Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
10 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
CWE (AF) Secunderabad
CWE (AF) Secunderabad
SPECIAL REPAIR / REPLACEMENT OF HT NETWORK SYSTEM INCLUDING ALLIED WORK SERVICES AT AFS HAKIMPET
2026_MES_798322_1
84867/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Hakimpet
As per NIT
9 documents required · 9 mandatory
₹1,000
GE (AF) HAKIMPET
₹1.9 L
Yes
12 Nov 2026
12 Nov 2026
12 Dec 2026
12 Nov 2026
10 Dec 2026
3 Dec 2026
12 Nov 2026 - 30 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of 2 Pole stucture PCC Poles/Steel tubular poles of any size, type, make complete all as specified and as directed. | 1 | Each | 1.25 | ₹1.25 |
| 2 | Dismantling of 4 Pole stucture PCC Poles/Steel tubular poles of any size, type, make complete all as specified and as directed. | 1 | Each | 2.25 | ₹2.25 |
| 3 | Dismantling of ACSR conductor of any size, make, type complete all as specified and as directed. | 0.25 | Qtl | 3.25 | ₹0.81 |
| 4 | Dismantling of insulators of any type, make complete all as specified and as directed. | 15 | Each | 4.25 | ₹63.75 |
| 5 | Dismantling of Cross arms of MS Channel of any size, make, type complete all as specified and as directed. | 5 | Qtl | 5.25 | ₹26.25 |
| 6 | Supplying, laying, jointing, testing and commissioning HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 95 Sqmm, 3 core , laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking down of old cables complete all as specified and as directed.
NOTES :
(i) Payment for excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be made for separately.
Note :- The contractor provided testing team along with suitable testing equipment for testing of HT UG Cable before and after laying infront of Engr-in-Charge and submit the test results in a proper format. | 2,575 | RM | 6.25 | ₹16,093.75 |
| 7 | M&L cable jointing Kit for 11KV grade cable for outdoor termination, heat shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 Sqmm complete all as specified and as directed. | 17 | Each | 7.25 | ₹123.25 |
| 8 | M & L for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcol dust and common salt filling in alternate layers and electrode connected by galvanised iron strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers connected to test termination point protected by 40mm bore GI pipe light grade and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B1 including exluvation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in electrical plate No 3 of SSR Part I complete all as specified and as directed. | 14 | Each Job | 8.25 | ₹115.5 |
| 9 | Supply, installation and commissioning of 11 KV,rated voltage 11 KV, 630 A, non extensible, outdoor (IP 54), fixed type,SF6 insulated RMU (Ring Main Unit) 3-way with metering compartment alongwith measuring equipments i.e Multifunction meter, LT current transformer, Voltage transformer including relays Self powered Over current and Earth fault Relay (comprising of 2 Nos 630 Amps Load break switch as outgoing and 1 No vaccum circuit breaker as incoming) inside robotically welded stainless steel 304 (Non ferrous,Non magnetic grade) having IP- 67 grade protection and impulse withstand voltage 75 KV , rated power - frequency withstand voltage 28 KV/minute, rated frequency 50 Hz, rated short time breaking current 21 KA/ 3 sec . RMU should be provided with internal bus bars as well as earthing bus bar, one number fault passage indicator per unit pad lock provision & complete with accessories. The RMU shall be type tested for internal arc test of 21 KA/1 Sec as per IEC 62271-200. The earting of cable sheilds. The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP 54 protection. The unit shall include the following with all necessary standard fitting as required at site complete all as specified and as directed. | 1 | Each Job | 10.25 | ₹10.25 |
| 9.01 | (a) 02 Nos outgoing 630 Amps load break switch , triple pole single break 3 position (On, Off and earth having STC capacity 21 KA for 3 seconds with copper bus bar and copper earth bar fitted high fixed type voltage indicator device as per IEC 62271-103 fully rated with earth switch, spring assisted mechanism with built in operating handle, arc proof hinged type cable cover air insulated cable boxes and boots suitable for bottom front entry termination of 3 core cable 95/120/185 Sqmm. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
84867TENDERPDF.pdf
Tender Documents • 0.76 MB
BOQ_895575.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .