Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-Finance 39 288 THANGAMAPURIPATNAM METTUR DAM 2 METTUR DAM 636 406 | METTUR DAM | SALEM | TAMIL NADU | 636406 | L1 | Accepted-Finance L1 |
Tender Value
₹4.6 L
EMD Value
₹4,600
Closing Date
16 May 2022, 2:00 pmClosed
SUPERINTENDING ENGINEER /ELECTRICAL SYSTEMS /MTPS1
Superintending Engineer Electrical Systems Mettur Thermal Power Station I Mettur Dam-636406
MTPSI ES Circle CI Division UnitIII Removal and refixing of pressure gauges Temperature gauges Switches Transmitter after calibration Replacement of Pneumatic cylinders terminals blocks and gaskets for all level switches cleaning of impulse lines an
2022_EB_230819_1
SE / ES / MTPS-I /CI/No 06/2022-23
Limited
Electrical Works
Works
15 days
MTPS1 METTUR DAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹4,600
Yes
18 May 2022
30 Apr 2022
17 May 2022
30 Apr 2022
16 May 2022
30 Apr 2022
30 Apr 2022 - 16 May 2022
Amount
Charges for removal of local pressure gauges/ temperature gauges and refixing them after calibration in Turbine & Generator areas.
Charges for removal of pressure/ Vacuum/flow switches and refixing them after calibration in Boiler, Turbine and Generator areas.
Charges for removal of existing transmitters including disconnecting the control cables, removal of clamps and manifold and refixing after calibration in Boiler, Turbine and Generator areas.
Charges for dismantling, cleaning & replacement of gaskets and re-fitting of level switches.
Charges for cutting of existing flange from stand pipe (4.5 inch) of HP Heaters stand pipe, grinding the surface in stand pipe, Welding of new flange in the stand pipe, providing new metallic gasket for new flange, fixing of new guided wave radar level transmitters.
Charges for removing and refitting of accessories in pneumatic control valves & dampers such as E/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing and receiving the tested instruments from lab.
Charges for replacement of HAD/CAD/FD cylinder.
Charges for replacement of burner tilt cylinder.
Charges for removal of existing PA Fan pneumatic actuator and its accessories with SS tubings from its location to pocket store.
Charges for loading, transporting and unloading of new keltron make pneumatic actuator from central stores to PA fan location.
Charges for digging of platform for bed arrangement and fabrication of MS plate suitable for actuator base including cutting, welding and drilling works for new bed bolt assembly
Charges for fixing the keltron pneumatic actuator in the new bed bolt assembly and refixing the accessories such as Air regulator, I/P converter with SS tubings and making alignment for the same.
Charges for removing the terminal connections, replacing the broken terminal blocks and reconnecting the terminal connections by checking various junction boxes in Boiler and Turbine area.
Charges for rectification and welding of broken doors in junction boxes.
Charges for opening and cleaning of all impulse lines and catch pots in mills, Flue gas, primary and secondary air paths.
Charges for single point cutting and welding of pipe size ½” impulse lines of mills, flue gas, primary and secondary air path including the cost of gas ,welding electrode and consumables.
Charges for replacement of defective 1” root valve in turbine area which involves the cutting and welding of 2 joints in 1” CS impulse line.
Charges for replacement of defective drain valve (3/8”) for high-pressure transmitter.
Charges for removing existing leaky 3/8” SS impulse line and worn out connectors, cutting and bending the new line as necessary, fixing SS connectors with nut and ferrule in the line and connecting back the new line without leaks in transmitters and actuators in services.
Charges for replacement of defective 1/2” SS instrument valve in various locations of boiler and turbine area.
Charges for removal and refixing of all types of RTD/thermocouples
Charges for patchup work in Field Instrument Enclosure (FIE) by providing temporary support for removing corroded portion, Erection new 3 mm plate in corroded area, Providing drain pipe line connected to FIE panel. 750X 600 X150.
Copper Washer (work Sl.No:1)
Teflon O-ring (woek Sl.No :3 )
Gasket (Champion 54 grade / Klinger 1000 grade) size 280 x 280 mm. (Work Sl.No:4)
Gasket (Champion 54 grade / Klinger 1000 grade) size 240 x 240 mm. (Work Sl.No:5)
2.5 Sq.mm Elmax Terminal Block (Work Sl.No:13)
2.5 mm CS welding rod electrode (90 Nos./Box)(Work Sl. Nos: 5,11, 14, 17,22)
Gas cutting for takeoff catch pot and 1/2” impulse line, bed etc… (Work Sl.No:5, 11, 17)
High pressure drain valve. (Work Sl.No:18)
Pad lock & Hinge (Work Sl.No:14)
Consumables ( work sl.No : 1 to 22 ) LUMSUM
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .