| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC RIDMALSAR PUROHITAN BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹43.7 L+₹15.5 L (55.2%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹44.3 L+₹16.2 L (57.3%)Rejected-Finance | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹46.3 L+₹18.1 L (64.4%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender | |
| 5 | L4₹46.3 L+₹18.1 L (64.4%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 May 2023, 6:00 pmClosed
GE AF TA Gwalior
GE AF TA Gwalior 474020
REPAIR TO DESTRESSED MEMBERS, ROOF TREATMENT INCLUDING EXTERNAL PERIODICAL TO OTM BLDGS IN TECH AREA AT AF STN GWALIOR
2023_MES_590999_1
8900/1465/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
AF STN Gwalior
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF TA Gwalior
₹90,000
Yes
10 Jul 2023
24 Apr 2023
6 Jun 2023
24 Apr 2023
29 May 2023
15 May 2023
Amount
Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed.
All as per item No 2 here-in-before but, except brick using old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed.
M&L in repair for 15mm thick rendering fare face of brickwork or concrete surfaces in CM 1:4 finished even and smooth (without using exrtra cement)etc complete all as specified and directed.
M&L in repair for 15mm thick rendering other than fare face of brickwork or concrete surfaces in CM 1:6 finished even and smooth (without using exrtra cement)etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for PCC (1:2:4) type B0, using 12.5mm graded stone aggregate as in cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs including necessary form work complete all as specified and directed by Engr-in-Charge.
Demollition of cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for complete all as specifeid and directed.
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in shelves, chajja , etc including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like for etc including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Columns, pillars, piers, posts including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
S&F mild steel TMT bars of 10 mm dia and over cut to length, bent to shape as required including cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia for securing with clips complete all as specified and directed.
Same as per item No above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for removing/chipping 40 to 60 mm depth of existing loose concrete carefully by manual or low impact frequency hammer without damaging the existing concrete including cleaning the surface by compressed air jet complete including removing loose concrete around the reinforcement. The debris will be disposed up to lead of 500m. The entire surface will be checked by light hammering (using 1 kg hammer) for detection of loose concrete. All loose/hollow sound concrete around corroded reinforcing bars has to be removed to prepare well defined patch all as specified and as decided.
M&L for drilling hole in RCC/Bricks structure using drilling machine up to a depth of 150 mm depth or half the thickness of member (whichever is less) and removing dust, etc by vaccum cleaner and blowers, providing and fixing of 12mm dia Polytetrafluoroethylene (Teflon) nozzes @ 750 mm c/c in both direction and inject cement slurry by using OPC 43 grade cement mixed water in the ration of 1:2 (01 part cement and 02 part water ) and removal of excess cement slurry and nozzles carefully after grouting complete all as directed.
M&L for cleaning of rusted reinforcement of total rust including from behind the reinforcing bars to give it totally rust free finished steel surface, by manual methods and using approved alkaline chemical rust remover (Pidilite/FOSROC/CICO/Thermax as per specification) as per approved paint Brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and following it to dry and clean with dry cloth before application of protective coating etc complete all as specified and directed.
M&L anticorrosive treatment to exposed reinforcing bars in two coats as per specifications using approved Zn rich epoxy phenolic rebar protection product (Pidilite/CICO/Forsroc/ Thermax ) complete all as specified and as directed
M&L for providing and applying concrete Penetrating Corrosion Inhibitor (CPCI) as per specification in two coats @ 4 Sq mt / ltr/coat of approved brand (CICO/Thermax/ forsroc Specification ) on areas demarcated specifically complete all specified and directed.
M&L for applying a coat of structural grade single/ two component epoxy bonding agent of approved brand (Pidilite/CICO/FOSROC as per Specification) conforming to ASTM C - 881 - 13 Type - II tested as per ASTM - C 882 - 13 or granolithic E-resin based solvent free concrete bonding agent of mix density of chemical 1.45 to 1.50 kg/ltr) with a bond strength specified in ASTN C - 881 - 11 of Make Thermax etc. to ensure bond between old and new concrete prior to application of any type of mortar/ concrete complete all specified and directed
M&L for polymer modified mortar to build the profile of structural members upto 40 to 60 mm depth by using (i) emulsified SBR latex (Thermax/Pidilite/CICO/FOSROC as per manufacturer's specifications) conforming to ASTM C - 1059 - 13 Type - II in damaged areas (1 cement conforming to OPC 43 grade - 3 part graded cleaned river sand conforming to Zone - II grade of IS : 383 + 20 % latex by weight of cement) with 0.35 water/ cement ratio, in 15-20 mm thick layers by applying bond coat (Payable under BOQ item no. 7 above) between successive/ each layers, or or (ii) rheoplastic non shrink corrosion resistant, high strength compound BS 66 (BS 66 micro concrete mix with cement ratio 1:4 using OPC 43 grade cement) of Make Thermax/ Chemco system etc by confirming to the required compressive strength and expansion characteristics specified in ASTM C 109, ASTM C 348, ASTM D 469, ASTM C 827 - 1987 complete all as specified and as per manufacture instruction. Note - (i) Placing of the materials shall be using suitable arrangements such as pumping device for uniform flow of materials and providing side shuttering if required. (ii) Curing shall be done as per manufacturer instructions and all as directed
Filling the cracks in isolated placed (other than the locations mentioned above) of columns, beams after opening up in "V:" groove manner covering the area of 300 mm from central line of crack with the depth of 50 mm ,with components of compound specified in Make : Thermax or equivalent in CICO/ FOSROC/ PIDILITE.
M&L for Providing, cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges and padding over roof surfaces etc complete all as specified and as directed.
M&L for Cement concrete tiles 20cm x 20cmx 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in roofs, and pointed in neat cement slurry with grey cement and no pigment over 15mm thick screed bed in CM 1:4 including dismentling of existing tiles with screed without disturbing the roof treatment/ bitumenous felt complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Applying hot blown grade bituminen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap by aithorized applicators. Make: IWL India Ltd / STP / Pidilite Industics Ltd etc (e) Applying a coat of Alluminium Paint over APP Membrane.
S&F in repairs 150mm dia PVC (SWR) pipes single socketed in any length at any height with rubber ring joints fixed to walls/ hanger cladding with necessary brackets including tee and bends.
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismentling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Ridge, valley/ gutter fixed with self tapping screws including Dismentling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for 5mm thick rendering on concrete surfaces as in celinig in CM 1:3 finished even and smooth without using extra cement incl taking down cement plaster on concrete surface incl preparation of newly plastered surface and applying three coats of white wash complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using exrtra cement) including taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash by the use of rollers complete all as specified and directed.
Ditto as per item above but one coat of white wash on ceiling surface complete all as specified and directed.
M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coats exterior weather proof Paint by the use of rollers including filling cracks/depressions with putty to make the adjacent surface even and smooth complete all as specified and directed. [Make:-'APEX' of M/s Asian Paints or equivalent in M/s Berger as approved by GE].
M&L for Preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparing old painted steel & iron surfaces of any description n.exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of surfaces of wood and wood based materials of any description, width or girth including cleaning and a coat of wood filler on old works and applying french polish in one or more coats to the required texure and glossy finish complete all as specified and directed.
M&L for prepration of old decorated Brick tile /Concrete tiles (Chequered / interlocking tiles) cleaning by any means, and applying one coat of floor tile paint any colour with spray gun/compressor complete all as specified and directed as approved by Engr-in-Charge. Make: INDOGO Floor Paints or Apex Floor Guard of Asian Paints
M&L for preparation of old painted surface and applying one coats of aluminium paint on steel surface of any description over 10cm in width or girth completed all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats exterior weather proof Paint (Make : APEX of Asian Paints or equivalent in Berger Paints etc), by the use of rollers over a coat of primer white or tinted as approved complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces applying two coat of external emulsion paint/weather coat, in camouflaging pattern on CCD scheme (Pattern as approved by GE) by the use of rollers on surfaces of any type of building, wall, any surfaces, any height, over a coat of primer complete all as specified and directed. Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account. (Make : Apex of Asian Paints or equivalent in Berger Paints etc)
M&L for applying one coat of external emulsion paint/weather coat, in camouflaging pattern on CCD scheme (Pattern as approved by GE) by the use of rollers on surfaces of any type of building, wall, any surfaces, any height, incl preparation of old decorated surfaces complete all as specified and directed. Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account. (Make : Apex of Asian Paints or equivalent in Berger Paints etc)
M&L for Preparation of newly Plastered surfaces and applying two coats of white wash complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emultion (Make : ACE of Asian Paints or equivalent in Berger Paints etc) white or tinted by the use of rollers over a coat of primer as approved complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of distemper oil emulsion white or tinted by the use of rollers over a coat of calk whiening primer (preparatory to distempering) as approved complete all as specified and directed.
Removal of defective concrete, cleaning the surface thoroughly, applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound in the proportion as per manufacturer's instructions or as directed, sand and coarse aggregates confirming to IS:383 and table 1 of IS:9012 respectively, water cement ratio ranging from 0.35 to 0.5, density of gunite not less than 2000 Kg/cum, strength not less than 25MPa (40mm average thickness) complete all as specified and directed.
Guniting concrete surface with cement mortar (25mm nominal thick) applied with compressor after cleaning surface and spraying with epoxy complete all as specified and directed.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. Make :- Havells/KEI/Anchor
All as per item No 50 here-in-before but cable of size 6 Sqmm FRLS with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. (Note : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit. Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.) Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.) Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.) Make :- Havells/KEI/Anchor
Supply, fixing, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed.Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 63 Amp MCB complete all as specified and directed..Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) 125 Amp complete with one TPN 125 Amp MCB complete all as specified and directed. .Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) complete with one TPN 40/63 Amp MCB complete all as specified and directed. Make :-.Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed..Make :- Legrand/Havells/C&S or equivlant
All as per item 61 here-in-before but distribution board single pole and neutral, 12 way .Make :- Legrand/Havells/C&S or equivlant
All as per item 61 here-in-before but distribution board single pole and neutral, 8 way .Make :- Legrand/Havells/C&S or equivlant
All as per item 61 here-in-before but distribution board single pole and neutral, 4 way .Make :- Legrand/Havells/C&S or equivlant
Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed. Make :- Legrand/Havells/C&S or equivlant
All as per item 65 here-in-before but distribution board VTP & N 8 ways (TPN MCB DB) for TP-MCCB upto 160 Amps. Make :- Legrand/Havells/C&S or equivlant
All as per item 65 here-in-before but distribution board TP & N 12 ways (TPN MCCB DB) for TP-MCCB upto 160 Amps. Make :- Legrand/Havells/C&S or equivlant
All as per item 65 here-in-before but distribution board TP & N 8 ways (TPN MCCB DB) for TP-MCCB upto 160 Amps. Make :- Legrand/Havells/C&S or equivlant
S&F MCCB, 3 pole, 250 Amps current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. .Make :- Legrand/Havells/C&S or equivlant
All as per item 69 here-in-before but MCCB, 3 pole, 160 Amps current rating and ultimate breaking capacity Icu = 16 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 69 here-in-before but MCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity Icu = 16 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 69 here-in-before but MCCB FP, 100 Amps having current rating 16 KA Make :- Legrand/Havells/C&S or equivlant
All as per item 69 here-in-before but MCB TPN, 63 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 69 here-in-before but MCB TP, 40 Amps (`C’ series) having current rating 10 KA . Make :- Legrand/Havells/C&S or equivlant
S&F MCCB, 4 pole, 125 Amps,415 volt current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCB SPN, 40 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCB SPN, 32 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
Supply and fixing in repair 8 Watt Recess mounted fixed LED down light made of extruded aluminium housing and high power LED as light source with diffuser and driver complete all as specified and directed by Engr-in-charge. Make :- Havells CAT Part No SPARLEPROFIXDLR8W830MOD or equivalent to Philips/Oshram.
Supplying, fixing in repair & testing decorative recess mounting 36 watt LED full out put luminaries suitable for Armstrong ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Bajaj cat part No BZRSQL 36W GZ1 NW "SKYLUX' Racess mounted 2x2 LED or equvlent Philips/CG
Supply& Fixing in repairs LED Batten fittings 20/22 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 20W , D532065 of Wipro or Eq model of Philips/Osram
S&F in repair Ultra bright glass 20W LED tube light with driver and high efficiency suited for installation in exsiting T8 fitting with G13 lamp holders complete all as specified and directed. Make :-Havells Cat part No -CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips/Oshram
Supply and fixing 18 Watt ultra bright PL-L LED suitable for four pin lamp holder alongwith in built surge protection of 3KV complete all as specified and directed. Make WIPRO/Havells/Philips
S&F in replacement 8 Watt LED bollard light with uniformly lit diffuser and IP-65 protection including necessary concreate work complete all as specified and directed Make :- Cat Part No CONEBL8WLED857PSYMTOPC of Havells or equivalent in Oshram/Philips
S&F in repairs 18 W LED Driver suitable for PL-LED four pin lamp complete all as specified and directed by Engr-in-charge. Make: CG/Havells/Philips
Taking down carefully earth strip alumium of any size and any type from any height (3m to 16 m) of building or hangar ( roof conductor and down conductor) of Lightning protection and refixing the same with necessary insulators complete all as specified and as directed.
All as per above item but Air Termination rod of any size
Taking down carefully any light fitting from ceiling/wall and refixing the same along with necessary wires and fittings complete all as specified and as directed
All as per above item bu Celing fan of any make and capacity
Dismantling and taking down the serviceable Air Conditioner of 1.5/2/3 TR indoor and out door unit with voltage stabilizer and refixing the same at directed location complete all as specied and as directed. Note: 1. Proper pumping down of refrigirant is the responsiblity of the contractor. Any topping up of refrigirant gas required is included in the quoted rate, 2. Necessary insulation required for copper pipe is included in the quoted rate.
Sunil Traders
m/s vikash Engineers
NITIN TRADERS
SHRI RAM CONSTRUCTION
Ganga and Sons
R.B. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .