| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.4 L+₹2.1 L (6.34%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹35.3 L+₹2.9 L (9.08%)Rejected-Finance COLABA MUMBAI | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹36.5 L+₹4.1 L (12.6%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹36.6 L+₹4.2 L (13.0%)Rejected-Finance | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
13 Jan 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIRS AND REPLACEMENT OF BER TRANSFORMER AT NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2023_MES_632613_1
8167/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar
Class D Category b (ii)
7 documents required · 7 mandatory
₹500
Yes
GE (NW) Navy Nagar
₹79,000
Yes
26 Feb 2024
14 Dec 2023
15 Jan 2024
14 Dec 2023
13 Jan 2024
8 Jan 2024
14 Dec 2023 - 21 Dec 2023
Amount
Supply, installation, testing and commissioning of Transformer double wound, step down, 11000/433 volts, oil type, minimum 630 KVA capacity or next nearest higher capacity as per OEM design, conforming to Energy Efficency Level -I as per amendment No 04 of IS Code 1180 (part-I) : 2014, ONAN, Dyn 11, core type with copper conductor.Transformer shall be provided with Off circuit Rotary type tap switch so as to provided for a voltage adjustment on H.V, from +5% to -5% (in step of 2.5%) of rated voltage of 11000 volts in 4 equal steps (5 position) to obtain rated voltage of 433 volts on LV side including cable box on LT and HT side, with 12 KV system highest voltage at HV side, 28 KV (rms) HV power frequency, 75 kVp HV impulse withstand voltage, trasnformer shall be designed for losses as per IS 1180 (Part-3) : 2021 and for 110% continuous overfluxing withstand capaibility, complete with first fill of new transformer oil having dielectric strength not less than 60 KV, suitable mounting arrangement complete and other standard accesssories : (a) 12kV off circuit tapping switch. b) Oil conservator tank with drain plug and filling cap. c) Silica gel dehydrating breather charged with silica gel d) Oil level gauge. e) Oil filter valve. f) Oil drain valve. g) Thermometer pocket (with oil temp. indicator) h) Diagram and rating plate. j) Two earthing arrangements.k) Lifting lugs. l) Four bidirectional plain roller m) Air vent plug. n) Explosion vent. o) Cable box on H.V side. p) Cable box on L.V side. q) Additional neutral terminal brought outside the LV cable box for earthing. r) HV&LV cable boxes. s) Buchholz relay. t) Radiator valves. u) Oil temp. indicator. v) Winding temp. indicator w) Magnetic oil level gauge. x) Inspection Cover. y) marshalling box. all as per IS:1180 (Part 3) : 2014-2021 specification.
Supply and fix cable jointing kit, End Termination Joint indoor for 11KV (earthed) grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 95 to 185 sq mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for earthing complete with copper earth plate electrode 600 X 600 X 3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to copper earth strip 25 X 3 mm by means of bolts, nuts and washers of copper or brass upto the test point all as shown in electrical plate No.3 of SSR Part-I connected to Existing earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
RAVINDRA BROTHERS
Veer High Tech Solution
Chakshu Enterprise
C S Sharma and Co
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .