GE (AF) PALAM DELHI CANTT 10
GE (AF) PALAM DELHI CANTT 10
REPAIR / MAINT OF FIRE FIGHTING SYSTEM, FIRE ALARM AND FIRE DETECTION SYSTEM ALONGWITH CONNECTED WORKS UNDER GE (AF) PALAM, DELHI CANTT-10
2026_MES_794490_1
8026/A/T-71/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) PALAM DELHI CANTT 10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹59,900
Yes
16 Oct 2026
16 Oct 2026
13 Nov 2026
16 Oct 2026
6 Nov 2026
30 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive monthly maintenance of auto fire alarm system installed in BBJ Hanger & RSS Hangar and ISH in Tech Area at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 Nos.
(b) UL Listed intelligent addressable multi-criteria detector with base- 284 Nos.
(c) UL Listed intelligent heat detector - 08 Nos.
(d) Manual call point - 08 Nos.
(e) Control module for hooter - 18 Nos.
(f) zone Monitor module - 28 Nos.
(g) Fault isolator - 12 Nos.
(h) Wall mounted hooter - 18 Nos.
(j) Response indicator - 25 Nos.
(k) IR Flame detector - 28 Nos.
(l) UPS 1 KVA - 02 No. | 11 | Each Month | - | - |
| 2 | Comprehensive monthly maintenance of auto fire alarm system installed in AW 101 Hanger No -I, II & III in Tech Area at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 192 Nos.
(c) UL Listed intelligent heat detector - 02 Nos.
(d) Manual call point - 18 Nos.
(e) Control module hooter - 05 Nos.
(f) Monitor module - 06 Nos.
(g) Fault isolator - 12 Nos.
(h) Wall mounted hooter - 06 Nos.
(j) Response indicator - 70 Nos.
(k) IR Flame detector - 44 Nos.
(l) UPS 1 KVA - 02 Nos. | 11 | Each Month | - | - |
| 3 | Comprehensive monthly maintenance of auto fire alarm system installed in SES LAB OF 181 FLIGHT, TWIN DSS BLDGS & CARGO TERMINAL in Tech Area at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Material required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 59 Nos.
(c) Manual call point - 05 Nos.
(d) Control module for hooter - 05 Nos.
(e) Fault isolator - 04 Nos.
(f) Wall mounted hooter - 07 Nos.
(g) Response indicator - 07 Nos. | 11 | Each Month | - | - |
| 4 | Comprehensive monthly maintenance of auto fire alarm system installed in SIGNAL EXCHANGE BLDG IN Camp area & EDN SECTION in Camp Area at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 99 Nos.
(c) UL listed intelligent heat detector-02 Nos
(d) Manual call point - 08 Nos.
(e) Control module for hooter - 08 Nos.
(f) Monitor module- 09 Nos
(g) Fault isolator - 06 Nos.
(h) Wall mounted hooter - 08 Nos.
(j) Response indicator - 48 Nos. | 11 | Each Month | - | - |
| 5 | Comprehensive monthly maintenance of auto fire alarm system installed in 41 SQN Simulator Bldg in Tech Area at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 130 Nos.
(c) UL Listed intelligent heat detector - 04 Nos.
(d) Manual call point - 11 Nos.
(e) Control module for hooter - 06 Nos.
(f) Monitor module - 05 Nos.
(g) Fault isolator - 12 Nos.
(h) Wall mounted hooter - 20 Nos.
(j) Response indicator - 48 Nos.
(k) UPS 1 KVA -02 Nos. | 11 | Each Month | - | - |
| 6 | Comprehensive monthly maintenance of auto fire alarm system installed in AFCNWP CAMP AREA at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 01 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 65 Nos.
(c) UL Listed intelligent heat detector - 06 Nos.
(d) Manual call point - 06 Nos.
(e) Control module for hooter - 06 Nos.
(f) Monitor module - 06 Nos.
(g) Fault isolator - 06 Nos.
(h) Wall mounted hooter - 06 Nos.
(j) Response indicator - 13 Nos. | 11 | Each Month | - | - |
| 7 | Comprehensive monthly maintenance of auto fire alarm system installed in SES SCTION OF CPRU, IT SEC, CFNL LAB IN TECH AREA at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basisof all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 03 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 162 Nos.
(c ) UL listed intelligent heat detector - 02 Nos
(d) Manual call point - 14 Nos.
(e) Control module for Manual call point - 14 Nos.
(f) monitor module - 06 Nos.
(g) Fault isolator - 10 Nos.
(h) Wall mounted hooter - 14 Nos
(j) Response indicator - 72 Nos.
(k) sounder relay - 08 Nos.
(l) UPS 1 KVA - 03 Nos.
(m) central control including 21" colour monitor 21"and its CPU , Key board ,mouse & UPS -01 Set
(n) Repeater panel -01 No | 11 | Each Month | - | - |
| 8 | Comprehensive monthly maintenance of auto fire alarm system installed in ISR LAB, (T), 73 RMU(T), WEATHER BUILDING (C), BBJMCF(T) IN TECH AREA at AF Stn Palam. The detail scope of work consists of the following:-
(i) Cleaning inspecting, checking and repairing on monthly basis of all the equipments of fire detection system.
(ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge.
(iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge.
(iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep.
(v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost.
(vi) Materials required for replacement will be measured and paid separately under respective items of this schedule.
Note:- The detail of fire equipments required repairs/maintenance are as under:-
(a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 03 No.
(b) UL Listed intelligent addressable multi-criteria detector with base- 102 Nos.
(c) Manual call point - 14 Nos.
(d) Control module for Manual call point - 20 Nos.
(e) monitor module - 06 Nos.
(f) Wall mounted hooter - 4 Nos
(g) sounder relay - 4 Nos.
(h) UPS 1 KVA - 04 Nos. | 11 | Each Month | - | - |
| 9 | Supply, installation, testing and commissioning in replacement of Photo electronic type smoke cum heat detector IP67 rated, having removable high performance chamber with twin fire LED's allow 360 degree veiwing, lock mechanism (sensor to base), employ two heat sensing elements with different thermal characteristics to provide a rate of rise dependent response. Electronically addressed, approved by LPCB. Flat FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM). (EN-54 approved) conforming to IS-11360 -1985 having dual ionized chamber meant for easy detection of high carbonized fumes by means of light emitting principle complete with base, UL FM LPCB complete all as specified and as directed by Engineer in charge. Make: Ceasefire/siemens/honeybell/Dyagni | 200 | Each | - | - |
| 10 | Supply only in replacement of addressable manual call point/pull station single action type with gold plated SPST contacts complete all as specified and directed by Engineer in Charge. Make:- Siemens./Honeywell/ceasefire/Agnidy/Notefire | 30 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
tender71.pdf
Tender Documents • 0.67 MB
BOQ_891057.xls
BOQ • 1.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .