Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹3.4 Cr+₹95.0 L (38.7%)Rejected-Finance | ₹3.4 Cr+₹95.0 L (38.7%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹3.4 Cr+₹99.2 L (40.4%)Rejected-Finance | ₹3.4 Cr+₹99.2 L (40.4%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹3.8 Cr+₹1.3 Cr (54.1%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹3.8 Cr+₹1.3 Cr (54.1%) | L4 | Rejected-Finance Not being L1 |
| 5 | Rejected-Technical HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | - | - | Rejected-Technical Documents not produced as per NIT/ PQC |
Tender Value
₹3.5 Cr
EMD Value
₹4.2 L
Closing Date
17 Jul 2023, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
PROVISION OF SOLAR POWER STATION ALONGWITH CONNECTED ITEMS AT CGDHQ 15 OKHA
2023_MES_597771_1
83019/E8
Open Tender
Civil Works
Lump-sum
270 days
OKHA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE I CG PORBANDAR
₹4.2 L
Yes
3 Oct 2023
23 May 2023
19 Jul 2023
23 May 2023
17 Jul 2023
3 Jul 2023
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE AND EARTH WORK EXCAVATION ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (BLANK)
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/ CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (CHAIN LINK FENCING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (SOLAR POWER GENERATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (AREA LIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL ELECTRIC SUPPLY: S & F BEE energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Crompton (Enerion HS/ Havells (Efficiencia Neo)/ Orient (Hector-500)
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S&F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
Supply and fix modular MCB, 25/32Amps, 1module complete all as specified and directed. Make: Legrand/ Scheider/ Hager
External Water Supply: Supply and installion of submersible pump set , electric drivern 3 phase, 440 V (+10 or -10), confirming IP 68, SS Body, CI/Bronze impeller of head range 28-40 m, discharge 8.2-2.0 LPS capacity including starter installation and fittings , etc. complete all as directed by Engr in charge. Make :- Kirloskar / equivalent in Crompton
Refrigeration & AC: Supply and installation of hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 Tr complete all as directed by Engr-in-charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as directed by Engr-in-charge
SOLAR POWER PLANT: Design, Supply, Installation, Testing & Commissioning of ground mounted on grid connected solar pv plant of capcity 260 KW, comprising of Design & provision of solar panel with anti glare coating with Si-Monocrystaline or its latest type PV Module, roof top structure power conditioning unit (Inverter Power evacuation equipment such as cable and Panels, Fire safety kit, earthing and lightening arrestors, all accessories etc including all preliminery Charges as per PGVCL and Gujarat Energy Development Agency (GEDA) guidliness including all electrical works required for erection andcommissioning of Solar PV plant with fixed tilt type structure and including all type of necessary civil works comprising of following sub-components/sub-systems and with following specifications complete all as specified and directed by Engineer-in-Charge:- (a) P V MODULES :-Solar Photovoltaic module of Silicon Mono crystaline /Mono Perk/ Mono Bifacial SPV cells having peak power rating from 335Wp to 540Wp as per site requirement for 260 KW. Identification and traceability - Each PV module must use a RF identification tag (RFID) which must contain the following information:- (i) Name of the manufacture of PV Module. (ii) Name of the manufacturer of Solar cells (iii) I-V curve for the module (iv) Peak Wattage, Im, Vm and FF for the module.(v) Name of the test lab issuing IEC certificate (vi) Unique serial No and model No of the module(vii) Country of orign (Make in India only) (viii) Date and year of obtaining IEC PV module qualification certificate (ix) Month and year of the manufacture (separetely for solar cells and module) (x) Other relavent information on traceability of solar cells and module as per ISO 9000 series
Makes of PV Module: BHEL, Photon Energy System, Tata Solar Power, Websol, Waaree, Indosolar, Vikram Solar, Gold, Adani (b) MOUNTING STRUCTURE :- Hot dip galvanized steel mounting structure for mounting of modules/array/panels etc such structure should have angle of inclination as per the site conditions to take max insolation, mounting structure shall be designed to withstand in wind speed of 180 KM per hour , fasting arrangements grouting, clamping etc be provided to secure the installation against specific wind complete all as specified. The mounting structure steel shall be as per latest IS, and galvanisation of the mounting structure shall be in compliance with the MNRE guidelines. Structural material shall be corrosion resistent and electrolytically compatiable with the materials used in the module frame. The nuts, bolts and fasteners used shall be of Hot dip galvanized steel/ Stainless steel. The structures shall be designed to allow easy replacement of any module.The base columns shall be made with reinforced cement concrete(Design Mix) as per design based on site related data which shall be done by contractor at his own cost.The contractor quoted rates shall be deemed to inclusive of all civil works required for mounting structure and its foundation etc NOTE:- (i) All civil structure details including foundation for mounting structure shall withstand wind speed of minimum 180Km/Hr duly vetted by IIT/ NIT to be submitted by contractor to GE before commencement of work (ii) The ground clearence of PV module below lower incline should not be less than 0.6m.
(c) SOLAR GRID INVERTER : supply testing and installation of Solar Grid Connected Inverter of appropriate capacity to provide output capacity of 260 KW AC as per site requirement and designed capacity to give maximum yield for installed capacity for 260 kwp plant, 415v ,3 phase, AC operated complete all as specified and directed. make:- ABB/ SCHNEIDER/ SEIMENS/ SUNGROW . Online inverter should have a facility of online data loggers for monitoring of solar power generation and solar meters/bi directional meters of suitable specification to be installed for complete/ utilization of solar power generated on grid with in the desired location only (d) ACDB Panel 260 KW shall be provided for interconnection of Solar Power Plant with existing DB at site ACDB shall be made of CRCA sheet with thisckness not less than 2mm as approved by GE.it shall be of dust, water & vermin proof arrangement with IP 65 protection with transparent covers.Make:- Schneider/Siemens/ABB/L&T/ as approved by GE. (e) Array Junction Box:- Array Junction Box as per site requirement for 260 KW Inverter with fuse and SPD-02 No. AJB's shall be made of GRP/FRP with dust, water & vermin proof arrangement with IP 65 protection with transparent covers & It shall have SPD and Reverse blocking diodes.Make:- MNRE/GOI approved. (f) AC Disconnect switch 260 KW-01 No. Make:- Schneider/Siemens/ABB/L&T (g) DC CABLES - Solar DC Copper interconnecting cable between module to module of solar grade,XLPO UV resistant made of Multistrand Tinned Copper Coductor of size 1 Core 4 mm² as per site requirement. NOTE: (i) All DC cables from PV to PV and DCDB must be laid in PVC conduit of proper size for protection. (ii) The cost of cable and conduit are deemed to be in quoted rates
(h) AC CABLES - AC cable From Inverters to ACDB with Copper flexible cable 1.1kv, of suitable size , make (Havell's/Finolex/Polycab) - as per site requirement. (j) MC4 Connector - 30 Nos. Make:- Multicontact/Lapp/Phoenix or equivalent as approved by GE. (k) RS 485 Communication cable - as per site requirement.. Make:- D-link/Advanced/Lapp/Helukable or equivalent as approved by GE (l) Installation kit and accessories (Cable trays, Lugs, Routing accessories, cables, conduits etc.) - 01 Lot (m) Copper PVC Flexible cable 1.1 KV 16 Sqmm , green colour for earthing connections (n) Any other items of Civil / Electrical nature work required for the 260 KWp PV plant. GENERAL NOTES : The items of Work mentioned in this Job shall be executed as per following :- 1. Entire work of solar power plant shall be got executed from firms who has GEDA registration and rating issued by ICRA/CRISIL/SMERA. The cost of applicable charges i.e., registration fees, DISCOM connectivity charges etc/permission from GEDA etc allas reqd deemed to included in rate in quoted Rate 2. Agency must have minimum 5 years of experience in the field of execution of solar projets and operation and maintenance of solar plant. 3. PCC foundation if reqd shall be deemed to be included in the quoted rate. 4. MoU shall be submitted by contractor with eligible solar power firm approved by MNRE & GEDA.
5. The Contractor shall also be responsible for renewal/ replacement of parts fittings/fixtures filling of Solar modules, inverter, mounting structure etc during the defect liability period. 6. The Contractor shall also be responsible for maintenance and operation for Solar Power system for Five Year. The cost of Maintenance and operation deemed to be included in quoted rate. Maintenance of log sheet and all maintenance record shall be responsibility of contractor and stationary shall be provided by the Contractor. Format of log sheet and maintenance records etc shall be decided by GE/Engr-In-Charge. Solar Panel water servicing, panel Cleaning, Area cleaning surround the plant room etc shall be the responsibility of contractor. 7. For full details of description of items, scope and specification contractor shall refer to Particular Specifications given in succeeding pages. Contractors are advised to read the description alongwith PS before quoting rate. 8. After successful installation contractor should provide final drawing of electrical wiring, test certficates, warranty certificates, manuals to the Engr-in-Charge. 9. A display board of size 4 ft x 3 ft made of MS 40 mm x 40 mm square pipe and flexes is to be supplied and errected at both the solar plant site showing information as directed by Engineer-in-Charge the rate of which shall be deemed to be included in the quoted rates.
Supply, install, testing and commissioning AC, 3 phase, 50 Hz 315 KVA capacity transformer Energy Efficient level 2 step up Indoor type 11 KV/ 433 V (at no load) copper wound, oil cooled confirming to IS: 1180 part I and its ammendement up to date complete with oil tank including first of ISI marked insulating oil up to the top level indicator breather with silica gel lifting hooks drain valve air vent valve tackel wheel with channel and locking arrangement to put on the plinth with external cooling tubes core type delta connected on primary (HV) side star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) and neutral brought on secondary (LV) side OFF load tap changer in suitable steps/position on HV side to give output 433 volt on LV side and provision of following accessories and connecting with electrical system earthing etc including all jointing materials PCC foundation as per OEM design/recommendation testing and commissioning all as per IS 1180 Part I etc complete with all standard items as under:- (a) 03 Nos porcelain H. T. bushings with Brass/gun metal bushing rods/ cable Box complete with nuts and washters on primary (HV) side suitable for HT 11 KV XLPE cable of size 3 core x 240 sqmm. (b) 04 Nos porcelain with brass/GM bushing rods complete with nuts and washers on secondary (LV side suitable fo LT 433 V XLPE cable of size 3.5 core 185 sqmm (02 run)and neutral connection. (c) Oil conservation with filter type drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosive vents. (f) Thermometer pocket on tank cover. (g) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with term reading pointer max term indicating and resetting device.
(h) Rating plate with terminal markings. (i) Two earthing terminals on tank/tank cover to facilitare fixing of 50x6mm Gl earth strip. (k) Oil level guage. (l) Oil drain and filter valves (m) Oil filler hole with cap/plug with connections complete. (n) Lifting lugs (o) Air relief valve plug (p) Four plan solid cast steel detachable rollers. (q) First fill of fresh oil conforming to revant IS and having dielectric strength not less that 60 KV with 2mm gap. (r) Separate neutral bushing to be provided for earthing. (s) Provision of 2 Nos danger boards 250/200 mm size made out of 1.6mm thick plate vitreous enameled white with letters figures of voltage and conventional skull and bones in signal red colour on front side. The rear side of the plate also be enamelled. (t) Any other fittings/accessories so as the whole transformer to IS-1180. Note: (a) Transformer shall be placed upon a PCC/RCC platform and of size as recommeded by the OEM. (b) Cost of foundation shall be deemed to be included in the rate quoted for the transformer. Make: VOLTAMP/ CG/ ITE/Kirloskar/ BHEL
Supply installation, comissioning & testing of outdoor type non extensible 11 KV, SF6 insulated compact ring main unit (RMU) with short circuit peak making current 50 KA and short circuit breaking current 20 KA fully arc proof metal encloused free standing floor mounting motorised operated fixed type SF6 insulated, 2 Nos. Load break switches 400 Amps (as incoming) and 1 No SF6 circuit breaker 200 Amps ( as outgoing) with self-powered micro-processor based relays (as and related CTs, cable switch module and an interlocking mechanism with the earth switches, degree of protection IP 54 with the following components complete all as specified and directed (a) 2mm stainless steel tank filled with SF6 comprising of 2 Nos isolators and 1 No SF6 circuit breaker (b) Blank (c) Self-powered micro processor controlled numeric relay comprising of 03 pole over current, one pole earth fault protection relay (d) Manual push button for emergency trip (e) Internal bus earthing with fat Gl strip of size 50x6 mm. (f) Copper bus bar. (g) Manual mechanism. (h) Front access & bottom entry of HT cables (j) In case of bus bar extension the same should be achieved through "plugin bus bars only, bolted type bus bars are not acceptable (k) The bus bar should be extendible and connectable , the bus bars should not exceed the size of RMU/Cubicle (l) The cable box should have bottom gland/base plata for cable entry and front cable covers for cable access (m) The live line indicators should be of LCD display type due to their higher life taking the required power from the capacitive coils situated at as the cable bushings (n) Manometer
NOTE: (i) The RMU shall be perchased from the Original Equipment Manufacturer (OEM)/ OEM authorized channel only. (ii) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs .. etc for approval of the Engr-in-charge. (iii) The bidder shall intimate the Engr-in-charge of the routine tests in accordance with IEC 62271-200 & IEC 62271-100 in the OEM factory in presence of a representative nominated by the Engr-in-charge before dispatch. Make: SCHNEIDER/ ABB/ SIEMENS
Design, fabricate, supply , testing and commissioning of factory made LT Feeder Pillar box outdoor type fabricated out of 3 mm thick CRCA sheet steel front and rear openable vertical type installed over properly supported legs suitably grouted to PCC includiing Copper Bus bar RYB and N of 1000 Amp capacity one set with internal wiring , including the following accessories complete with labour charge including PCC work all as specified & directed i) ACB 800 amp Four pole having short circuit current capacity not less than 65KA, electrical draw out type- 01 no (incoming) ii) MCCB 250 amp FP 35 Ka 6 no (out going) iii) MCCB 200 amp FP 35 Ka 1no (out going) v) Voltmeter 0-500V - 01 Nos. vi) Ammeter of Capacity 300 A - 01 Nos vii) Phase indicator lamp RYB - 01 set of three
Supply and installation of 11 KV, single phase, out door oil cooled CT of ratio 400/5-5 Amp, class 1.0 / 5P10, burden 15 VA complete all as specified & directed
Supply and installation of 11 KV single phase out door oil cooled PT of ratio 11 KV/rt3/110 V/rt3/110V/rt3,Class 0.5-3, Burden 50 VA – 50 VA complete all as specified & directed
Supply of Bi directional 3 phase DLMS type integrated meter with inbuilt CT& GSM Modem energy meter having LCD display,50 Hz ± 5%,Provision of sealing on mains cover and terminal cover, IP 51,tamper information, inbuilt battery back up to active its display in absence of power. Optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, (3X 240V (P-N), -/5A) complete all as specified & directed Make : secure /HPL
Supply of 3 phase DLMS type integrated meter with inbuilt CT& GSM Modem energy meter having LCD display,50 Hz ± 5%,Provision of sealing on mains cover and terminal cover, IP 51,tamper information, inbuilt battery back up to active its display in absence of power. Optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, (3X 240V (P-N), -/5A) complete all as specified & directed Make : secure / HPL
Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 110/95 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as specified and as directed by Engr-In-Charge.
SUNTASTIC ENGINEERNIG PRIVATE LIMITED
SOLARIUM GREEN ENERGY PRIVATE LIMITED
Phoenix Infra
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .