Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹40.8 L+₹2.8 L (7.50%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹41.1 L+₹3.1 L (8.12%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹45.0 L+₹7.0 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹45.7 L+₹7.7 L (20.3%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | L.K.R.TIWARI CONSTRUCTION | L.K.R.TIWARI CONSTRUCTION L2 | UNIQUE ENGINEERS L5 | M/S JAYCONSTRUCTION CO L6 | DARSHAN ENTERPRISES L4 | ShreHari Civil Enginneering and Contractors L7 | Mukund Engineers and Contractors L8 | K.D.Electricals L1 | RK ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTE FOR PLUMBING AND SANITARY ITEMS:- (i) Contractor shall deposit entire quantity of plumbing and sanitary wares materials required / covered under subject contract in the custody of Engineer-In-Charge/ Office in charge of unit. (ii) The materials as required shall be issued to contractor by JE/ Engineer-In-Charge on daily basis. (iii) Register shall be maintained for receipt and issue of materials with respective PVS of materials duly signed by Engr-in-Charge and shall be produced to GE during running payments. | ||||||||||||
| 2.00 | Demolition and breaking up drain pipes ( salt glazed sanitary ware AC/RCC) of dia 200mm drain pipes set in cement mortar, dia of pipe 200mm. | 300 | RM | 30 ₹9,000 | 30 ₹9,000 | 35 ₹10,500 | 20 ₹6,000 | 100 ₹30,000 | 50 ₹15,000 | 25 ₹7,500 | 9 ₹2,700 Lowest | 15 ₹4,500 |
| 3.00 | Description all as per item No. 2 above but dia of pipe 150mm. | 110 | RM | 30 ₹3,300 | 30 ₹3,300 | 35 ₹3,850 | 20 ₹2,200 | 50 ₹5,500 | 75 ₹8,250 | 20 ₹2,200 | 9 ₹990 Lowest | 15 ₹1,650 |
| 4.00 | Description all as per item No. 2 above but dia of pipe 300mm. | 120 | RM | 40 ₹4,800 | 40 ₹4,800 | 45 ₹5,400 | 20 ₹2,400 | 150 ₹18,000 | 100 ₹12,000 | 34 ₹4,080 | 12 ₹1,440 Lowest | 20 ₹2,400 |
| 5.00 | Cleaning of existing septic tank of any capacity by using Mechanical Pumping Machine to remove water, sludge, stones, solid particles etc complete from the septic tank at any location and at any distance from road and removing the same from the campus complete all as specified and as directed.
(i) Necessary precautions as well as safety measures shall be taken by the contractor without any extra cost, for working in foul conditions.
(ii) The contractor shall be entirely responsible for the lapse, mishappening to any of the manpower deployed and/or to other equipment/machinary/material at the site of work during the execution.
(iii) Contractor have to provide tractor mounted jet spray machine to flush settled sludge in the inlet pipe.
(iv) At some location contractor have to provide electric pump alongwith flexible pipe connection to inlet and outlet of pump, for dispose of sludge sewage water | 60 | Cum | 390 ₹23,400 | 390 ₹23,400 | 510 ₹30,600 | 400 ₹24,000 | 400 ₹24,000 | 500 ₹30,000 | 2,050 ₹1,23,000 | 1,000 ₹60,000 | 350 ₹21,000 Lowest |
| 6.00 | Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or for manholes, pipes etc and getting out in soft soil complete all as specified and as directed. | 250 | Cum | 320 ₹80,000 | 320 ₹80,000 | 410 ₹1,02,500 | 300 ₹75,000 | 300 ₹75,000 | 300 ₹75,000 | 250 ₹62,500 | 150 ₹37,500 Lowest | 150 ₹37,500 Lowest |
| 7.00 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided below or above GL complete all as specified and as directed. | 210 | Cum | 400 ₹84,000 | 400 ₹84,000 | 610 ₹1,28,100 | 500 ₹1,05,000 | 1,000 ₹2,10,000 | 250 ₹52,500 | 790 ₹1,65,900 | 100 ₹21,000 Lowest | 100 ₹21,000 Lowest |
| 8.00 | Demolition of precast concrete block walling built in cement mortar as in manhole including PCC coping. | 80 | Cum | 400 ₹32,000 | 400 ₹32,000 | 610 ₹48,800 | 500 ₹40,000 | 800 ₹64,000 | 500 ₹40,000 | 520 ₹41,600 | 100 ₹8,000 Lowest | 200 ₹16,000 |
| 9.00 | Demolition of reinforced cement concrete manhole covers/septic tank covers n. exc. 15cm thick complete all as specified and as directed. | 5 | Cum | 1,400 ₹7,000 | 1,400 ₹7,000 | 1,610 ₹8,050 | 500 ₹2,500 | 700 ₹3,500 | 1,000 ₹5,000 | 1,150 ₹5,750 | 100 ₹500 Lowest | 400 ₹2,000 |
| 10.00 | Taking down cement plaster from brick or block masonry walls including raking out joints, hacking for key, scrubbing down with water etc. | 400 | Sqm | 30 ₹12,000 | 30 ₹12,000 | 50 ₹20,000 | 30 ₹12,000 | 100 ₹40,000 | 25 ₹10,000 Lowest | 43 ₹17,200 | 25 ₹10,000 Lowest | 25 ₹10,000 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Feb 2026, 6:00 pmClosed
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE
REPAIR/MAINT AND CLEANING OF SEWAGE LINES, MANHOLES SEPTIC TANK AND REPAIR/MAINT PATHWAY, DRAIN AND ALLIED B/R WORKS AT TRG BN-I, BIRAJDAR, SPORTS COY AND HRDC IN BEG AND CENTRE UNDER AGE B/R-II IN GE (C) KHADKI.
2026_MES_750728_1
8339/E8 OF 2025-2026
Open Tender
Civil Works
Item Rate
270 days
BEG AND CENTRE area
Class D Category a(ii)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KHADKI
₹90,000
Yes
27 May 2026
31 Jan 2026
24 Feb 2026
31 Jan 2026
21 Feb 2026
14 Feb 2026
31 Jan 2026 - 7 Feb 2026
NOTE FOR PLUMBING AND SANITARY ITEMS:- (i) Contractor shall deposit entire quantity of plumbing and sanitary wares materials required / covered under subject contract in the custody of Engineer-In-Charge/ Office in charge of unit. (ii) The materials as required shall be issued to contractor by JE/ Engineer-In-Charge on daily basis. (iii) Register shall be maintained for receipt and issue of materials with respective PVS of materials duly signed by Engr-in-Charge and shall be produced to GE during running payments.
Demolition and breaking up drain pipes ( salt glazed sanitary ware AC/RCC) of dia 200mm drain pipes set in cement mortar, dia of pipe 200mm.
Description all as per item No. 2 above but dia of pipe 150mm.
Description all as per item No. 2 above but dia of pipe 300mm.
Cleaning of existing septic tank of any capacity by using Mechanical Pumping Machine to remove water, sludge, stones, solid particles etc complete from the septic tank at any location and at any distance from road and removing the same from the campus complete all as specified and as directed. (i) Necessary precautions as well as safety measures shall be taken by the contractor without any extra cost, for working in foul conditions. (ii) The contractor shall be entirely responsible for the lapse, mishappening to any of the manpower deployed and/or to other equipment/machinary/material at the site of work during the execution. (iii) Contractor have to provide tractor mounted jet spray machine to flush settled sludge in the inlet pipe. (iv) At some location contractor have to provide electric pump alongwith flexible pipe connection to inlet and outlet of pump, for dispose of sludge sewage water
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or for manholes, pipes etc and getting out in soft soil complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided below or above GL complete all as specified and as directed.
Demolition of precast concrete block walling built in cement mortar as in manhole including PCC coping.
Demolition of reinforced cement concrete manhole covers/septic tank covers n. exc. 15cm thick complete all as specified and as directed.
Taking down cement plaster from brick or block masonry walls including raking out joints, hacking for key, scrubbing down with water etc.
Material and labour for cement concrete 1:3:6 type C-2, as in concrete bed to drain pipes including packing under & haunching against sides of pipes after they are laid and tested for 300 mm complete all as specified and as directed.
Description all as per item No. 12 above but for drain pipes of 150 mm bore
Description all as per item No. 12 above but for drain pipes of 200 mm bore
Material and labour cement concrete 1:4:8 type D - 2 in foundations filling & mass concrete complete all as specified and as directed.
Material and labour for reinforced concrete pipes, 300 mm bore, Class NP-2, laid and jointed complete with collars all as specified and as directed..
Material and labour for reinforced concrete pipes, 150 mm bore, Class NP-2, laid and jointed complete with collars all as specified and as directed..
Material and labour for reinforced concrete pipes, 200 mm bore, Class NP-2, laid and jointed complete with collars all as specified and as directed..
Material and labour for precast cement concrete block massonry with solid blocks exceeding 10 cms in width built in cement mortar 1:6 precast cement concrete (1:3:6) type C1 using 20mm graded stone aggregate conforming IS 2185 PART 2:1983 complete all as specified and as directed by Eng-in-charge.
Description all as per Item No 19 above except blocks
Material and labour for PCC 1:2:4 Type B-1 using 20 mm graded coarse aggregate as in coping including necessary formwork and benching in bottom of manholes drain etc complete all as specified and as directed..
Material and labour rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surfaces even and smooth without using extra cement including 3% WPC complete all as specified and as directed (WPT shall be measured separately).
Supplying only integral water proofing compound complete all as specified and as directed. MAKE :- Dr FIXIT/UltraTech Cement or techno commercially equivalent
Returning, filling in soft soil spreading, levelling, watering and well ramming in layers n. exc. 25 cm complete all as specified and as directed.
Removing excavated soil n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed.
Material and labour for precast cement concrete 1:2:4 type B-1 (using 20 mm graded coarse aggregate) in cover slab set in CM 1:6 complete all as specified and as directed.
Material and labour for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bend to shape required, including cranking, bending and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Material and labour two safaiwala & two helper (Total Four people) alongwith T & P with one supervisor for record complaint received from AGE B/R-II complaint cell and in holidays/sunday's receive complaint in respect of any telecommunication or directly through office from 0830 hrs to 1700hr on all working days (except sunday and holidays) for cleaning of all blockage of sewerage of any type sewerage line, branch line main sewer line, etc of any section and that any situation by way of cleaning/desludging by using mechanically or pumping out sewage from block manholes where required and directed by Engineer-in-charge and keeping sewer line functional. Day-to-day complaints of chocked up manholes, sewage lines etc. Cleaning the trap WC, soil waste, vent pipe, gully traps, upto final drop outlet, inlet of septic tank working in foul condition with taking precautionary measures, equipments and required power/cable Pertaining to OTM and MD Accn of Trg Bn-I. NOTE :- (i)Complaints of blockages and cleaning of sewage line are to be received daily from the complaint cell situated in the premises of office of the AGE B/R-II (C) Kirkee and entire complaints are to be attended for cleaning on the same day. Contd to 27.01
Contd from...,,27.00 (ii)Rate included for supply of for experienced safaiwala & one supervisor and required tools and plants. (iii) The payment towards the subject items shall only be made as per the total number of days, contractor had cleaned and cleared the blockages of sewage line. (ii) In case urgent nature of complaints, contractor has to attend the complaints even on Sundays and holidays also & records of complaints attented on sundays and holiday be maintained and produced to GE during running payment Register be maintained with date and time of complaint lodged by user of complaint slip number issued by department and completion of complain duly signed by user. (iii) Contractor shall maintain a register including details of day of cleaning of sewage line, duly signed by contractor and Engineer-in-Charge. If the contractor will not be able to provide the man power, the recovery of Rs. 600/- per person per day will be deducted and in addition that day will also not be counted for payment
Dismantling of precast interlocking tiles/ paver blocks, chequered tiles of any description thickness & size complete all as specified and as directed.
Material and labour for 25 mm thick sand filling under floors or foundations including watering and consolidation complete all as specified and as directed.
Material and labour for 75 mm thick PCC 1:3:6 type C1 and as in Plinth protection to prevent moisture from entering in building through its base complete all as specified and as directed.
Material and labour for 75 mm thick, PCC (1:4:8) type B-2 using 40 mm graded stone aggregates as in sub base complete all as specified and as directed.
Material and labour for providing 60 mm thick machine pressed precast concrete interlocking paver blocks of any shape and size conforming to IS-15658-2006,with grey cement and pigment,rubber moulded tiles M-35 Grade,as in floors,paving,path etc.complete all as specified and as directed. MAKE:- ULTRA/vaishnavi and techno commercially equivalent.
Supply and fix for providing precast cement concrete louvres and jallies, 35 mm thick (measured solid), including all mouldings using cement concrete type B0 1:2:4 (12.50 mm graded aggregate) set in cement mortar 1:4 including taking down old jallies etc complete all as specified and as directed.
Material and labour 100mm thick PCC type B2 (1:2:4) 40 mm graded stone agg in floor finished fair, even and smooth without using extra cement.as in hardstanding complete all as specified and as directed.
Material and labour for removing the leaking outlet bends and fitting joints of 100 and 75mm and repairing leaking joints by PVC solvent or ordinary cement and closing the gap in outlet by cement sand mortar for making leakage free duct walls followed by Removal of weeds and vegetation on outlet side with hand tools only and injecting Monsanto’s herbicide to prevent the growth of new plants in future, finishing,including replacements of damaged bends and fitting joint complete all as specified and as directed by Eng-in-charge.
Material and labour for preparing new plastered and applying two coat of cement based paint (any tint) over a coat of primer on walls complete all as specified and as directed.
Material and labour for preparation of old plasterd or unplastered surfaces of wall and applying one coat cement base paint making good complete all as specified and as directed.
Supply and fix rotational moulded polyethylene water storage tanks three layer having capacity 500 litres ( cylindrical vertical with closed top ) hoisted and fixed in position including dismantling and removing of old tank complete all as specified and as directed. Note:-ISI mark should be embossed on tank complete all as specified and as directed.
Supply and fix rotational moulded polyethylene water storage tanks three layer having capacity 1000 litres ( cylindrical vertical with closed top ) hoisted and fixed in position including dismantling and removing of old tank complete all as specified and as directed. NOTE :- ISI mark should be embossed on tank.
Supply and fix rotational moulded polyethylene water storage tanks three layer having capacity 2000 litres ( cylindrical vertical with closed top ) hoisted and fixed in position including dismantling and removing of old tank complete all as specified and as directed. NOTE :- ISI mark should be embossed on tank
Supply and fixed in repair provision of Ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20 mm dia of the pipe complete all as specified and as directed.
Supply and fixed in repair provision of Ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 15 mm dia of the pipe complete all as specified and as directed.
Supply and fixed in repair provision of Ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 25 mm dia of the pipe complete all as specified and as directed.
Disconnecting existing tanks upto 500 litre capacity,including removal of settled sludge,setting aside (or lowering if required) for repairs,cleaning ,by chemical cleaning etc and hoisting if required,reconnecting and refixing in position as in same position complete all as specified and as directed. including refixing/repair of covers & float valve.
Disconnecting existing tanks 500 to 1000 litre capacity,including removal of settled sludge,setting aside (or lowering if required) for repairs,cleaning ,by chemical cleaning etc and hoisting if required,reconnecting and refixing in position as in same position complete all as specified and as directed. including refixing/repair of covers & float valve.
Disconnecting existing tanks upto 2000 litre capacity,including removal of settled sludge,setting aside (or lowering if required) for repairs,cleaning ,by chemical cleaning etc and hoisting if required,reconnecting and refixing in position as in same position complete all as specified and as directed.including refixing/repair of covers & float valve.
Supply and fix in repair 75mm bore PVC(SWR) pipe, type 'B' single socketed in any length with rubber ring joints laid in trenches or floors fixed in repairs all as specified and as directed.
Supply and fix in repair 110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
Supply and fix in repair PVC (SWR) bends type 'B' of any radius, 75 mm dia complete all as specified and directed.
Supply and fix in repair PVC (SWR) bends type 'B' of any radius, 110 mm dia complete all as specified and directed.
Supply and fix in repair 75 mm bore PVC (SWR) branch piece (single Y), type 'B' equal or unequal with access door complete all as specified and as directed.
Supply and fix in repair 110 mm bore PVC (SWR) branch piece (single Y), type 'B' equal or unequal with access door complete all as specified and as directed.
Supply and fix in repair 110mm bore PVC (SWR) WC connector type 'B' any type fixed in repairs complete all as specified and as directed.
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and Material and labour for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. (Make: PIDILITE or equivalent) complete all as specified and directed and Material and labour for fixing packer for hydrophobic PU foam and Sealer as per manufacturers specification.
Material and labour for the tile joint chemical cleaning and re-grouting carefully by washing the existing tile with heavy duty tile cleaner preferably of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, curing, cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
Repairs to existing steel gates, including taking down from original position and repair to damaged/disturbed portion of gate including replacement of tower bolt,sliding bolt and necessary repair at required places of gatettc including painting to disturbed surface complete all as specified and as directed.
Material and labour for PVC (SWR) gully trap 125/110mm setting and jointing in solvent cement complete all as specified and as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.12 MB
BOQ_840819.xls
BOQ • 0.34 MB
8339Tender.pdf
Tender Documents • 5.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .