Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹29.9 LAccepted-AOC 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | ₹29.9 L | L 1 | Accepted-AOC As per the chart generated L1 is accepted and AOC issued to L 1 |
| 2 | L 2₹34.6 L+₹4.7 L (15.6%)Rejected-Finance | ₹34.6 L+₹4.7 L (15.6%) | L 2 | Rejected-Finance Second Least |
| 3 | L 3₹34.9 L+₹5.0 L (16.8%)Rejected-Finance | ₹34.9 L+₹5.0 L (16.8%) | L 3 | Rejected-Finance Third Least |
| 4 | L 4₹36.1 L+₹6.2 L (20.8%)Rejected-Finance 12 MARIAMMAN KOIL STREET MUTHULINGAMPET LAWSPET PUDUCHERRY 605008 | PONDICHERRY | PUDUCHERRY | 605008 | ₹36.1 L+₹6.2 L (20.8%) | L 4 | Rejected-Finance Forth Least |
Tender Value
Refer Docs
EMD Value
₹76,942
Closing Date
28 Jan 2021, 4:00 pmClosed
Executive Engineer, Electrical Division, PWD, Pudu
Executive Engineer, Electrical Division, PWD, Puducherry.
Sub work. Supply, erection and testing of octagonal Galvanised iron poles with LED fittings for the Vambakeera palayam road from Grand canal to Pondy Marina road in Puducherry.
2021_PWDC1_7569_1
11/EE(E)/SBDI/2021
Open Tender
Electrical Works
Item Rate
90 days
Puducherry
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
₹76,942
13 Jun 2022
21 Jan 2021
29 Jan 2021
21 Jan 2021
28 Jan 2021
21 Jan 2021
Amount
Supplying of 8m high Hot Dip Galvanised Octagonal pole with bottom 135mm A/F, top 70mm A/F made up of 3mm thick.HT sheet steel plate along with 225 x 225 x 16mm base plate and having 1000mm long single arm bracket made up of 48mm dia, Bakelite sheet with single pole MCB & stud terminals( for mounting inside the base compartment of pole), Supply of 4 nos. M20 x 700mm long "J" type foundation bolts (EN 8 grade).(Make:Bajaj/ Orient/Phillips).
Supply and fixing of 120W LED with lens outdoor streetlight fixtures on existing poles including all accessories for retrofitting, IP 65/66 white colour with necessary over voltage, under voltage and surge protection with three years onsite warranty for replacement/ Rectification. Make:Philips/ Havells/ Bajaj/ LED GEO.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required - 1 X 1.5 sqmm(Make – Finolex / Polycab).
Supplying of 4 x 25 sqmm sizes of PVC armoured aluminium U.G cable – 1.1KV grade. (Make – Finolex / Polycab).
Supplying of 4 x 6 sqmm sizes of PVC armoured copper U.G cable – 1.1KV grade. (Make – Finolex / Polycab).
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC / HUME / METAL pipe as required - upto 35 sq.mm
Supply, erection,testing and commissioning of one no of SMC Box (Make: Sintex) with metering and Timer panel board for the power supply to over all size 850mmx350mmx250mm made out of Glasswool with resin material. The front side top portion have energy meter with viewing glass with 10mm hylem sheet. The bottom side compartments with 40-63A rating, TPN MCB,C'series 10KA breaking capacity (Make-Siemens/ABB),1No of Timer switch (Daily) along with battery backup to 200hrs (Make -L&T-Kagger/Legrand-Lexic),1no.60A power conductor (Make-C&S/L&T),1no of toggle switch (Make-C&S). The switch units are to be fixed with in the allotted size in the 10mm hylem sheet. The bottom sheet of the shell should be of PVC thick roll sheet for cable entry. The panel has to be mounted 75mmx75mm 6mm MS 'L angle on the floor with in the height of 600MM.Interior connection between the switch fuse units are to be done with 2.5/6.0/10.0Sqmm ISI marked, FR PVC insulated,single core copper conductor cable.(Make-Finolex/Polycab) The door should be flush type inter locking in one position. The panel provided with removable type pland plated to the bottom and with sufficient holes of required diameter. Earth work excavation of foundation trench of size 1.00mm x 0.6mm x 0.60m and filling river sand for depth of 0.10m and P.C.C1:2:4(1cement:two coarse sand:4graded stone aggregate of 20mm nominal size) of size 1.00mm x 0.60x1.00m.The cost should be inclusive of minor modification suitable for site condition as approved by the Engineer-in-charge.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required - 4 X25 sq.mm
Supplying and making end termination with copper gland and copper lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required: 4 x 6 Sq.mm.
Supplying and laying of 40 mm dia. GI pipe medium class
Spring PVC hose 20mm
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation including form work etc as required
Supply of 6SWG G.I Wire
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 meters
Kumar Electricals Service
Thirumalai Enterprises
PURODHA ELECTRIC CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .