Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.3 CrAccepted-AOC | ₹3.3 Cr | L-1 | Accepted-AOC Awarded the work with due approval from TPC-1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
10 Feb 2020, 12:00 pmClosed
Oo CGM_PPD APDCL
Oo CGM_PPD Bijulee Bhawan Paltan Bazar
Construction of 11KV line with bare and covered conductor with RMU and conversion of LT line etc
2020_APDCL_16067_1
SOPD 19-20/24x7 PS/Manas/36
Open Tender
Electrical Works
Turn-key
210 days
Manas Nationla Park Barpeta
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,000
APDCL
₹10 L
Oo CGM_PPD Bijulee Bhawan
5 Mar 2020
25 Jan 2020
10 Feb 2020
25 Jan 2020
10 Feb 2020
27 Jan 2020
27 Jan 2020
1.Construction of 11KV line - 7.5 km line with ACSR Raccoon conductor 2.Construction of 11KV line - 2.4 km line with Covered conductor 3.Installation of 11KV 4 way RMU near Fatemabad Tea Estate 4.Construction of 11KV line - 3.0 km double circuit line with ACSR Raccoon conductor 5.Construction of 5.1 KM 11KV line (Single circuit) using ACSR raccoon conductor 6.Construction of 11KV line - 0.3 km line with Covered conductor and 2.0 km line with ACSR raccoon conductor 7.Conversion of existing 1-ph LT line to 3-ph line with AB cable 8.Augmentation & installation of Distribution transformer under Barpeta Electrical Circle under SOPD 2019-20 on Turnkey mode of Contract.
Description of Work / Item(s)
Supply and erection of Transformer 11/0.4 kV, 250.0 kVA (4 star)
Supply ,fitting & fixing of GI Channel Cross Arm (75x40x6x2200)
Supply , fitting & fixing of MS pole clamp
Supply , fitting & fixing of 11 kV Polymeric Pin Insulator
Supply and erection of ACSR Raccoon conductor
Supply, fitting & fixing of 11 kV GOAB Switch, 150A
Supply ,fitting & fixing of 11 kV DO fuse set, 150A
Supply and erection of 12 kV lightning arrestor, 9 KA
Supply and erection of LT XLPE 1C, 240 sq.mm (Al)
Supply and erection of LT XLPE 1C, 120 sq.mm (Al)
Supply ,fitting & fixing of DTR cubical
Supply ,fitting & fixing of Bimetalic Lug (assorted size)
Supply ,fitting & fixing of GI Earth pipe 50mm dia, 3.0 Mtr long
Supply ,fitting & fixing of Hot dip GI Wire 6 SWG for Earthing
Supply ,fitting & fixing of MS Nuts & Bolts (Assorted) with Washer
Description of Work / Item(s)
Construction of 11KV line with ACSR Raccoon conductor on PSC pole 9.75 mtr length from Gabardhana Sub-station to Basbari Chowk 4-pole tapping point (Line length 7.5 km) (BOQ 3)
Construction of 11KV line ( four circuit) using 11KV covered conductor on steel pole SP 76 from RMU point near tea estate factory to Raghabi field 4-pole ( 4 nos of circuits of 600 mtr length each; total line length-2.4 km) (BOQ 4)
Installation of 11KV 4 way RMU near Fatemabad Tea Estate (BOQ 5)
Construction of 11KV line (double circuit) line using ACSR Raccoon conductor on steel tubular pole SP-76 from proposed 4-pole structure near Raghabil Play Ground (Line length-3.0km) (BOQ 6)
Construction of 11KV line (single circuit) using ACSR raccoon conductor on steel pole SP 76 from proposed 4 pole structure of Bahbari Chowk to Musa and Florican resort. (Line length- 5.1 km) (BOQ 7)
Construction of 11KV Manas dedicated feeder using 11KV covered conductor & ACSR raccoon conductor on PSC pole 9.75 mtr from Raghabil 4 pole to Barobasti (Total 2.3 km; 0.3km with covered conductor & 2.0 km with bare conductor) (BOQ 8)
Conversion of existing 1-ph LT line to 3-ph line with AB cable on PSC & GI steel tubular pole (Line length-3.0 km) (BOQ 9)
Augmentation of existing DTR & installation of 250 KVA DTR( Pad mounted) near Manas National Park. (BOQ 10)
Description of Work / Item(s)
Supply and erection of PSC pole, 9.75 mtrs. with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm
Supply ,fitting & fixing of GI Guard Channel cross arm (75x40x6 mm)
Supply ,fitting & fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply, fitting & fixing of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply ,fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply & erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply ,fitting & fixing of C. I. Earth pipe 1.8 Mtr
Supply ,fitting & fixing of G. I. wire , 8 SWG for guarding
Supply,fitting & fixing of G. I. wire , 6 SWG for earthing
Supply ,fitting & fixing of HT stay set with 11 KV guy insulator
Supply ,fitting & fixing of HT stay guy insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI LT Cross Arm
Supply, fitting & fixing of LT Pin Insulator with GI Pin
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Supply and erection of GI Steel Tubular Pole SP 76with grouting
Supply, fitting & fixing of GI Channel Cross arm (100x50x6x3200 mm)
Supply ,fitting & fixing of GI Angle 50x50x6
Supply ,fitting & fixing of 11 kV polymeric Tension Insulator, 90 KN with clamps, nut and bolts
Supply, fitting & fixing of 11 kV Tension Insulator hardware suitable for 70 sq. mm Covered Conductor with clamps, nuts & bolts
Supply, fitting & fixing of 11 kV polymeric Pin Insulator
Supply ,fitting & fixing of HT Danger Plate
Supply,fitting & fixing of 12 kV Lightning Arrestor, 9KA
Supply & erection of AAA Covered Conductor, 70 sq. mm
Supply, fitting & fixing of GI nuts & bolts with washer (assorted)
Supply ,fitting & fixing of CI earth pipe 1.8 mtr.
Supply ,fitting & fixing of 11 KV Wedge Connector for bare to CC connection
Supply,fitting & fixing of IPC (for connecting 70 sq. mm CC to CC)
Supply ,fitting & fixing of GI wire 6 SWG (for earthing)
Supply ,fitting & fixing of PVC Insulated Cable Ties (Top) for 11 kV Polymeric Insulator)
Supply, fitting & fitting of HT Stay Set
Supply, fitting & fitting of HT Guy Insulator
Supply, fitting & fixing of GI stay wire 7/10 SWG
Supply, fitting & fixing of GI Pole clamp
Supply, fitting & fixing of Barbed Wire Type A
Supply, fitting & fixing of Midspan Jointing Kit
Supply, fitting & fixing of 11 KV Termination kit suitable for 70 Sqmm CC
Description of Work / Item(s)
Supply and erection of 11 kV RMU (20 KA, 630A 4 Way extension including FRTU)
Supply, fitting & fixing of GI Channel 75x40x6x2200 mm for cable mounting on existing /new DP structure
Supply, fitting & fixing of GI Pipe 3.0 Mtr long, 50 mm dia
Supply and erection of 11 kV XLPE cable, 1C, 120 sq. mm (Al)
Supply, fitting & fixing of 11 kV cable kit for XLPE, 1C, 120 Sq. mm (out door)
Supply, fitting & fixing of 11 kV cable kit for XLPE, 1C, 120 Sq. mm (Indoor)
Supply, fitting & fixing of HT danger Plate
Supply, fitting & fixing of HDPE pipe 110 mm outer dia of 6 mtr length
Supply, fitting & fixing of GI wire 6 SWG
Description of Work / Item(s)
Supply and erection of GI Steel Tubular Pole SP 76. with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x3200) mm
Supply ,fitting & fixing of GI Guard Channel cross arm (75x40x6 mm)
Supply ,fitting & fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply ,fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply & erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply ,fitting & fixing of C. I. Earth pipe 1.8 Mtr
Supply ,fitting & fixing of G. I. wire , 8 SWG for guarding
Supply,fitting & fixing of G. I. wire , 6 SWG for earthing
Supply ,fitting & fixing of HT stay set with 11 KV guy insulator
Supply ,fitting & fixing of HT guy insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI LT Cross Arm
Supply, fitting & fixing of LT Pin Insulator with GI Pin
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Supply and erection of GI Steel Tubular Pole SP 76 with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm
Supply ,fitting & fixing of GI Guard Channel cross arm (75x40x6 mm)
Supply ,fitting & fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply, fitting & fixing of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply ,fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply & erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply ,fitting & fixing of C. I. Earth pipe 1.8 Mtr
Supply ,fitting & fixing of G. I. wire , 8 SWG for guarding
Supply,fitting & fixing of G. I. wire , 6 SWG for earthing
Supply ,fitting & fixing of HT stay set with 11 KV guy insulator
Supply ,fitting & fixing of HT stay guy insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI LT Cross Arm
Supply, fitting & fixing of LT Pin Insulator with GI Pin
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Supply and erection of PSC Pole 9.75 mtr with grouting
Supply, fitting & fixing of GI Channel Cross arm (100x50x6x2200 mm)
Supply ,fitting & fixing of GI Angle 50x50x6 (for cross bracing)
Supply ,fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply and erection og ACSR "Raccoon" conductor
Supply, fitting & fixing of 11 kV polymeric Tension Insulator, 90 KN with clamps, nut and bolts
Supply ,fitting & fixing of 11 kV Tension Insulator hardware suitable for 70 sq. mm Covered Conductor with clamps, nuts & bolts
Supply,fitting & fixing of 11 kV polymeric Pin Insulator
Supply , fitting & fixing of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply ,fitting & fixing of Tension clamp for "Raccoon" conductor
Supply ,fitting & fixing of HT Danger Plate
Supply and erection of 12 kV Lightning Arrestor, 9KA
Supply and erection of AAA Covered Conductor, 70 sq. mm
Supply ,fitting & fixing of GI nuts & bolts with washer (assorted)
Supply, fitting & fitting of CI earth pipe 1.8 mtr.
Supply, fitting & fitting of 11 KV Wedge Connector for bare to CC connection
Supply, fitting & fixing of GI wire 6 SWG (for earthing)
Supply, fitting & fixing of PVC Insulated Cable Ties (Top) for 11 kV Polymeric Insulator)
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Supply, fitting & fixing of Barbed Wire Type A
Supply, fitting & fixing of 11 KV Termination kit suitable for 70 Sqmm. CC
Description of Work / Item(s)
Supply and erection of PSC Pole 8.5 mtr with grouting
Supply and erection of GI Steel Tubular Pole SP 56 with grouting
Supply and erection of LT XLPE insulated ABC 3C x 120 sq. mm + 1C x 95 sq. mm (insulated messenger cum neutral)
Supply and erection of LT XLPE insulated ABC 3C x 70 sq. mm + 1C x 50 sq. mm (insulated messenger cum neutral)
Supply, fitting & fixing of Cable tie
Supply, fitting & fixing of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard
Supply ,fitting & fixing of Suspension clamp for L.T. A.B. cables as per NFC standard
Supply,fitting & fixing of Eye hook / eye bolt
Supply , fitting & fixing of Pole clamps of GI Flat 50x6 mm
Supply, fitting & fixing of Insulating Piercing Connector IPC P2x95 for DB charging as per NFC standard
Supply ,fitting & fixing of Insulating Piercing Connector IPC P2X95 for A.B. cable to A.B. cable TEE connection as per NFC standard
Supply ,fitting & fixing of Cable end caps for A.B. cables
Supply ,fitting & fixing of ASA distribution box (with pre fitted lug for service connection) for 1-phase, 6 connector, 140 Amps spring loaded busbar system
Supply ,fitting & fixing of ASA distribution box (with pre fitted lug for service connection) for 3-phase, 250 Amps spring loaded busbars, for 1 no. 3-phase input and 9 no. 3-phase outputs with 1.5 mtr. 3.5C x 25 Sq. mm PVC cable (Al conductor) for charging DB.
Supply ,fitting & fixing of Steel strap for installing DB (20 mm. width x 1.0 mtr long)
Supply, fitting & fitting of 10 sq. mm PVC cable per distribution box
Supply, fitting & fitting of Buckles for steel strap for DB fixing
Supply, fitting & fixing of Insulated waterproof bi-metallic lug for transformer connection ( 1 set contains 5 nos. of lugs per cable) as per NFC standard
Supply, fitting & fixing of Insulated crimping type midspan joint (1 set contains 5 no. ferrules per cable) as per NFC standard
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of Stay wire , 7/10 SWG
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of G. I. wire 6 swg. for earthing
Supply, fitting & fixing of CI earth pipe, 1.8 mtr, 100 mm dia
Supply, fitting & fixing of GI Channel 100x50x6x2200 mm for raighing height
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .