Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.7 LAccepted-AOC | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹16.5 L+₹1.5 L (9.81%)Rejected-AOC 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | 2 | Rejected-AOC 2nd | |
| 3 | 3₹17.9 L+₹2.9 L (19.6%)Rejected-AOC | 3 | Rejected-AOC 3rd | |
| 4 | 4₹19.5 L+₹4.5 L (30.0%)Rejected-AOC | 4 | Rejected-AOC 4th | |
| 5 | 5₹19.5 L+₹4.6 L (30.3%)Rejected-AOC D 2 212 JEEVAN PARK PANKHA ROAD UTTAM NAGAR WEST DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | 5 | Rejected-AOC 5th |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
14 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
SPL REP TO MAP QTR (P-175) PHASE-I AT VAYUSENA VIHAR AT 12BRD UNDER GE (AF) TUGHLAKABAD
2022_MES_562355_1
GE/TKD-54/2022-23
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹41,000
Yes
7 Mar 2023
16 Nov 2022
16 Dec 2022
23 Nov 2022
14 Dec 2022
30 Nov 2022
Amount
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed by Engr-in-charge.
M&L for bricks works with sub class "B" bricks straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed by Engr-in-charge.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engr-in-charge.
M&L for marble stone chipping of desired colour grit wash on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement : 4 coarse sand) the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 12mm white cement plaster (1:1/2:2) (1 white cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engr-in-charge.
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement including taking down cement plaster or concrete, brick surface and raking out hacking for key scrubbing down with water to receive plaster complete all as specified and directed by Engr-in-charge.
M&L for applying two coats of oil emulsion distemper over 1mm thickness birla/JK wall care putty complete all as specified and directed by Engr-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm and but n,exc 4 Sqm each for archives soffits, linings window boars etc complete all as specified and directed by Engr-in-charge.
S&F 105x60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and directed by Engr-in-charge.
S&F 125x60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete all as specified and directed by Engr-in-charge.
S&F factory made solid PVC door frame in repair of size 50mmx47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification given under SSR Part-II 2010 and making good the disturbed surfaces complete all as specified and as directed by Engr-in-Charge.
S&F factory made solid PVC door shutter of 30mm thick style consisting of frame made out of MS tube for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side, as gap insert for top rail & bottom rail, paneling of both side prelem PVC sheet to be fitted in the MS frame welded or sealed to the sites and rails with suitable PVC sheet beading and jointed together with solvent cement supply and fixing in the frame at site all as specified and shown in SSR Part-II at Page Nos 146 to 148 complete all as specified and as directed by Engr-in-Charge.
S&F stainless steel butt hinges with stainless steel pins medium weight 100mm long fixed including welding to Angle Iron door frame or fixed to wooden chowkhats complete all as specified and directed by Engr-in-Charge.
S&F Extruded aluminium alloy handles, fabricated type, anodised 150 mm size complete all as specified and directed by Engr-in-Charge.
S&F aluminium alloy, anodised, sliding door bolt of 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section, fixing bolts, sliding bolts of extruded section or cast aluminium alloy and fixed length 300 mm complete all as specified and directed by Engr-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section fixed complete all as specified and directed by Engr-in-Charge.
M&L for Pre-laminated particle board, 18/19 mm interior grade, pre-laminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge.
S&F Continuous (piano) hinges MS bright finish or electrogalvanised 30 mm width of flaps (when open) complete all as specified and as directed by Engr-in-charge.
S&F for hasp and staples 100mm long aluminium anodised complete all as specified and as directed by Engr-in-charge.
M&L for flush shutter 40 mm thick solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and as directed by Engr-in-charge.
S&F of single legged Aluminium floor door stopper 140mm long with alloy body and tongue anodised with hard drawn steel spring complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete reinforced in any position including cut of bars as required complete all as specified and directed by Engr-in-charge.
M&L for Reinforced cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge.
M&L for Reinforced cement concrete (1:2:4) type B1 20mm graded stone aggregate as Beams, Cantilevers, Bressummers lintels complete all as specified and directed by Engr-in-charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs etc. also splays between floors and beams, etc. complete all as specified and directed by Engr-in-charge.
M&L for Form work to soffits of suspended slab such as roof slab, floor slab etc n exc 200 mm thick rough finished surface of concrete slab complete all as specified and directed by Engr-in-charge.
M&L for rough finished surfaces if concrete formwork to sides and soffits if floor or roof beams haunching girder bressummer chajja shelves including supports complete all as specified and directed by Engr-in-charge.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge.
All as per sl item No 29 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge.
M&L for 100mm thick cement concrete (1:2:4) type B2 using 40mm graded stone aggregate as in path/ plint protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-charge.
M&L for cement concrete 100 mm thick (1:4:8) type D2 using 40mm graded stone aggregate complete all as specified and directed by Engr-in-charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge
M&L for factory made vibro compacted cement concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100mm thickness, M-50 grade With grey cement and pigment complete all as specified and directed by Eng-in-charge.
Dismantling of Stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slabs as in vertical surfaces such as risers of steps 20-25 mm thick over 15 mm thick rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing also moulding edges complete all as specified and directed by Engr-in-charge.
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed by Eng-in-charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
Dismantling of wrought iron or Mild Steel work of any description complete all as specified and directed by Engr-in-charge.
S&F roof trusses Fe 410-W (Gde E-250) quality -A (framed), trussed, purling, wind tie, crane gantries and rail and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engr-in-charge.
S&F corrugated steel sheet thickness 1.25 mm in wall cladding, steel gates and similar work, cut to size, hole punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turningup, mitred angles etc as required complete all as specified and directed by Engr-in-Charge.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Eng-in-charge. (200+210)
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge. (30+55)
Cutting out cracks to V-section in existing roofs or terracing cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified and directed by Eng-in-charge.
Roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc including removal of old treatment of any description and removing the debris to a distance of n.exc 50 cm away from plinth protection complete all as specified and directed by Engr-in-charge.
M&L for 10mm thick rendering in CM (1:4) using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and directed by Engr-in-charge.
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (wt not less than 150 gms /Sqm ) land on primed surface by forced application cocomplete all as specified and directed by Engr-in-charge.
Supply only water proofing compound complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in roof, kerbs, or mud stops rounded or chamfered on edges complete all as specified and directed by Engr-in-charge.
Disconnecting existing tanks Exc 250 & N exc 500, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and directed by Engr-in-charge. Note: Cleaning repairing etc measured separately.
Disconnecting existing tanks Exc 500& N exc 1000, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and directed by Engr-in-charge. Note: Cleaning repairing etc measured separately.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing)removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for Screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed by Engr-in-charge.
M&L for Non- skid ceramic coloured printed tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-charge.
M&L for Non-skid joint free ceramic coloured printed tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-charge.
M&L for rendering 10 mm thick in CM (1:3) finished even and fair as on brick or concrete surfaces for laying wall tiles complete all as specified and directed by Engr-in-charge.
M&L for colour joint free Glazed ceramic tiles in vertical surface 350x250x7mm/450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by Engr-in-charge.
S&F in repairs of vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union ccomplete all as specified and directed by Engr-in-charge. Note : Pillar tap shall be measured as supply only under respective item.
S&F in repairs of 40 mm waste coupling of PTMT (half or full threaded) Minimum weight 40mm-60gms complete all as specified and directed by Engr-in-charge.
S&F in repairs of pillar tap 15mm bore dia cast copper alloy with cap capston chromim plated screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly buts screwed for iron pipe complete all as specified and directed by Engr-in-charge.
S&F in repairs of for angle stop valves 15mm bore (for iron pipe) fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends including fixed in repair complete all as specified and directed by Engr-in-charge.
S&F in repairs of replacement Sink with drainage board made of stain less steel 1 mm thick kitchen or laboratories with plugs, washer and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915x 460x bowl size 410x330x160mm as approved by Engineer-in-Charge.
S&F in repairs of 32 mm waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms complete all as specified and directed by Engr-in-charge.
S&F in repairs of PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed by Engr-in-charge.
S&F in repairs of for bib taps 15mm bore (for iron pipe) cast copper alloy with fancy type chromium plated butter fly handle screwed down including fixed in repair complete all as specified and directed by Engr-in-charge.
S&F in repairs of 45cm long PVC connection with two no PTMT nut and rubber washers suitable for 15mm bore GI Pipe in replacement of existing one complete all as specified and directed by Engr-in-charge.
S&F in repairs of 125 mm fancy type shower roses brass chromium plated with C P arms for15mm bore GI pipe complete all as specified and directed by Engr-in-charge.
S&F 15mm bore GI tubing medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
All as per sl item No 72 but 20mm dia complete all as specified and directed by Engr-in-charge.
Taking up or down steel water tubing and connections including cleaning for refixing 15 mm bore complete all as specified and directed by Engr-in-charge.
Taking up or down 20mm bore GI tubing and connections, including cleaning for re-fixing complete all as specified and directed by Engr-in-charge.
M&L for providing and injecting chemical emulsion for post construction anti-termite treatment along external wall where the acron is not provided using chemical emulsion @7.5 Ltr per Sqm of the vertical surface of the sub-structure to a contact of 300mm including excavating channel roding etc complete all as specified and directed by Engr-in-charge.
M&L for filling voids in masonry using chemical emulsion @ one ltr per hole at a distance of 300mm center to centre (Apart) including drilling holes at 45 degree and replugging the existing floor etc complete all as specified and directed by Engr-in-charge.
Taking down carefully old unserviceable aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc. (for light, fan, socket or power) complete with fitting/fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good the disturbed sufaces of wall and floors by applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-charge. Note: Credit for the item should be made as per conditions separately.
Taking down carefully old unserviceable existing wooden board, maint switch, MCB DB boxes with MCBs, sheet metal boxes, cut out etc. of any size any capacity from boards complete and making good the dusturbed surfaces by applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-charge
Taking down old unserviceable existing sub main wiring of any type and desription including removal of teak wood batten or pipe by applying necessary periodically with one coat of putty and two coats of OBD to match with the surrounding complete all as specified and directed by Engr-in-charge
M&L complete for wiring with cable of size 1.5 sqmm single core copper multistrand conductor including continuous earth wire, using cable FRLS insulated(unsheathed) 1100 volts grade conforming to Is-694 drawn in to and including concealed PVC rigid conduit medium duty with all fittings and fixing accessories ISI certified IS 9537 part -3 and terminated in to pressed steel metal flush boxes suitable for modular accessories and including modular cover plates with frame for mounting switches, socket regulator, brackets etc and including necessary cement work including cutting chases pinning in making good to facing and pointing in cement mortar (1:3) to the ends or cutting chases for concealed conduit point wiring and making good disturbed surface complete all as specified and directed by Engr in charge for followings Note: Cutting not exc 4cm girth and 4cm width:-
One light point controlled by one, one way switch.
One fan point controlled by one, one way switch and regulator.
One 3 pin socket out let 5 amps independent.
One 5 pin, 5 amps socket point in same board with other switches.
M&L complete for wiring one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm single core copper multistrand conductor including continuous 1.5 Sqmm earth wire using cable FRLS insulated (unsheathed) 1100 Volts grade conforming to IS-694 drawn into and including concealed PVC rigid conduit medium duty with all fittings and fixing accessories complete all as specified and directed by the Engr-in-charge.
M&L for one 3 pin socket out let 15 amps independent but with cable of size 4.0 Sqmm in point wiring and 2.5 Sqmm in continuous earth wire with necessary accessories complete all as specified and directed by the Engr-in-charge.
S&F in repairs for modular switch one way 6 amps 1 module complete all as specified and directed by the Engr-in-charge.
S&F in repairs for modular switch one way 16 amps 1 module complete all as specified and directed by the Engr-in-charge.
S&F in repairs for modular socket 2 in 1, 5 pin 6 amps 2 module complete all as specified and directed by the Engr-in-charge.
S&F in repairs for modular socket 2 in 1, 6 pin 6A/16 amp 2 module complete all as specified and directed by the Engr-in-charge.
S&F in repairs for ceiling rose surface Bakelite 3 terminal complete all as specified and directed by the Engr-in-charge.
S&F in repairs of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed by the Engr-in-charge.
S&F in repairs of bell push, flush type, 5 Amp including necessary accessories complete all as specified and directed by the Engr-in-charge.
S&F in repairs of pvc/polycarbonate type Lamp holder, insulated body, with back plate for batten fittings complete all as specified and directed by the Engr-in-charge.
S&F in repairs of energy saving LED lamp 14 Watt, 230 volts 50 Hz complete all as specified and directed by the Engr-in-charge.
M&L complete for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 240 Sqmm and 1x40 Sqmm as in continuous earth wire drawn in to & including PVC conduit medium 25mm dia ISI marked complete with fittings and fixings accessories laid concealed complete and including necessary cement work including cutting chases pinning in making good to facing and pointing in cement mortar (1:3) to the ends or cutting chases for concealed conduit sub main wining and making good the disturbed surface complete all as specified directed by Engr-in-charge. Note: Cutting not exc 4cm girth and 4cm width as read.
S&F in repairs of 1x 20 watts (4 feet) watt mounted LED batten, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver including lamp as required complete al as specified directed by Eng-in-Charge. Make: Havells Cat Part No LUMINLINEBS20WLED840SPCWH Bajaj Cat Part No BCLSB 20 WH/Crompton Cat Part No LCTL18CDL /Fiem Cat No FLC03-A-20WT8CWJ
S&F in repairs of 1x9 watts (2 feet)wall mounted LED batten extruded aluminium heat sink provided for efficient dissipation & integrated electronic driver including lamp as required complete all as specified directed by Engr-in-Charge. Make: Havells Cat Part No LUMILINEBSWLED840SPCWH/Bajaj Cat Part No BCLSB10WH /Crompton Cat Part No LCTL-9-CDL/ Fiem Cat No FLC03-A-10WT8CWJ.
S&F in repairs of exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200 Copper winding of sweep 250 mm complete all as specified directed by Engr-in-charge.
S&F in repairs of MCB distribution board, sheet steel, phosphatised, powder printed with bus bar, neutral link, earth bar & din rail SPN distribution board 08 ways double door complete all as specified directed by Engr-in-charge.
S&F in repairs of MCB single pole & neutral 240 volts ‘C’ curve-10k, 40-60 Amp complete all as specified directed by Engr-in-charge.
S&F in repairs of MCB single pole 240 volts ‘C’ curve-10 ka, 20 Amp (power) complete all as specified directed by Engr-in-charge.
S&F in repairs of MCB single pole 240 volts, ‘C’ curve-10 KA. 06Amp (light) complete all as specified directed by Engr-in-charge. Make: Legrand /Schiender /Siemens
S&F in repairs of MCCB 3 Pole, 415 V Adjustable type, 160 Amps with breaking capacity 36 KA including necessary work complete all as specified directed by Engr-in-charge.
Excavation in trenches in soft/loose soil n. exc 15 mtr wide and next 15 mtr deep and getting out in soft loose soil for laying of cable foundation of pole and stay etc in complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning in trenches for protection of LT underground cable including watering and consolidation complete all as specified directed by Engr-in-charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available of size 23x11 5x7 5 CM (+8 tolerance) in trenches of underground cable complete all as specified and directed by Engr-in-Charge
Removing excavated materials of exceeding 50 mtr and depositing where directed at a level not exceeding 15 m above ground level from starting point complete al as specified and directed by Engr-in-Charge
Returning filling including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in-Charge.
M&L complete for drilling hole under hard standing /road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface and making good the disturbed surface if any complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of GE tube light grade 40 mm bore complete all as specified directed by Engr-in-charge. Make-BansalindaTC
Taking out old serviceable /unserviceable underground cable of any size from excavated trenches /pipes complete all as specified directed by Engr-in-charge. Note: Earth work segregating cable cover measured separately.
Supply and lay or fixing or passing in replacement through pipe cable XLPE (FRLS) with aluminium conductor with heavy duty stranded 1100 volts size of 50 Sqmm 3.5 Core complete all as specified directed by Engr-in-charge. Note: XLPE insulated PVC sheathing (heavy duty) armoured cable with aluminium conductor for working pressure upto and including 1100 volts to 5-7008 (Part 1) for PVC insulated cables with following features:- (a) Cable shall have fire retarded, low smoke (FRLS) compound added to it in the out sheathing as per IEC 754 (part-1) IEC-60332, Part-2 IFEE 383 ASTM 2x43 and ASTM 2X63 flame retardant compound (PR) as per EIC specification. (b) Inner sheathing shall be of extruded PVC. (c) Heat resisting PVC shall also be added to extrude inner and outer sheathing. (d) Cable shall also be supplied with sequences hall marking at every meter as the outer sheathing. (e) Ultra violet radiation resistances compounded comprising ton ASTMG-53. (f) Anti rodent and ant termite compound added. (g) PVC compounds of various grades as IS-5831 (h) Compaction conductors shall be shaped and arrangement for the same with be on the cable. Note- (i) Each cable shall be tested for all applicable routine tests as per 15-5831, IS-7008, BS-6745, BS-5467 and IEC 60502 and test reports shall be provided to GE. (ii) Type test as per relevant specification shall produce to GE. Make: Universal Cable Corporation of India/Havells/Polycab/ Nicco
M&L in replacement for Earthing complete with galvanized mild steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground in vertical position (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level and connected to galvanised iron earth strip 32x6 mm by means of nuts, bolts, check nuts and washers of galvanized iron or steel including PCC (1:2:4) type B-1 precast RCC cover slab with suitable handle made of 12 mm round bar including necessary excavation & earth work in any type of soil, 20 mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm dia bore light grade galvanised steel tubing upto 7.5 mtr length for drawing earth lead wire protection common slat, charcoal etc all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed by Engr-in-charge.
MOHIT ENTERPRISES
M/s Gravitas Enterprises
M/S RK Builders
SACHDEVA ENGINEERING WORKS
J.P. Enterprises
DP Traders
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .