Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 150 VILLARASAMPATINALL ROAD PO NASIYANUR ROAD ERODE 638107 | ERODE | ERODE | TAMIL NADU | 638107 | Admitted-Finance |
| 2 | Admitted-Finance 56 ARUNACHALAM MAIN ROAD AMBAL NAGAR PORUR CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
1 Jun 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer/Hydro
5th floor,Eastern Wing,NPKRR Maaligai,Annasalai, Chennai-2
E-Tender for Rectification and replacement including reinsulation of defective stator coils in Y phase including supervision, erection, testing and commissioning of 100 MW Unit III Generator at Kadamparai Power House.
2023_EB_318870_1
HE-2461
Open Tender
Electrical Works
Item Rate
45 days
Kadamparai PH
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹69,000
Yes
7 Jul 2023
25 May 2023
2 Jun 2023
25 May 2023
1 Jun 2023
25 May 2023
Amount
Charges towards de-soldering both the pole jumpers, removing the ‘ V ‘ block and damper coils series link.
Charges towards removing the 8 Nos. static key and 8 Nos. sliding key per pole with special jigs and hydraulic jacks
Charges towards lifting of rotor poles after ensuring all connections are disconnected and by using suitable lifting device.
Charges towards removing the top coils by de-wedging and removing the overhang bandings with special jigs and fixtures
Charges towards removing the bottom coils by de-wedging and removing the overhang bandings with special jigs and fixtures.
Charges towards cleaning the carbon deposits completely with suitable method (dry ice cleaning).
Charges towards removing the old failed insulation and re-insulating on both sides overhang portion on released slot insulation healthy top coils and testing The following tests are to be carried out : 1) IR value at 5 KV before HVAC test 2) HVAC test at 18 KV 3)IR value at 5 KV after HVAC test
Charges towards removing the old failed insulations on slot portion and both overhang portions and re-insulating slot portion and both sides overhang portion with Class F insulation including testing. The following tests are to be carried out: i) IR value at 5 KV before HVAC test ii) HVAC test at 23 KV iii)IR value at 5 KV after HVAC test iv)Tan Delta and Capacitance Measurement.(This is applicable for those top coils where the slot insulation failed during HV test.)
Charges towards installing the spare/re-insulated tested bottom coils with Class F insulation (Spare coils shall be supplied by TANGEDCO) with using fresh liners, end banding the overhang portion with fiber tapes and cards using the binding cement of epoxy resin.
Charges for installing the spare/re-insulated tested top coils (Spare coils shall be supplied by TANGEDCO) with using fresh liners, wedges, end banding the overhang portion with fiber tapes and cards using the binding cement of epoxy resin, soldering the non-connection and connection side end ferrules and jumpers and insulating the jumper joints & providing end caps.
Charges towards replacing the worn-out wedges and tightening the coils in slots with new wedges and liners. (if necessary).
Charges towards removing the old bandings overhang portion of the coils cleaning with suitable cleaning agents, banding with epoxy resin and curing. (if necessary).
Charges for Re-soldering the non-connection and connection side end ferrules and jumpers and insulating the all joints
Charges for re-positioning the pole in the rotor spider, locking the keys, fixing the ’V’ blocks with suitable insulation
Charges for making end connection, locking the jumpers and connection links with suitable insulated locks, soldering the end connection.
Charges for cleaning of stator and rotor windings and drying out
Charges for following test on stator Stator: i) IR value at 5 KV megger before and after HV AC test. ii) HV AC as per instruction of field engineers. iii) PI value at 5 KV megger. iv) PI value v) Winding resistance vi) Tan Delta at 11 KV in the steps of 0.2VL, 0.4VL, 0.6VL, 0.8VL and 1.0 VL and Commissioning of machine
CGST in % (For Bidders inside TamilNadu)
SGST in % (For Bidders inside TamilNadu)
IGST in % (For Bidders outside TamilNadu)
SHREE ABIRAMI ENGGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .