Loading…
Loading…
Tender Value
₹68.6 L
EMD Value
₹1.4 L
Closing Date
14 Sept 2026, 5:00 pm4d left
MUKESH KUMAR
SUPERINTENDENT ENGINEER
PATNA
MUKESH KUMAR
SUPERINTENDENT ENGINEER
CONSTRUCTION OF 35 CRPF (REMAINING WORK) AT LARAIYATAND IN PLACE OF PESRA IN THE DISTRICT OF MUNGER WITH ELECTRIFICATION
139346
NIT-20/2026-27/GR-01
Open Tender
GENERAL
Patna
• Legal Status of Bidder
• Place of Registration
• Litigation History
• Registration No
• PAN No.
• GSTIN
• Character Certificate (with Letter No. Letter Date, Issuing Office)
• Electrical License Validity upto (in case of sub-contractors affedevit of both the parties)
• NOC for Debar (if required)
GENERAL
PERCENTAGE
L1
1
21 documents required · 21 mandatory
₹10,000
Processing Fee: 1180
₹1.4 L
3 Sept 2026
3 Sept 2026
15 Sept 2026
3 Sept 2026
14 Sept 2026
3 Sept 2026
Cause of Dispute
Owned/Leased / to be procured
Year of Experience (General)
Owned / leased / to be procured
Sub-contractor( Name and Address)
DESCRIPTION
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Half brick masonary with bricks of class designation 100A in foundations and plinth in : Cement mortar 1:3 (1 cement :3 coarse sand ) in super structure and extra for providing and placing in positin two nos 6mm dia M.S. bars at every third course of half brick masonary ( with F.P.S. bricks)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Rajnagar plain white marble /Udaipur green marble/Zebra block marble:Area of slab over 0.50 sqm.
Providing and fixing flush door shutters conforming to IS : 2202 (Part-I) non-decorative type.core of block board construction with frame of 1st class tiard wood and well mathched commercial 3 ply veneering wiih vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing steel glazed doors, windows and ventilatrs of standard rolled steel sections,joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with steel beading of approved shape and section with screw insted of glazing clips and special metal-sash putty of approved make complete including applying a priming coat of approved steel primer: including the cost of metal beading and other fitting except necessary hinges or pivots as required: Steel windows
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying a priming coat of approved steel primer:G.I. Pipes 40 mm nominal bore (class - B)
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Chequerred precast cement concrete tiles 22 mm thick with marbie chips of size 6 mm in footpath & coutyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning tec. Complete on 20 mm thick bed of cement mortar 1:4(1 cement:4 coarse sand) : Dark shade using ordinary cement.
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4: 20 to 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 sqm.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying primer coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood):Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Renewing glass panes and refixing existing wooden fillets:Float glass panes of thickness 4 mm(weight not less than 10kg/sqm)
Extra cost of brick 100A (a) Munger Zone
Extra cost of slag cement (b) Munger Zone
Carriage of materials including loading, unloading, transporting and stacking at site as per specification and direction of E/I (a) Bricks (lead 1km Kachha + 7km Pucca)
Do-do- (b) Coarse sand ( Lead 58 Km from Lakhisarai river to work site)
Do-do- (c) Local Sand ( 1 Km. Kutcha + 2 Km. Pucca)
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Supplying all tools, labour and cutting chhaja, cornice or laying PVC pipe and making good the same as per specification and direction of E/UI
Making holes in wall for laying P.V.C.. Pipes and restoring the same after pipe laying as per specification and direction of E/I. (a) 250mm thick wall
Making holes in wall for laying P.V.C.. Pipes and restoring the same after pipe laying as per specification and direction of E/I. (b) 125mm thick wall
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS :7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete,including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20 mm diameter round bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
Per bag
DESCRIPTION
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 32 mm nominal outer dia Pipes
Providing and fixing brass bib cock of approved quality :15 mm nominal bore
Providing and fixing brass stop cock of approved quality :15 mm nominal bore
Providing and fixing brass stop cock of approved quality :20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore:Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore:Vertical
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
DESCRIPTION
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Per bag
DESCRIPTION
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Brick work with bricks of class designation 100A in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Per bag
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required. (a) Group B
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X2.5 sq. mm + 1X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. 4 X 6 sq, mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. 4 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing stepped type electronic fan regulatoron th existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' 250 A, 50 KA, FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' I25 A,16 KA, TPMCCB
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required. 100A
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required. 31s/300 A
Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required. 250 A
Suppling and fixing following way horizontal type three pole and neatrel, sheet steel, M.C.B., distribution board, 415 Volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnection, powder painted including eathing, etc. as required (But without MCB/RECB./ Isolator) 4 way (4+12) single door horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supplying and fixing following rating four pole, 415 voltas Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Supplying and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connecion with copper thimble excavation and refilling etc. as required.
Providing and fixing 4.0 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and fixing 4'X18 wat[ LED batten with minimumefficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.18 watt
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.90 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and upto 95 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.50 sq. mm, 3.5 core
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
Providing and fixing 4.0 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing of lightning conductor final made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes tec. Complete as required.
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For Horizontal run)
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For vertical run)
TOTAL Rs P
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
e NIT 20 2026-27.pdf
NIT • 2.29 MB
SPECIALCONDITION.doc
NIT • 0.07 MB
GR-01 TECH 20 2026-27.xls
NIT • 0.04 MB
GR-01 BOQ 20 2026-27.xls
NIT • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .