Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-Finance AT TITIA P O P S KHUNTA DIST MAYURBHANJ 757019 | MAYURBHANJ | ODISHA | 757019 | ₹2.7 Cr | L1 | Accepted-Finance Winner through transparent lottery. |
| 2 | L2₹2.7 CrRejected-Finance WARD NO 14 BARIPADA TOWN DIST MAYURBHANJ ODISHA 757001 | BARIPADA | MAYURBHANJ | ODISHA | 757001 | ₹2.7 Cr | L2 | Rejected-Finance Loss the lottery. |
| 3 | L2₹2.7 CrRejected-Finance | ₹2.7 Cr | L2 | Rejected-Finance Loss the lottery. |
| 4 | L2₹2.7 CrRejected-Finance AT ANDOLA P O SRIDHARPUR PS JAJPUR TOWN DIST JAJPUR ODISHA 755062 | JAJAPUR | ODISHA | 755062 | ₹2.7 Cr | L2 | Rejected-Finance Loss the lottery. |
| 5 | Rejected-Technical NEAR KIIT CAMPUS WARD NO 01 PO KIIT PS INFOSITY BHUBANESWAR PIN 751024 | BHUBANESWAR | KHORDHA | ODISHA | 751024 | - | - | Rejected-Technical As per DTCN |
Tender Value
₹3.1 Cr
EMD Value
₹3.1 L
Closing Date
13 Jan 2026, 5:00 pmClosed
CCE, Eastern (R and B) Circle, Balasore
O/o CCE, Eastern (R and B) Circle, Balasore
Building Work
2025_EICCL_123997_1
CCEEC-14/2025-26
National Competitive Bid
Civil Works - Buildings
180 days
Mayurbhanj
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹3.1 L
Yes
30 Apr 2026
30 Dec 2025
15 Jan 2026
30 Dec 2025
13 Jan 2026
30 Dec 2025
30 Dec 2025 - 13 Jan 2026
CIVIL PORTION WORK:-Earth work in excavation of foundation in all kinds of soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth etc. complete as per the direction of the Engineer-in-charge.
Filling foundation & Plinth with excavated materials well watered & rammed etc. complete as per the Specification and direction of the Engineer-in-charge.
Supplying, filling in foundation & plinth with sand in layers including watering and ramming with cost conveyance, royalities, taxes of all materials and labour with T&P required for the work etc. complete as per the Specification and direction of the Engineer-in-charge.
Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size black broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete as per Specification & Direction of the Engineer-in-charge.
Providing, lifting, hoisting and laying Reinforoad Comer Concrsis of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair Case, jali , shelves and slab etc as per approved designs and drawings having a minimum Compressive strength ( in work test) 20N. / Square mm. in 15cm. cubes at 28 days after mixing and test conducted in accordance with 1.S. 456 and 1.S. 516 using screened & washed sharp Hiver sand far mertar and 18mm. to 20 mm. size black hand crusher broken granite stone chips of Spproved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement Including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days including, centering and shuttering then after {dismantfing and removing the debrises away from the work site and finishing the exposed ~ fSurface -smooth. providing grooves-or beads: wherever necessary. including: cost, conveyance, loading, unloading, royalties and taxes of all materials , cost of all labours, scaffolding, sundries,T&P required for the work etc. Complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Stee! and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in. proper position as directed by the Engineer-in-charge.
Footing
Plinth Bend
Column
Ground Floor
1st Floor
2nd Floor
3rd Floor
Lintel
Ground Floor
1st Floor
2nd Floor
Roof Beam
Ground Floor
1st Floor
2nd Floor
Roof Slab
Ground Floor
1st Floor
2nd Floor
Stair case
Ground Floor
1st Floor
Flooring
SupplySupplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-500) (SAIL Only) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works ( 4th revision) including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment) ing, fitting and placing un-coated HYSD bar reinforcement complete as per drawing and & technical specification and Direction of the Engineer-in-charge.
Ground Floor
1st Floor
2nd Floor
Fly ash brick masonry in cement mortar (1:6) in Foundation & Plinth using bricks of “25cm x 12cm x 8cm" size having a crushing strength of not less than 75 Kg. Per Sq. Cm. including immersing in water till saturation before use, Including splays cutting, circular molding, chamfering and corbelling and all similar type of operations with all necessary projections watering and curing etc. complete including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors as per drawing and Technical specification and as directed by the Engineer-in-Charge.
Ground Floor
Fly ash brick masonry in cement mortar (1:6) in Superstructure using bricks of “25cm x 12cm x 8cm" size having a crushing strength of not less than 75 Kg. Per Sq. Cm. including immersing in water till saturation before use, Including splays cutting, circular molding, chamfering and corbelling and all similar type of operations with all necessary projections watering and curing etc. complete including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors as per drawing and Technical specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
2nd Floor
3rd Floor
Fly ash brick masonry in cement mortar (1:4) in Superstructure using bricks of “25cm x 12cm x 8cm" size having a crushing strength of not less than 75 Kg. Per Sq. Cm. including immersing in water till saturation before use, Including splays cutting, circular molding, chamfering and corbelling and all similar type of operations with all necessary projections watering and curing etc. complete including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors as per drawing and Technical specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
12 mm (1/2") thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
2nd Floor
3rd Floor
16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
2nd Floor
3rd Floor
6mm thick cement plaster (1:4) over RCC works including deep chipping, finished smooth with proper thickness, watering, curing for required days with cost, conveyance, royality, taxes of all materials and labour with T&P required or the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
2nd Floor
Providing and Painting wall Surface one coat with Wall Primer to give an even shed before applying weather coat to Exterior walls including cost of Primer , labour, T&P all complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
2nd Floor
3rd Floor
Providing and Painting with Two Coats of Acrylic Smooth exterior paint of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, , of all materials, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Ground Floor
1st Floor
2nd Floor
Finishing plastered surfaces of walls with Cement based Putty & making smooth to receive painting including cost of Birla Putty with all scaffolding and staging charges including cost, conveyance, , of all materials, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance, ,, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) with all scaffolding and staging charges including cost, conveyance, , of all materials, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm & above in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade, with polishing and rubbing ,forming and nosing,moulding edge including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge
Ground Floor
1st Floor
Providing, Fitting & Fixing of Granite Stone in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all etc. complete as per the direction of the Engineer-in-Charge
Providing, Fitting & Fixing of Laterite Stone cladding in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat Adhesive, cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all etc. complete as per the direction of the Engineer-in-Charge
Ground Floor
1st Floor
Providing, Fitting & Fixing of CLUSTER STONE cladding in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat Adhesive, cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all etc. complete as per the direction of the Engineer-in-Charge
Supplying, fitting and fixing vetrifed tile in floors of size 600mm x 600mm of approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filling joints with epoxy grout of approved qualiy including cost of all materials, labour T&P etc required for the work. etc. complete as per the direction of the Engineer-in-Charge
Providing, Fitting & Fixing of Virtified tiles in Walls on 12mm thick Cement Plaster in Cement mortar (1:3) jointed with neat cement Slurry mixed with Pigments including cost of Tiles, labour, T&P all etc. complete as per the direction of the Engineer-in-Charge
Providing, fitting and fixing the M.S. grills and placing 12mm Sq bars in position including cost, covenyance and royalty of all materials and cost of all labour etc. complete as per the direction of the Engineer-in-Charge
Painting two coats to new Steel work with any approved shade over a coat of primer.including cost of all materials and labour T&p etc. complete as per the direction of the Engineer-in-Charge
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. etc. complete as per the direction of the Engineer-in-Charge
Supplying, Fitting and Fixing of Stainless Steel hand railing using 50mm dia of 2mm thick circular pipe as Balustrade as per approved design and specifications all etc. complete as per the direction of the Engineer-in-Charge
P.H Work:- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Ashirbad/Supreme/Oripalst) GF Floor -20mm dia C-PVC pipe (Ashirbad/Supreme/Oripalst)
25mm dia C-PVC pipe
1st Floor 20mm dia C-PVC pipe
25mm dia C-PVC pipe
Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) Ground Floor 25mm UPVC ASTM Pipe
32mm UPVC ASTM Pipe
1st Floor 25mm UPVC ASTM Pipe
32mm UPVC ASTM Pipe
40mm UPVC ASTM Pipe
50mm UPVC ASTM Pipe
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. G. Floor
1st Floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge G. Floor
1st Floor
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall G. Floor
1st Floor
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge.
15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN
15mm dia CP S.B Bib cock (CON-CHR-037KN)
20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN
15mm dia CP angle stop cock (FLR-ACR-5053N)
15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN
HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565
15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN
Shower Arm (SHA-CHR-477)
Over head shower 100mm dia round (OHS-CHR-1999)
25mm dia brass or gun metal full way valve(shakti make)
32mm dia brass or gun metal full way valve(shakti make)
40mm dia brass or gun metal full way valve(shakti make)
50mm dia brass or gun metal full way valve(shakti make)
15mm dia CP Flange
15mm dia CP Extention Nipple
125mm CP grating
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Second floor
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In (Ashirbad /Oriplas/Oriplast) Ground floor
110mm dia U-PVC SWR pipe
75 mm dia UPVC SWR Pipe
110mm U-PVC door tee
110mm U-PVC Plain tee
110mm U-PVC door bend
110mm U-PVC plain bend
110mm dia U-PVC 'P' trap
110mm dia U-PVC Plain Shoe Bend
110mm dia U-PVC offset with out ear
110mm dia U-PVC cowl
75 mm dia UPVC plain bend (supreme/ashirvad)
PVC clamp suitable for 75 mm to 110mm dia pipe
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware/Hendware/Cera/Somany/Kerovit)
One piece commod(Hindware)ELEMENT Cat No.92084.
Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan ((Parryware/Hendware/Cera/Somany/Kerovit)
Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) (head)70002
Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge Half pedestal Basin(Hindware)No.91049+91115
Under Counter Basin (560x455) (H)10095 white
Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet)
15mm dia urinal spreader
32mm dia C.P. dome waste
Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail
CP Towel ring
Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge. CP soap holder
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm glass shelf with CP/NP guard rails
Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design mirror(Parryware)
Supplying all materials, labour, T&PProviding fitting & fixing of toilet Cubicle material and specification as detailed below (Cubicle) (1000mm(W)81550mm(D)x2003mm(H) Providing Intermediate panel, Plaster & door: The intermediate panel is one continued panel without any joints. All intermediate panel is one continued panel without any joints. All intermediate panels, pilasters and doors shall be 12mm thick with edges chamfered. The solid compact laminate (Phenolic Core board)is based on thermosetting resins, homogeneously reinforced with celluloselfibres. Top surface on both sides is melamine coated which is scratch and impact resistant. Providing Hardware and fixing: All pilasters are to be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with and exteror polyamid coating quarantees resistance to breakage, heat, humidity and chemicals. The base of the adjustable foot will be anchored to the floor with a clearance height of 100mm. Aluminum U-Channel will be used for the fixing of intermediate panels to the wall. 1 unit. Compact laminated cubicle L Partition with door
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
R.C.P.C Cover
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. 1.40m dia x 2.00m deep soakway pit
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
110mm dia U-PVC Alround Concrete
160mm dia U-PVC Alround Concrete
Construction of 50 users RCC septic tank- 1 No
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 1x6.10x2.70x0.30
Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor
Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor (inside/outside)
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor (inside/outside)
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C floor and roof slabs up to 4.30m height
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
Supplying all materials, labour,T&P and providing 25mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips on new work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
Dewatering with 5 H.P diesel engine pump during excavation
Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge 160mm U-PVC plain Tee
Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.
110mm diameter U-PVC SWR pipes(Supreme/Ashirvad)
110mm U-PVC cowl
Sinking of 150mm size tube well through hand boring(water jet)method (1 nos.)
Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge
Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge
Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge
Drilling pilot bore from 0 to 360 metres
Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge
Reaming 100mm to 150mm dia
from 0 to 360 metres
Reaming 150mm to 200mm dia
from 0 to 360 metres
Reaming 200mm to 250mm dia
from 0 to 360 metres
Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge
from 0 to 360 metres
Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge
150 mm dia PVC casing pipe
from 0 to 360 metres
Cost of 150 mm dia PVC ASTM pipe (sch-80)
Cost of 150mm dia PVC slott cutting
Cost of 150mm dia C.I. cutter plug
Cost of bentonite powder
Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge
Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge
Supplying all labour T&P and grouting with cement slurry for sanitary sealing in the bore around the upper most 3 metres of 125/100mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge.
Cost of Cement
Supplying all labour, T&P and developing the tube well by 8 hours continuous pumping per day for a minimum of 7 cosecutive days or till clear sand free water is obtained as per the direction of the Engineer in charge
Fixing of submerssible pump set
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge
1.50 H.P single phase (vertcal submersible pump motor) 3 stage head range 20 to 35 metres, discharge 145 to 110 L.M.P with outlet dia of 25mm
DOL Control panel
2.50sqmm flat cable
20mm dia rigid UPVC pipes
Steel rope with cover
Well cap
50mm size CI bracket
32mm dia steel short piece
Labour charges for lowering including transportation
Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge
32mm HDPE pipes
ELECTRIFICATION WORK:- Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Group A
Group B
Group C
Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)
Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp modular plug with switch with all conection. on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)
Supply& fixing of Modular type 6 Amp one way switch and 6 A socket outlet with metal box and modular cover Separate Board on surface or recess including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION))
Submains:Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm.
2 x 2.5 sq.mm. + 1 x 1.5 sq.mm.
2 x 4.0 sq.mm. + 1 x 1.5 sq.mm.
4 x 6.0 sq.mm. + 2 x 4 sq.mm.
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
12 Way SPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Fittings & Fixtures
Supply of 18 watt Surface mounted indoor type Round/square LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge
SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro
Supply of 36 watt 2'' X2'' SQUARE Light Surface mounted indoor type square LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge.
Supply of 350 watt FLOOD Light Surface mounted indoor type Round/square LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge.MAKE:PHILIPS/HALONIX/LT/HPL
Supply ,Installation and testing of Surface mounted indoor type 40 WATT LED Extruded Aluminium lumen o/p not less than 2000 lm LED Batten with Opal Diffuser, IP20, & Functioning as per Product TDS complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge.MAKE: PANASONIC/PHILIPS/BAJAJ/CROMPTON/WIPRO/HAVELLS/LT
Supply delivery, installation, testing & commissioning of following types of 10 watt LED based BOLLARD with aluminium pipe housing with CCT:3000K IP66 Height -600 MM mp complete etc.as required and as per the direction of E.I.C. MAKE: PANASONIC/ PHILIPS/ BAJAJ/ CROMPTON/ WIPRO/ HAVELLS/ LT
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton
Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
FACADE Lighting Supply, Installation, Testing and commissioning of LED FIXTURE - 150W, LED, RGBW (DMX 512 Compatible)light, flexible in doing the programming and making scenes more aesthetically with DMX,IP 66 Light glueless with IP 68 Cable gland . The housing in light weight, made of high strength die cast aluminium and coated by static powder making it weather resistant.Protection screen in ultra white tempered glass with high impact resistance IK07 Rated.. High precision dial ensures precision angle adjustment.Premium thermal management by high heat conductivity aluminum alloy and thermal fins. Pure Polyester powder coating in Standard Grey Colour. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP65 rated. Power LED Module with high efficacy LED's, on Printed Circuit Board with metal core plate. CRI > 80(for white),P.F>0.9,voltage input AC100- 240V,50/60Hz. In-Built Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current. Lens made of PC. 10/15 deg. beam angle. Estimated LED Lifetime is 50,000 hours minimum. LM80 report from LED Manufacturer. .MAKE: HALONIX/OSRAM/LEKSA LIGHTING/LT/ENDO/BAJAJ
Supply, Installation, Testing and commissioning of LED FIXTURE - 36W, SPOT LED, Tunable White (DMX 512 Compatible)light, flexible in doing the programming and making scenes more aesthetically with DMX,IP 66 Light glueless with IP 68 Cable gland . The housing in light weight, made of high strength die cast aluminium and coated by static powder making it weather resistant.Protection screen in ultra white tempered glass with high impact resistance IK07 Rated.. High precision dial ensures precision angle adjustment.Premium thermal management by high heat conductivity aluminum alloy and thermal fins. Pure Polyester powder coating in Standard Grey Colour. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP65 rated. Power LED Module with high efficacy LED's, on Printed Circuit Board with metal core plate. CRI > 80(for white),P.F>0.9,voltage input AC100- 240V,50/60Hz. In-Built Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current. Lens made of PC. 10/15 deg. beam angle. Estimated LED Lifetime is 50,000 hours minimum. LM80 report from LED Manufacturer.MAKE: HALONIX/OSRAM/LEKSA LIGHTING/LT//PANASONIC/BAJAJ
Accessories -Supply,Laying,Connecting, Testing & Commissioning Jumper Cable,IP RATED JUNCTION BOX - Luminaire to Luminaire interconnection 4P DMX cable 2m (10 pcs set) ; GI FLEXIBLE CONDUTE 20MM, GI SHADEL 25MM,GI 3WAY JB 25MM ,IP RATED WATERPRROF CONNECTORS ETC as per direction of enginering in charge.
Supply, Installation, testing & Commissioning of following armoured copper power cable a. 3 x 2.5 sqmm with pvc pipe ETC as per direction of enginering in charge.
Supply installation testing and Commissioning of DMX Wire 2Core Shielded cable Network wiring consists of a shielded twisted pair, with a characteristic impedance of 120 ohms, with a termination resist or at the end of the cable farthest from the controller to absorb signal reflections
Supply, Installation, Testing and commissioning of DMX Splitter 1 in 8 out , Booster, Input Power DC 12-24V input, 100-240V, 24VDC plug-in power adaptor included Power Consumption 4.5W max. Housing made of Polycarbonate, Surface mount or DIN-rail mountable, Output four 3-pin terminal sockets , Connections Two piece compression screw terminals , Protection Rating IP65.with Five Year Warranty
Supply, Installation, Testing and commissioning of of L.T. indoor floor /wall mounted type distribution boards made out of 2mm thick CR sheet metal cubicle fixed on m.s. channel baseIncomer:1 50A 4P MCCB(16 KA) with adjustable thermal setting+NL,Bus bar: 4 nos.80A Busbar duly sleeved ,Outgoing: 4 Nos 25A 4P MCCB 18 ka with adjustable thermal setting,3 Nos 40A 4p MCCB 18 KA ,Instruments: 1 set.LED type phase indicating lamps with control fuses ,1 no 250/5A CT operated Digital ammeter ,1nos. Digital voltmeter,Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat.
S/I/T&Commissioning of LT indoor floor mounted cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. . 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 no 200A 4P MCCB 36kA with TMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) Busbar- 04 numbers of 200 Amps ALUMINIUM bus bar Electrolytic busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 02 nos 125 A 4P MCCB 36kA , 3 nos 100 A 4P MCCB 36kA ,02 nos 63A 4P MCCB 25kA , 03 nos 40A DP MCB 10kA with TMR based release with adjustable overload ,Icu=100%Ics, . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-400Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) (iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
FLOOR PANEL:Incomer:100A 4P MCCB (25 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 100 A CU Busbar duly sleeved OUTGOING : 3 Nos 63 A 4P MCB. (10 KA) Instruments: 1 set.LED type phase indicating lamps with control fuses Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge..MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS Make of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9
HVAC PANEL:Incomer:1 125 A 4P MCCB (36 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 160A CU Busbar duly sleeved Bus bar: 4 nos. 100A CU Busbar duly sleeved OUTGOING:4 Nos 40A 4P RCB0. (300 MA) Instruments: 1 set.LED type phase indicating lamps with control fuses.OUTGOING:6 Nos 63A 4P MCCB. (18 KA) Instruments: 1 set.LED type phase indicating lamps with control fuses 1no. Digital multi function meter semealess integration with with,Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat.Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat.
Supplying ,installation ,testing & commissioning of 5 KVA ,240V UPS with all required accessories & suitable nos 12v battery,220Ah tubular type,battery rack as per the direction of Engineer in Charges.Make-V-guard/Microtech/Luminous . (only for common area)
Supplying, laying & testing of following size of PVC insulated XLPE shethed / strip armoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walss / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. MAKE: FINOLEX/ KEI/ POLYCAB/HAVELLS/RR CABLE
3.5 core x 185 sq mm Aluminium armoured Cable.(FOR MAIN PANEL)
3.5 core x 50 sq mm Aluminium armoured Cable.(FOR FLOOR /HVAC PANEL)
3 core 2.5 sqmm control Aluminium armoured Cable
3.5 core x 10 sq mm cooper armoured Cable.(FOR hvac Outdoor PANEL)
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.
3.5 core x 185 sq mm brass double compression gland and aluminium lugs
3.5 core x 50 sq mm brass double compression gland and aluminium lugs
Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room..
Supplying of following Materials.
Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
Danger Board.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.40 MB
BOQ_573801.xls
BOQ • 0.47 MB
DTCN1.pdf
Tender Documents • 1.51 MB
Download all tender documents and submit your bid