Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-Finance | ₹28.7 L | L1 | Accepted-Finance ok |
| 2 | L2₹36.0 LAccepted-Finance WZ 66 SRI NAGAR RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹36.0 L | L2 | Accepted-Finance ok |
| 3 | Rejected-Technical | - | - | Rejected-Technical Documents are not Found as per NIT |
| 4 | Rejected-Technical G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | - | - | Rejected-Technical Documents are not Found as per NIT |
| 5 | Rejected-Technical B 1124 SHASTRI NAGAR DELHI 110052 | NORTH | DELHI | 110052 | - | - | Rejected-Technical Documents are not Found as per NIT |
Updated dates
Tender Value
₹34.8 L
EMD Value
₹69,638
Closing Date
23 Jan 2026, 3:00 pmClosed
Executive Engineer E
EE/ELD-9/DDA
Running,maintenance and operation of pump sets and allied accessories at UGR near J.J. colony in Block C 1 Sector 27 and 2 Nos. submersible pump sets and D.G.sets in Pkt. 2 Block C Sector 27 Rohini.
2026_DDA_893306_1
28/EE/ELD-9/DDA/NIT/2025-26
Open Tender
Electrical Works
365 days
Rohini
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹69,638
In the Chamber of SE/E/RZ
5 Feb 2026
9 Jan 2026
24 Jan 2026
9 Jan 2026
23 Jan 2026
15 Jan 2026
13 Jan 2026
Running,maintenance and operation of pump sets and allied accessories at UGR near J.J. colony in Block-C-1, Sector-27 Rohini as per inventory, terms & conditions attached by deploying following labour:- Wireman cum opeartor Grade-II-2 Nos.one in each shift i.e. from 6.00 p.m. to 02.00 p.m. and 02.00 p.m. to 10.00 p.m. or as when required by engineer-in-charge.
Khallasi cum security guard-1 Nos.-one in night shift i.e. from 10.00 p.m. to 6.00 a.m.or as when required by engineer-in-charge.
36 WLED Batten light (System lumen efficacy >135 lm/Watt) Supplying & replacement, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Supplying & replacement following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. i/c rebate for dismantle material a) 250 A,36KA,FPMCCB
100A, 30KA, FPMCCB
Running,maintenance and operation of 2 Nos. submersible pump sets & DG sets in Pkt-2 Block-C, Sector-27 Rohini as per inventory, terms & conditions attached by deploying following labour:- Wireman cum opeartor Grade-II-2 Nos.- one in each shift i.e. from 6.00 a.m. to 2.00 p.m. and 2.00 p.m. to 10.00 p.m. or as when required by engineer-in-charge.
Khallasi cum security guard-1 Nos.-one in night shift i.e. from 10.00 p.m. to 6.00 a.m. and 10.00 p.m. to 6.00 a.m.or as when required by engineer-in-charge.
Lifting out of submersible pump set 5 H.P. to 12.5 H.P. from existing bore well i/c dismantling pipe line, p/set etc. complete as reqd.
Lowering of submersible pump set 5 H.P. to 12.5 H.P. in the existing bore well i/c making water proof joint, making connection to pump testing etc. complete as required.
Repair and rewinding of 12.5 HP 3Phase 415 Volt Submersible Pump set i/c replacement of all Burnt/damaged parts including testing, commissioning etc complete as required.
Repair and rewinding of 5 HP 3Phase 415 Volt Submersible Pump set i/c replacement of all Burnt/damaged parts including testing, commissioning etc complete as required.
Repair and rewinding of 40 HP 3Phase 415 Volt booster Pump set with motor i/c replacement of all Burnt/damaged parts including testing, commissioning etc complete as required
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 40 W fixture
Providing & replaement and fixing of CO2 type Fire Extinguisher of capacity 4.5 kg conforming to IS, bearing ISI mark, consisting of High Pressure seamless steel cylinder (IS) and duly approved by Chief controller of Explosive Nagpur, fitted with wheel type valve, fully charged with CO2 gas (IS), with non-conductor of electricity discharge PVC horn along with Bend Pipe, internally siphon tube, & mounting brackets compolete as required
Supply & replacement, Testing and Commissioning of 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 4 Each 2595.00 10380
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.16 MB
TenderDocument.pdf
Tender Documents • 1.61 MB
BOQ_938941.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid