Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.2 L+₹1.6 L (3.60%)Rejected-AOC NO 23 GURUNAGAR 2ND STREET NARAYANAPURAM MADURAI 625 014 | MADURAI | TAMIL NADU | 625014 | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | RAJAHARI CONSTRUCTION L2 | E D R CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.01 | Dismantling RCC by manual/ by using deploying
machineries etc., complete. | 9 | m3 | 4,775.3 ₹42,977.7 | 4,609.4 ₹41,484.6 Lowest |
| 2.01 | Removing the burst R.C.C. pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
700mm Psc Pipe | 2 | No | 12,702.3 ₹25,404.6 | 12,260.9 ₹24,521.8 Lowest |
| 3.01 | 300mm Psc Pipe | 1 | No | 5,064.8 ₹5,064.8 | 4,888.8 ₹4,888.8 Lowest |
| 4.01 | Supply of M.S. PIPES- SPIRAL/LONGITUDIDNAL WELDING AS PER IS 3589/2001 WITH INTERNAL LINING AND EXTERNAL COATING MADE WITH FE410, Bare etc., complete.
711 X 14.2 mm M.S Pipe | 10 | Rm | 27,256.7 ₹2,72,567 | 26,309.6 ₹2,63,096 Lowest |
| 5.01 | 323.9X7.1 mm M.s Pipe line | 15 | Rm | 8,597.5 ₹1,28,962.5 | 8,298.7 ₹1,24,480.5 Lowest |
| 6.01 | 508x11mm M.sPipe | 10 | Rm | 8,597.5 ₹85,975 | 8,298.7 ₹82,987 Lowest |
| 7.01 | Supply of 700mm ,300mm Sluice Valves & Specials related IS Specifications etc., complete
700mm Sluice Valve | 2 | No | 3,61,211 ₹7,22,422 | 3,48,659.3 ₹6,97,318.6 Lowest |
| 8.01 | 500mm Sluice Valve | 1 | No | 1,69,379.1 ₹1,69,379.1 | 1,63,493.3 ₹1,63,493.3 Lowest |
| 9.01 | 300mm Sluice Valve | 2 | No | 52,800.6 ₹1,05,601.2 | 50,965.8 ₹1,01,931.6 Lowest |
| 10.01 | 250 mm - 300mm dia Socket | 42.5 | K.g | 154.4 ₹6,562 | 149 ₹6,332.5 Lowest |
Tender Value
₹44.6 L
EMD Value
₹44,572
Closing Date
25 Sept 2025, 3:00 pmClosed
The Commissioner Madurai Corporation
Aringar Anna Maligai , Thallakulam , Madurai
Removing and refixing new 700mm,300mm sluice valve and special in vaigai water supply pipe line 2
2025_MAWS_603670_1
E7 / EST. 267 / 25-26
Limited
Civil Works
Lump-sum
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹44,572
16 Oct 2025
13 Sept 2025
25 Sept 2025
13 Sept 2025
25 Sept 2025
13 Sept 2025
Amount
Dismantling RCC by manual/ by using deploying machineries etc., complete.
Removing the burst R.C.C. pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers 700mm Psc Pipe
300mm Psc Pipe
Supply of M.S. PIPES- SPIRAL/LONGITUDIDNAL WELDING AS PER IS 3589/2001 WITH INTERNAL LINING AND EXTERNAL COATING MADE WITH FE410, Bare etc., complete. 711 X 14.2 mm M.S Pipe
323.9X7.1 mm M.s Pipe line
508x11mm M.sPipe
Supply of 700mm ,300mm Sluice Valves & Specials related IS Specifications etc., complete 700mm Sluice Valve
500mm Sluice Valve
300mm Sluice Valve
250 mm - 300mm dia Socket
250 mm - 300 dia Flange
500 mm - 600 mm dia Socket
500 mm - 600 mm dia Flange
700 mm - 750 mm dia Socket
700 mm - 750 mm dia Flange
500mm D.I Flanged Pipe (3.00 M)
Quicke Setting Cement ( This Data already Approved 2015 , If Current Year The Rate increase Every Year of 2% So =160 *20% =32.00 =Say =192.00)
Lead Wood ( This Data already Approved 2015 , If Current Year The Rate increase Every Year of 2% So =650 *20% =130.00 =Say =780.00)
Hump Yarn ( This Data already Approved 2015 , If Current Year The Rate increase Every Year of 2% So =160 *20% =32.00 =Say =192.00)
Hire charges for deploying earth moving machinery (JCB/Poclain) for earthwork including diesel, oil and labour charges etc., complete.
Dewatering using 3HP to 70HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (5HP)
Hire charges for portable Genset 1.00 KVA with 2 Nos. of 150W flood light including all incidental charges, transportation, crew charges and fuel charges etc., complete.
Hire charges for Welding Plant 11 KVA ,Cutting Machine including the material of Welding Rod, Cutting Whell and labour charges, transportation charges etc., complete.
Removing The Damaged 700mm, 300mm Sluice Valve, Butter Fly Refixing The New 700mm ,300mm, Including Rubber Sheet Bolt Nut Vaser, The rate include the cost of all labour and material charges etc., complete.
Removing The 600mm ,450mm Damaged Sluice Valve spindle Rod , Shutter , Check Nut , Bold, Nut , & Rubber Vasor, and Refixing 600mm,450mm Sluice Valve All Specials Cutting , Therading, Grinding , Welding, inculding Labour charges & Transporting Charges Etc .Complete.. ( The Rate Original TWAD 450 mm Sluice Valve Data Rate Based 30 % Rate of the Repairing Work .) =163526 x 30% = 49057.80
Constrution of Valve champer in Earth Work , Pcc 1 : 4 : 8 , Shutering Side , MS Grill , RCC 1 : 1.50 : 3 , In Valve Champer size in 2.00m x2.00m x 2.00m including Labours, loading & Unloading Charges Etc Completed.
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished.500mm
Add GST 18%
RAJAHARI CONSTRUCTION (BID ID -1466074)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .