directed by Engineer-in-Charge.
Ceiling fan regulator step type electronic for 1200/1400 mm sweep ceiling fan and connecting up ,complete all as specified and directed by Engineer-in- Charge.
MCB SPN, 63 Amps, ,240 Volts ,10 KA 'C' curve type to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs ,complete all as specified and directed by Engineer-in- Charge.
Distribution box Double door type , SPN 4 way,with 200 amps rated bus bar, 240 Volts 50 HZ for MCBs, grouted flush to walls complete with IP 65 and metal double door ,epoxy powder coated with and including MCB SPN, 63 Amps-01 No and MCB SP , 32 Amps-02 No, ,240 Volts ,10 KA 'C' curve type to be housed in DBs of Proper and suitable size cable lugs complete all as specified and directed by Engineer-in-Charge.
Distribution box sheet metal enclosure suitable for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 4 ways with 200 Amp rated bus bar with IP43 protection in and including MCCB FP 100 Amp ,415 volts, 16 KA-01 No and MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA 'C' curve type -12 Nos to be housed in DBs of Proper and suitable size cable lugs ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box sheet metal enclosure suitable for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 6 ways with 200 Amp rated bus bar with IP43 protection in and including MCCB FP 100 Amp ,415 volts, 16 KA-01 No and MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA 'C' curve type -12 Nos to be housed in DBs of Proper and suitable size cable lugs ,complete all as specified and as directed by Engineer-in- Charge.
LED luminaire 600mm x 600mm, 35/ 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver with copper conductor cable of suitable size ,complete all as specified and directed by Engineer-in- Charge.
Ceiling Fan complete with three blade dynamically balanced ,down rod, accessories, 230 volts,1200 mm sweep with squirrel cage copper wound induction motor ,complete all as specified and directed by Engineer-in-Charge.
Exhaust fan, steel body AC single phase 230v of size 380mm sweep 50 HZ ,1200RPM copper windings with blades, frames and louvers, complete all as specified and directed by Engineer-in-Charge.
Point wiring for one light/ fan point controlled by one way flame proof switch complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated FRLS unsheathed 1100 volt grade in and including stove enamelled steel conduit of size 20 mm dia or higher including Tee, junction, bends etc concealed in wall/ fixed on ceiling and including 1.5 sqmm green PVC insulated wire for earth continuity , complete all as specified and directed by Engineer-in-Charge.
Exhaust fan, flameproof steel body AC single Phase, 240V of size 380 mm sweep with, blades and frame and louvers including cutting hole in brick wall, finishing work and 04 Nos 12 mm dia 150 mm long anchor fasteners including making electrical connections , complete all as specified and directed by Engineer-in-Charge.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V , complete all as specified and directed by Engineer-in-Charge.
LED light fitting 2 x 16/20 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with copper conductor cable of suitable size , complete all as specified and directed by Engineer-in-Charge.
Voltage stabilizer of capacity 4 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. Make: V-Guard/ AE/ APLAB/ ANDREW YULE/ VOLINA or any other equivalent make as specified in Appendix of make.
Voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. Make: V-Guard/ AE/ APLAB/ ANDREW YULE/ VOLINA or any other equivalent make as specified in Appendix of make.
Sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc complete with on SP MCB 6- 32 Amps, 'C' curve, 240 volts 10 KA ,complete all as specified and as directed by Engineer-in- Charge.
LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip , ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 35 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes/under culverts etc; including jointing and testing , complete all as specified and directed by Engineer-in- Charge. Note: Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 120 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes /under culverts etc; with and including MS Clamps, nuts , bolts, washers including jointing and testing , complete all as specified and directed by Engineer-in- Charge. Note: Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
Sand cushioning to under ground cable with clean dry river sand in layer of sand 8cm thick before laying of cable and 15 cm after laying of cable, complete all as specified and directed by Engineer-in-Charge. Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
Protection of cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge.
Steel water tubing, 80 mm bore Light grade ISI marked galvanized with all fittings laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc,compllete all as specified and as directed by Engineer-in-Charge.
Boring under road/hard surfaces using any mechanical tools for passing of 80 mm dia GI pipe , without disturbing the road/hard surfaces complete all as directed complete all as specified and directed.
Supply, installation, testing and commissioning of SS encloser of suitable size dust, water and vermin proof duly powder coated , outdoor type with front side openable door suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm thick CRCA Sheet on 50mm X 50mm X 5 mm angle iron frame, angle iron 50 x 50 x 5mm legs 04 Nos of 600mm length for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable all as specified and comprising the following:- (a) MCCB AC, 4 pole, 250 Amps,25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No. (b) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (c) Earthing terminals - 02 No.
Note :Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse.
HARISH SALES CORPORATION (BID ID -3509165)
Anil Kumar Gupta (BID ID -3510131)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
T-57-25-26.pdf
Tender Documents • 1.90 MB
BOQ_832505.xls
BOQ • 0.80 MB
Download all tender documents and submit your bid