Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAdmitted-Finance | ₹2.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.8 CrAdmitted-Finance A 18 GR FLOOR SITA ESTATE AZIZ BAUGH MAHUL ROAD CHEMBUR E MUMBAI 400 074 | MUMBAI SUBURBAN | MAHARASHTRA | 400074 | ₹2.8 Cr | L2 | Admitted-Finance |
| 3 | L3₹3.1 CrAdmitted-Finance 1ST FLOOR 29A SESHAADHRI NILAY D NEOG PATH BEHIND DONA PLANET ANANDA NAGAR G S ROAD GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | ₹3.1 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Dis-Qualify |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Hardcopy of Technical Bid Not received |
| Sl No | Description | Qty | Unit | Kalpaka Power Control L2 | Power Tools and Engineering L3 | Deep Electricals L1 |
|---|---|---|---|---|---|---|
| 1.00Diesel engineer and alternator | ||||||
| 2.00 | Designing , Manufacturing , supply including transportation of 2000 KVA DG set, latest CPCB norms approved Prime Power Rating Comprising Diesel engine developing Required BHP, 1500 RPM, 16 Cylinder, Inline/ V type, Water cooled , 4 stroke
Diesel Engine Coupled with 415 Volts, 4 wire, 50Hz, 0.8 PF, 3 Phase Alternator complete with radiator, Battery with Leads ,cables , Residential type Silencer with Expansion bellow SS Flexible Bellows, dia. (300 mm NB), complete with counter flanges, heat resistant gaskets, nuts-bolts-washers etc., complete as required. etc. Alternator of 2000KVA , 415V 50Hz coupled on base frame , with lube oil system , radiator cooled , required batteries , governor , instrumentation , fuel system , engine mounted control panel , utility piping , 415 / 440 volt alternator direct coupled with engine along with static excitation system , AVR panel and all required standard accessories as per specifications mentioned in tender documents. Following accessories included as per specifications mentioned in tender documents required Batteries , /required Qty Lube oil/Residential Silencer Supply & Installation of Acoustic Enclosure suitable for 25 dB incretion loss made of 1.6 mm thick CRCA sheet, 14 tank treatment with 50 to 60 micron powder coating and sound insulation with 100 mm thick Rockwool. Acoustic Enclosure CPCB IV approved with internal lighting , external 990litr tank fuel tank + level switch , level indicator as per specifications mentioned in tender documents Unloading, shifting, of D.G. set as per manufacturers recommendations at ground floor and testing as per protocol and scope of work , with alternator , battery charger , fuel tank , silencer , acoustic enclosure complete set with positioning alignment etc. as per site requirement. For exhaust of Radiator agency has to supply and install the GI Exhaust ducting to through the hot air out from the room required structural and material of GI ducting is in the scope of agency. | 1 | Set | 1,58,99,000 ₹1,58,99,000 Lowest | 1,97,93,090.45 ₹1,97,93,090.45 | 1,68,00,000 ₹1,68,00,000 |
| 3.00 | Fabrication, supply , Installing, Testing & Commissioning of LT extension panel 4pole , 3200A ACB , EDO 50HZ, to be coupled with existing main LT panel ( Having 02 nos 3200A ACB Incomer from 2 x 2000KVA Transformer and 01 Nos 3200A ACB Bus coupler ) Panel to be equipped with R Y B Indication for DG supply available , Ammeter , Voltmeter ,TNC switch , Auto Manual Switch , Emergency stop , all required protections for overload, short circuit, restricted earth fault, lock out relay , earth fault relay , control and inter locking, internal control wiring , 12-window alarm annunciator complete as per scope of works and specifications mentioned in tender documents. | 1 | Each | 13,07,900 ₹13,07,900 | 18,97,500 ₹18,97,500 | 9,00,000 ₹9,00,000 Lowest |
| 4.00 | Fabrication, supply , Installing, Testing & Commissioning of DG panel AMF panel , ( Having 01 nos 3200A EDO type 4 Pole ACB Incomer from DG set and 01 Nos 3200A EDO type 4 Pole ACB as outgoing feeder to Main LT panel ) DG incomer section to be equipped with R Y B Indication , DG ON OFF , ACB ON OFF TRIP Indication , Ammeter , Voltmeter , TNC switch . Line voltage monitor , Auto Manual switch , Emergency Stop , DG engine ON OFF Push Button , DG controller , all required protections for 2000 KVA DG set , MS base channel for panel , relays, timers, set of CTs for metering & protection and MFM meters , KWH, KVARH, KVAH , DG running Hour meter , provision for overload, short circuit, restricted earth fault, under frequency, lock out relay , earth fault relay , control and inter locking, internal control wiring , 12-window alarm annunciator complete as per specifications mentioned in tender documents. | 1 | Each | 15,14,700 ₹15,14,700 | 14,95,000 ₹14,95,000 Lowest | 15,00,000 ₹15,00,000 |
| 5.00 | Fabrication, supply , installation of Alternator terminal Extension Box matching to alternator cable chamber with copper bus bar for termination of LT cables at Alternator side made from 3 mm thick steel sheet. The entire extension box shall be given primer coat after proper treatment and powder coating with 7 tank process before assembly of various items. All the joints shall have proper gaskets. | 1 | Each | 2,53,000 ₹2,53,000 Lowest | 3,45,000 ₹3,45,000 | 3,50,000 ₹3,50,000 |
| 6.00 | SITC of control logic and interlocking between Transformer Incomer No. 1, Transformer Incomer No. 2, Bus Coupler, 2000 kVA DG set incomer and 910 kVA DG set outgoing feeder in the existing Main LT panel, as per tender specifications, including all required wiring and materials. The scope includes necessary modifications in the existing LT panel for interlocking works. Existing ACBs are of GE make. The work also includes supply, installation, and testing of new protection relays (Overload, Short Circuit, Earth Fault, Instantaneous, and Under Voltage) for one transformer incomer feeder, along with all required control wiring. | 1 | set | 1,50,000 ₹1,50,000 Lowest | 4,02,500 ₹4,02,500 | 5,00,000 ₹5,00,000 |
| 7.00 | SITC of RCC Civil foundation work as per OEM recommendation and technical specifications mentioned in tender documents agency has to get approved the CIVIL foundation drawing by engaging the structural engineer , architecture and submit the stability certificate before starting foundation works for DG set The work also includes RCC cable trench MS chequered plate 10 MM duly painted openable type 20 Mtrs * 1 mtr *1mtr ( L X W X D ) cable trench. The work includes excavation of DG foundation area , rock breaking if available during the excavation , existing civil concrete breaking , all the loose soil debris to be taken out from the campus. | 1 | Job | 7,16,000 ₹7,16,000 | 2,01,250 ₹2,01,250 Lowest | 8,00,000 ₹8,00,000 |
| 8.00 | SITC of extension / modification of existing RCC Civil foundation of DG set as per OEM recommendation agency has to get approved the CIVIL foundation drawing by engaging the structural engineer , architecture and submit the stability certificate before starting foundation works for DG set The work also includes RCC cable trench MS chequered plate 10 MM duly painted openable type 5 Mtrs * 1 mtr *1mtr ( L X W X D ) cable trench | 1 | Job | 5,49,000 ₹5,49,000 | 57,500 ₹57,500 Lowest | 5,00,000 ₹5,00,000 |
| 9.00Supply and Erection of Exhaust Piping exhaust stack | ||||||
| 10.0012 Inch / 300 mm pipe or as per OEM | ||||||
Tender Value
₹2.9 Cr
EMD Value
₹5.7 L
Closing Date
19 May 2026, 3:00 pmClosed
Director TMC
Engineering services, Ground Floor, Pushp Building (Old St. Jude Building), ACTREC 410210
Supply Installation testing and commissioning of 1 No 2000 KVA DG set with AMF Panel and LT extension Panel and other accessories for CRI Building at ACTREC Campus
2026_TMC_906227_1
VK/ET-14/2000 KVA DG SET/2026
Open Tender
Electrical Works
Item Rate
210 days
ACTREC, Kharghar
As per ternder terms and conditions
5 documents required · 5 mandatory
₹0
₹5.7 L
ACTREC, Kharghar
10 Aug 2026
22 Apr 2026
20 May 2026
22 Apr 2026
19 May 2026
22 Apr 2026
22 Apr 2026 - 28 Apr 2026
29 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Diesel engineer and alternator | - | - | - | - |
| 2 | Designing , Manufacturing , supply including transportation of 2000 KVA DG set, latest CPCB norms approved Prime Power Rating Comprising Diesel engine developing Required BHP, 1500 RPM, 16 Cylinder, Inline/ V type, Water cooled , 4 stroke
Diesel Engine Coupled with 415 Volts, 4 wire, 50Hz, 0.8 PF, 3 Phase Alternator complete with radiator, Battery with Leads ,cables , Residential type Silencer with Expansion bellow SS Flexible Bellows, dia. (300 mm NB), complete with counter flanges, heat resistant gaskets, nuts-bolts-washers etc., complete as required. etc. Alternator of 2000KVA , 415V 50Hz coupled on base frame , with lube oil system , radiator cooled , required batteries , governor , instrumentation , fuel system , engine mounted control panel , utility piping , 415 / 440 volt alternator direct coupled with engine along with static excitation system , AVR panel and all required standard accessories as per specifications mentioned in tender documents. Following accessories included as per specifications mentioned in tender documents required Batteries , /required Qty Lube oil/Residential Silencer Supply & Installation of Acoustic Enclosure suitable for 25 dB incretion loss made of 1.6 mm thick CRCA sheet, 14 tank treatment with 50 to 60 micron powder coating and sound insulation with 100 mm thick Rockwool. Acoustic Enclosure CPCB IV approved with internal lighting , external 990litr tank fuel tank + level switch , level indicator as per specifications mentioned in tender documents Unloading, shifting, of D.G. set as per manufacturers recommendations at ground floor and testing as per protocol and scope of work , with alternator , battery charger , fuel tank , silencer , acoustic enclosure complete set with positioning alignment etc. as per site requirement. For exhaust of Radiator agency has to supply and install the GI Exhaust ducting to through the hot air out from the room required structural and material of GI ducting is in the scope of agency. | - | Set | - | - |
| 3 | Fabrication, supply , Installing, Testing & Commissioning of LT extension panel 4pole , 3200A ACB , EDO 50HZ, to be coupled with existing main LT panel ( Having 02 nos 3200A ACB Incomer from 2 x 2000KVA Transformer and 01 Nos 3200A ACB Bus coupler ) Panel to be equipped with R Y B Indication for DG supply available , Ammeter , Voltmeter ,TNC switch , Auto Manual Switch , Emergency stop , all required protections for overload, short circuit, restricted earth fault, lock out relay , earth fault relay , control and inter locking, internal control wiring , 12-window alarm annunciator complete as per scope of works and specifications mentioned in tender documents. | - | Each | - | - |
| 4 | Fabrication, supply , Installing, Testing & Commissioning of DG panel AMF panel , ( Having 01 nos 3200A EDO type 4 Pole ACB Incomer from DG set and 01 Nos 3200A EDO type 4 Pole ACB as outgoing feeder to Main LT panel ) DG incomer section to be equipped with R Y B Indication , DG ON OFF , ACB ON OFF TRIP Indication , Ammeter , Voltmeter , TNC switch . Line voltage monitor , Auto Manual switch , Emergency Stop , DG engine ON OFF Push Button , DG controller , all required protections for 2000 KVA DG set , MS base channel for panel , relays, timers, set of CTs for metering & protection and MFM meters , KWH, KVARH, KVAH , DG running Hour meter , provision for overload, short circuit, restricted earth fault, under frequency, lock out relay , earth fault relay , control and inter locking, internal control wiring , 12-window alarm annunciator complete as per specifications mentioned in tender documents. | - | Each | - | - |
| 5 | Fabrication, supply , installation of Alternator terminal Extension Box matching to alternator cable chamber with copper bus bar for termination of LT cables at Alternator side made from 3 mm thick steel sheet. The entire extension box shall be given primer coat after proper treatment and powder coating with 7 tank process before assembly of various items. All the joints shall have proper gaskets. | - | Each | - | - |
| 6 | SITC of control logic and interlocking between Transformer Incomer No. 1, Transformer Incomer No. 2, Bus Coupler, 2000 kVA DG set incomer and 910 kVA DG set outgoing feeder in the existing Main LT panel, as per tender specifications, including all required wiring and materials. The scope includes necessary modifications in the existing LT panel for interlocking works. Existing ACBs are of GE make. The work also includes supply, installation, and testing of new protection relays (Overload, Short Circuit, Earth Fault, Instantaneous, and Under Voltage) for one transformer incomer feeder, along with all required control wiring. | - | set | - | - |
| 7 | SITC of RCC Civil foundation work as per OEM recommendation and technical specifications mentioned in tender documents agency has to get approved the CIVIL foundation drawing by engaging the structural engineer , architecture and submit the stability certificate before starting foundation works for DG set The work also includes RCC cable trench MS chequered plate 10 MM duly painted openable type 20 Mtrs * 1 mtr *1mtr ( L X W X D ) cable trench. The work includes excavation of DG foundation area , rock breaking if available during the excavation , existing civil concrete breaking , all the loose soil debris to be taken out from the campus. | - | Job | - | - |
| 8 | SITC of extension / modification of existing RCC Civil foundation of DG set as per OEM recommendation agency has to get approved the CIVIL foundation drawing by engaging the structural engineer , architecture and submit the stability certificate before starting foundation works for DG set The work also includes RCC cable trench MS chequered plate 10 MM duly painted openable type 5 Mtrs * 1 mtr *1mtr ( L X W X D ) cable trench | - | Job | - | - |
| 9 | Supply and Erection of Exhaust Piping exhaust stack | - | - | - | - |
| 10 | 12 Inch / 300 mm pipe or as per OEM | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.88 MB
TD.pdf
Tender Documents • 2.69 MB
BOQ_952541.xls
BOQ • 0.33 MB
AnnexureForm.xls
Additional Documents • 0.12 MB
Corrigendum.pdf
PDF • 0.41 MB
Corrigendum.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].