Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC MILITARY ENGINEER SERVICES GARRISON ENGINEER EAST JABALPUR 482 011 | L1 | Accepted-AOC Accpeted | |
| 2 | L2₹45.4 L+₹1.7 L (3.91%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹45.5 L+₹1.8 L (4.09%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹45.9 L+₹2.2 L (5.09%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹46.3 L+₹2.7 L (6.13%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
3 Jan 2022, 6:00 pmClosed
CHQ MEG CENTRE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO BRICK WORK PLASTERING FLOORING ROOF AND OTHER MISC WORKS IN OTM ACCN OF CHQ MEG AREA IN THE AOR OF AGE B R MEG UNDER GENORTH BANGALORE
2021_MES_493228_1
8269
Open Tender
Civil Works
Item Rate
120 days
CHQ MEG CENTRE
Class D Category a(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹80,000
Yes
13 Jan 2022
8 Dec 2021
5 Jan 2022
8 Dec 2021
3 Jan 2022
22 Dec 2021
8 Dec 2021 - 21 Dec 2021
Amount
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of brick work / stone masonry / PCC block masonry built in cement mortar of any description all as specified and directed.
Taking down cement plaster of any description hacking for key or raking out joint on old brick work / stone / concrete surfaces all as specified and directed.
Taking up or down 20 mm existing steel tubing and connections all as specified and as directed.
Taking up or down 25 mm existing steel tubing and connections all as specified and as directed.
20mm dia GI tubing medium grade and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
25mm dia GI tubing medium grade and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Dismantling water tanks and removing to store (exc. 250 and not exc. 500 ltr capacity) all as specified and directed.
Dismantling water tanks and removing to store (exc. 500 and not exc. 1000 ltr capacity) all as specified and asdirected.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
All as per Sl Item No. 1.010 above but except tanks. NOTE:- Water tanks as obtained from Sl Item No. 1.008 shall be reused.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs capacity complete complete all as specified and as directed.
All as per Sl Item No. 1.012 above but except tanks. NOTE:- Water tanks as obtained from Sl Item No. 1.009 shall be reused.
20mm dia Ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed in repairs (Min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Dismantling of AC Sheets of any description as in roof covering including ridge, wind tie etc., complete all as specified and directed.
Dismantling single layer Mangalore pattern or similar tiles as in roofing complete all as specified and directed.
Dismantling single layer Mangalore pattern or similar tiles portions bedded in cement mortar.as in roofing complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position in unframed work all as specified and as directed.
All as per Sl Item No.1..021 here in before but in fillets, rails, posts, rafters, purlins, etc. under 40 sq.cm in section all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spacing exc. 15 cm all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Rolled mild steel in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plates of Fe-410W (Gde E-250) complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tenisile strength of 550 Mpa as in roof covering cladding to wall, pre fixed with self taping screwes as specified and as directed.
False ceiling with grid suspended system of size 600 x 600mm with standard sections consisting of main runner 29 x 24.7 x 0.8mm, cross tee 29 x 24.7 x 0.8mm and wall angle 22.2 x 22.2 x0.65mm, ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (main runner, cross tee & wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building boards fixed to false ceiling including taking down old existing ceiling of any description complete all as specified and directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar 1:6 type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
Brick work (except bricks)with sub class 'B' bricks built in CM(1:6), straight or curved on plan exc 6 mtr mean radius, using old size bricks complete all as specified and as directed.
15mm thick rendering on brick work, stone work or concrete surface in cement mortar CM(1:6)finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under relevant items.
Rendering 5 mm thick on surface of brick work/concrete surface in CM (1:3) all as specified surfaces finished even and smooth without using extra cement on ceiling surfaces complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and as directed.
Dismantling of stone set paving of any description or thickness or as in floors, aprons etc., laid bedded and pointed in any cement mortar including removing off the premises complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in levelling course of flooing, 25mm thick complete all as specified and as directed.
Vitrified light coloured ceramic tiles 8 to 10mm thick (square/rectangular) polished, area of each tile not exc. 0.36sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and as directed.
All as per Sl Item No. 1.038 above but as in skirting / dado over 10mm thick backing coat in CM(1:3).
Full bodied vitrified tiles 600x600x10mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and as directed. MAKE:- Endura series of HR Johnson or equivalent of Kajaria/Somany
All as per Sl Item No. 1.040 above but as in skirting / dado.
Plain Cement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in sub base to floors, 75mm thick complete all as specified and as directed.
75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate as in plinth protection, laid in alternate bays (not exceeding 2 sqm each) finished the concrete surface even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and directed.
Exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 300 x 300 x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floors over and including 15 mm thick screed bed in CM (1:6) complete all as specifed and as directed
M-sand spreading and compacting as cushioning material complete all as specified and as directed.
Machine presssd pre-cast concrete interlocking coloured paving block of glass fibre reinfoced glossy finished vibro compacted any shape and size conforming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper of approved tint over a coat of primer on wall complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer all as specified and as directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and providing rendering 10mm thick in CM (1:3) mixed with water proofing compound and over APP modified water proofing membrance, 3mm thick weighing not less than 3.60Kg/sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer / bonding bitumen @ 0.40 Litr/sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm including taking down existing roof treatment of any types with HP clay tiles along with cement plastering and removing of debries to a distance exc. 1.50 Km complete all as specified and as directed.
Plain Cement Concrete, type B0 (1:2:4), using 12.50mm graded stone aggregate as in copings, parapets and railing upto 60cm height, leveling concrete for roof slab, kerbs, water troughs / Chajja and the like including weathering, slightly rounded or chamfered angles and throating all as specified and as directed.
Taking down chowkat (without taking of shutter from the frame) area not exc. 1.5 sqm each including making good the disturbed surface in PCC(1:2:4) type B0 or CM (1:3) all as specified complete all as specified and directed.
Taking down chowkat (without taking of shutter from the frame) area exc. 1.5 sqm and n.exc. 4 sqm each including making good the disturbed surface in PCC (1:2:4) type B0 or CM (1:3) all as specified and as directed.
Powder Coating (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
Powder Coating (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, sliding type, without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified etc. complete all as specified.
Powder Coating (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed '
4mm thick tinted float glass and glazing with oil putty in squares n exc 0.5 sq. m in each pane etc complete all as specified and as directed
5.5mm thick tinted float glass and glazing with oil putty in squares exc 0.5 sq. m in each pane etc complete all as specified and as directed
Aluminium door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed in repairs all as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden surface concrete or brick surrounds. glazed with putty or fixed with beads all as specified.
Sheet glass 4mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane and all as specified.
Karthick Constructions
S S BUILDERS
Atom Engineers and Builders
KRD ASSOCIATE
DESTINY BUILDERS
Eeguchi Constructions
Sreyas Enterprises
J PUSHPALATHA ENGINEER AND CONTRACTOR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .