Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.3 Cr+₹6.7 L (5.33%)Rejected-Finance | ₹1.3 Cr+₹6.7 L (5.33%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.3 Cr+₹7.3 L (5.75%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹1.3 Cr+₹7.3 L (5.75%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹1.4 Cr+₹10.2 L (8.06%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹1.4 Cr+₹10.2 L (8.06%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹1.5 Cr+₹19.6 L (15.5%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹1.5 Cr+₹19.6 L (15.5%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
21 Nov 2024, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN-900386, C/O 56 APO
COMPLETION OF INCOMPLETE/BALANCE WORK FOR PROVN OF EXTERNAL ELECTRIC SUPPLY FOR MAP (PHASE-II) AT NAGROTA
2024_MES_679590_1
87960-A/E8
Open Tender
Civil Works
Item Rate
240 days
Nagrota
AS per NIT
7 documents required · 7 mandatory
₹1,000
GE Nagrota
₹2.2 L
Yes
4 Jan 2025
15 Oct 2024
28 Nov 2024
15 Oct 2024
21 Nov 2024
9 Nov 2024
Amount
Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key scrubbing down with water etc. to receive new plaster etc.; complete all as specified and as directed
Factory made panelled shutter, 35mm thick, 2nd class hardwood, rail and style plain framed, (one panel) without interlocking rail and 12mm veneered particle board with commercial veneering on both faces the size of rail and style as per IS -1003 (Pt-I) kiln seasoned and chemically pressure treated, complete all as specified and directed.
Factory made glazed and skelton shutter, 35mm thick, 2nd class hardwood, open rebated and prepared to receive glass ,gauge etc. ( without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. size of members of shutters as specified in SSR Part-I, section 8 clause 8.20(a), supplied and fitted to chowkhats, complete all as specified and directed.
100mm long, butt hinges (medium weight), colled rolled mild steel fixed with welding, complete all as specified and as directed.
Extruded aluminium alloy handles fabricated type anodised of size 125mm long, 12mm dia, complete all as specified and as directed.
250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Aluminium anodized 150mm long, barrel tower bolt of extruded section and fixed complete all as specified and directed.
Galvanised mild steel wire cloth 0.45mm nominal dia of wire and average width of aperture 1.18mm dia and fixed with tinned tacks or galvanised mild steel staples, complete all as specified and as directed.
Sheet glass, 3.00mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm.in each pane, complete all as specified and directed.
Figured glass, 3.00mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm.in each pane, complete all as specified and directed.
Rendering 15mm thick in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement using water proofing compound all as per manufacture instruction, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately)
Supply only Integral water proofing compound, complete all as specified and directed.
Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of Primer on plastered surfaces, complete all as specified and as directed.
Complete removal of existing treatment on old surfaces on wall and applying two coats of oil bound distempering over a coat of primer after preparation of surfaces complete all as specified and directed.
Preparing new plastered surfaces of wall and applying two coats of cement based paint over a coat of primer, complete all as specified and directed.
Complete removal of exiting treatment on wall and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Preparation of old plastered surfaces of ceiling and applying two coat of white wash, complete all as specified.
Machine cut kota stone flooring, 18-20 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing (mirror finish) (Each stone not less than 55cm x 55cm) over 15mm thick screed bed in CM (1:4) as in floor finished rough including roughening of existing surfaces by pick axicess and applying a coat of cement slurry @ 3 Kg/Sqm of surface, complete all as specified and directed.
Machine cut, kota stone slab 18-20mm thick in skirting, dado and pillar laid and riser of stair case size (0.90-1.00x 18-25cm) jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado, complete all as specified and directed.
40mm thick, PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement, complete all as specified and directed.
Non-skid coloured tiles 400x400x7mm thick as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed or bedding layer of cement mortar (1:4) 15mm thick, complete all as specified and as directed.
25mm thick, PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate, as a sub base to receive topping layer finished even and rough, complete all as specified and as directed.
(450x 300x 7)mm thick coloured glazed ceramic tiles as on walls/ vertical surfaces over 15mm cement rendering in cement mortar 1:4, including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ) , removing serviceable tile to store and rubbish off the premises, complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection (50 mm thick ) finished even and fair, complete all as specified.
PCC (1:3:6) Type C-1, using 20mm graded crushed stone aggregate as in surface channel & drain including form work, complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stop ends etc. complete all as specified and directed.
Rotational moulded polyethene water storage tank triple layer white in colour 500 ltr capacity hoisted and fixed in position including dismantling of existing tank and including PVC float valve 20 mm bore, complete all as specified and directed.
Vitreous China wash basin, white, flat back, size 550 x 400 mm excluding taps, waste pipe and plug and porcelain stopper but including brackets and Coupling, waste pipe etc., fixed in repair complete all as directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe 15 mm bore fancy type, quarter turn type, fixed in repair complete all as per directed
PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed
PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore, complete all as specified and as directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore, complete all as specified and as directed.
PVC (SWR) Bends any radius for 110mm bore, complete all as specified and directed.
PVC (SWR) Bends any radius for 75mm bore with oval access door, complete all as specified and directed.
PVC (SWR) vent cowl 75mm, complete all as specified and directed.
PVC (SWR) vent cowl 110mm, complete all as specified and directed.
PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete, complete all as specified and directed.
Vitreous china squatting pan "Orissa " pattern size 580x440mm white with integral foot rest all as fixed in repairs including ‘P’ or "S" trap including PVC low level cistern of 10 litres capacity including brackets jointing to flush pipe, PVC connection (450x15mm) flushing pipe complete fixed in repair all as directed.
110mm PVC (SWR), WC Connector with lip ring, complete fixed in repair all as specified and directed.
PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate ) 50mm average thickness as in padding finished even and smooth using extra cement, complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including bitumen primer @ 3.5Kg/Sqm, complete all as specified and directed.
APP modified membrane 3mm thick and weighing not less than 3 kg/sqm with 160 GSM/sqm, non woven polyester mat as centre core reinforcement, laid with 75 mm side over lap and 100mm end over lap, the membrane has to be laid with LPG torch and over lap sealed and finished neat over roof including a coat of bitumen 85/25 at the rate of 1.2 Kg per sqm over APP membrane, complete all as specified and directed.
Cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in 75mm thick, complete all as specified and as directed.
Chequered cement tiles concrete 30cm x 30cm x 25mm thick, set jointed in neat cement slurry in floor including 20mm thick screed bed or bedding layer of mortar (1:4), for laying floor finishes etc.; complete all as specified.
Providing and injecting chemical emulsion for Post Constructional Anti termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 ltr per liner mtr including drilling and plugging holes etc.; in apron complete all as specified.
Treating of soil under existing floor using emulsion @ 01 ltr per hole 300mm part including drilling and plugging 12mm dia, holes with cement mortar (1:2) to match the floors complete all as specified and directed.
Tubes medium grade galvanised, 15mm bore, with all fitting and fixed complete to wall and ceilings or laid in floors, complete all as specified and as directed.
Tubes medium Grade galvanised, 20mm bore, with all fittings and fixed complete to wall and ceilings or laid in floors, complete all as specified and as directed.
Bib taps, 15mm bore dia, cast copper alloy chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair, complete all as specified and as directed.
Stop valve (angle valve), 15mm bore dia, cast copper alloy, chromium plated fancy type, screwed down, high pressure, screwed for iron pipe or for fixed unions and fixed in repair, complete all as specified and as directed.
Stop valve, 15mm bore dia, long hank and cup (concealed type), cast copper alloy, chromium plated fancy type, screwed down, high pressure, screwed both ends for iron pipe or for fixed unions and fixed in repair complete all as specified and as directed.
Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed bore dia of pipe 20 mm complete all as specified and directed.
PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and as directed.
Brass chromium plated shower rose, 125mm face dia with swivel joint, complete all as specified.
Point wiring with 1.5 sqmm copper conductor cable (multistranded) PVC insulated FRLS (unsheathed), concealed type, drawn in and including PVC conduit, having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat of red oxide primer on internal and external surface covered with 3mm thick hylam brand IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc.) for one light/ fan point or one bell buzzer point, controlled by one, one way switch, including 1.5 Sqmm PVC insulated copper conductor continuous earth wire, complete all as specified.
Point wiring with 1.5 sqmm copper conductor cable (multistranded) PVC insulated FRLS (unsheathed), concealed type, drawn in and including PVC conduit, having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat of red oxide primer on internal and external surface covered with 3mm thick hylam brand IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc.) for one 3 pin socket outlet, 5 Amp, independent, controlled by one, one way switch, including 1.5 Sqmm PVC insulated copper conductor continuous earth wire, complete all as specified.
Point wring with 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLS (unsheathed), concealed type, drawn in and including PVC conduit, having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat red oxide primer on internal and external surface covered with 3mm thick hylam brand IS-2036 marked laminated sheet cover for one 3 pin socket outlet, 15 Amp, independent , including 2.5 Sqmm PVC insulated copper conductor continuous earth wire complete all as specified.
Switch piano flush type single pole, one way, 5 Amps, 240 Volts complete all as specified.
Switch socket outlet, 3 pin, 5 Amp, flush type complete all as specified.
Switch socket outlet flush type multi purpose 3 pin, 15 Amp, and three pin 5 Amp controlled by one switch complete all as specified.
Ceiling rose, surface Bakelite 65 x 50mm three terminals complete all as specified.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
Fixing only Ceiling Fan, 1200mm sweep, any make and type with regulator and connecting up including provision of cable 3 core flexible copper conductor 23/0.0076 from ceiling rose to ceiling fan and testing, complete all as specified and as directed. Note : Ceiling fan with down rod and regulator shall be issued under Sch 'B' free for fixing.
Fixing only exhaust fan 300 mm sweep, AC, 230/ 250 volts heavy duty complete with louvers/shutters, mounting on walls with holding down bolts, nuts, washers embedded in PCC 1 :2:4 blocks 150x 150x 150mm & provision of flexible copper conductor cable three core 23/0.0076 size from ceiling rose to fan and testing, complete all as specified. Note : Exhaust fan with louver shall be issued under Sch 'B' free for fixing only.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Sub main wiring with two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth and earth dolly complete all as specified and directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
Sheet metal enclosures for MCB DB SPN, 8 way, double door type with 200 Amp rated busbar 240 Volts, complete all as specified.
Miniature circuit breaker (MCB), SPN, 32 Amp, 240 Volts, 10KA.
Miniature circuit breaker (MCB), SP, 6 amp to 32 Amp, 240 Volts, 10KA.
Cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified.
Cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in benching, coping around the pole (above GL) and the like including weathering, slightly rounded or chamfered angles and fair finishing the exposed surfaces of concrete using extra cement complete including necessary form work, complete all as specified.
Sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. Note :- For measurement purpose punned thickness 18 cm shall be considered.
Un-reinforced precast concrete cable cover, class HV, type-I, laid flat, size 300mm x 180mm x 40mm, compete all as specified.
Un-reinforced precast concrete cable cover, class LV, type-I, laid flat, size 250mm x 140mm x 40mm, compete all as specified.
Mild steel galvanised Stay assembly set complete comprising of 20 mm dia 400 mm long stay bow, 1800mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length all as shown in electrical plate No-1 of MES Schedule Part-I, 2009 (Specification), complete all as specified and directed.
Galvanised stay strands of size 7/4mm complete all as specified.
Loop type insulator, vitreous porcelain, white, brown or green, small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified.
Fixing only, galvanised steel tubing, light grade, 50mm bore laid in trenches or fixed to wall/pole with fittings are required for cable protection complete all as specified. Note : GI Pipe light grade shall be issued under Schedule 'B' Free for fixing.
Fixing only, galvanised steel tubing, light grade, 40 mm bore laid in trenches or fixed to wall/pole with fittings are required for cable protection complete all as specified. Note : GI Pipe light grade shall be issued under Schedule 'B' Free for fixing.
HT Danger notice plate of size 25 X 20 cm & 1.6mm thick mild steel, sheet vitreous enamelled white with letters figures in English, Hindi or Urdu and conventional skull and bones in signal red colour and fixed with MS clamp bolts and nuts of approved size complete all as specified and as directed.
LT Danger notice plate of size 20 X 15 cm & 1.6mm thick mild steel, sheet vitreous enamelled white with letters figures in English, Hindi or Urdu and conventional skull and bones in signal red colour and fixed with MS clamp bolts and nuts of approved size complete all as specified and as directed.
Anti-climbing device, spikes type fabricated out of MS bars (round, square and flate) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of pole, complete all as specified and directed.
Aluminium conductor steel reinforced (ACSR) of any size as required at site, stretching on LT/HT poles without any kinks and binding with and including aluminium binding wire of suitable cross sectional area (but not less that 16 SWG) including line connector vice type having two brass plate bolts and nuts etc.; or compression crimping type conductor sleeve joint for jointing of equal or unequal size or jumpers, connection and including treatment of ACSR conductor with conducting jelly, complete all as specified.
Switch air break, gang operated, triple pole, mechanical operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers "NAVTAL LOCK" consisting of mild steel channel, operating roof 20mm dia, 'medium grade' IS: 1018 of 1972 for current rating 400 amps, 11000 volts grade, complete all as specified.
Switch air break, gang operated, triple pole, mechanical operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers "NAVTAL LOCK" consisting of mild steel channel, operating roof 20mm dia, 'medium grade' IS: 1018 of 1972 for current rating 200 amps, 11000 volts grade, complete all as specified.
Single Pole, for outdoor use Air break (switch) isolator suitable for 200 Amp, 11000 volts complete all as specified.
Lightening arrestor, Metal Oxide, complete with all fittings, distribution class, discharge capacity 65 kA, 11000 volts grade, complete all as specified.
Laying, jointing, testing and commissioning of aluminium conductor 11000 Volts, XLPE insulated PVC inner sheathed , GI strip or wire armoured and overall PVC sheathed cable of size 300 Sqmm, 3 core, laid in trenches/ on surface of wall/ in GI pipe/ in Hume pipe including dressing and clamping the cable with MS Zinc Passivated clamps, providing cable identification markers etc., complete all as specified. Note:- Cable shall be issue under Sch 'B' free for fixing.
Laying, jointing, testing and commissioning of aluminium conductor 11000 Volts, XLPE insulated PVC inner sheathed , GI strip or wire armoured and overall PVC sheathed cable of size 185 Sqmm, 3 core, laid in trenches/ on surface of wall/ in GI pipe/ in Hume pipe including dressing and clamping the cable with MS Zinc Passivated clamps, providing cable identification markers etc., complete all as specified. Note:- Cable shall be issue under Sch 'B' free for fixing.
Laying, jointing, testing and commissioning of aluminium conductor 1100 Volts, XLPE insulated PVC inner sheathed ,GI strip or wire armoured and overall PVC sheathed cable 300 Sqmm, 3.5 core, laid in trenches/ on surface of wall/ in GI pipe/ in Hume pipe including dressing and clamping the cable with MS Zinc Passivated clamps, providing cable identification markers etc, complete all as specified of following size:- Note:- Cable shall be issue under Sch 'B' free for fixing.
300 Sqmm x 3.5 core
185 Sqmm x 3.5 core
150 Sqmm x 3.5 core
50 Sqmm x 3.5 core
16 Sqmm x 4 core
Indoor/outdoor cable and terminal joint of size 300 Sqmm x 3.5 core, any type complete suitable for aluminium conductor cable and testing after jointing complete all as specified for the following sizes of cable :- Note:- Joint kit shall be issue under Sch 'B' free for laying.
Indoor/outdoor cable and terminal joint of size 185 Sqmm x 3.5 core, any type complete suitable for aluminium conductor cable and testing after jointing complete all as specified for the following sizes of cable :- Note:- Joint kit shall be issue under Sch 'B' free for laying.
Indoor/outdoor cable and terminal joint of size 150 Sqmm x 3.5 core, any type complete suitable for aluminium conductor cable and testing after jointing complete all as specified for the following sizes of cable :- Note:- Joint kit shall be issue under Sch 'B' free for laying.
Cold shrinkable cable end termination joint for indoor/outdoor installation for 3 core XLPE cable with aluminium conductor 11000 volts grade ( earthed) of cross sectional area 300 sqmm complete kit with all accessories and jointing material and testing after jointing, complete all as specified and as directed. Note :- Joint shall be issued under Sch 'B' free for laying.
Cold shrinkable cable end termination joint for indoor/outdoor installation for 3 core XLPE cable with aluminium conductor 11000 volts grade ( earthed) of cross sectional area 185 sqmm complete kit with all accessories and jointing material and testing after jointing, complete all as specified and as directed. Note :- Joint shall be issued under Sch 'B' free for laying.
Supply and spreading of 40mm graded crushed stone aggregate upto 80 mm depth in transformer / four pole structure yard of 11 KV Sub Station after cleaning and levelling of surface complete all as specified.
Supply and spreading of 20 mm graded crushed stone aggregate upto 80 mm depth in transformer / four pole structure yard of 11 KV Sub Station after cleaning and levelling of surface complete all as specified.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 15mm bore up to 5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exceeding 50m, testing on completion complete all as specified & directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 40mm bore up to 5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exceeding 50m, testing on completion complete all as specified and directed.
Aluminium strip of size 25 x 3mm for earth continuity conductor or main earthling lead, fixed to wall or on batten or recess or chases or buried in ground or drawn in conduit/ pipe or for loop earthling and making earth bus with nut, bolts and washers as required, complete all as specified and as directed.
Mild steel framed work as in grills, gratings. etc. with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters , walk ways, railing , framed work or water tanks and similar work conforming to Fe290 Gde-E-165, complete all as specified and directed.
Steel tubular swaged poles truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, final taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410-SP- 55 (11 m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and two coats of black bituminous paint internally & portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately, and marking pole No. with black paint at suitable height complete all as specified and directed. Note:- Steel tubular swaged poles shall be issued under Schedule 'B' free for fixing.
Laying, jointing, testing and commissioning trenches/ducts or fixing to Pole/wall or passing through pipe XLPE insulated screened PVC bedded galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm, 2 core complete all as specified. Note:- Cable shall be issued under Schedule 'B' free for laying.
Bus bar chamber, 2 strip,100 Amp, IC 300 mm long including connection and clamps, nuts, bolts suitable for fixing on GI pipe, complete all as specified.
Cable joint kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 300 Sqmm, 3 core, XLPE armoured aluminium conductor cable complete all as specified and directed. Note:- Joint shall be issued under Sch 'B' free for laying.
Cable joint kit for 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 185 Sqmm, 3 core,XLPE armoured aluminium conductor cable complete all as specified and directed. Note:- Joint shall be issued under Sch 'B' free for laying.
Straight through joint suitable for LT underground cable, including joint kit for making joints for 1100 Volts, 3.5 core, 300 Sqmm cable complete ail as specified and directed.
Straight through joint suitable for LT underground cable, including joint kit for making joints for 1100 Volts, 3.5 core, 185 Sqmm cable complete ail as specified and directed.
Straight through joint suitable for LT underground cable, including joint kit for making joints for 1100 Volts, 3.5 core, 150 Sqmm cable complete all as specified and directed.
Laying only Straight through joint suitable for LT underground cable, including joint kit for making joints for 1100 Volts, 3.5 core, 50 Sqmm cable complete ail as specified and directed. Note:- Joint shall be issued under Sch 'B' free for laying.
Test Point terminal block made Gun metal or Phosphorus bronze size 75x75x25 mm drilled and screwed including 3 no's, 8 mm dia and 25 mm long hexagonal head screw, complete all as specified and directed.
Porcelain, vitreous, disc type insulator, white, brown or green, 145mm high and 255mm dia, ball and socket type, single disc assembly for tension with tension clamps for conductors, suitable for 11 KV working pressure system with all mild steel galvanised fittings, complete all as specified.
Aluminium strip 25mm x 3.15mm with saddles duly fixed on porcelain/ceramic insulator and fixing screws etc. for roof conductors and down conductors above ground complete, all as specified and directed.
Air termination, single pointed aluminium rod 12mm dia and 300 mm long, complete all as specified and directed. Note: The unit rate includes the cost of aluminium base plate of size 125mmx125mm x 10mm fixed over hylum sheet of size 175mm x 175mm x 10mm fixed on roof top.
Earth continuity conductor or main earthling lead fixed to wall on baton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation to loop earthling and making earth bus with nuts bolts and washers as required, 4mm dia galvanized iron or steel wire complete all as specified and directed.
Installation, testing and commissioning of four panel 11 KV VCB board, extendable on both sides suitable for indoor installation having to less that IP-42 protection for use on 11KV 50 c/s earthed system having a symmetrical breaking capacity of 18.4KA for 1second at 11KV comprising triple pole VCBs. Panel shall be equipped with following accessories including breaker maintenance trolley and as per specifications and schematic drawing complete all as required:- (a) Metal clad housing with truck having 800amp TP horizontal isolation, horizontal draw, out trip free VCBs having a symmetrical breaking capacity of 18.4 kA for 1 Sec at 11KV with manual/electrical operating mechanism (230V, AC, spring charging motor) as required. (b) Air insulated copper conductor bus bar chamber - 01 set. (c) Isolating plug and receptacle -01 set. Note:- 11KV panel (04 Nos) already at site. Minor repair and spares shall deemed to be included in the quoted rate. Contractor shall visit the site before quoting the rate. (ii) 11KV VCB (04 Nos) extendable on both side shall be issued under Sch 'B' free for fixing.
Supply, installation, connecting, commissioning and testing of 24 volt, DC, 250 AH sealed maintenance free tubular lead add batteries along with battery charger (IGBT based full wave rectifier) with auto/manual trickle-cum-boost charging facility complete including one No distribution board having 250 amps FP MCCB as incoming and suitable No's of 20/16 Amps DP MCB's (DC duty) as outgoing complete all as required, complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m Fire retardant/extinguishing electric insulated, 2mm thick synthetic mat, complete all as specified and directed.
Factory made cable route indicator using PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregate of size 40cm X 15cm at bottom and 15cm X 15cm at top and height 50cm duly engraved "HT/LT route" and duly painted with synthetic enamel paint of brown colour complete all as specified and directed.
Testing and installation of 2 x 200 KVAR fix type capacitor bank rated at 12 KV, 3 phase, 50 Hz with barrel fuses 20 amps, 11KV including 2 No's dry type series reactor, 12 KV insulation cabinet with suitable cable entry, complete all as specified and as directed. Note : 2 x 200 KVAR fix type capacitor bank shall be issued under Schedule 'B' free for fixing.
LED flood light, 120 watt, 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed
Post top lantern, LED type, 40 watt, 230 watt, volts AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Fibre glass, discharged rod, PVC coated suitable for 33 KV,complete all as specified.
Mild steel work for posts and struts in fencing including cutting tops to shapes as required, drilling holes, notching for wire etc.; including all necessary drilling, bolting or reverting confirming to Fe-290 Gde E-165, complete all as specified.
Supply only chain link fencing, of 4mm dia, galvanised steel wire, (100mm x 100mm) mesh, complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire, complete all as specified.
Mild steel screw bolts (machine made) ,with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed, end to be fitted with washers and one hexagonal or square, nut, length of bolt exceeding 5cm and not exceeding 10cm, dia of shank 12m, complete all as specified and as directed.
Mild steel TMT bars 8mm dia, for stretching chain link fencing, at top and bottom, complete all as specified and as directed.
Two coats of synthetic enamel paint over a coat of red oxide primer on steel surface exceeding 10cm in width or girth including preparation of surfaces, complete all as specified.
RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in foundation including rafts, footings, beams, plinth beams/band, bases for columns etc., and mass concrete etc.; complete all as specified and directed.
RCC M-25 (Design mix) using 20mm graded crushed stone aggregate, as in columns, pillars, piers, posts and struts etc., complete all as specified.
Mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip, complete all as specified and directed.
All as per Srl item No. 136 here-inabove but 5mm dia and over upto and including 10mm dia, as in stirrups, spacers, binders etc., complete all as specified.
Form work to sides of pillars, posts, struts, pilers, columns and stanchions etc.; for rough finished surface concrete, complete all as specified.
Rendering 5mm thick cement plaster on fair faces of brickwork or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified.
100mm thick, PCC 1 :2:4 Type B-2, using 40mm graded crushed stone aggregate, as in floors/Paths laid in alternate, panels finished even and fair including spike rolling to surfaces or making impression of expanded metal, whilst the concrete is green, complete all as specified.
Preparing new surfaces of walls and applying two coats of cement base paint, complete all as specified.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out, in any type of soil, complete all as specified.
Excavating in trenches, not exceeding 1.5m wide and depth exceeding 1.5m but not exceeding 3.0m in depth and getting out, in any type of soil, complete all as specified.
Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified.
Excavation in post holes (or similar holes) in any type of soil, each not exceeding 0.50 cubic metre, getting out returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50 metre and making good surfaces, complete all as specified and directed.
Continental Enterprises (BID ID -3165674)
Sant Construction Co. (BID ID -3165204)
MAMTA ENTERPRISES (BID ID -3164608)
Flint India (BID ID -3162366)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .