Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹7.7 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹8.4 Cr+₹70.3 L (9.11%)Rejected-Finance | ₹8.4 Cr+₹70.3 L (9.11%) | L2 | Rejected-Finance Being other than Lowest |
| 3 | L3₹9.0 Cr+₹1.3 Cr (16.6%)Rejected-Finance | ₹9.0 Cr+₹1.3 Cr (16.6%) | L3 | Rejected-Finance Being other than Lowest |
| 4 | L4₹9.2 Cr+₹1.4 Cr (18.6%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹9.2 Cr+₹1.4 Cr (18.6%) | L4 | Rejected-Finance Being other than Lowest |
| 5 | L5₹9.7 Cr+₹1.9 Cr (25.2%)Rejected-Finance | ₹9.7 Cr+₹1.9 Cr (25.2%) | L5 | Rejected-Finance Being other than Lowest |
Tender Value
Refer Docs
Closing Date
7 Apr 2021, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
AUGMENTATION OF EXISTING UNDERGROUND SUMP AT NEW NAVY NAGAR COLABA MUMBAI UNDER GE (NW) NAVY NAGAR COLABA MUMBAI (2ND CALL)
2021_MES_420957_2
8213/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Rate
270 days
GE (NW) NAVY NAGAR
Class S and above
7 documents required · 7 mandatory
₹3,000
Yes
GE (NW) Navy Nagar
Exempted
10 May 2021
29 Mar 2021
9 Apr 2021
29 Mar 2021
7 Apr 2021
31 Mar 2021
29 Mar 2021 - 31 Mar 2021
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, not exceeding 1.5 m deep and getting out in hard /dense soil complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, exceeding 1.5 m but not exceeding 3.0 m deep and getting out in Soft /disintegrated Rock complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, exceeding 3.0 m but not exceeding 4.50 m deep and getting out in Soft /disintegrated Rock complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, exceeding 4.50 m but not exceeding 6.0 m deep and getting out in Soft /disintegrated Rock complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, exceeding 6.0 m but not exceeding 7.50 m deep and getting out in Soft /disintegrated Rock complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, exceeding 7.50 m but not exceeding 9.0 m deep and getting out in Soft /disintegrated Rock complete all as specified and directed by Engineer-in-Charge.
Material & labour for hardcore of guage exceeding 63mm but not exceeding. 100 mm, deposited, spread and levelled in layers not exceeding. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Material & labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Material & labour for polythene film, 500 micron thick (virgin plastic), laid on a coat of bitumen primer, Vg10 @ 0.30 to 0.50 kg per sqm complete all as specified and directed by Engineer-in-Charge.
Material & labour for PCC type B2 (1:2:4) (40 mm graded aggregate) cement concrete in foundations, filling and mass-concrete complete all as specified and directed by Engineer-in-Charge.
Material & labour screed bed of bedding layer or mortar in CM (1:4) 50mm thick for laying floor finishes complete all as specified and directed by Engineer-in-Charge
Removing excavated hard / dense soil out side of MoD land complete all as specified and directed by Engineer-in-Charge. Note : Contractor should make his own arrangement for disposal of excavated material outside of the MoD land
Removing excavated soft / disintegrated rock out side of MoD land n complete all as specified and directed by Engineer-in-Charge. Note : Contractor should make his own arrangement for disposal of excavated material outside of the MoD land
Material & labour for RCC- M-30 (Design Mix) using 20mm graded aggregate integrated with high range water reducing admixture at the rate of 150ml per 50 kg bag of cement with integral cement water proofer and crystalline water proofer mixed at the rate as per manufacturers instructions for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.. (Note:- Admixture and WPC material shall be mesured and paid separately)
Use & Waste of formwork for rough finished surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge.
Material & labour for TMT steel of grade Fe 500D Corrosion resistance steel (CRS) with percentage elongation more than 16 %, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Material & labour for RCC- M-30 (Design Mix) using 20mm graded aggregate integrated with high range water reducing admixture at the rate of 150ml per 50 kg bag of cement with integral cement water proofer and crystalline water proofer mixed at the rate as per manufacturers instructions for walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footing including attached pilasters and buttresses complete all as specified and directed by Engineer-in-Charge.. (Note:- Admixture and WPC material shall be mesured and paid separately)
Use & Waste of formwork for rough finished surface to sides of concrete faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surfaces of concrete measured flat wall complete all as specified and directed by Engineer-in-Charge.
Material & labour for RCC- M-30 (Design Mix) using 20mm graded aggregate integrated with high range water reducing admixture at the rate of 150ml per 50 kg bag of cement and integral cement water proofer and crystalline water proofer mixed at the rate as per manufacturers instructions for Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge . (Note:- Admixture and WPC material shall be mesured and paid separately)
Use & Waste Form work for fair finished surfaces of concrete measured flat for sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer-in-Charge.
Material & labour TMT steel of grade Fe 500D Corrosion resistance steel (CRS) with percentage elongation more than 16 %, but 5 to 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and complete all as specified and directed.
Material & labour RCC- M-30 (Design Mix) using 20mm graded aggregate integrated with high range water reducing admixture at the rate of 150ml per 50 kg bag of cement and integral cement water proofer and crystalline water proofer mixed at the rate as per manufacturers instructions for Beams, cantilevers, bressummers, lintels over 1.5m span and complete all as specified and directed. (Note:- Admixture and WPC material shall be mesured and paid separately)
Use & Waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer-in-Charge.
Material & labour RCC- M-30(Design Mix) using 20mm graded aggregate integrated with high range water reducing admixture at the rate of 150ml per 50 kg bag of cement and integral cement water proofer and crystalline water proofer mixed at the rate as per manufacturers instructions for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and complete all as specified and directed. (Note:- Admixture and WPC material shall be mesured and paid separately)
Use & Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of concrete measured flat complete all as specified and directed by Engineer-in-Charge.
Use & Waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exceeding 20cm wide complete all as specified and directed by Engineer-in-Charge.
Supply only high range water reducing admixture complete all as specified and directed by Engineer-in-Charge. Make:- Fosroc /Fastflex Dr Fdot/ STP /CICO
Supply only Admixture integral cement water proofer mixed at the rate as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge. Make:- Fosroc /Fastflex Dr Fdot/ STP /CICO
Material & labour for rendering 10mm thick in CM (1:4) on ceilling concrete surfaces complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing splash stone (Granite stone) size 250mmx250mmx40mm thick over RCC pedastal top base slab with screed bed 20mm thick CM 1:3complete all as specified and directed by Engineer-in-Charge..
Supply & Fixing aluminium sheet of 16 guage thickness 200mm wide shall be placed as horizontal constuction joint in side wall in each construction joint in single piece complete all as specified and directed by Engineer-in-Charge.
Material & labour for Cast iron pipes 100mm dia with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches complete all as specified and directed by Engineer-in-Charge.
Material & labour for Cast iron pipes 150mm dia with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing For 100mm dia Cast Iron cowls complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Framed work as for Manhole, in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing 100mm Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified & directed by Engineer-in-Charge.
Material & labour for two coats of aluminium paint over a coat of red oxide zinc chrome primer over steel surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified & directed by Engineer-in-Charge.
Material & labour for water resistant rubberised (epoxy) bonding agent, over 50 mm thick concrete with 8mm aggregate with cement content 360 kg/cum for construction joints before starting the concrete over the surface complete all as specified and directed by Engineer-in-Charge.
Material & labour for two coats of acrylic polymer modified cementitious waterproofing coating after mixing two packs of different material as recommended by the manufacture on concrete surface including surface preparation complete all as specified and directed by Engineer-in-Charge.
Material & labour water proofing treatment and plaster for sump internal and external shall be applied as given below complete all as specified and directed by Engineer-in-Charge. :-
(i) Dampen all surfaces immediately ahead of acrylic cementitious waterproofing application. whilst the surface is still damp from saturation (SSD), apply one coat of sika top seal 109/ brush bond Fosroc /Fastflex Dr Fixit/ STP /CICO primer approx 200 gms/ sqm, as per manufacturer's instruction. (ii) Applying second coat of water proof elastic Acrylic modified waterproofing coating on the entire area and second coat shall be applied after 6-8 hrs of application of previous coat i.e. as mentioned here-in-before para (i) in the direction right angle to the previous coat. the waterproofing coating should be taken to a height of minimum 200 mm above the finished floor level on the vertical surface complete all as specified and directed by Engineer-in-Charge. (iii) Apply SIKA FABRIC 50 / FOSROC / Dr Fixit/ STP / CICO whilst the first coat is wet and then apply second coat complete all as specified and directed by Engineer-in-Charge. (iv) Apply a protection layer of 15 mm thick plaster made of (1:4) cement sand mortar admixed with integral waterproofing compound SIKACIM/ Fosroc /Dr Fixit/ STP / CICO confirming to IS: 2645 as per manufacturers instructions, over the applied waterproofing coating and broadcast with quartz sand to form mechanical key complete all as specified and directed by Engineer-in-Charge. Note:- Water proofing treatment shall be executed through autherised applicator only )
Material & labour for sealing of pipe penetration through the RCC slab or walls using SIKAGARD 694 F (I) /F0SROC / STP / DR Fixit/ CICO, around the perimeter of the pipe complete all as specified and directed by Engineer-in-Charge.
Material & labour for testing of UG Sump against leakage/seepage as per IS:3370. The rate of filling of water in underground sump shall be 300 mm depth per day and the testing of sump of water tightness shall be as per IS: 6494 complete all as specified and directed by Engineer-in-Charge. Note :- Potable Water shall only be used for testing the UG Sump
Use and waste of timbering as planking and Shuttering for excavations in over area and including use and waste if ranking shores and fixing and removing including wales, struts, open poling boards, etc if tightly driven close butt-jointed sheeting is ordered including packing cavities behind the sheeting with suitable material complete all as specified and directed by Engineer-in-Charge. Note : The item shall be executed as per IS 3764 : 1992 (Excavation work – Code of safety)
Material & labour RCC M30 (Design Mix) using 20mm graded aggregate for Columns, pillars, piers, posts and struts and complete all as specified and directed.
Material & labour RCC M30 (Design Mix) using 20mm graded aggregate for Beams, cantilevers, bressummers, lintels over 1.5m span and complete all as specified and directed.
Material & labour RCC M30(Design Mix) using 20mm graded aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and complete all as specified and directed.
Material & labour rendering 15mm thick in CM (1:6) on wall finished even and fair without using extra cement complete all as specified & directed by Engineer-in-Charge.
Material & labour Plastering on concrete surfaces of beams, lintels, walls etc, 20mm thick (15+5mm)in two coats in CM (1:4) , mixed with water proofing compound on fair faces of brick work or concrete surfaces, finished fair & even without using extra cement complete all as specified (WPC to be mixed in setting coat only and shall be measured and paid separately)
Material & labour rendering 5mm thick in CM (1:4) on concrete surface of ceiling, finished even and fair without using extra cement complete all as specified & directed by Engineer-in-Charge.
Supply only water proofing compound Fosroc/ Dr Fixit or equivalent as approved by GE
Material & labour applying two coat of oil bound emulsion distemper on new decorated surfaces over a coat of primer with a coat of wall putty including preparation of surface and complete all as specified & directed by Engineer-in-Charge.
Material & labour preparation of new undecorated surfaces of walls,soffit and applying two coats of weather proof Acrylic based paint(100% Acrylic) exterior grade over a coat of primer complete all as per manufacturers instructions all as specified & directed by Engineer-in-Charge.
Material & labour applying two coats of oil bound emulsion distemper on new decorated surfaces of ceiling including preparation of surface complete all as specified & directed by Engineer-in-Charge.
Material & labour for Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes complete all as specified & directed by Engineer-in-Charge.
Supply & fix for machine cut kota stone slab single piece length as in jambs/cills of windows 18-20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing (Note : kota stone single piece of Cill will be fixed in two steps) complete all as specified & directed by Engineer-in-Charge.
Material & labour machine cut pre-polished kota stone slab flooring 20-25mm thick over and including 15 mm thick cement screed base (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete Note :- The rate includes the cost of cement screed bed
Material & labour machine cut pre-polished kota stone slab in riser of steps, skirting, dado and pillar laid over and including 10 mm thick cement plaster in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete (Note : The rate includes the cost of cement plaster)
Supply & Fixing steel rolling shutters having thickness of lath 1.25mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop at of primer, erected in position as indicated, complete push pull or manual type complete all as specified & directed by Engineer-in-Charge.
Material & labour applying two coats of synthetic enamel paint over a coat red oxide on steel newly surfaces over 10cm width/girth incl preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing MS plates Fe 410-W, (Gde-E-250 quality A) (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde-E-165 complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing U PVC hinge/sliding type window with 5mm thick plain glass and stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm as moquitonet of approved quality including necessary hinges/rollers, handles and locking system complete all as specified & directed by Engineer-in-Charge.
Material & labour 100mm thick PCC Type D2, 1:4:8 (40mm graded agg ) as in sub base in flooring finished even and fair complete all as specified & directed by Engineer-in-Charge.
Material & labour Providing, cement concrete 1:2:4, type B-0 (12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified & directed by Engineer-in-Charge.
Material & labour coloured glazed parking tiles 300 x 300 x 10 mm thick, glossy finish (reflective type), any design (as approved by GE); set jointed and pointed in neat cement slurry over and including 20 mm thick cement screed in cm 1:6 complete all as specified & directed by Engineer-in-Charge.
Material & labour Brick work with sub class 'B' bricks straight or curved on planot exceeding 6m mean radius bult in cement mortor 1:6 complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5m in depth for Hard / dense soil and getting out complete all as specified & directed by Engineer-in-Charge.
Material & labour for walling of random rubble stone masonry (Granite or Trap Stone) uncoursed well bounded, bedded solidly hearted built in CM (1:6) complete all as specified and directed by Engineer-in-Charge
Material & labour PCC (1:4:8) Type D2, (40mm graded agg ) in foundations filling and mass concrete complete all as specified & directed by Engineer-in-Charge.
Material & labour for stainless steel special alloy grade 304 pipes as in railling incl required cutting, notching organ welding, riding and drilling counter sunk holes and bending to required shape by mechanical means in factory as per site requirement without forming wrinkles, buffing and polishing complete all as specified and directed by Engineer-in-Charge
Material & labour for stainless steel special alloy grade 304 circular base plate 100mm dia, 4mm thick incl circular sunk drilling holes, welding to MS base plate etc complete all as specified and directed.
Material & labour stainless steel grade 304 circular cap plate 110 mm dia 6 mm thick incl welding to stainless steel pipe, buffing & grinding etc complete all as specified & directed.
Material & labour for Granite(of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types complete all as specified & directed by Engineer-in-Charge.
Material & labour for 20mm thick Granite(of any type) tiles machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing of type complete all as specified & directed by Engineer-in-Charge.
Material & labour for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10cm girth & not but not exc 20 cm girth complete all as specified & directed by Engineer-in-Charge.
Material & labour for filleting in any position and to any shape of section area not exceeding 25 Sqcm in cement sand mortar 1:4 including all mitres, stops, etc complete all as specified & directed by Engineer-in-Charge.
Supply & fixing 110 mmm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-Charge.
Supply & fixing PVC bends of 110mm dia complete all as specified & directed by Engineer-in-Charge.
Material & labour for Plain cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) mixed with Shali Plast LW+ of STP/Pidilite URP of Dr. Fixit or Equivalent and appoved as per manufactures instruction. Before laying concrete surface shall be cleaned and a bond coat of slurry with Shali Crete URP (of STP) or quivalent with cement to be applied. Alll cracks in slab to be openend in 'V' groove and filled with Shali Fix RMC a Polymer Morter of STP/ equivalent complete all as specified & directed by Engineer-in-Charge.
Material & labour for 20mm thick rendering in CM (1:4) with the addition of Shaliplast LW+ @ 200ml per bag of cement on fair faces of brick or concrete surfaces all as directed by Engineer-in-Charge
Material & labour for protecting the roof including parapet wall with water proofing coating ,complete as specified below: (a) Clean the surface and apply one coat of primer (STP Shali Urethane BTD diluted in water in 1:1 ratio and applied @ 400 gm/sqm OR Dr, Fixit primeseal diluted in water in 2:1 ratio and applied @ 7-8 sqm/ltr) and allows to dry for 6 to 8 hrs. (b) Apply first coat of water proofing coating over primer surface (Shali Urethene BTD with non butuminous bleding of STP Ltd. @ 1 Sqm/Ltr without dilution OR Dr. Fixit New Coat without any dilution @ 2 Sqm /Ltr) (c) Lay Non woven fiber glass mesh (Reinforcement of Shali Geo Text 40/50 gsm of size 2.5mm x 2.5mm) or equivalent with overlap of 50 mm on both direction while the first coat is still wet. (d) Apply second coat of water proofing coating as per manufactures instruction after 6-8 hrs of drying of first coat. (e) Apply third coat of water proofing coating (as per manucturer instruction) after 6-8 hrs of drying of second coat The total thickness of 1 to 1.2mm must be achieved after 7 days of air cure. Note :- 1. The colour of each coat shall be as directed by GE. 2 . The work shall be carried out by aithorised applicator only 3. Water proofing to rain water spouts to be done as per manufacturer instruction
Excavation over areas, exc 1.5m but not exc. 3.00 m deep and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Excavation over area, exc 3.00m but not exc 4.50m deep and getting out in hard/dense soil complete all as specified and directed by Engr-in Charge.
Excavation over areas, exc 4.5m but not exc. 6.00 m deep and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Excavation over areas, exc 4.5m but not exc. 6.00 m deep and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Excavation over areas, exc 6.00m but not exc. 7.50 m deep and getting out in hard rock complete all as specified and directed by Engineer-in-Charge.
Removing excavated hard/dense soil exc 0.50km but not exc 3.00km from starting point and deposting were directed at a level not exceeding. 1.50mtr above the starting point complete all as specified and directed by Engineer-in-Charge. (Note : The item will be measured for removal from site of excavation and stacking point. If the material is ordered to use for returning filling, same shall be measured and paid separately)
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm hard/dense soil and complete all as specified and directed.
Supply only Admixture crystalline water proofer mixed at the rate as per manufacturers instructions complete all specified and directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed withearth around in layers not exceeding 25cm watering and removing surplus soil to a distance not exceeding 50m and making goog and complete all as directed.
Material & labour Mild steel work as in (angle iron) as in flat iron, fencing post, struts incl cutting top shape as directed bent to shape drilling holes, notching for wire etc complete confirming to fe-290 Gde E-165 complete all as directed.
Supply only pre-painted MS galvanized chain link fencing of approved thickness and size or type complete all as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. (Note : Supply of chain link will be measured separately).
Supply & fixing Mild steel round bars 10mm dia and over for securing chain link fencing cut to length bend to shape required incl binding bolting etc complete confirming to Fe-410-W (Gde E-250) quality- A / Fe-290 (GdeE-165) complete all as specified.
Supply & fixing mild steel screw bolt (machine made 11 to 15mm dia of shank with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed and to fitted with washers and one hexagonal or square nut length of bolt not exceeding 5cm long complete all as specified.
Material & labour rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails , braces etc, complete drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and inc, either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other conering, running rails and guides) and hangings also fasterning and fixing completeFe-410-W (Gde E-250) quality- A / Fe-290 (GdeE-165) and complete all as specified
Material & labour for Concealed conduit point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked not less than 25 mm thick, ISI mark with all accessories on wall/celling/floor/roof etc,suitable size of PVC board ISI marked for fixing of switches and sockets complete ISI marked with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- Make of cable: Finolex/L&T/Havells/Anchor. Make for PVC conduit : Poly plast/pressfit /Presto-plast/ Precision.
One light/ fan/ E'fan point controlled by one switch
One 3 pin socket outlet, 5 Amps on the same board with other switches.
One 3 pin socket outlet, 5 Amps, independent
Material & labour for point wiring complete with proper colour coding using, 1100 volts grade, 2.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC conduit not less than 25 mm thick, ISI mark with all accessories, fixing on wall/celling/floor/roof etc,suitable size of PVC board ISI marked for fixing of switches and sockets complete ISI marked with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for 15 Amp power point.
Supply & fixing switch piano, flush type, single pole, one way 5 Amps, 240 Volts. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fixing switch socket combination 2 in 1, 5A flush type, ISI marked, 240 Volts, all as specified. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fixing switch socket combination, ISI marked flush type, multipurpose 3 pin, 15 Amps and one pin 5 Amps controlled by one switch all as specified. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fixing stepped type (5 step) electronic fan regulator 230 volts ISI marked and connecting up complete. Make: Anchor model No 1452 Delux fan regulator rotary type or equivalent in Crabtree/ Bajaj/ CG.
Supply & fixing ceiling rose surface bakelite 65x50 mm with 3 terminals. Make: Leader/ Kinjal/ Crabtree/ Anchor.
Supply & fix LED tube light fitting 4 feet long with high efficent LEDs with clear diffuser of capacity 20 watt including connection with connecting accessories and fixed on its original position all as specified and directed. Make-C & S/ Philips/Wipro/ Havells/ Bajaj.
Material & labour for sheet metal enclosure for DBs when MCB 'C' characterstic, 10 KA to be used single phase 8 way, double door,240V having Din rail, Neutral & Earthing bar as per IS-8828 of 1996 DB sheet not less than 1.2mm with powder paint, min ingress protection shall be IP20, label indicators shall be provided over all incoming/outgoing circuit complete all as specified and directed.Make - LEGRAND Cat part No: 607711 or its equivalent in Siemens/ Hagar/ Schneider as approved by GE.
Supply & fixing MCB SPN, up to 32 Amp, 10 KA, 230 Volt.Make - LEGRAND Cat part No: 603231/33/34 or its equivalent in Siemens/ Hagar/ Schneider as approved by GE.
Supply & fixing MCB, single pole, upto 16 Amp, 10 KA, 230 Volt.Make - LEGRAND Cat part No: 603231/33/34 or its equivalent in Siemens/ Hagar/ Schneider as approved by GE.
Supply & fixing cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable on wall/ roof/ duct complete and connecting to DBs with glands including taking out existing damaged cables and all as directed. Make-Polycab/plaza/Finolex/RR
Supply & fix ceiling fan 1200 mm sweep, 230 V, 50 Hz, minimum 5 star rating and energy saving, hanging on ceiling and connect with copper conductor multi stranded 3 core wire of size 14/0.0076 including taking out old US one. Make - Havells model No. ES 40 or equivalent to Khaitan/ CG/ Havells as approved by GE.
Supply & fix Exhaust fan 300mm sweep, 230 V, 50 Hz, having power input 70 W, speed 1440 RPM, with protective bird guard including connection as required at site with flexible copper cable complete all as specified and as directed by Engineer-in-Charge and as per Hevells model-VENTIL AIR DB or equivalent in Khaitan/USHA/Havells as approved by GE
Material & labour for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engineer-in-Charge including testing on completion.
Supply and fixing Security lighting luminaire for use with LED lamps, of capacity not less than 20 watts, 240 Volts, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-65 class of protection, complete with control gear and all accessories fixed with 25 mm bore Light grade GI Pipe Bracket 1.2 mtr long bent to shape, Fixed on wall with MS Flat Clamps, nuts & Bolts complete all as speciifed. Make : Havells Cat No. LHETAXU7UN6J020 or Equivalent of Philips Cat No BRP022 LED 20 CW MR S1 PSU GR/Bajaj as approved by GE
Material & labour Wiring for circuit/submain wiring alongwith earth wire with the following 2x2.5 sq. mm + 1x1.5 Sqmm earth wire in PVC Conduit for secuirty lighting .All as per directed by Engineer-in-Charge
Supplying, Installing Testing & Commissioning of Indoor type Programmable Logic Controller based Pump and Valve Automation, Protection and communication Panel (GPRS & OFC ) suitable for control and/or monitoring of 03 Nos Centrifugal pumps, 08 Nos. motorized valves, 03 Nos priming valves, 03 Nos air release solenoid valves, 02 Nos Ultrasonic level sensor, 03 Nos Pressure transmitters and 04 nos level switches.The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated with angle iron supports not less than 40 mm x 40 mm x 5mm size. The Panel should comprise the following items: (a) ULS Sensing & HMI Display (b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention (h) Manual Mode Operation all connected sub systems including all valves (in pump houses and connected buildings / overhead tanks) and pumps from the PLC based Control Panel . Make of Control Panel: Cimcon Software Pvt Ltd/ Reckronic Devices and Systems / Sombansi Enviro Engg Pvt Ltd/ Siemens/ Schneider/Universal Switchgear.
vii)SITC of rack mountable web smart switch with 28 ports and POE for CPE hardware--1 Each and following specifications 1) Number of Ports 24 10/100Base-TX Ethernet ports 2 ,10/100/1000BASE-T 2 Combo 10/100/1000BASE-T/SFP ii) Port StandardSupply & Fixingunctions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps Make : Siemens, Dlink, Ubiquiti, Cisco (viii) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/9µm respectively in a metal housing to reduce EMI and to increase durability-2 Each Make : Dlink, Ubiquiti, Cisco, Siemens, HP
(IX)Rack Mountable LIU -1 Each with the following specifications (1) Rack Mountable 12 Port Unloaded LIU (a) Aluminium Base Material (b) Slim 1 U mounting height (c) Metal Shelf Aluminium 1.2 mm thick (d) Splice tray Aluminium 0.6mm (e) Winding Panel – Plastic (f) Cable Plug – Rubber for minimum 2 cable entries (g) Adaptor Panel Aluminium 1.5 mm thick (h) 2 fiber spools built in for 900 um tight buffered fibre storing (i) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptor Make : Dlink, Ubiquiti, Cisco (X) SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length-6 Each (a) Size 0.9mm dia (b) Insertion Loss <=0.2 db, max 0.3 db (c) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (d) Connector Ferrule Ceramic (e) Apex Offset <50um (f) Fiber Height +-100nm (g) End Face Radius of Curvature 7mm<R<25mm (h) Repeatability <=0.2 dB 1,000 times mating cycles (i) Working Temp -40deg C to +85 deg C Make : Dlink, Ubiquiti, Cisco
(XI)CAT6 UTP 24 AWG Patch Cord of suitable length, Plug 30U snag less -2Each Make : Dlink, Finolex,Polycab (XII)CAT 6 UTP cable on walls-1RMs Make : D Link, Finolex, Polycab (Xiii)SC-SM-Simplex Pigtail of suitable length-8 Each (a) Insertion Loss <=0.2 db, max 0.3 db (b) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (c) Connector Ferrule Ceramic (d) Apex Offset <50um (e) Fiber Height +-100nm (f) End Face Radius of Curvature 7mm<R<25mm (g) Repeatability <=0.2 dB 1,000 times mating cycles (h) Working Temp -40deg C to +85 deg C Make : Dlink, Ubiquiti, Cisco (XIV)SC Simplex Coupler/Adaptor-4 Each (a) Insertion Loss <=0.2 dB for Zirconia Sleeve (b) Sleeve/Ferrule Withdrawl Force 2.0N to 5.9N Make : Dlink, Ubiquiti, Cisco
Supplying, Installing Testing & Commissioning of Motor Actuated Butterfly valve 150mm direct mounted consisting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. SpecificationSupply & Fixingeatures Input Voltage: 230 V, A.C.
Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct, Make: Motor :-EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL Butterfly valve:-L&T / Zoloto / Kirloskar
Supply and fix ball type foot valve of 150mm dia 10/15Kg/sqcm (MODEL B-5) of make NORMEX (ISI marked) in position at location including Material & labour for making flanged joints of 150 mm size as directed by Engineer In Charge. Make:- Normax/Kartar/Kirloskar
Construction of brick masonry valve chamber of size 1.2 x 1.2 x 1.2m (Internal dimension) (above GL 1.0mtr) suitable for installation motor actuated butterfly valve extended type suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embedded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces, earth work, in any type soil returing filling and removal complete all as specified and directed by Engineer-in-Charge.
Supply and laying With spigot and socket type ductile iron pipe K-9 conforming IS 8329 : 2000 in any length laid in trenches of following bore complete all as directed by Engineer-in-Charge. Make :- Electro steel castings Ltd / Jindal saw Ltd / TATA mataliks / Electrotherm (India) Ltd
300 mm bore
150 mm bore
100 mm bore
Supplying, installation, testing and commissioning of Electric driven Pump with following requirements complete all as specified and directed by Engineer-in-Charge. (a)75 HP at head of 37 Mtr,Size In mm(Suc x Del) 150x150 , Horizontal type, centrifugal, split casing pump body made up of cast iron & enclosed type impeller made up bronze with stainless steel shaft,with suitable sealing,galnd packing conforming to IS 1520. (b)suitable Squirrel cage IE-2 induction motor ,TEFC, synchronous speed 2900 RPM, suitable for operation. on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate,coupling guard, Pressure guage foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads,painting of blue colour to suction and dilivery pipe line (e)one coat of red lead primer of best quality (IS approved ) shall be applied. Finally two (2) coats of Synthetic enamel paint of best quality(IS approved) colour shall be applied Note:Contractors is required to submit pump performance curves and pump efficiency at site. Motor Make:Kirloskar / Mather & Platt / Crompton Greaves. Pump make:Kirloskar / Mather & Platt / Jyothi pumps.
Supply and fixing PVC Water storage tank of capacity 5000 ltr three layer including foundation at desired location complete all as specified and directed by Engineer-in-Charge including testing on completion.
Supply and fixing gun metal gate valve of 50 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fixing brass ball valve high pressure,with polythene float and fly nut and connected items of size 50mm complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary of dia 50 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary of dia 25 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply & fixing on wall/ laying in trench 6core 0.5 Sqmm PVC sheathed and PVC insulated, armoured, Copper cable complete all as specified and directed by Engineer-in-Charge.
Supplying, Installing Testing & Commissioning of pressure Transmitter with following specification including necessary power pack for supply of DC : Power supply: 10-36 V DC Process connection: G ½ “ Enclosure: whether proof IP 65 Process temperature: -30 to 120 celcius Accuracy: 0.25 % Make: Danfoss / Siemens / E & H
Supplying, Installing Testing & Commissioning of motor actuated ball valve suitable for 25 mm GI pipe for priming of pump including all necessary GI fittings complete all as specified and directed by Engineer-in-Charge with following specifications.: Size: 25 mm Pressure rating: 10 kg / sq. cm. Make: Danfoss / Siemens / E & H
Supplying, Installing Testing & Commissioning of direct acting type release solenoid valve for air release during priming complete all as specified and directed by Engineer-in-Charge with follwing specifications : Size: 10 mm Pressure rating: 10 kg / sq. cm. Type: Normally closed Make: Danfoss / Siemens / E & H
Supplying, installing, testing and comissioning of LT distribution panel of suitable size, CPRI type tested, weather/vermin proof, made out of 2mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, indoor type, with front and backside doors with locking arrangement, floor mounted free standing type, duly powder coated bus bar with epoxy insulated coating with cable galleries With soft starter for 75 HP Bus bar size 50x40mm comprising of following units:- (a) 415V MCCB 4P 400 A with thermal magnetic protection unit and thermal adjustable 0.8 to 1 In,Magnetic adjustable 5 to 10In and breaking capacity of 36KA with suitable spreaders-1 No. (b) 415 V MCCB 3 P 160 A with thermal magnetic protection unit and thermal adjustable 0.8 to 1 In, Magnetic adjustable 5 to 10In and breaking capacity of 36KA with suitable spreaders-3 No's (c) Soft starter Minimum switching current 10 mA at 6 V DC for relay outputs, Maximum switching current Logic output 0.2 A at 30 V DC Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5,Starting current 0.4...1.3 Icl adjustable 3 Nos Analogue output type current output AO: 0-20 mA or 4-20 mA, impedance <500 (d) S &F Multimeter with suitable CT and PT 0 to 300 Amp and 0 to 500 Volts – 04 Nos (e) LED phase indicator – 04 Sets (RYB)
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and debris out side MoD land complete all as specified and directed by Engineer-in-Charge.
Material & labour for cement concrete (1:2:4), type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
Removing excavated material exc 150 M but not exceeding 500 M and depositing where directed complete all as specified and directed by Engineer-in-Charge.
Material & labour for for DI specials conforming to IS - 1538, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
Supply fixing ISI marked Push-on Joints (Rubber Ring) of EPDM material confirming to IS 672:1999 as 1646:1992.Suitable for DI Pipe including testing against leakage complete all as specified and directed by Engineer-in-Charge.
100 mm dia
150 mm dia
300 mm dia
Supply and laying in trenches/through pipes or bare in road crossings / paths / drains / ducts / floors / along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area185Sq MM 3.5 Core complete all as specified and directed by Engineer-in-Charge. Make:-Polycab/Havells/ R R Cable
Supply & fixing on wall/ laying in trench 5 pair 0.5 sq mm PVC sheathed and PVC insulated, armoured, Copper cable complete all as specified and directed by Engineer-in-Charge. Make:-Polycab/Havells/ R R Cable
Supply & fixing on wall/ laying in trench4 pair 0.5 sq mm PVC sheathed and PVC insulated, armoured, Copper cable complete all as specified and directed by Engineer-in-Charge. Make:-Polycab/Havells/ R R Cable
Supply & fixing on wall/ laying in trench 2 pair 0.5 sq mm PVC sheathed and PVC insulated, armoured, Copper cable complete all as specified and directed by Engineer-in-Charge. Make:-Polycab/Havells/ R R Cable
Supply & fixing on wall/ laying in trench High density polyethylene pipes (HDPE) OF 50 mm dia of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing CAT6E 4 Pair Unshielded Twisted Pair Utp LAN Cable confirming ISO - 9002 Make:-Polycab/Havells/ R R Cable complete all as specified and directed by Engineer-in-Charge.
Supply, Installation Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specification. Input Voltage: 230 V, A.C. L Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Extended type of following size Make : Motor :- EMTORK / HASEL HOFENER / RITETORK / SIEMENS / HONEY WELL Butterfly valve :- L&T, Zoloto, Kirloskar
150 mm bore
100 mm bore
Supply, Installing,Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 metres Accuracy : 0.5 % minimum Supply Voltage : 24V dc Output : 4-20 mA Ultrasonic Frequency:75 kHz burst, rep. rate 96 ms Delay at Power-up: 1.5 seconds Temperature Effect: Uncompensated: 0.2% of distance/°C &Compensated: 0.02% of distance/°C Delay at Power-up: 1.5 seconds Resolution: 1.0 mm Output Response Time: 100 ms to 2300 ms Minimum Window Size: 20 mm Environmental Rating: Leakproof design is rated IEC IP67; NEMA 6P Operating Conditions: Temperature: –20 °C to 70 °C (–4 °F to 158 °F) Maximum relative humidity: 100% Indicators Green Power On LED: Indicates power is ON Red Signal LED: Indicates target is within sensing range, and the condition of the received signal Teach/Output indicator (bicolor Amber/Red): Amber – Target is within taught limits; Flashing Amber – Target is outside taught window limits; Red – Sensor is in TEACH mode Makes : Endress+Hauser / Banner / Krohne Marshal / Siemens
Disconnecting Centrifugal pump set from Starter panal and foundation Pipe line NRV,Foot valve of capacity 120 HP/84 KW from chenab Pump house and install at New pump house near Chenab Building including making suitablefoundation complete all as specified & directed by Engineer-in-Charge.
Disconnecting Centrifugal pump set from Starter panal and foundation Pipe line NRV,Foot valve of capacity 75HP/55 KW from Kanya Pump house and install at New pump house near Chenab Building including making suitable foundation complete all as specified & directed by Engineer-in-Charge.
Disconnecting LT Panel From Chenab pump house and shift and install at New pump house near Chenab building including making suitable foundation complete all as specified & directed by Engineer-in-Charge.
Disconnecting LT Panel From Kanya Pump house and shift and install at New pump house near Chenab building complete all as specified & directed by Engineer-in-Charge.
Supply & fix 150mm dia Non return valve swing type all as specified & directed by Engineer-In-Charge and quoted rates deemed to be inclusive of welding flange complete all as specified & directed by Engineer-in-Charge.
Supply & fixing 150mm dia ERW MS pipe and applying two coats of synthetic enamel paint over a coat of red oxide primer to pipe including supporting brackets. Make :- Jindal / TATA / Zenith / BSt
Supply & fixing on wall / laying in trench high density polyethylene pipes (HDPE) of 100mm dia of pressure rating 6 kgf/cm2 laid in trenches
Supply & fixing GI perforated Pre-Galvanised cable tray 300mm (W) X 40MM(H) x 14swg thick with covers with suitable No of C Type clamps, Electro galvanized nut, bolt & washers & couplers. Note : The cost for bailing out of water including all necessary arrangements (Tools, Equipments, & manpower) during entire period of execution of work as required are deemed to be included in the unit rate quoted of each item.
MC Gandhi and Sons
Mukund Enterprises Private Limited
Phoenix Infra
Baka Construction
MUKESH CONSTRUCTION CO
JAI CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .