Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.0 L+₹46,321 (1.89%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹25.5 L+₹92,835 (3.78%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹27.0 L+₹2.5 L (10.00%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹28.6 L+₹4.0 L (16.5%)Rejected-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L5 | Rejected-Finance High Rate |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
8 Oct 2022, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8308 REPAIR REPLACEMENT OF INTERNAL ELECTRIC WIRING FITTINGS FIXTURES AND CONNECTED ELECTRICAL ITEMS AT MARRIED ACCN FOR OFFRS JCOS ORS AND SERVENT QTRS AND DAY TO DAY MAINT WELCOME MAINT FOR INTERNAL EM SERVICES FOR CERTAIN ACCN IN AFMC AREA UNDER
2022_MES_552687_1
8308 REPAIR/REPLACEMENT OF INTERNAL ELECTRIC WIRIN
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹77,000
Yes
7 Dec 2022
17 Sept 2022
10 Oct 2022
17 Sept 2022
8 Oct 2022
1 Oct 2022
Amount
S&F in repairs Modular Switch flush type, single pole, one way, 6/10 Amp complete.
S&F in repairs Modular Switch flush type, single pole, one way, 15 Amp/ 16 Amp complete.
S&F in repairs Modular Switch flush type, single pole, two way, 6/10 Amp complete.
S&F in repairs Bell push modular 6 Amps complete all as specified.
S&F in repairs Modular Socket outlet multipurpose 6 Amps - 2/3 pin combined flush type complete.
S&F in repairs Modular Socket outlet multipurpose Socket 6Amp/ 16 Amp - 2/3 pin combined flush type complete.
S&F in repairs modular step type fan regulator single module 230 Volt 50 HZ AC supply complete.
S&F in repairs modular step type fan regulator two module 230 Volt 50 HZ AC supply complete.
S&F in repairs Switch piano flush type, single pole, one way, and 5 Amp complete
S&F in repairs Switch piano flush type, single pole, two way, and 5 Amp complete
S&F in repairs Bell push 6 Amp 230 volt 50 HZ AC supply complete
S&F in repairs Switch piano flush type, single pole, one way, and 15 Amp complete
S&F in repairs Socket outlet multipurpose 2 in 1, 3 pin, 5 Amp flush type complete
S&F in repairs Socket outlet multipurpose 2 in 1, 3 pin, 5 Amp and 15 Amp, flush type complete
S&F in repairs Switch socket combination multipurpose 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete
S&F in repairs Switch socket combination multipurpose 2 in 1, 5 Amp flush type universal complete
S&F in repairs ceiling fan regulator socketed, stepped type, flush type,230 volts AC supply complete
S&F in repairs Ceiling rose, surface Bakelite 2 to 3 terminals ISI marked for batten fitting complete all as specified
S&F in repairs Lamp holder, PVC/Polycarbonate type with back plate complete all as specified.
S&F in repairs Bell Electric Ding dong type 230 volt 50 Hz AC supply complete all as specified.
S&F in repairs capacitor 2.5/3.15/4.0 MFD 230 Volt, AC supply complete
S&F in repairs Plug top 3 Pin 15 Amp, 230 Volt AC supply complete
S&F in repairs PVC surface modular box of size up to 6 module with modular plates inner and outer with each terminal including necessary fixing arrandements complete.
S&F in repairs PVC surface modular box of size 8 to 12 module with modular plates inner and outer with each terminal including necessary fixing arrandements complete.
S&F in replacement LED Tube light fittings wall/Ceiling mounted, 20 Watt LED 6500K with Ultra bright LED Polycarbonate Tube-light with very high efficiency provided with high efficient integral constant current LED Driver 230 Volt, etc. complete with mounting batten including all accessories internally pre-wired and including provision of new multistranded copper conductor of suitable size from ceiling rose to fitting complete all as directed
S&F in replacement for wall mounted 20 Watt indoor batten with opal diffuser, IP 20, with minimum 3 hrs back up with output of 1800 lumens, powerful lithium battery, box type light fitting, 230 Volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, including provision of new multistranded copper conductor of suitable size from ceiling rose to fitting complete all as directed.
S&F in replacement wall/ceiling mounted LED batten tube 10 Watts, light fitting, with out put of 1000 lumens, 230 Volts with extruded aluminium housing with decorative end caps and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, including provision of new multistranded copper conductor ceiling rose to fitting including LED tube 2' x 10 Watts complete all as directed.
Fixing only in replacement LED Tube light fitting 4 feet long 18/20 Watt complete all as directed. Note : Tube light fitting shall be issued under Schedule ‘B’ free for fixing only.
S&F in replacement LED Security light of luminaires 24 Watt complete with all accessories and including wall mounting bracket of suitable size including clamps, nut bolts etc. including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to light fitting including necessary 40 mm bore dia GI pipe light grade bracket 0.6 to 0.9 mtr long bend to required shape with clamps, nut, bolts complete all as directed.
S&F in replacement Energy saving new generation environmental friendly long life versatile 30 Watt energy efficient LED security light in Pressure die cast housing, top maintainable, with clear PC, higher efficiency secondary moulded lens with inbuilt Lithium battery pack for power back upto 2 hours, IP-66. Luminaire should be complete with Isolated electronic constant current driver efficiency, RTC enabled for automatic switch ON/OFF of light fitting suitable for operating in voltage range 140 Volt to 270 Volt, inbuilt internal surge protection device and necessary mounting arrangements and provision of 1.5 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary 40 mm bore dia GI pipe light grade bracket 0.6 to 0.9 mtr long bend to required shape with clamps, nut, bolts complete all as directed
Taking down unserviceable ceiling/ Exhaust fan from its original position dismantling blades, fan and blades and deposited to MES Store for further disposal complete. Note : RV to be obtained after handing over the fan to MES store yard of AGE E/M.
Hanging only repaired/new ceiling fan/exhaust fan of any make and size held by occupant complete.
M & L for Sub main wiring with approved colour coding as per IS with 2 single core 1.5 Sqmm PVC insulated FRLS multistranded copper conductor and drawn through surface PVC conduit and its accessories including one run of PVC insulated 1.5 Sqmm FRLS multistranded copper conductor as earth wire including taking down old submain wiring complete all as directed. Note:- 2 runs of 1.5 sqmm cable and one run of 1.5 sqmm cable and one run of PVC conduit and accessories will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with 2 single core 2.5 Sqmm PVC insulated FRLS multistranded copper conductor and drawn through surface PVC conduit and its accessories including one run of PVC insulated 2.5 Sqmm FRLS multistranded copper conductor as earth wire including taking down old submain wiring complete all as directed. Note:- 2 runs of 2.5 sqmm cable and one run of 2.5 sqmm cable and one run of PVC conduit and accessories will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with 2 single core 4 Sqmm PVC insulated FRLS multistranded copper conductor and drawn through surface PVC conduit and its accessories including one run of PVC insulated 4.0 Sqmm FRLS multistranded copper conductor as earth wire including taking down old submain wiring complete all as directed. Note:- 2 runs of 4 sqmm cable and one run of 4 sqmm cable and one run of PVC conduit and accessories will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with 2 single core 6 Sqmm PVC insulated FRLS multistranded copper conductor and drawn through surface PVC conduit and its accessories including one run of PVC insulated 6.0 Sqmm FRLS multistranded copper conductor as earth wire including taking down old submain wiring complete all as directed. Note:- 2 runs of 6 sqmm cable and one run of 6 sqmm cable and one run of PVC conduit and accessories will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with 4 single core 4 Sqmm PVC insulated FRLS multistranded copper conductor and drawn through surface PVC conduit and its accessories including one run of PVC insulated 4.0 Sqmm FRLS multistranded copper conductor as earth wire including taking down old submain wiring complete all as directed. Note:- 4 runs of 4 sqmm cable and one run of 4 sqmm cable and one run of PVC conduit and accessories will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with 4 single core 6 Sqmm PVC insulated FRLS multistranded copper conductor and drawn through surface PVC conduit and its accessories including one run of PVC insulated 6.0 Sqmm FRLS multistranded copper conductor as earth wire including taking down old submain wiring complete all as directed. Note:- 4 runs of 6 sqmm cable and one run of 6 sqmm cable and one run of PVC conduit and accessories will be measured as one unit
Taking down carefully aluminium point wiring (light, fan, socket or power), complete and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked drawn through in and including heavy duty, PVC Conduit/ casing caping including all accessories etc, with modular sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment, covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
(a) One light/fan point controlled by one, one way switch
(b) One light point controlled by two, two way switch
(c) One bell point controlled by one, bell switch
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 40 above but with multistranded copper conductor 2.5 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, on independent, including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked in PVC rigid conduits heavy duty ISI marked totally concealed in wall/floor/roof including all accessories etc, with modular sunken boxes with modular white cover plate with frame suitable for modular switches/ sockets and PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
(a) One light/fan point controlled by one, one way switch
(b) One light point controlled by two, two way switch
(c) One bell point controlled by one, bell switch
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 42 above but with multistranded copper conductor 2.5 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, on independent, including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly.
S&F MCB TP rated capacity 63 Amps, 415 Volts breaking capacity 10 KA 'B' curve complete all as directed.
S&F MCB TPN rated capacity upto 40 Amps, 415 Volts breaking capacity 10 KA 'B' series complete all as specified.
S&F MCB SPN rated capacity 32 Amps, 240 Volts breaking capacity 10 KA 'B' series complete all as directed.
S&F MCB SP rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA 'B' Curve complete all as directed.
S&F in replacement MCCB TP/TPN 415 Volts 16 KA of capacity 63 to 100 Amps with extended spreaded terminals complete all as directed.
Taking down the existing unserviceable main switch / DBs of any type / capacity / description as existing at site and making good the disturbed surfaces to match with the existing finishes all as specified.
S&F sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 Volts suitable for fixing double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the distrubed surface to match with existing colour of wall complete all as directed.
S&F vertical type double door TPN DB 6 way IP 43 recess mounted/ wall mounted type with incoming MCCB 3 Pole, 25 KA, 100Amps and outgoing MCB SP 32 Amps suitable for single phase/three phase out going including including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the distrubed surface to match with existing colour of wall complete all as directed
S&F sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the distrubed surface to match with existing colour of wall complete all as directed.
All as per item No 52 above but MCB DB 8 way
All as per item No 52 above but MCB DB 6 way
All as per item No 52 above but MCB DB 4 way
S&F sheet metal enclosures single pole and neutral enclosure with a three pin and earth plug and socket complete with one MCB SP 20/ 32 Amps including dismantling of old unserviceable one complete all as directed.
M&L for Servicing / testing of Metering indoor building Panels, 03/01 Phase, 415/230 Volts all as specified and as directed. (i) Repair/ replacement of damaged hinges and locks/latches of each compartment. (ii) Cleaning of existing bus bars with CTC applying with red solution, providing bus bar insulation and re fixing with new nuts, bolts, washers etc. (iii) Replacement of damaged copper cable and fixing new copper cable for incoming and outgoing connections of each MCCB/MCBs switches alongwith lugs terminals to bus bars including connector. (iv) Replacement of damaged cable protection pipe and damaged/ wornout cable insulation and lugs of any size for incoming & outgoing cables (v) Replacement of neoprene gasket and transparent acrylic sheet 3 mm for all doors of panel board. (vi) Repainting of panels after removing the rusting, scrapping, cleaning and drying the surfaces complete. (vii) Running welding wherever required Note : Replacement of unserviceable MCCB/MCBs MCCB/MCB shall be measured & Paid separately
M&L in replacement for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including necessary excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn through in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete Notes for item No 1 to 59 :- (a) The contractor shall detail electrician with helper for attending door to door domestic electric complaints at various locations in defence area including checking serviceability of electric items as required at site and as directed. (b) Contractor will deploy electrician with helper to attend complaint in AFMC Offrs/JCOs/OR Md accn as well as in servant qtrs alongwith necessary tools, safety equipments and transportation required to attend complaint. (b) Complaint will be attended within 24 hours. (c) Electrician & Helper employed by contractor shall Possesses security pass all the time whenever on work shall be responsibility of contractor. (d) Subsequently sufficient store as required for execution of items as per BOQ shall be procured by the contractor for day to day complaints.
Suchit constructions
Sparkh Electricals & Works
M/s Asrani and sons
A K ENTERPRISES
KSP ENTERPRISES
Baljeet Singh Choudhari
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .