| 1 | L1₹1.4 CrAccepted-AOC 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹1.4 Cr | L1 | Accepted-AOC Being the lowest and reasonable bidder |
| 2 | L2₹1.4 Cr+₹1.7 L (1.25%)Rejected-AOC | ₹1.4 Cr+₹1.7 L (1.25%) | L2 | Rejected-AOC Being the other than lowest bidder |
| 3 | L3₹1.4 Cr+₹5.6 L (4.08%)Rejected-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹1.4 Cr+₹5.6 L (4.08%) | L3 | Rejected-AOC Being the other than lowest bidder |
| 4 | L4₹1.4 Cr+₹7.4 L (5.42%)Rejected-AOC | ₹1.4 Cr+₹7.4 L (5.42%) | L4 | Rejected-AOC Being the other than lowest bidder |
| 5 | L5₹1.5 Cr+₹12.6 L (9.16%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.5 Cr+₹12.6 L (9.16%) | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
8 Jul 2023, 6:00 pmClosed
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
PROVISION OF ENERGY SAVING MEASURES BY SMART SWITCHING SYSTEM AT NAGROTA MIL STN UNDER GE NAGROTA
2023_MES_600509_1
CWE/NGT-15/2023-24
Open Tender
Civil Works
Item Rate
1005 days
Nagrota
As per NIT and tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE Nagrota
₹2.2 L
Yes
31 Jul 2023
3 Jun 2023
15 Jul 2023
3 Jun 2023
8 Jul 2023
24 Jun 2023
3 Jun 2023 - 10 Jun 2023
Amount
Supply, Installation, Testing and Commissioning of PLC (ProgrammableLogic Controller) with Retandant System Panel floor mounted indoor,Transmitter panel to automatically control the rawwater / UGSR with ultrasonic sensor to set ON/Off Condition via Data retrieved automatic controlling of Pumps & fully motorize Valve to operate the water Supply system & act as a user controlled with Visual Annunciation panel & with wire (Optical Fibre)Transmitter /receiver of complete water supply operation Controlled network.The Panel shall be Floor mounting as per 61439 part 1&2 TTA Shall be of suitable size made of 2/1.6 mm CRCA sheet Properly powder coated ,consisting of following features:-type made up of 2mm CRCA sheet on channel base frame, including Electrical & mechinacal Interlocking ,Auto to Manual Change over operation in case of PLC faliur,DG , load Sharing for two No DG along with priority setting, LT panel with appropriate size Indoor type panel factory made, weather proof , dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , of make dvepl or equivalent make
tricolitre, schneider as specified and directed by Engr-in-Charge The firms specified cannot authorize any other vendors to manufacture Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only(dvepl,tricolte,adlac) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required and comprising of the following :- Including Having following Feature & including Following Switchgear.
HMI for DG / Main Setting Panel, 10 inch: Multi-panel for operating and monitoring DGs,use as thin client for terminal services, remote maintenance and services via the Internet / Intranet, OPC interfacing to different manufacturers, display of HTML documents, with pixel-graphics 10.4" TFT- touch display with background lighting, 65536 colors, resolution 640x 480 pixels, MTBF 50000 h, Windows CE operating system, ARM CPU, mouse andcurve functions and bar display, calculation functions, external evaluations with Excel and MS Access, input/output fields, configurable buttons with 16 functions simultaneously, online evaluation using characteristics, Visual Basic Scripting, signalling system with different alarm/message classes, message buffer for 512 entries, 500 process images, 50 archives per project, 10000 entries per archive,recipe memory for 300 recipes,10 user groups can be set, password protection, 16 online languages, multimedia card data carrier support, time interrupt function for cyclic function processing,display of graphics, bars, predefined texts, buttons. Integrated signalling system with 4000 messages, remote download for configuring USB, MPI, Profibus DP, Ethernet, Modem, http and SD/Multi Media Card, degree of protection IP65 on the front, according to IEC 60068-x, IEC 6199-4-x, IEC 61131-2, including operating instructions, Compact Flash card, back-up battery; supply and mount ready-to-operate. :- 1 No Make ( Schneider / L&T/ ABB)
PLC CPU, Best Performance, ext.Memory, PN, DP:- Central processing unit for the low and medium performance range of the central and decentralized control, programming by means of FBD, LAD, STL in accordance with IEC 61131-5, SCL, CFC, processing times (bin.) 0.05 μs and (floating point arithmetic) 0.45 μs, 256 counters, 384 kB RAM, data blocks 1024, address range 2 kB, 16.384 digital inputs and outputs and 1024 analog inputs and outputs can be parameterized, can be expanded to up to three module racks, operating hours counter, process diagnosticsmessages, start-up function, control of variables, diagnostics buffer with up to 500 entries, routing function, interfaces MPI and DP master, buffering by means of MMC, Profinet CBA communication, hardware clock (real time), CE, UL, CUL, CSA and C-Tick certification, approvals according to EN 55011, EN 60079-15, EN 61000-6-2/ -4, IEC 60068-2-6/ -27/ -29, IEC 60721-3-2/ -3, IEC 61000-4-2/ -3/ -4/ -5/ -6, mm, including sectional rail for mounting modules as required and Micro Memory Card 2 MB, supply and mount ready-tooperate. :- 1 No Make ( Schneider / L&T/ ABB)
LM Device : The LM Module should be a single Module having following features inbuilt without use of any external hardware: • Load Sharing • On Boar Outputs for Load Shedding (For some most Critical Loads, rest could be through PLC interlocking) • Reverse Power Monitoring/Protection • Short Circuit Monitoring/Protection • Over Current Monitoring/Protection • Under/Over Voltage Monitoring • Under/Over Frequency Monitoring • Profibus Communication On Board for Communicating with PLC. • Stand Alone operation; will work without any PLC support (in critical Condition). • Redundant Power Supply for reduced down time • Integrated Buttons to Raise/Lower Frequency Power supply module for compact I/O device, flat design, for snapping onto DIN rail, input voltage 85 – 132 V AC and 170 – 264 V AC, 47/63 Hz,output voltage 24 V DC stabilized and floating, settable output voltage 22 – 29 V DC, residual ripple less than 150 mVpp, status display, soft start function, output current 10 A, integrated fuse, electronic short-circuit protection, electrical isolation primary/secondary, CE certificate, degree of protection IP 20, CE, UL, CSA certification, approvals according to EN 55022, EN50081-1, EN 50178, EN 61000-4-1, EN 61000-6-2, EN 60950, EN 61440, EN 60947-1, IEC 529, IEC 536, ambient temperature 0 – 60°C, mounting bracket; supply, mount ready to operate. :- 1No Make ( Schneider / L&T/ ABB)
Supply,Installation,Commissioning and testing of high torque motorized valve with gears and adopters self lubricating type,Weather proof with protection against,Over voltage jamming of valve and over current protection with manual by pass arrangement to Open/Close the valve on power failure including taking down complete. Make:- Sasa/Leader/Kirloskar / Rotrak
Valve Size 200MM bore Designed line pressure 4 kg/sq cm Operating angle - 90 degree Disc material - CI with nylon coating Valve type -Butter fly valve PN-10 with geared motor on top With SCADA out put POT With anti theft device micro controller based With Torque 35 Nm running time 13s With close off presure 1200 kpa With operating voltage 230 Vac with 2 in built auxiliary switch, IP 67
Supply,Installation,Commissioning and testing of high torque motorized valve with gears and adopters self lubricating type,Weather proof with protection against,Over voltage jamming of valve and over current protection with manual by pass arrangement to Open/Close the valve on power failure including taking down complete. Make:- Sasa/Leader/Kirloskar / Rotrak
Valve Size 150MM bore Designed line pressure 4 kg/sq cm Operating angle - 90 degree Disc material - CI with nylon coating Valve type -Butter fly valve PN-10 with geared motor on top With SCADA out put POT With anti theft device micro controller based With Torque 35 Nm running time 13s With close off presure 1200 kpa With operating voltage 230 Vac with 2 in built auxiliary switch, IP 67
Supply,Installation,Commissioning and testing of high torque motorized valve with gears and adopters self lubricating type,Weather proof with protection against,Over voltage jamming of valve and over current protection with manual by pass arrangement to Open/Close the valve on power failure including taking down complete. Make:- Sasa/Leader/Kirloskar / Rotrak
Valve Size 50MM bore Designed line pressure 4 kg/sq cm Operating angle - 90 degree Operating angle - 90 degree Disc material - CI with nylon coating Valve type -Solenoid valve PN-10 with geared motor on top With SCADA out put POT With anti theft device micro controller based With Torque 35 Nm running time 13s With close off presure 1200 kpa With operating voltage 230 Vac with 2 in built auxiliary switch, IP 67
Supplying , laying and testing of XLPE Insulated Cable 4 core -2.5 Sqmm armoured cable 1100v grade with stranded copper conductor complete all as specified
Supplying , laying and testing of XLPE Insulated Cable 7 core - 2.5 Sqmm armoured cable 1100v grade with stranded Copper conductor
Supply , installing, testing of LT internally arc tested indoor type- Panel should have internally arc tested with neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powder coated paint, 415 volts Panel Make-dvepl, tricolite,aspl, TPN, 50 Hz both sides properly welded MS angular supported with chanel frame of size 50mm , at all vertical comers grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected compprising of following accessories. Make of Panel :- Siemens-Sivacon/ Legrand/ L&T -Enersys-I/ Schneider-Blokset . Note :- Panel should be TTA in accordance with IEC 61439 part I & II and all panel will be manufactured by OEM or their system. The authorised vendor also approved in MES. Incoming ACB 4 Pole, 415 V, with Thermal Magnetic Release of capacity, 1000 amps, breaking cap 50 KA at 415 volts = 01 Nos Make :-L&T/legrand/Schneider
ATS(Automatic transfer switch) 1000A Four Pole,Battery charger, complete with transformer/rectifier,Smart Motor Controller Protection Having Feature as Protection against UV,OV, Phase loss,Phase unblanced , Phase Asymetery & Auto Phase Polarity Correction with Time Delay & Having Display of V, I ,Pf, Hz 1No Make :-L&T/legrand/Schneider
Bus Bars : 1000A TPN + E aluminium busbars suitable for 50 KA for 1 Sec. Outgoing . ACB 4 Pole, 415 V, with Thermal Magnetic Release of capacity, 800 amps, breaking cap 50 KA at 415 volts = 01 Nos Make :-L&T/legrand/Schneider MCCB 4 Pole, 415 V, with Thermal Magnetic Release with Standard Extended Rotary Handle, Spreaders, Phase Barrier of capacity, 630 amps, breaking cap 50 KA at 415 volts = 02 Nos Make :-L&T/legrand/Schneider MCCB 200 Amp 4P 36KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No Make :-L&T/legrand/Schneider MCCB 100 Amp 4P 36KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No Make :-L&T/legrand/Schneider MCCB 63 Amp 4P 25KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No Make :-L&T/legrand/Schneider MCB 6-32 Amp DP 10KA -2No Make :-L&T/legrand/Schneider MCB 6-32 Amp FP 10KA - 2No Make :-L&T/legrand/Schneider MCB 6-32 Amp TP 10KA - 2No Make :-L&T/legrand/Schneider
Volt meter 0 to 500 volts digital type with slector switch = 1 No. Ampere meter 0 to 1000 Amp digital type slector - 1 No. Phase indicator lamp - Set of three. All connections from MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of aluminium strip thimble lugs cost of which included in the quoted rate of item. All acessories prewired with copper conductor cable single strand PVC insulated with copper thimbe lugs etc all as specified and directed Above all complete in all respect including installation of panel including supply and installation of frame pedestal 450 mm high above ground level and 450mm grouted in PCC below ground level.
Supply , installing, testing of LT internally arc tested indoor type- Panel should have internally arc testedwith neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 3.15 mm thick CRCA sheet duly powder coated paint, 415 volts Panel Make-dvepl, tricolite,aspl, both sides properly welded MS angular supported with chanel frame of size 50mm , at all vertical comers grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected compprising of following accessories. Make of Panel :- Siemens-Sivacon/ Legrand/ L&T -Enersys-I/ Schneider-Blokset Note :- Panel should be TTA in accordance with IEC 61439 part I & II and all panel will be manufactured by OEM or their system. The authorised vendor also approved in MES. Incoming ACB 4 Pole, 415 V, with Thermal Magnetic Release of capacity, 800 amps, breaking cap 50 KA at 415 volts = 01 Nos Make :-L&T/legrand/Schneider
Outgoing MCCB TP NL LT 415 volt 50 Hz, AC 250 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 4 No Make :-L&T/legrand/Schneider
Soft Starter 100 H.P. Built-in bypass contactor, relays, CT/PT, timers, - 04 Nos. Make-L&T/ABB Semi-Conductor Fuse,- 12 No , ON, OFF , Trip Indicating Light - 15 No Push Buttons - 8 No Digital MFM with CT, Control Fuse etc fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 05 Nos.Make-L&T/ABB
Supply , installing, testing of LT internally arc tested indoor type- Panel should have internally arc tested with neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powder coated paint, 415 volts Panel Make-dvepl, tricolite,aspl, TPN, 50 Hz both sides properly welded MS angular supported with chanel frame of size 50mm , at all vertical comers grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected compprising of following accessories. Make of Panel :- Siemens-Sivacon/ Legrand/ L&T -Enersys-I/ Schneider-Blokset Note :- Panel should be TTA in accordance with IEC 61439 part I & II and all panel will be manufactured by OEM or their system. The authorised vendor also approved in MES. Incoming MCCB TP NL LT 415 volt 50 Hz, AC 630 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No Make :-L&T/legrand/Schneider
Outgoing MCCB TP NL LT 415 volt 50 Hz, AC 320 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 2 No Make :-L&T/legrand/Schneider
Soft Starter 150 H.P. Built-in bypass contactor, relays, CT/PT, timers, - 02 Nos. Make-L&T/ABB Semi-Conductor Fuse,- 6 No ON, OFF , Trip Indicating Light - 6 No Push Buttons - 4 No Digital MFM with CT, Control Fuse etc fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 03 Nos.Make-L&T/ABB
MCCB 200 Amp 4P 36KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No Make :-L&T/legrand/Schneider MCCB 100 Amp 4P 36KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No Make :-L&T/legrand/Schneider MCCB 63 Amp 4P 25KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No Make :-L&T/legrand/Schneider MCB 6-32 Amp DP 10KA -2No Make :-L&T/legrand/Schneider MCB 6-32 Amp FP 10KA - 2No Make :-L&T/legrand/Schneider MCB 6-32 Amp TP 10KA - 2No Make :-L&T/legrand/Schneider
ATS(Automatic transfer switch) 800A Four Pole,Battery charger, complete with transformer/rectifier,Smart Motor Controller Protection Having Feature as Protection against UV,OV, Phase loss,Phase unblanced , Phase Asymetery & Auto Phase Polarity Correction with Time Delay & Having Display of V, I ,Pf, Hz- 1No Make :-L&T/legrand/Schneider
Bus Bars : 800A TPN + E aluminium busbars suitable for 50 KA for 1 Sec. Outgoing . MCCB 4 Pole, 415 V, with Thermal Magnetic Release with Standard Extended Rotary Handle, Spreaders, Phase Barrier of capacity, 630 amps, breaking cap 50 KA at 415 volts = 02 Nos MCCB 200 Amp 4P 36KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No MCCB 100 Amp 4P 36KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No MCCB 63 Amp 4P 25KA MCCB adjustable thermal setting with Standard Extended Rotary Handle, Spreaders, Phase Barrier- 1No MCB 6-32 Amp DP 10KA -2No MCB 6-32 Amp FP 10KA - 2No MCB 6-32 Amp TP 10KA - 2No
Volt meter 0 to 500 volts digital type with slector switch = 1 No. Ampere meter 0 to 1000 Amp digital type slector - 1 No. Phase indicator lamp - Set of three. All connections from MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of aluminium strip thimble lugs cost of which included in the quoted rate of item. All acessories prewired with copper conductor cable single strand PVC insulated with copper thimbe lugs etc all as specified and directed Above all complete in all respect including installation of panel including supply and installation of frame pedestal 450 mm high above ground level and 450mm grouted in PCC below ground level.
Supply , installing, testing of LT internally arc tested indoor type- Panel should have internally arc tested with neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powder coated paint, 415 volts Panel Make-dvepl, tricolite,aspl, TPN, 50 Hz both sides properly welded MS angular supported with chanel frame of size 50mm , at all vertical comers grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected compprising of following accessories. Make of Panel :- Siemens-Sivacon/ Legrand/ L&T -Enersys-I/ Schneider-Blokset Note :- Panel should be TTA in accordance with IEC 61439 part I & II and all panel will be manufactured by OEM or their system. The authorised vendor also approved in MES. Incoming MCCB TP NL LT 415 volt 50 Hz, AC 630 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No Make :-L&T/legrand/Schneider
Outgoing MCCB TP NL LT 415 volt 50 Hz, AC 250 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 3 No Make :-L&T/legrand/Schneider
Soft Starter 100 H.P. Built-in bypass contactor, relays, CT/PT, timers, - 03 Nos. Make-L&T/ABB Semi-Conductor Fuse,- 9 No ON, OFF , Trip Indicating Light - 9 No Push Button - 6 No Digital MFM with CT, Control Fuse etc fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 04 Nos.Make-L&T/ABB
Supply , installing, testing of LT internally arc tested indoor type- Panel should have internally arc tested with neoprene rubber gasket and locking arrangement vermin/ dust/ weather proof, self ventilation with wire mesh at suitable interval on both side, totally enclosed bus bar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2 mm thick CRCA sheet duly powder coated paint, 415 volts Panel Make-dvepl, tricolite,aspl, TPN, 50 Hz both sides properly welded MS angular supported with chanel frame of size 50mm , at all vertical comers grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and connecting the incoming/ out going feeders by providing cable glands and cable lugs complete all as specified and didrected compprising of following accessories. Make of Panel :- Siemens-Sivacon/ Legrand/ L&T -Enersys-I/ Schneider-Blokset Note :- Panel should be TTA in accordance with IEC 61439 part I & II and all panel will be manufactured by OEM or their system. The authorised vendor also approved in MES. Incoming MCCB TP NL LT 415 volt 50 Hz, AC 630 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No Make :-L&T/legrand/Schneider
Outgoing MCCB TP NL LT 415 volt 50 Hz, AC 250 Amps 36 KA with adjustable thermal setting With on/off/trip indicator.and Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 2 No Make :-L&T/legrand/Schneider
Soft Starter 100 H.P. Built-in bypass contactor, relays, CT/PT, timers, - 02 Nos. Make-L&T/ABB Semi-Conductor Fuse,- 6 No ON, OFF , Trip Indicating Light - 6 No Push Button - 4 No Digital MFM with CT, Control Fuse etc fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 03 Nos.Make-L&T/ABB
Supply,Installation,Commissioning and testing of Ultra Sonic non contact for level monitoring for over head tank Make:- Schneider / Siemens/ABB/SASA and consisting of following of features:-
Principal:-Ultra sonic sound waves water level sensing O/P Pot 4-20 ma/0-20v Data transmitting output port iot operation output port Range 8.00 - 10.00 metres depth Corrosion free Plastic body with pipe fitting.
Supply, installation, testing and commissioning of step down transformer 11KV/433 Volts, 3 phase 50 Hz 500 KVA outdoor type, with off load tap changing arrangement on HT Side to vary secondary voltage upto 7.5% in step (+ or -) 2.5% including suitable cable entry boxes both on HT to receive 95 Sqmm 3 core XLPE cable and on low voltage side to accommodate XLPE cable of suitable size complete in all respect with standard accessories and fitment confirming to IS : 1180 2014 with amendment 1,2&3. Primary side Delta and Secondary side Star. The sailent feature of transformer shall be as follows :- (a) Transformer shall be oil immersed, naturally self cooled copper wound, winding core type MS radiator cooled tank complete with first filling of transformer oil plus 5% spare oil as per IS : 335 to 1980 ISI marked filtered & dehydrated & other standard fittings / Accessories and 7 position of circuit Tap changer (Tapping Range + or - 7.5% in step of 2.5% Each) with vector group Dyn-11 cooling system. The temperature of oil shall not rise more than 50 degree centrigrade to amient temp and 55 degree centrigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS : 632. (b) Trasformer shall be provided with the following :- (i) Rating and diagram plate. (ii) Earthing terminals 2 Nos. (iii) Lifting lugs. (iv) Thermometer pocket. (v) Air release hole with plug. (vi) Tap changer with locking provision. (vii) Oil temperature indicator. (viii) Plateform of size 2.5x2.5x2 mtr complete. (ix) XPM Fencing around the platform. Make:- Schneider/Siemens/Jaybee/ABB or equivalent
Supply, installation, testing and commissioning of Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 500 KVA
Supply, Laying, jointing and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armored electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade and cross section area 95 sqmm 3 core conforming to latest IS and ISI marked laid in trenches complete all as directed by EIC.
Supply and fix Cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 Sqmm 3 Core.
Supply, Laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of size 240 Sqmm, 3.5 core, complete all as specified and directed.
Excavating in trenches,in any type of soil, n exe 1.5 m wide and not exceeding 1.5 m in depth and getting out complete all as specified and directed. Note :-Due care will be given while deciding pipeline route for excavation,however any damages to singnal/BSNL/MES HT/LT cables/existing pipes (water/sewage)/existing drain/road etc.while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable & 15 cm of sand after laying the cable, complete all as specified and directed by Engineer-in-charge.
M&L for Bricks well burnt sub class 'B' (old patter) laid flat for cable protection width equal to the length of brick, complete all as specified and directed by Engr-in-Charge
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mmx180mmx40mm
Earthing complete with galvanized iron earth plate electrode 600x600x6 mm thick buried directly in ground vertically with its top edge not less than 2.25 m below ground level. The earth plate shall be covered with 300 mm thick mixture charcoal dust and salt all around below and top. The earth plate shall be covered to GI Strip 32x6 mm thick GI bolt nuts and washers strip shall be taken into and incl test point including 40mm dia light grade pipe galvanized 3m long and 30 cm perforated at bottom and plugged with GI tubing at top complete all as per electrical plate No 3 of SSR Part I as directed. The rate includes for all earth works in any type of soil GI strips up to test point charcoal dust soft watering pipe funnel complete and testing of completion, all as specified and directed.
Outsourcing of services during 24 Hours all days ( including sunday and holidays ) for Maintenance and servicing of all entire system at Dug Well No 8 and Long turn water supply installation including skilled and unskilled manpower from the next day after completion upto defect liability period complete all as specified and directed by Engr-in-Charge.
Scope of work is as under :-(a) The contractor shall employ skilled technician and unskilled man power for maintaining the plants for checking of electrical parameters of the installed plant, recording of all electrical parameters viz Voltage, Current , Energy generation, SCADA Parameters on daily basis and also services indcluding Cleaning and maintenance Weekly and other related work as required on site as specified. (b) In case, the contractor fails to provide manpower like technician, services at mentioned above within 12 hours and any delay thereafter, recovery of Rs 500.00 per day shall be deducted from the dues of contractor by the department without any notice.
Note:- Schedule of credit of Rs. 88,750.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S BHATIA BUILDERS AND CONTRACTORS
MOHAN LAL AND SONS
PROACH ASSOCIATES BUILDERS & ENGINEERS
kailu construction co
M/s V6 Infrastructures Pvt. Ltd.
Sant Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .