Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-Finance | L1 | Accepted-Finance Lowest one | |
| 2 | L2₹33.4 L+₹2.3 L (7.37%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.6 L+₹4.6 L (14.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.7 L+₹6.6 L (21.3%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.7 L+₹6.7 L (21.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹87,400
Closing Date
9 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
ADDITION ALTERATION TO BOUNDARY WALL OF ADITI AHILYA COMPLEX AND REPAIR TO VALLEY GUTTER IN PARKING SHED AT NT POOL AND PROVISION AND INSTALLATION OF FLAME PROOF LIGHTS LIGHT IN INS SHIKRA COLABA MUMBAI
2023_MES_609643_2
8208
Open Tender
Civil Works
Item Rate
180 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹87,400
Yes
11 Oct 2023
11 Sept 2023
11 Oct 2023
11 Sept 2023
9 Oct 2023
25 Sept 2023
11 Sept 2023 - 18 Sept 2023
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
Demolition brick work or stone/boulder masonary built in cement mortar and removing the rubbish outside MD land complete all as specified & directed.
M & L Stone Masonary Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as specified & directed.
M&L 15 mm Thick Rendering in cement mortar (1:4), on fair faces of brick/stone work and finised even and smooth without using extra cement , complete all as specified.
Preparation of new plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade over a coat of external primer, complete all as specified and directed.
M&L RCC nominal mix 1:1.5:3 type B1 (using 20 mm graded stone aggregate) as in band, lintel, plinth courses, string courses, parapet and railing, bed plates and similar work complete all as specified and directed.
M&L for from work to edges of concrete flats, treads, break in floors, window cills, concrete railings openings in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces of concrete complete all as specified and directed.
M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking ,bending , binding with MS wire not less than 0.9 mm dia (annealed) complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description, complete all as specified.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors, (ornamental and intricate design) and similar work conforming to Fe.290,Gde-E-165, complete all as specified.
Preparation of new steel surfaces & apply two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified.
M&L 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills, cooking platforms, working table, wall clading and like over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding and rounding all as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, any description including Nainital or similar pattern roof coverings or as in valley gutter complete all as specified and directed.
S&F Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Fixing only Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
S&F Plain galvanised mild steel sheeting 1.25 mm thick in ridges hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and opening for rain water pipe to be provided fixed with MS Flat complete all as specified and directed.
S&F flat iron for Bands, straps, supports or stays for rainwater, valley gutter, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges large hasps and staples, chains,hand made sliding bolts, clamps,hold fasts, wall ties, hooks for hanging fans plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three way straps, plate washers and similar small articles and straps to be screwed, ends including keys to MS angle or the like item conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Taking down rain water pipes/PVC pipes/cemented pipe (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc complete all as directed and specified.
S&F 160mm bore PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shade and complete all as specified and directed.
S&F 160mm PVC (SWR) bends any radius fixed to pipe & including scaffolding upto 5 th floor of building complete all as specified.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 290, Gde -E - 165 upto 5th floor of bldg complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc upto 5th floor of bldg complete all as specified and directed.
M&L for Rendering 15mm thick cement plaster in cement mortor 1:4 on brick or concrete surfaces mixed with water proofing compound @ 2% by the weight of cement in patches, surfaces to be finished even and smooth without using extra cement, complete all as specified and directed. Note:- WPC shall be measured and paid seperately.
Supply only Integral water proofing compound.
M & L for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including in stove enameled PVC casing and caping of suitable size, ISI marked with accessories concealed in wall/ceiling/truss etc with stove enameled PVC conduit ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for the following :-
(a) One light point controlled by one switch SP one way.
(b) One fan/exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
M & L for Point wiring complete with 2.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including in stove enameled steel conduit of suitable size, ISI marked with accessories concealed in wall/ceiling/truss etc with stove enameled steel conduit ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dolly for the following :-
Flame proof One 3 pin socket outlet 16 Amps on Independent board with other switches. Make : CG/Baliga/Sudhir/Bharat
Supply and fix LED 1 x 20 W flame proof fittingwith all accessories . Make : CG/Baliga/Sudhir/Bharat
Supply and fix flame proof high speed operation, excellent cooling efficiency, low maintenance exxhaust fan 300 mm sweep , 1400 RPM with louver complete all as specified. Make : CG/Baliga/Sudhir/Bharat
Supply and fix flame proof switch/socket combination 16 Amp in LMA cable termination box in LMA 6, 16 A 230 Volt complete all as specified and directed. Make : CG/Baliga/Sudhir/Bharat
Supply and flame proof switch rotary type 06 Amp fix to wall complete all as specified and directed. Make : CG/Baliga/Sudhir/Bharat
Supply and fixing flame proof distribution board of size 275 mm x 275mm x 130 mm including MCB SPN 63 Amps - 01 Nos , MCB SP 10 Amps -06 Nos at nearest site suitable for in coprating MCB SPN & SP Etc Make : CG/Baliga/Sudhir/Bharat
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Two runs of 4 Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping Make of wire - Polycab / Finolex / Havells . Make of casing caping - Pressfit / Precision
Material and Labour point wiring for Geyser /AC complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing and caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing and caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
Supply and fix Modular Switch, 6Amp, One way, 1 module. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix support function blank plate single, 1 module complete all as specified and directed.
Supply and fix Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed . Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.
Supply and fix Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix Modular white cover plate with Frame 2 Module complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular white cover plate with Frame 3 Module complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular white cover plate with Frame 4 Module complete all as specified and directed.Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix Modular white cover plate with Frame 6 Module complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular white cover plate with Frame 8 Module complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 2 module including cutting and chassing complete all as specified and directed. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 3 module including cutting and chassing complete all as specified and directed Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 4 module including cutting and chassing complete all as specified and directed Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 6 module including cutting and chassing complete all as specified and directed.Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 8 module complete all as specified and directed Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix baton intergrated LED channel 1x20WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed . Make : Havells/Philips/Jaquar
Supply and fix Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners.
Supply and fix sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make: ABB, Strandred/ Legrand
MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand Equivalent in siemens/Standard/ Havells
MCB SP 6-63 Amps, 240 Volts - 10 Nos Make - Legrand Equivalent in siemens/Standard/ Havells
SHRI SAI ENTERPRISES
Bright Construction Co
Unitech Enterprises
RAJU AND COMPANY
SHREE JAGDISH FURNITURE CO.
dimalsonsdecorator
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .