Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.1 L+₹37,960 (1.06%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹36.8 L+₹1.1 L (3.04%)Rejected-Finance 1622 KASTA DANGA ROAD KOLKATA 700061 WB | KOLKATA | WEST BENGAL | 700061 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹39.8 L+₹4.0 L (11.3%)Rejected-Finance B 20 H 1 PANCHANANTALLA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹39.9 L+₹4.2 L (11.8%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
21 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8023/B/E8
2021_MES_496343_1
GE/ALP (8023B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
210 days
GE ALIPORE KOLKATA
Class D and Category b (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹64,000
Yes
3 Feb 2022
21 Dec 2021
22 Jan 2022
21 Dec 2021
21 Jan 2022
14 Jan 2022
60 days
Amount
Supply & fabrication of LT Meter Board CPRI approved cubical type of size 1600mm x 1200mm x 400mm to accommodate accessories such as incomer MCCB, outgoing MCB SPN and energy meter 13 Nos made out of 2 mm thick sheet steel indoor type with IP 54 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged only having front openable shutters with locking arrangement in front and PVC sleeved Aluminium bus bar of 300 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning including taking down the old meter boxes of any type and dismantling and refixing of energy meters complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work). (a) MCCB Adjustable thermal magnetic type 4 Pole 250 Amps 35 KA -01 No. (as Incoming) (b) MCB 40-63A SPN, 10KA -13 Nos. Note : The quoted rate shall be deemed to be included the dismantling carefully and refixing the existing energy meters 13 Nos and their necessary connections
Supply and fixing air termination single pointed aluminium rod 12mm dia and 300mm long, on top of the aluminium block , fixed on GI tubing / base plate complete all as specified and directed.
Supply and fixing as in replacement aluminum strip 25mm x 3 mm fixed on wall of multi storied Bldgs complete all as specified and as directed.
Material and labour for earthing complete with GI steel earth plate electrode , 60cm x 60cm x6 mm thick , buried directly in ground (earth plate not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 connected to earthing test point all as specified and including pit PCC (1:3:6), type C-1 in cement concrete & 40 mm thick precast RCC cover in (1:2:4) type B-1 reinforced with 8 mm dia TMT bar @ 75 mm c/c both ways with 02 Nos lifting handles of 12 mm dia MS plain bar, GI pipe 20 mm dia light grade with funnels and wire mesh for watering and 40 mm dia light grade GI pipe for earth lead protection, including earth work etc complete all as specified and as directed.
Supply and laying 40mm bore galvanised iron pipe, "light grade" for protection of GI strip complete all as specified and as directed.
M & L for test point terminal block made out of gun metal or phosphorus bronzed size 75x75x25mm, drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screw all as specified and directed.
M & L for 50mm bore GI pipe "light grade", 4.2 mtr long duly threaded on both side for fixing GI socket & making necessary arragement for holding of air termination rod all as specified & directed.
Material and labour for cement concrete (1:3:6), type C-2 (using 40mm graded stone aggregate) of size 400mmx400mmx400mm for fixing the GI pipe in vertical position over the roof complete all as specified and directed.
Supply and fixing sub main wiring with PVC insulated & unsheatheed two runs of 10 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 10 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade connected to common earth dolly as earth continuity conductor, drawn through in and including PVC casing caping including taking down old existing one complete all as specified and as directed. Note :- Three runs of 10 Sqmm cable and one run PVC casing caping shall be measured as one length.
S&F for TPN DB vertical type 04 way concealed/ mounted on wall, having provision of mounting incomer MCCB 4 Pole 160 Amp 25 KA and outgoing MCB SP including taking down old unserviceable one, blanking plates including making good disturbed surfaces complete all as directed. Make : Standard /C&S / Legrand.
Supply and fixing for MCCB 160 Amp, 4 Pole, 25KA complete all as specified and directed.
Supply and fixing for MCB, SP, 40 Amps complete all as specified and directed.
Hindustan Traders
NICE INFOTECH
RAY STANDARD ENGG CO.
ELECTRO FREEZE
DK Contractor
RST ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .