| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹25.0 L+₹1.1 L (4.71%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Higher rate | |
| 3 | L3₹28.1 L+₹4.2 L (17.5%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Higher rate | |
| 4 | L4₹31.2 L+₹7.3 L (30.6%)Rejected-AOC | L4 | Rejected-AOC Higher rate | |
| 5 | L5₹38.1 L+₹14.2 L (59.3%)Rejected-AOC | L5 | Rejected-AOC Higher rate |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
12 Aug 2020, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI ARMY HOSPITAL R AND R COMPLEX RAO TULA RAM MARG DELHI CANTT 10
MANNING AND OPERATION OF PUMP HOUSES AT RAKSHA BHAWAN AND REPAIR REPLACEMENT OF LT PANELS UG CABLE DG SET PUMP SETS AND STREET LIGHTS AT NDC AND RAKSHA BHAWAN UNDER GE NEW DELHI
2020_MES_359946_1
GE/ND-18/2020-21
Open Tender
Civil Works
Item Rate
330 days
GE NEW DELHI
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE NEW DELHI
₹92,000
Yes
15 Sept 2020
17 Jul 2020
14 Aug 2020
17 Jul 2020
12 Aug 2020
30 Jul 2020
Amount
Preventive maintenance of DG sets(75KVAX01, 62.5KVAX2, 25KVAX01 ) installed at different location of Raksha Bhawan & NDC .The following daily maint to be carried out as under:- (a) Check levels in oil through ,fuel tank coolant,gauge valve and replesh if necessary. (b) Re-grease all grease points. (c) Tighten the nuts bolts of pipeline of fuel oil ,lubricating oil,water and check for any leakages. (d) Check the water level in radiator and top up the coolant as required. (e) Clean oil filters/ Fuel filters. (f) Check viscosity of lub oil. (g) Check crank case for leakage. (h) Clean air filters. (i) Check the radiator fan belt condition. (j) Check distilled water for battery and top up. (k) Check battery cover condition from cover and battery voltage. (l) Check the metering equipment. (m) Check the insulation resistance of alternator. (n) Maintain log sheet and check list on daily basis.
M&L for"B" Check of DG set of following capacity at different location by taking out U/S spares, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, check the serviceability of AVR ,frequency etc , greasing oiling and changing oil,oil filter,fuel filter,,bypass filter,Air filter,water separator and radiator cleaning with chemical For smooth functioning of DG Set ( Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items .
75 KVA DG SET - 01 Nos
25 KVA DG SET - 01 Nos
62.5 KVA DG SET - 02 Nos
Servicing of Generator AMF Panel of following Gen set at diffirent location complete including labour for replacement of u/s spares, testing complete all as specified and directed (unserviceable spares required to be replaced shall be measured paid for separately under respective items .
75 KVA DG SET
25 KVA DG SET
62.5 KVA DG SET
Dismantling of 25 KVA DG Set Part i.e. Cylider head ,Turbo , Self repair and taking from the site to workshop for repair and assembling to the DG set including load testing of DG set
Cylinder liner with joint ring
Piston assembly complete
Gasket for cyl head (1.22mm)
Set of joints (for PG )/4H.3031
Set of O rings
Set copper washers
Inlet and exhuast valve pair
Valve guide (for inlet & exhuast)
Valve seat insert (inlet)
Valve seat insert (exhaust)
Valve seal
Valve collet
LE bearing STD
Spin on filter for lubricant ing oil
Primary Element
Secondary Element
Cylinder head repair
Turbo Repair kit
Injector Repair
Self repair
Taking down of FIP with nozzles from DG Set including servicing, testing, commissioning of Fuel Injection Pump (FIP) of 75 KVA DG Set including plunzer, setting of valves with nozzles and refixing of the same complete with all accessories all as specified and directed by Engr-in-Charge
Supply in replacement Fan belt suitable for 75 KVA DG set as per sample.
Supply in replacement Fan belt suitable for 62.5 KVA DG set as per sample.
Supply in replacement Diesel Filter for greaves DG set 75 KVA.
Supply in replacement Diesel Filter for kirloskar DG set 62.5 KVA.
Supply in replacement Diesel Filter for DG set 25 KVA.
Supply in replacement Oil filter for greaves DG set 75 KVA.
Supply in replacement Oil filter for kirloskar DG set 62.5 KVA.
Supply in replacement Oil filter for kirloskar DG set 25 KVA.
Supply in replacement temperature gauge for kirloskar DG set 75 KVA.
Supply in replacement lub Oil pressure gauge for kirloskar DG set 75 KVA.
M/L for cleaning of radiator by taking down radiator from DG set 75 KVA and refixing the same after cleaning of radiator with soda and acid including replacement of radiator foundation nuts bolts and rubber cussions.
M/L for cleaning of radiator by taking down radiator from DG set 62.5 KVA and refixing the same after cleaning of radiator with soda and acid including replacement of radiator foundation nuts bolts and rubber cussions.
Supply in replacement High pressure wire braided diesel pipe with benjo bolt from fuel tank to DG set of required length for DG Set 75,62.5 and 25 KVA.
Supply in replacement lubricant engine Oil 20 W 40.
Supply in replacement Coolant ready mix for radiator of DG set of capacity 62.5 and 75 KVA
M&L for servicing of exhaust system including replacement of minor faults,replacement of fan belt,greasing,oiling of the moving parts,wiring etc complete in all respect as per the direction of Engr-in-charge.
M&L for servicing of cooling system including replacement of minor faults,replacement of fan belt,greasing,oiling of the moving parts,wiring etc complete in all respect as per the direction of Engr-in-charge.
S&F in replacement air filters of the cooling system including taking down the existing choked filters as per sample all as specified and directed.
S & F in replacement change over switch 200Amps rated bus bar fixed with nut-bolt washer complete all as directed by Engr-in-Charge.
Supply and fixing kiosk pole box alongwith busbar of current rating 100 Amps 4 strip aluminium , mounting on DMC unbreakable insulator complete with 02 No MS flat bracket, nut, bolt and washer with 10 Amp MCB for each box.
Supply & fixing bracket for fixing street/ security light fitting made out of GI pipe medium grade 40 mm dia 1.20 Mtr long bent to required angle/ shape complete with MS flat iron clamp, nut, bolt, washer of suitable size as per site requirement etc and fixed in pole/wall including two coats of aiuminium paint over a coat of redoxide primer to MS clamps , nut ,bolts etc complete all as specified and directed by Engineer-in-Charge.
M&L for taking down serviceable/ unserviceable street/ security /Flood lights/Garden lights/ Gate lights of any type/size/rating including GI pipe bracket from the existing pole/ wall and stacking at site for requisite repair/ replacement and again refixing after necessary repair work all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement LED street light luminare pressure die cast aluminium housing with heat resistant toughened glass and IP 66 protection of 120 W,240V 50 Hz AC supply including taking down the existing light of any capacity. .Make:CG Pt No LSTO 120 CDL or equivalent
Supply and fix in replacement LED street light luminare pressure die cast aluminium housing with heat resistant toughened glass and IP 66 protection of 60 W,240V 50 Hz AC supply including taking down the existing light of any capacity.Make:CG Pt No LSTO 60 CDL or equivalent
Supply and fix in replacement LED street light luminare pressure die cast aluminium housing with heat resistant toughened glass and IP 66 protection of 45 W,240V 50 Hz AC supply including taking down the existing light of any capacity.Make:CG Pt No LSTO 45 CDL or equivalent
Supply & fixing in replacement LED street light luminare pressure die cast aluminium housing with heat resistant toughened glass and IP 65 protection 30 W 240V 50 Hz AC supply including taking down the existing light of any capacity.Make:CG Pt No LSTN 30 CDL or equivalent
Supply and fix in replacement miniature Circuit Breaker ( Conforms to IS 8828: 1996, IEC 60898:2002) 63 Amps, Triple Pole and Neutral, 240V, 50Hz, 10 KA.
Supply and fix in replacement miniature Circuit Breaker ( Conforms to IS 8828: 1996, IEC 60898:2002) 100 Amps, Triple Pole and Neutral, 240V, 50Hz, 10 KA.
S & F in replacement Strip heater 60/80Watt suitable for indoor panel of existing size/model complete all as specified and directed.
Filtration of existing Transformer Oil including heating to improve di- electric strength of Oil to minimum 60 KV BDV including testing of BDV of the filtered oil before & after all as directed.
Supply of low viscosity transformer oil to make up /top up oil for deficiency in transformers of 500 & 315KVA all as directed. Make- Power Oil (ISI marked on the sealed container).
Supply & filling of silca gel for 500KVA & 315 KVA all as specified.
Supply in replacement transformer Oil for top up of 500 & 315 KVA all as directed. Make- Power Oil (ISI marked on the sealed container).
Supply,installation,testing and commissioning of maintenance free earthing based on GI earthing electrode (Met-chem) 80 mm outer dia 3000 mm long duly filled with ITPC -EECP 15 fixed with nut bolts incl excavation/earth work in any strata and PCC chamber with CI frame and cover( earth pit not less than 3 mtr deep below ground level),with electrode surrounded by chemical(ITPC-EECP15)a mixture of sulphate, silica,iron oxide,nickle oxide,magnesium oxide,sodium oxide,zinc oxide etc(earth enhanced compound powder).Each earth should have resistance less than 1 ohm by using earth electrode used as per the site requirement.Chemical compound powder to be provide minimum 100 kg per site.GI strip of size 32 mmx 6 mm as earth continuity conductor will be provided as required length to connect the transformer including 225 mm x225 mm manhole cover will be provided. Make:ITPC/Model:Metchem CEE80/EECP-15/Inpocon/Ewain.
M&L for plate earthing for sub station equipments complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.0 mm thick buried directly in ground vertically (earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering GI pipe medium grade 20 mm bore complete with earth pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate and 50 mm thick RCC cover 1:2:4 type B-1,reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways all specified and shown in electrical plate No 3 of SSR Pt-I, including necessary excavation and earthwork, including test point and testing on completion. NOTE : Quoted rated shall be deemed to include main earthing lead/earth strip to test point upto 7.5 metre.
S&F earth continuity conductor of size 32 x 6 mm GI strip, fixed on wall/buried in ground with and including fixing arrangements as walls like dash fastner, nuts, bolts, screws, washer etc complete all as specefied and as directed.
Supply in replacement 3 pole power contactor ML 4 rating 70 A.
Supply and fix in replacement power capacitor 3 phase 25 KVAR of rated current 32.8 amp
Supply in replacement MCCB thermal magnetic release of 3 pole 400 A rupturing capacity 36 KA .Make Legrand/Havells/Indo Asian
Supply in replacement MCCB thermal magnetic release of 4 pole 250 A rupturing capacity 36 KA .Make Legrand/Havells/Indo Asian
Supply in replacement MCCB thermal magnetic release of 3 pole 125 A rupturing capacity 36 KA.Make Legrand/Havells/Indo Asian
Supply in replacement MCCB thermal magnetic release of 3 pole 160 A rupturing capacity 36 KA .Make Legrand/Havells/Indo Asian
Supply in replacement MCCB thermal magnetic release of 3 pole 100 A rupturing capacity 25 KA.Make Legrand/Havells/Indo Asian
S&F factory made epoxy powder coated distribution baord TP&N (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable management, top and bottom removable gland plastes with Knockout and suitable for one FP-MCCB 160 Amps as incomer and 24 SP MCBs or 8 TP MCBs (or any combination of SP/TP MCBs) outgoings complete all as specified and conforming to IS:8623 alongwith cable end box for above DBs.
Dismantling and taking down LT cable of any size
Supply and laying in replacement on wall and floor in cable trays cable XLPE insulated armoured LT 1100 volt grade with aluminium conductor size as given below complete all as specified and directed by Engr-in-Charge.
Size 16 sqmm two core Make-RR,Polycab,Havells.
Size 16 sqmm 4core Make-RR,Polycab,Havells.
Size 25 Sqmm 3.5 core.Make-RR,Polycab,Havells.
Size 35 Sqmm 3.5 core.Make-RR,Polycab,Havells.
Size 50 Sqmm 3.5 core.Make-RR,Polycab,Havells.
Size 70 Sqmm 3.5 core.Make-RR,Polycab,Havells.
Size 95 Sqmm 3.5 core.Make-RR,Polycab,Havells.
Size 150 Sqmm 3.5 core.Make-RR,Polycab,Havells.
Supply & fixing in replacement HRC Fuse fuse 40 Amps complete all as directed.
M&L for servicing and calibration of APFC relay panel of capacity 275 KVAR including replacement of minor faults,push button switch,wiring etc complete in all respect as per the direction of Engr-in-charge.
M&L for servicing and calibration of APFC relay panel of capacity 200 KVAR including replacement of minor faults,push button switch,wiring etc complete in all respect as per the direction of Engr-in-charge.
Supply and fix in replacement single phase electronic energy meter with LCD display having accuracy class 1.0 as per IS 13779 ISI marked with suitable CT, temper proof and capability to display reading in absence of power supply complete in all respect.
S&F in replacement of aluminium lugs of size 25 sq mm complete
S&F in replacement of aluminium lugs of size 35/ 50sq mm complete
S&F in replacement of aluminium lugs of size 70 / 95 sq mm complete
S&F in replacement of aluminium lugs of size 120 sq mm complete
S&F in replacement Power pack unit for battery back up 230 volt AC out put 110 volt DC, 7AH complete all as specified.
S&F in replacement Current transformer of 60:30/5+5 fixed in ACB panel of protection class 5P10 & metering clss -01 complete all as specified. Make- Cappa / Alstom / Saveo
M&L for disconnecting power supply from Circuit Breaker of capacity 630 Amps, taking out trolley unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part ,tightening/cleaning of CTs, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley , checking proper operation of trolley all as directed, inserting trolley inside and testing, and putting on load complete all as specified and directed.
S&F LT cable joint kit (heat shrink type) upto 120 Sqmm (ISI Maerked) complete all as specified and directed by Engineer-in-Charge Make-Raychen/Tension/3 m or equvelent
Lifting/ lowering of submersible pump motor of any capacity up to 80 mtrs deep in the ground with the help of ropes / chain pully incl nuts, bolts & clamps for repairing to work shop and after repairing refix the same with complete accessories in all respect as per the direction of Engr-in-charge.
Servicing of monoblock pump set of capacity 5 HP of any make / model by taking out U/S spares, by Dismantling / disconnecting the electric connection from motor and LT panel, opening monoblock pump and motor set from foundation and carrying to local work shop for repair and replacement of spares complete and refixing after repair, testing complete including transportation charges from site to work shop complete all as specified and directed by engr in charge (Unserviceable spares required to be replaced shall be measured paid for separately under respective items .
Servicing of monoblock pump set of capacity upto 7.5 HP of any make / model by taking out U/S spares, by Dismantling / disconnecting the electric connection from motor and LT panel, opening monoblock pump and motor set from foundation and carrying to local work shop for repair and replacement of spares complete and refixing after repair, testing complete including transportation charges from site to work shop complete all as specified and directed by engr in charge (Unserviceable spares required to be replaced shall be measured paid for separately under respective items .
Servicing of tube well Submersible pump set of capacity 7.5KW/10 Hp of any make / model , by lifting and Lowering of pump set and column pipe including water proof joint of submersible cable and connection , and carrying to local work shop for repair and replacement of spares complete and refixing after repair, testing complete including transportation charges from site to work shop complete all as specified and directed by engr in charge (Unserviceable spares required to be replaced shall be measured paid for separately under respective items .
S&F in Replacement of Ball bearing No : 6207,6308/C3 for motor as per sample.
M&L for re-winding of electric motor submersible of capacity 7.5KW/10 HP with copper super enamelled winding wire of same gauge with class H Insulation after taking out winding from stator and cleaning slots etc, varnishing, drying reassembling,testing complete all as specified and directed by Engr in charge
M&L for re-winding of electric motor submersible of capacity 7.5 HP with copper super enamelled winding wire of same gauge with class H Insulation after taking out winding from stator and cleaning slots etc, varnishing, drying reassembling,testing complete all as specified and directed by Engr in charge
Dismantling and taking out old unserviceable post lamp fitting and Supply and fix integral LED LANDSCAPE LIGHTING ,60 watts,Decorative Post top for 360° indirect light with IP 65 protection,Resistant to impact and corrosion, Glare-free and better uniformity with black painted MS pipe housing with all accessories complete with lamp all as specified and as directed Make-Crompton Cat No-MAPLE LPTO-60-CDL/M or Equvalent.
M&L for re-winding of electric motor submersible of capacity 5 HP with copper super enamelled winding wire of same gauge with class H Insulation after taking out winding from stator and cleaning slots etc, varnishing, drying reassembling,testing complete all as specified and directed by Engr in charge
M&L for re-winding of electric motor submersible of capacity 3 HP with copper super enamelled winding wire of same gauge with class H Insulation after taking out winding from stator and cleaning slots etc, varnishing, drying reassembling,testing complete all as specified and directed by Engr in charge
Supply in replacement gland packing for pump and motor whenever required.
M&L for spray painting with the existing colour paint after preparation of the existing damaged surface by scrapping the old rusted surface properly and writting the SM no on pumps and panels on the following:-
Water supply pump and motor of capacity 7.5 to 10 HP with base
Water supply pump and motor 5 HP with base
M & L in replacement of direct online starter suitable for 5 HP pumpset in steel sheet enclosure.
M & L in replacement of direct online starter suitable for 7.5HP pumpset in steel sheet enclosure.
M & L in replacement of submersible pump star delta starters 7.5KW/10 HP (Range 12-18 amps) in steel sheet enclosure suitable for 7.5/10 HP submersible pumpset complete.
M&L in replacement for sheet metal enclosure outdoor type for assembling the star delta starter suitable for item no 89 above and fixing it to wall complete with the help of angle iron if suitable size all as specified and directed.
Supply and laying in replacement GI pipe light grade of 50 mm dia for crossing road or fix on pole upto kiosk box including necessary clamps,nuts bolts etc including taking down old GI pipe all as specified and directed by engr in charge.
M&L for servicing of solar water heating system of capacity 2x1000 LPH including cleaning of solar panel externally and necessary insulation of the pipe line and testing of solar heating system after completion of the work all as specified.
M&L for descaling of tank and flat plate collector of the solar water heating system using descaling compound and then washing them with water complete all as specified
S&F in replacement heating element 3 KW, 240 volts, 50 Hz suitable for solar water heating unit including taking out old UNSV elements all as specified.
S&F in replacement thermostat 0-80C, 240 volts, 50 Hz suitable for solar water heating unit including taking out old UNSV thermostat all as specified.
M&L in replacement for insulation to 25 mm GI pipe line network with glass wool thermal insulation and properly wrapped with aluminium sheet alongwith entire length, wrap around pipe from tank/panel to all exposed portion including taking out old UNSV insulation complete all as specified & directed by Engr-in-charge after dismantling/taking out the unsv from the site.
Dismantling & taking down GI tubing any size
Supply & laying in replacement of GI tubing medium grade including all fittings such as elbow,socket nipple,union Tee Reducer of medium grade ISI Marked to be laid on the existing cable tray / walls/ floor of the following Sizes:-
100 mm bore
80 mm bore
50 mm bore
32 mm bore
25 mm bore
20 mm bore
15 mm bore
S&F in replacement Gun metal gate valve / globe valve heavy duty ISI marked of following sizes:-
50 mm dia.
40 mm dia.
25 mm dia.
20 mm dia.
15 mm dia.
S&F in replacement Cast Iron pipe 80 mm bore medium grade including necessary fittings such as socket , tee, reducer, bend, elbow,nipple, union etc, laid in trenches or fixed on wall/roof complete all as specified and directed.
S&F in replacement Cast Iron pipe 100 mm bore medium grade including necessary fittings such as socket , tee, reducer, bend, elbow,nipple, union etc, laid in trenches or fixed on wall/roof complete all as specified and directed.
S&F in replacement of foot valve heavy duty of size 80 mm dia ISI marked including flange joints.Make:Leader/zoloto/sant
S & F in replacemenT rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position,5000 ltrs capacity with ISI marked including all fittings such as elbow,socket nipple,union Tee all as directed by Engr-in-Charge
Supply and fix in replacement 2000 ltr capacity PVC rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top threaded type) three layered, hoisted and fixed in position complete all as specified and directed.
Supply and fix in replacement 1000 ltr capacity PVC rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top threaded type) three layered, hoisted and fixed in position complete all as specified and directed.
Supply and filling AQUAFIT brand calcium hypochlorite 65% to 70% chlorine content (in drum) in the form of granular and tablet form complete all as specified and directed.
M&L for Cleaning of RCC water Sump of capacity upto 50,000 gallons by wire brushing and bleaching the internal surface of sump with Bleaching powder, including removing all scales dust , pit dirt and mud, removing the sediments using pump to outside of defence land and carryout two coats of cement base paint on external exposed concrete/ plastered surface of under ground sump and endorsing date of cleaning on the outer wall of under ground sump with synthetic enamel paint with words not less than 50mm height complete all as specified and directed by Engineer-in-charge.
M&L for Cleaning of RCC under ground water Sump of capacity upto 35,000 gallons by wire brushing and bleaching the internal surface of sump with Bleaching powder, including removing all scales dust , pit dirt and mud, removing the sediments using pump to outside of defence land and carryout two coats of cement base paint on external exposed concrete/ plastered surface of under ground sump and endorsing date of cleaning on the outer wall of under ground sump with synthetic enamel paint with words not less than50mm height complete all as specified and directed by Engineer-in-charge.
Material & Labour for cleaning of rotational moulded PVC water storage service tanks of 5000 litres capacity on buildings by dewatering complete tank, removing sediments setteld at the bottom of tank and scraping the walls and bottom of tank and cleaning with bleaching powder solution, washing with clear water and wiriting the date of cleaning and due date of cleaning in white paint complete all as directed. Note: PVC water tanks clean in every 4 months
Ditto all as per Item No 98 ,but for PVC water storage service tanks of 2000 litres capacity
Ditto all as per Item No 98 ,but for PVC water storage service tanks of 1000 litres capacity
S&F in replacement ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for the following sizes.(Make Prayag/Zoloto/Polytuf)
For 25 mm bore GI pipe having minimum weight 455 gms
For 20 mm bore GI pipe having minimum weight 210 gms
M&L in replacement of PVC flat sheathed copper conductor 3 core submersible cable of 2.5 sq mm including taking down old unsv one complete all as specified.
M&L in replacement of PVC flat sheathed copper conductor 3 core submersible cable of 4.0 sq mm including taking down old unsv one complete all as specified.
S&F in replacement brass float valve assembly complete with high density plastic ball screwed for follwing sizes are as under :-
For 25mm bore GI Pipe having minimum weight
For 20mm bore GI Pipe having minimum weight
M & L for rewinding 10 HP motor of centrifugal pump with super enamelled copper wire of existing gauge including greasing, varnishing, insulating paper of appropraite class, drying varnishing etc including base repairs if required including cleaning and re-fixing complete all as specified and directed .
M & L for rewinding 7.5 HP motor of centrifugal pump with super enamelled copper wire of existing gauge including greasing, varnishing, insulating paper of appropraite class, drying varnishing etc including base repairs if required including cleaning and re-fixing complete all as specified and directed .
M & L for rewinding 5 HP motor of centrifugal pump with super enamelled copper wire of existing gauge including greasing, varnishing, insulating paper of appropraite class, drying varnishing etc including base repairs if required including cleaning and re-fixing complete all as specified and directed .
M & L for rewinding 3 HP motor of centrifugal pump with super enamelled copper wire of existing gauge including greasing, varnishing, insulating paper of appropraite class, drying varnishing etc including base repairs if required including cleaning and re-fixing complete all as specified and directed .
Manning, operation and routine/daily maintenance of pump house at Raksha Bhawan with one pump operator (FGM) in two shifts ( or Shift timing as per direction of Engr-in-Charge) eight hours each for supplying of water to married accommodation buildings at Raksha Bhawan by operating the following all as specified and as per details given below: - (a)Shift timing : 0600 to 1400 hrs , 1400 to 2200 hrs (b)Electrical driven centrifugal pumping set 3 to 10 HP capacity Make:- Kirloskar DSN-3 including LT Panel board, MCCB, DOL/Star Delta Starter, Voltmeter, Ammeter, Connection loads etc - 05 Nos. (c) Stand by Gen set - 62.5 KVA capacity. Make:- Kirloskar - Cummins including AMF panel and its accessories - 01 set. (d)Water storage sump 50000 gallons capacity - 02 Nos (e)Submersible pumping set 3 to 10 HP capacity - 02 Nos. (f)Internal electrification of installation, cleaning and keeping the installation in serviceable condition and supply and filling water in the service tanks at roof top of building in Block A,B,C & D and servant quarters by operating pumps/ valve complete all as specified and directed by Engineer-in-Charge. (g)FGM on duty will perform the duty of running the pumping sets, small/ minor repairs of pipe lines, opening and closing of the sluice valves/ gate valves/ stop cocks to ensure satisfactory supply of water round the clock alongwith satisfactory and smooth running of water supply installation. (h)Fuel required for DG set operation will be supplied by the department free of cost, filling assistance to be provided and record of the same shall be kept/maintained up to date jointly by the contractor's rep and MES rep. (i)Cleaning of Pump House area including cutting of grass and daily sweeping. Note:-The personnel employed by the contractor must have experience in relevant fields and having minimum 03 years of experience.
M/S ANIL KUMAR
RUCHIKA ENGG.WORKS
Surjit and Sons
AQUA GASEOUES CONTROLS INDIA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .