| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LQualified Make: BPL
Model: BPL - DF 2628 PHOENIX D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: BPL - DF 2628 PHOENIX | ₹1.2 L | L1 | Qualified |
| 2 | Disqualified Make: BPL
Model: 2509R BPL HARDOI HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | Make: BPL
Model: 2509R BPL | - | - | Disqualified |
| 3 | Disqualified Make: NA
Model: Aspen Diagnostics Pvt Ltd Other Technocare Medisystems 1 PROP SINGHAL MEDICAL AGENCIES OPP GAYATRI MANDIR A B ROAD GUNA MADHYA PRADESH 473001 | GUNA | MADHYA PRADESH | 473001 | Make: NA
Model: Aspen Diagnostics Pvt Ltd Other Technocare Medisystems | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jun 2018, 5:00 pmClosed
Non Invasive Cardiac Support Pump with Defibrillator Non Invasive Cardiac Support Pump With Defibrillator ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Product Specifications
Certifications and Warranty Cardiopulmonary resuscitation (CPR) Device
able to generate chest compression & provide consistent compression with on interruptions Yes - Easy to use in both Hospital and Emergency set up mainly during transportation Yes - with facility to provide chest compression to patient while carrying to staircase and even on 45 degree elevation Yes - Battery operated and with extremely simple user interface Yes - Ability to achieve uniform load distribution by squeezing entire chest Yes - Ability to do the high quality compression in CPR using: Chest compression band - 1/4 Should have small LCD backlit screen to show compression modes true - Display: Small LCD backlit screen to show compression modes - Ability to automatically size the patient by calculating size
shape and compliance of every patient: Yes - Capability to provide compression just by pressing buttons: 30:2 (30 compression and 2 ventilation pause ) compressions 30:2 (30 compression and 2 ventilation pause ) compressions
Continu ous compression Accessories Set (each unit of the equipment shall be supplied with 3 load distribution bands
1 battery charger unit and 3 batteries: Yes - Equipment unit should be according to AHA guidelines and can have capability to be upgradeable to any amendments in 2020 AHA guidelines onsite through IR Port or other facility available in unit Yes - Equipment has Defibrillator or providing synchronised shock while the device is working(imparting CPR to patient): Yes - Should be rugged and have easy to read three mode displays to be rugged and should have easy to read three mode displays to be readable in any environment Yes - Should have facility for ECG Monitoring
defibrillation
external pacing (transcutaneous) & recorder: Yes - Type of technology used in Defibrillator: Biphasic - 2/4 Energy selection range of Defibrillator 1 to 200 joules - Charging time of defibrillator unit: < 7 seconds to attain maximum energy - Defibrillator should have ability to measure chest compression rate and depth in real time and both visual and optional audible feedback is provided Yes - Ability that all CPR data can be recorded and reviewed by using software specially designed for doing this (if needed) Yes - Ability to filter out CPR artifacts and allowing person to see organized rhythms without interrupting chest compression Yes - Availability of voice and visual prompts and have GPS clock: Yes - Provision of Clock in defibrillator: GPS clock to provide complete time. - Unit have option to upgrade to Et CO2 false Unit have option to upgrade to Sp CO2 false Unit have option to upgrade to NIBP: false Unit have option to upgrade to 12 leads: false Certifications: US FDA - Warranty period: 3 years 3 years
5 years * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bal Krishan 208001
Ordnance Equipment Factory
Phool Bagh 1 30 EMD 3/4 Required No ePBG Required No
140722
GEM/2018/B/20080
Non Invasive Cardiac Support Pump with Defibrillator
30 days
Uttar Pradesh; Kanpur Nagar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Non Invasive Cardiac Support Pump with Defibrillator Non Invasive Cardiac Support Pump With Defibrillator ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Product Specifications | - | - | - |
| Certifications and Warranty Cardiopulmonary resuscitation (CPR) Device | - | - | - |
| able to generate chest compression & provide consistent compression with on interruptions Yes - Easy to use in both Hospital and Emergency set up mainly during transportation Yes - with facility to provide chest compression to patient while carrying to staircase and even on 45 degree elevation Yes - Battery operated and with extremely simple user interface Yes - Ability to achieve uniform load distribution by squeezing entire chest Yes - Ability to do the high quality compression in CPR using: Chest compression band - 1/4 Should have small LCD backlit screen to show compression modes true - Display: Small LCD backlit screen to show compression modes - Ability to automatically size the patient by calculating size | - | - | - |
| shape and compliance of every patient: Yes - Capability to provide compression just by pressing buttons: 30:2 (30 compression and 2 ventilation pause ) compressions 30:2 (30 compression and 2 ventilation pause ) compressions | - | - | - |
| Continu ous compression Accessories Set (each unit of the equipment shall be supplied with 3 load distribution bands | - | - | - |
| 1 battery charger unit and 3 batteries: Yes - Equipment unit should be according to AHA guidelines and can have capability to be upgradeable to any amendments in 2020 AHA guidelines onsite through IR Port or other facility available in unit Yes - Equipment has Defibrillator or providing synchronised shock while the device is working(imparting CPR to patient): Yes - Should be rugged and have easy to read three mode displays to be rugged and should have easy to read three mode displays to be readable in any environment Yes - Should have facility for ECG Monitoring | - | - | - |
| defibrillation | - | - | - |
| external pacing (transcutaneous) & recorder: Yes - Type of technology used in Defibrillator: Biphasic - 2/4 Energy selection range of Defibrillator 1 to 200 joules - Charging time of defibrillator unit: < 7 seconds to attain maximum energy - Defibrillator should have ability to measure chest compression rate and depth in real time and both visual and optional audible feedback is provided Yes - Ability that all CPR data can be recorded and reviewed by using software specially designed for doing this (if needed) Yes - Ability to filter out CPR artifacts and allowing person to see organized rhythms without interrupting chest compression Yes - Availability of voice and visual prompts and have GPS clock: Yes - Provision of Clock in defibrillator: GPS clock to provide complete time. - Unit have option to upgrade to Et CO2 false Unit have option to upgrade to Sp CO2 false Unit have option to upgrade to NIBP: false Unit have option to upgrade to 12 leads: false Certifications: US FDA - Warranty period: 3 years 3 years | - | - | - |
| 5 years * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bal Krishan 208001 | - | - | - |
| Ordnance Equipment Factory | - | - | - |
| Phool Bagh 1 30 EMD 3/4 Required No ePBG Required No | - | - | - |
Exempted
7 Jun 2018
28 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_140722.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .