Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC NO 50 III CROSS STREET VELNURUGAN NAGAR KOSAPALAYAM PUDUCHERRY 605 013 | PONDICHERRY | PUDUCHERRY | 605013 | ₹29.5 L | L1 | Accepted-AOC Lowest Tenderer |
| 2 | L2₹31.6 LRejected-Finance | ₹31.6 L | L2 | Rejected-Finance Not Quoted lowest amount |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not fullfilled Eligibility Condition |
Tender Value
₹31.7 L
EMD Value
₹63,443
Closing Date
20 Jan 2021, 4:00 pmClosed
Chief Executive Officer
PSCDL, No.2, Bussy Street, Old Court Building, Puducherry
Installation testing and commissioning of image Projection LED lights in Southern Promenade Beach road Puducherry
2021_PSCDL_7511_1
33/PSCDL/2020-21
Open Tender
Electrical Works
60 days
Puducherry
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹63,443
23 Feb 2021
12 Jan 2021
21 Jan 2021
12 Jan 2021
20 Jan 2021
12 Jan 2021
Amount
Supply , Installation, testing and commissioning of waterproof projector allowing both image projection and creative light framing. It should be possible to adjust the output precisely to match the surroundings or to create a particular effect: literally 'light sculpting'. High quality output should include advanced control of light distribution and significantly reduced glare. The beam angle and image size should easily be altered on site from 20° to 40°. It should also be possible to adjust the ' focus, uniformity and intensity of the projected light.System should be with Built- in xitanium LED Driver.System light flux should have Lighting Output Ratio (LOR): up to 67%, up to 3750 1m system flux (5590 Im source flux). System features should include Four non-reflecting lenses: beam angle adjustments of 2 x 10° to 2 x 20° (ZoomSpot),Image size (0): adjustable by moving the lens along the optical axis. lmage focus: adjustable by moving the two lenses along the optical axis. Image uniformity: adjustable by moving the diaphragm (0 50 mm} along the optical axis. System power consumption should be 55W with tolerance +/-10%. Operating temperature range should be -20C to +35C. Luminaire should have ingress protection of IP66 and impact resistance of IK06. Housing of the luminaire should be Aluminum casting, ultra-dark grey RAL 10714 painted, marine salt protected 500 hrs. Universal bracket should be of galvanized steel laser cutting. Front Cover should be of air tempered flat glass, thermally hardened, 4 mm thick optical lenses set: clear glass with an anti-reflection coating. The above fixture shall be mounted on a decorative GI p with a height of 6m with PU quoted paint and the pole should match the RAL shade of the luminaire. Each Pole shall have two nos of above mentioned projector tor achieving the desired output – Cat Ref: Philips PROLED.
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Double Pole
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Single Pole
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Triple pole and neutral
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal / coke and salt) as required
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -4 x 2.5 sq.mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 25mm
Providing and fixing Aluminium UG cable (4c x 10 sq.mm) as directed by the Engineer-in-charge
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
Supply and Fixing of junction box of size 850mm x 350 Mm x 250mm with terminals for connecting the cables . The box to be grouted to the ground with MS angles / GI pipe and concreting at above the ground as directed by the Engineer — in — charge . (Make : Sintex) . Note : Job also includes fixing/assembling of necessary control components and timer control components inside the box for fittings control as required for site condition / requirement
Providing and fixing Timer switch (daily)/ digital time switches daily programme with standby battery (3years) 1channel . Make:L&T-Hagger/Legrand-Lexic as directed by the Engineer-in-charge.
Providing and fixing 40A power contactors Make: Siemens / L&T as directed by the Engineer-in-charge.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X10 sq.mm (25 mm)
Providing , laying and fixing following dia G.I.pipe (medium class) in ground complete with G.I.fittings including trenching (75 cm deep) and re-filling etc as required- 80mm dia
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electode , including connection / termination with GI thimble etc. as required
Providing and laying in position with 1:1.5:3 reinforced cement concrete work in foundation including earth work excavation of size 0.75x0.75x0.75 m M-sand filling of 0.75x0.75x0.10 m, PCC 1:4:8 of 0.75x0.75x0.15 m & RCC mat of 0.75x0.75x0.2 m with pedestal of 0.45x0.45x1.05 m including centering shutting, reinforcement, refilling the trenches and plastering the exposed pedestral surface with cement mortar 1:3-6mm thick all etc., complete for making High Mast base concret as directed by the Engineering in Charge.
Kumar Electricals Service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid