Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.5 L+₹5.8 L (15.1%)Rejected-Finance BIRD LINE CALICUT POST SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance NOT Being L1 | |
| 3 | L3₹47.2 L+₹8.5 L (22.0%)Rejected-Finance | L3 | Rejected-Finance NOT Being L1 | |
| 4 | L4₹48.1 L+₹9.4 L (24.4%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance NOT Being L1 | |
| 5 | L5₹48.6 L+₹9.9 L (25.7%)Rejected-Finance 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-Finance NOT Being L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
2 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minnniebay
GE Minniebay Jugnlighat Post Minniebay Port Blair 744103
ADDN ALTN AND RENEWAL OF OLD VINTAGE HT FOUR POLE STRUCTURE TO 11KV RMU AND OTHER CONNECTED WORKS UNDER AGE EM-I AT GE MINNIE BAY PORT BLAIR
2024_MES_639993_1
8363/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹83,000
Yes
23 Mar 2024
31 Jan 2024
4 Mar 2024
1 Feb 2024
2 Mar 2024
18 Feb 2024
Amount
Taking down/dismantling old vintage HT four pole structure and connected fitting fixture complete with necessary T&P complete all as specified and as directed by Engineer-in-Charge.
Disconnecting/taking down of existing old vintage HT VCBs (03 Nos) and 01 No 3 way RMU safely by disconnecting the HT cable with out any damage and shifting the same to MES store within 1km radius complete with necessary T&P and transportation complete all as specified and as directed by Engineer-in-Charge.
Supplying, Installing, testing & commissioning of Factory Made, Floor mounted, 11 KV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorised, Outdoor extensible type, 8 Way RMU Consisting of 5 Nos. VCBs as Incoming and 3 Nos. of VCBs as Outgoing with SCADA Compatible complete all as specified and as directed by Engineer-in-Charge. Make of RMU : ABB/ SIEMENS/ SCHNEIDER
[A] RMU shall be floor mounted, 11 KV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor extensible type, RMU with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations at a height up to altitude 1000 Meters above sea level and Ambient Temperature range from 5ºC to 50ºC without any de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2.0mm thick SS 304 Grade filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67, Switchgear Operating Mechanism shall have minimum IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars.There should be temperature sensor at each cable side bushing for breaker and VCB. The gap between the coupled RMU's must be within 10 mm. Temperature data to be monitored at local or remote scada level through frtu.communication between sensors and gh Data concerntrator should be wireless. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU’s must be within 10mm.
[B] Each Vacuum Circuit Breaker [VCB] shall be comprising of the following: [i] 11 KV, 630 Amps, 21 kA/ 3s, 3 Pole Motorised VCB (Non draw out type) with 3 pole manual disconnector and 3 pole manual earth switch, Motorized Spring Assisted Mechanism and Series Trip Coil – 1 No. [ii] Self Powered Relay with O/C, S/C, E/F Protection. Relay shall have a Front USB for Laptop Interface, LCD Display, 10 Event Records, 5 Fault Records, min 2 setting group and keypad for setting parameters for the relay – 1 No [iii] Resin Cast ring core Protection CT, Plate mounted type : 100-50/1A, 5P10, 2.5 VA-01 Set. [iv] Resin Cast ring core Metering CT, Plate mounted type : 100-50/1A, Cl. 1.0, 2.5 VA-01 Set. [iv] Live Cable Indicator with indications at the Front and Three Inlets to check the Synchronization of Phases – 1 No [v] Making capacity - 52.5 kAp [vi] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set [vii] Cable Termination Cover Boots [Push on type] – 1 Set
[viii] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations , 100 Electrical Operations at rated current.
[C] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set [i] Air Insulated Enclosure with necessary Bus Connection – 1 No [ii] PT 11KV / √3 / 110V / √3, 50 VA, Class-1.0 – 1 Set [iii] Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 1.0 / 0.5] with RS485 Port for Communication in Modbus Protocol. - 01 Set [iv] R / Y / B Indicating Lamps – 1 Set [v] 11 KV / 230V AC, Class 1, 500VA Control Transformer – 1 No [vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC] – 1 No [D] Space Heater with thermostat [E] 2 x 8 Window Alarm Annunciator and Hooter. FPI to be provided in Isolator(Load break switch) chamber and ensure VI,FPI and FRTU ,RMU shall be of same make for ease of integration to layers. [F] Self Powered FRTU to detect Short Circuit and Earth Fault on the Cable System, Fault indication through LED Lamps, Reset through Remote and Local. As a minimum, the FRTU shall be capable of performing the following functions: [i] Suitable for Acquiring Analog values from Multifunction Transducers or alternatively through Transducer – less modules and the status inputs of devices from the substation, processing and transmitting to Master stations.
[ii] Have required number of commnication ports for simultaneous commnication with master stations (s), MFTs. [iii] FRTU shall have the capability of Automatic Start-Up and initialisation following restoration of Power after an outage without need of manual intervention. [iv] Suitable Communication with at least Four Master Stations simultaneously on IEC 60870-5-104 [v] FRTU shall have one TCP/IP Ethernet Port for communication with Master Station[s] using IEC 60870-5-104 Protocol. [vi] Connection with adjacent modules shall be direct through busbar via metering bushing or through MV cables. VT’s and CT’s from the manufacturer conforming to IEC 61869-2 and IEC 61869-2 respectively shall be accepted.
Notes: [a] An operator situated in front, lateral and rear [A-FLR 21 kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switch board during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum 3 Way / 3 Function RMU. [b] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable.
[c] Construction of Plinth / Foundation for 11KV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation and shall not be paid as extra on this account. The foundation shall consists of Two Parallel Brick Walls built using bricks straight or curved on plan to any radius built in Cement Mortar 1:6 of length 2.10m, suitable thickness and height as per the manufacturer’s instructions over PCC Concrete Bed of 150mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled, over 150mm thick Sand Bed, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including earthwork excavation of pit size 2.10 X 1.20 X 0.60 Metres complete all as per manufacturer’s recommendations, drawings, as specified and as directed.
[d] The rate quoted is also deemed to be including the cost of disconnection of HT Cables up to 3 Core, 240 Sq.mm from existing 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed by the Engineer-in-Charge. [e] End termination joints shall be measured and paid separately. [f] The make of RMU/ VCB/ vacuum interrupter/ Relays/ FRTU offered shall be of same make.
(g) The Contractor shall submit GA drawings of RMU for approval of GE before placing order. The Contractor shall make all necessary arrangements for pre-despatch inspection at manufacturer site or e-testing as directed by Accepting Officer and for pre-commissioning test by rep nominated by HQ CE (A&N) Zone through Accepting Officer after installation of RMU. The cost for the same is deemed to be included in quoted rate. (h) The quoted rate is inclusive of carrying out servicing, relay calibration & injection testing by service engineer of OEM once in 11 months during defect liablity period.
M & L for shifting of HT UG cable from structure to RMU and cleaning of existing duct and properly securing of shifted cable insdie duct complete all as specified and as directed by Engineer in Charge. Note : Necessary earthwork shall be measured and paid separately.
Supply, laying and testing of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor,11 KV grade (Earthed system cable) of size 3 core 95sqmm complete all as specified and as directed by Engineer-in-Charge. Note:- (a) Earth work, sand cushioning, Precast concrete cable covers, GI pipe protection for road crossings, HT termination joints shall be measured and paid separately. Note : Necessary earthwork shall be measured and paid separately.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination , cold shrinkable shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminium conductor cable of size 95 sqmm to120 sqmm complete all as specified and as directed by Engineer in Charge..
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint, cold shrinkable shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, Aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and as directed by Engineer in Charge..
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25M deep below GL) with top edge of earth plate not less than 1.5M below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed by Engineer-in-Charge. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All acessories required for galvanished steel plate electrode required as specified and directed.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) complete all as specified and as directed by Engineer-in-Charge. Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying un-reinforced Precast Concrete Cable cover factory made as per IS 5820-1970, class HV, type 1, size 300mm x 180mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
M & L for cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of Road repair Bitumen mix with graded aggregate as per Manufacturer's instruction and laying in appropriate temperture complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 100mm bore GI tubing light grade ISI marked with requisite fittings laid in trenches or crossing roads/paths/culverts/along poles/walls complete all as specified and as directed by Engineer-in-Charge. Note : Necessary earthwork shall be measured and paid separately.
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5m wide and not exc 1.5m in depth for foundation, pipe, laying of cable etc not exc 10 Sqm on plan and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
DELTA ELECTRICALS
bansal construction
Sree Tirumala Enterprises
Gulmarg Electrical Service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .