Electrical work in c/w Augmentation of Service building for SSE(C&W) office in lieu of old building for C&W Coaching Depot, FZR, Electrical work in c/w General Watering Arrangements at FKA, MOGA & LNK of Firozpur Division, Electrical work in c/w Provision of 15 bedded male barrack at Attari and Electrical work in c/w Improvement to washing line no. 4 and Sick line / Ac pit at Amritsar Railway Station in the section of ADEN-I/ASR.
251-Elect-T-02-2026-27
251-Elect-T-02-2026-27
Open
6 Months
Firozepur, Punjab
₹0
₹1.5 L
12 Jun 2026
12 Jun 2026
19 Jun 2026
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar. Metal boxes boards are to be concealed in the wall for 12 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 8 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 4 Module
4 FEROZPUR DIVISION-ELECTRICAL/NORTHERN RLY 4 Description:- Supply and Erection of modular metal boxes concealed boards with white finish single mounting plate and fixing of switches/plug socket and connection wiring. Make Legrand (Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 3 Module
tech. specification IS/IE rules and site requirement.
tech. specification IS/IE rules and site requirment.
per tech. specification IS/IE rules and site requirment.
as per tech. specification IS/IE rules and site requirement.
Description:- Supplying, laying, testing and commissioning of FRLS 1.0 sq mm PVC insulated
marked, make Finolex, Havells, Polycab, KEI in the recessed PVC conduit pipe 25 mm dia as required at site.
copper conductor cable 1100 Volt 1.5 Sq.mm multi stranded confirming to IS-694 latest, ISI marked in the existing PVC pipe.
Description:- Supply, laying, fixing, testing and commissioning of 2.5sq mm FRLS, PVC insulated
marked, make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IE rules.
Description:- Supply, laying, fixing,testing and commissioning of 4 sq mm FRLS, PVC insulated
marked, make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IE rules.
9537/Pt.III/1983 or Latest Version, ISI marked with accessories, junction box, etc including making chase, plastering/clamping etc as per technical specifications.
Description:- "Supply, fixing, testing and commissioning of LED light luminaries, having system
all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be of make Phillips, Bajaj,Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3'), & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') or latest"
Description:- Supply, fixing, installation, testing and commissioning of energy efficient 230V,50 Hz
speed-120 to 260 V AC with 5 step speed control electronic regulator, copper winding complete as per IS : 374-1979 or latest IE rule & site requirement. Make Bajaj, Usha, Havells, Crompton, Orient or equivalent.
existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement.
propeller type exhaust fan complete as per IS, IE rule & site requirement. Make Usha, Orient, Bajaj or equivalent
Description:- Supply, erection, testing and commissioning of the following Double door wall
comprising; (i) Incoming MCB 40 A DP 10 KA B/C - 1 No. (ii) Outgoing MCB 16 A. SP 10 KA B/C - 6 Nos. FEROZPUR DIVISION-ELECTRICAL/NORTHERN RLY
volts, 40 Amp RCCB having a sensitivity 30ma in the existing MCB DB complete with connections, testing and commissioning etc. as required., 40 amps.
Description:- Supply, erection, testing and commissioning of the following Double door wall
comprising; (i) Incoming MCCB 4Pole 63 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (4 Nos. On each Phase) - 12 Nos.
isolator, datalogger, transformer online UPS system with SMF/VRLA type battery for an autonomy of
Description:- Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured,
cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Above 25 sq.mm
Description:- Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured,
cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of upto 25 sq.mm
Description:- Design, manufacturing of floor mounted MS feeder post made of MS sheet 16 SWG
having cable glands 2 Nos. duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals.
Description:- Earthing arrangement by providing earth electrode of GI pipe 50 mm dia (B class) 4.5 meter long with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch
Tech specification at annexure 'A' relevant ISS & IE rules and site requirements. A suitable CI/MS/RCC cover as approved by Rly . Representative, cover with locking arrangement shall be provided.
mentioned in explanatory note.
Description:- Supply, installation, testing and commissioning of 150 Watt LED based flood light
arrangement, accessories & flexible copper wire for connetion as per ISS/IR rules & as per CEE/NR Specification No. CEE/NR/121-Elect/PS/2018 (Rev.03) dated 28.06.2018 & CEE/NR/121-Elect/PS /2019 (Rev.4) dated 04.11.2019 respectively or latest
Description:- Supply & testing : Submersible pump set ISI marked 500 LPM, 90 Mtr head with
HP suitable for operation on 415 Volt +/- 5%, 3 phase, 50Hz conforming to IS 8034-2002 or latest and also having impller & bush of Brass on metal alloy as per attached technical specification. Make- KSB, Amrut & Sabur or similar. Make.
system for safety and checking dropping down of submersible pump upto non return valve and connection with sluice valve to be matched with delivery pipe at ground level.
31 FEROZPUR DIVISION-ELECTRICAL/NORTHERN RLY Description:- Supply,fixing,testing and Commossioning of 20 HP fully automatic star-delta starter for submersible pump with overload current range 20-32amp, with single phase protection, Dry run, over voltage , under voltage and phase reversal with all accessories and as per site requirement..
Valve 3 inch dia and CI bends complete with connection etc. of make Standard, BEER, or similar conforming to latest version of relevant IS CODE.
laying method including supply and jointing of HDPE pipe.
Description:- Supply and erection of minimum 45 W LED Street light fitting operating voltage single phase 230 volts AC, 50Hz complete with all accessories as per CEE/NR Specification.
dated 04.11.2019 or latest respectively including connection with 2x2.5 sq.mm PVC insulated multi stranded FRLS copper conductor cable, testing, commissioning & earthing required and as per explanatory note.
Description:- Supply and fixing of bracket on pillar or as required made out of GI pipe 1 M 40mm
double clamp made of 40x5 mm GI clamp & suiatable GI nut bolt & washer & as per explanatory note
Desert Cooler having: •Powerful Air Flow:1750 Cubic Meter/Hr(Peak) 1200 Cubic Meter/Hr (Average) • Auto Water Level Controller •Humidity Control Valve •Water Tank Capacity: 32 Litres
energy efficient compressor cooling capacity LTR/HR150, storage type,confirming to IS-1475-1PART 1, of 2001 or latest make blue star, voltas or similar.
element, CFC free high density PUF insulation, inner tank extreme hard water resistance, suitable for high rise building & pressure pump, suitable for 230V 50Hz AC supply.
power unit complete with modular plate, MCB, starter, plug &socket for AC of make Wipro North West (Model -ACPU6MBT/ ACPU6M-FT) or equivalent as per IS & IE rules.
Description:- Design, manufacturing, supply erection testing &commissioning of outdoor type feeder piller type panel LT distribution system suitable for 3phase 4 wire 415 V AC supply comprising
MCCB 4P 63 A with 35 KAB/C -2 Nos iii)Out going MCCB 32A 4P with 5KAB/C-6Nos. The feeder pillar shall be complete with copper bus bars 150Amps. for phases and 75Ampsfor neutral as per drawing approved by railways and explanatory Notes.
Description:- Supply, Erection, Fixing, Testing and commissing of LT panel having incoming 1x250
4x32 Amp 35 KA FP MCCB with Amp meter, volt meter and indicator. Make of MCCB &MCB M/s Legrand, Havells, Schenider
Description:- Design, manufacturing, supply, erection & commissioning of weather proof, floor mounted, dust & vermin proof as per IS:8623/1993 Pt-I to Pt-III (Latest version) as per Drg No.CEE/NR/Elect/AC/311 outdoor type 415 Volt pre-cooling cum battery charging box as per
bus bar for phases & 160 A for neutral MCCB 100 Amp TPN = 1 No., 415 Volt, 63 A, 5 pin socket for operation on 3 phase 415 Volt AC system b) Battery charging point portion of the box complete with Aluminium bus bar 200 Amp, DP MCB 32 A DC = 1 No., 110 Volt 32 A 3 pin socket = 1 No. for operation on 110 DC system.
Description:- Design Supply, fixing and commissioning of the LED based pit light fitting 18 watt,input voltage 48 V AC as per PCEE Spec. CEE/NR/121 Elect/PS/2018(Rev-03) dt 28/06/18 & CEE/NR/121-Elect/PS/2019(Rev-04) dt 04.11.2019 with correction dt.10.02.2020 or latest , Size of light fitting & fixture should be approved by railway before installation and fixing & grouting work
FEROZPUR DIVISION-ELECTRICAL/NORTHERN RLY
Description:- Supply, fixing and commissioning of the bulkhead LED based aluminium die cast with power coating grill fitted below cat walk light fitting 22 watt,input voltage 48 V AC as per PCEE Spec.
with correction dt.10.02.2020 or latest , Size of light fitting & fixture should be approved by railway before installation and fixing & grouting work should be done as per site requirement..Gaurantee-05 years from date of commissioning.
Description:- Design Supply, installation ,testing and commissioning of step down Transformer outdoor 20 KVA with control panel Specifications for transformer Input voltage Range 440 V AC, Output Voltage- 48V AC +/- 5% V,Minimum 4 output terminals, Type cooling-oil cooled, Control card
notching core material, display -Digital ,Temp rise 45° C above ambient, Frequency 50 Hz ,Protections Low/High voltage , Control panel- size & capacity of control panel should be as per transformer capacity 20 kva & connected load at transformer.Control panel should have 3 phase incoming & required capacity outgoing feeders, Transformer & control panel should be approved by railway before installation as per site requirement.
Description:- Fabrication, supply, erection, testing and commissioning of welding points suitable for 400 Volt AC supply system in the enclosure made of MS sheet 16 SWG die pressed with powder
XLPE armoured cable aluminium bus bar of 400 Amps rating, 2 Nos. porcelain shackle insulator fitted on backelite sheet 325x40x12 mm thick interconnection with suitable capacity cable and suitable arrangement for taping connection for welding cables terminals etc. and provision of holes in the busbar for looping 2 Nos. 185 sq.mm 2 core cable as required at site including earthing.
conforming to IS9537 part- III / 1983 (latest version) with accessories, junction box, bend including making chase, plastering / clamping as approved by railway and as per explanatory notes
including finolex sheet at concrete wall.
Description:- SUPPLY, INSTALLATION,TESTING AND COMMISSIONING, OF DISTILLED WATER PLANT
STEELBODY,230 VOLTS 50 HZ,SINGLE PHASE,PH VALUE:6.9-7.5, TDS 0-5 PPM ,DUTY CYCLE 125 LTR/DAY,WATER PRESSURE 1.5 KG/SQCM WITH 02 NOS FILTER CARTRIGGE ,ELECTRICAL RESISTIVITY MIN 1M OHM-CM.CARBON CONDUCTIVITY MAX 1us/cm .
made out of 2 mm thick CRCA sheet of size 300x100x100 mm with cover 2 mm thick.
mm 24inches make Bajaj, Khaitan, Crompton 230 Volt, 50 Hz AC supply.
confirming to relevant IS : (Latest Version) suitable for operation on 415 Volt 3 phase 4 wire AC supply system with 125 volts to 150 volts DC output, 200 Amps, capacity.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS11.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
LEDSpecification.pdf
ATTACHMENT
LEDSpec.1.pdf
ATTACHMENT
LEDSpec2.pdf
ATTACHMENT
GCCCorrectionSlip.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS2_1.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
RewirngSpec-I.pdf
ATTACHMENT
ACS7.pdf
ATTACHMENT
ACS8.pdf
ATTACHMENT
ACS9.pdf
ATTACHMENT
ACS10.pdf
ATTACHMENT
GCCClarificationRegarding.pdf
ATTACHMENT
Tenderdocumentfinal.pdf
ATTACHMENT
RDSOSpecUPS.pdf
ATTACHMENT
Download all tender documents and submit your bid