| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | ₹1.8 Cr | L1 | Accepted-Finance LOWEST BIDDER |
| 2 | L2₹1.8 Cr+₹450 (<0.01%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | ₹1.8 Cr+₹450 (<0.01%) | L2 | Rejected-Finance 2ND LOWEST BIDDER |
| 3 | L3₹1.8 Cr+₹1,500 (<0.01%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | ₹1.8 Cr+₹1,500 (<0.01%) | L3 | Rejected-Finance 3RD LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
15 Jul 2025, 2:30 pmClosed
Superintending Engineer, SWEC, PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur
SITC of solar on grid and off grid systems LA solar lights FAS CCTV solar pump at 3 Ashram Hostels in Bankura including water purifier cooler and napkin vending disposal machine at Nivedita SC Central Girls Hostel Bankura
2025_WBPWD_867869_1
WBPWD/SE/SWEC/NIQ15/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹3.5 L
O/O of SE, SWEC,PWD, PWD Compound, Midnapur
24 Jul 2025
23 Jun 2025
17 Jul 2025
23 Jun 2025
15 Jul 2025
26 Jun 2025
26 Jun 2025
Amount
PART-A [LOCATION : Ramlalpur Ghanaban High School Ashram Hostel, under mejia block / Pakanna S.C Boys Ashram Hostel under Barjora / Bagjata, Basudevpur High Scool ashram Hostel under Sarenga Block, Bankura]
SECTION-A
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall] to light / Fan point as per GS withfollowing average run.
10 Mtr. [ 5(d) /E-9 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the (31*31) cutting channel with electric operated within polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x (1.5 sqmm) [1(b) / E- 9 ] & E-2(5)
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ] & E-2(5)
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ] & E-2(5)
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall
63A DP (Havells / Standard / Hpl)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. (Make: ABB) (2+14) way or eqv make of L&T/Siemens
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32 DP (make: ABB or equivalent make of L&T/Siemens) [ 7 / D- 6]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-ABB ] 32 A Dp
Supply of T5 sensor LED tube 4 Ft. shine bright 240 V, 18 Watt single florescent light fitting for indoor application,complete with all accessories,8 mtr detection range, 50 Hz.
Shine bright 18 W , item code 7000028716. [TATA] or eqv. Make of Philips / Wipro
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Supply of ceiling fans complete with all accessories having the following Model ( Make -Crompton Greaves-High speed /Usha/Orient )
1200 mm Sweep [ NS ]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level( Make by TATA medium)
SECTION B
Solar Module: Supply of MNRE(Ministry of Renewable Energy,Govt. of India)/ IEC approved 300-335 Wp Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA)and high transmissivity 3.2 mm tempered glass, framed in anodized aluminium frame .The power output of individual Lpv modules used in the PV array, under STC, with adequate provision for measurement tolerances. Modules supplied with the Spy system should have certificate as per IEC61215 specification or equivalent National or International standards. Modules must qualify to IEC61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testing asper IEC61701/IS 61701.and having warranty for output wattage, which should not be less than 90%at the end of 10 years and 80%at the end of 25 years. ( Make: TATA/Panasonic/Luminious ) 5000 [WP in ech location]
Supply, delivery & Erection of pre-fabricated M.S. steel structure of pable of extreme weather conditions including wind trust up to 120 KM/Hour with fixing of necessary MS ladder/railing and painting with appropriate weather coats including construction of R.C.C. foundation and all allied works as per approved drawing and direction of the E.I.C. Each structure should have angle of inclination as per the site conditions to take maximum isolation. The mounting structure steel shall be as per latest IS 2062\1992 standard and the galvanization of the mounting structure shall be in compliance of the latest IS for the structural material should be corrossion resistance and electrolytically compatible with the materials used to construct the module frame, including fastener, nuts and bolts. The thickness of the galvanization should be more than 75 Micron.Necessary protecdon towards rusting need to be provided either by coating or anodization.The minimum clearance of the structure from the roof level should be 300 MM. Design to be approved by EIC before fabrication.
Supply testing commissiong of 1 no pv Array Junction Box with A)The junction are to be provided in the SPD WITH IP 65 ENCLOSER AND ACDB WITH SPD AND IP 65 ENCLOSER 32 A MCB ,40 KA ac SPD. And for dcdb 32 A dp mcb and Dc spd. P.C Distribution Panel Board {DPB) shall control ltie AC power kom PCU/ inverter and should have necessary surge errestors. interconnection Tom ACDB to mains at LT Bus bar. Designed for 20 KWP solar power plants with all protections as per MNRE guidelines. DC DPBs shall have sheet form encloser of dust and vermin proof conform to IP 65 protection. The bus bars should be made of Copper of suitable size and of suitable capacity fuse and MCBs / MCCB shall be provided for controlling DC power output, to the PCU along with suitable surge rectors. AC power distribution panel board (DPB) shall control the AC power from PCU/Inverter and should have necessary surge arrestors. Interconnection from SEDB to Mains at LT Bus bar while in grid tied mode. All switches and the circuit breakers connectors should come from to IEC 60947 part 1, 2 and 3. Is 60947 Part 1, 2 and 3. All the panels shall be meta clad totally enclosed rigid floor mounted air insulated cubicle type suitable for operation on 3 phase / single phase 415 or 230 volts. 50 Hz all indor panels will have protection of ip 54 or better. All outdor panels will have protectionof IP65 or better.
ACDB 16 SWG poder coated, Double Door with IP 42/43 protection along with all necessary connection
Power Conditioning Unit : As SPV array produce direct current electricity, It is necessery to convert this direct current into alternating current and adjust the voltage levels to match the grid voltage. Conversion shall be achieved using an electronic inverter and the associated control and protection devices. All these components of the system are termed the " Power Conditioning Unit [ PCU]". In addition , the PCU shall also house MPPT [ Maximum Power Point Tracker] controller. inverter output should be compatible with the grid frequency.This PCU should support Net-metering function with Battery Bank Utility facility. Typical technical features of the inverter should be as follows. 1.Rated AC power:- 230 V, Single Phase, 50Hz 2.Max Supported Panel Power:- 3500Wp 3.Charge Controller:- MPPT 4.Nominal Battery Bank Voltage:- 48 V 5. Rated output power 3 KVA (Make: Panasonic/havells/Growatt )
Supply & Delivery of 150 Ah solar Battery should be provided with Solar Dry cell/Lead Acid Batteries performing with series /parallel operation as suitable for the PCU. The backup should be of minimum 2 hours operation of the whole system for energy storge with the following major specifications --.The battery shall have higher life expectency . Longer cycle life .Low discharge rate & charge faster Certification: The battery should be CPRI approved and certified to meet IS 13369:1992 standard rating. [ Make: Exide. Luminous or any MNRE Approved ]
Power conditioning unit with rated output power 2000VA, with wide input voltage range, (200-240 V ) for optimize performance, advance led display and transformer less GT topology, ethernet with wi-fi (Make: Panasonic/ exide/ microtek )
DC cable 1C*4 Sq mm, 1.1KV grade for Solar (finolex/RR/Polycab )
1.1 Kv grade 3C* 10 Sq mm PVC copper cable (finolex/RR /Polycab)
1.1 Kv grade 3C* 16 Sq mm PVC copper cable (finolex/RR /Polycab)
Earthing kit (Rod, compound, Clamp)
Earthing Cable 1C* 10 Sq mm
Installation Kit, Terminal Ring and pin,MC 4 couplers, ties and all other accessories and Required CIVIL work.
Installation, Testing, commissioning of all above stated solar system and Transportation Charge
SECTION C
Supply and installation by OEM or Authorized channel Partner of OEM, of external, wide area, early steamer emission OPR 30 type lightning arrester made of robust stainless steel & tested Standard stated in French Standard NF C17- 102, and IEC 62305-2. It is capable of polarizing the tip with a voltage of 600V to 10-20kV/m synchronized with an approaching lightning and triggering a powerful upward streamer with speed of 1m/µs into the air, with average time gain of 25 microseconds earlier than naturally formed streamers. Its upward streamers are strong enough to withstand applicable cyclonic wind speeds.The serial number displayed on the ESE lightning arrester shall be duly supported with the "certificate of country of origin" issued indicating the serial number of the product supplied. The ESE terminal must offer protection radius of 48 Mtrs. in Protection Level - I (high protection) and preferably to be mounted on the roof top of the building. ( Make: ABB)
Supply and installation by OEM or Authorized channel Partner of OEM of stainless steel support Mounting Mast 30 mm dia to hold early steamer emission OPR 30, of robust design with guy wire and base plate alongwith all accessories like clamps, shaddles, holding arrangements to fix mast to building structure at highest point such that the air terminal is 5 mtrs above the tallest structure Mounting Mast. (2 Mtrs. and 3 Mtrs. with Guy wire and Base Plate)
Supply and installation of lightning Stroke Counter by OEM or Authorized channel Partner of OEM working electro mechanically without any power supply.The recorder shall be of non-resettable type with the electro-mechanical display. No LCD screen is permittted as it may depend upon the battery life to energize the LCD. The lightning stroke recorder shall be duly tested & certified inline with the ESE lightning arrseter in an international labortaory for an impulse current (8/20 micro sec) and should count lightning strokes of 0.4 Ka to 150 Ka. ( Make ABB )
Supply and Laying of Down Conductor G.I.Strip of 50/6 mm ( length - As per Actual), both Verticle and Horizontal, clamping by saddles not exceeding 500 mm apart with 35/8" screw for fixing in wall complete with full threaded bolts with nuts and double washers incl. mending good damages to building work. Finishing the ends of the above Strip by Nut and Bolts, etc.
Hiring charges for Scaffolding arrangement including dismantling at the end of work and carriage, for ESE OPR 30 LA installation.
Supply and Installation by OEM or Authorized channel Partner of OEM of Medium Pipe (10 ft. long, 2" dia G.I.Pipe along with earth rod and Chemical Gel filled with highly conducting metallic compounds with permenant sealings at both ends - ( Make Standard, ISI Brand )for Earthing and for inter connection of Earthing under ground (of 3 meters X 1nos. per pit) with 3 Earth pits of 10 feet deep each.
Supply and Laying of maintenance free earthing terminal which consist of Ground Resistance Improving Furse Cem Conductive Aggregate material, tested as per BS. 1 bag of 25 kg. per Pit, to make it maintenance free and provide low resistance in the earth terminal to be executed by OEM or Authorized channel Partner of OEM only.
Application process of Net metering from WBSEDCL for solar grid system including net metering charge and new service connection or load enhencement charge upto 6 KW.
15 W Led Street light (two in one), dusk to dawn, 4 hrs 100% rest 50% with automatic charge controller, 75 Wp solar panel and 18 Ah lifepo4 battery in 6 meter hot dip galvanized pole with 1 meter underground with concrete base. (MNRE approved matarial)
SECTION D
Supply of 150mm dia PVC pipes & fittings schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS:1239 (Part-I) standard length of 6 Mtr (Page 13, Item 19(II)A Sanitary & plumbing 2017)
Supply of 150mm Dia PVC strainer of approved make with adater conforming to I.S. 12818 specification . Standard length of 6 Mtr (Page 52, Item 6(IV)A Sanitary & plumbing 2017)
Supply of 150mm Dia Steel cutter piece with socket/CI plug cutter with bottom plug. (Page 53, Item 9 Sanitary & plumbing 2017)
Supplying, fitting and fixing in position 150mm Dia G.I. pipes of TATA make for underground works with all necessary accessories (Page 3, Item 2 Sanitary & plumbing 2017)
Supply, fitting and fixing 150mm Dia G.I. cap at top (Page 54, Item 18 Sanitary & plumbing 2017)
Supply of 32mm Dia PVC pipes & fittimgs schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS:1239 (Part-I). Standard length of 3 Mtr (Page 13, Item 19(III)A Sanitary & plumbing 2017)
Supply of 150mm dia Flange schedule 50 (medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS:1239 (Part-I) (Page 16, Item 19(III)G Sanitary & plumbing 2017)
Packing the angular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2mm to 5mm or the size approved by the E.I.C. including cost of all materials labour and equipment complete. (Page 55, Item 24 Sanitary & plumbing 2017)
Supply of 150mm heavy duty supporting clamp in two halves made of M.S. flat for holding 50mm N.B. Column pipe (Page 07, Item No-30 W.R.D.D. Schedule rates 2018)
Supplying of 50mm NB heavy duty supporting clamps in two halves made of MS flats for holding 80mm NB column pipes (Page 08, Item No-32 W.R.D.D. Schedule rates 2018)
Supply of 50mm Dia galvanised iron socket with I.S.I mark. (Page 103, Item 2 Sanitary & plumbing 2017)
Supply of 50mm Dia long screw (150mm long) (Page 108, Item 12 Sanitary & plumbing 2017)
Supply of 50mm Dia G.I. plain equal elbow of approved brand and make. (Page 105, Item 7 Sanitary & plumbing 2017)
Supplying of 50 mm Dia Medium quality G.I pipe (Page 102, Item 1 Sanitary & plumbing 2017)
Supply of 50 mm Dia G.I. plain tee of approved brand and make (Page 106, Item 8 Sanitary & plumbing 2017)
Supply of 50mm Dia G.I. bend. (Page 105, Item 6 Sanitary & plumbing 2017)
Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 meter for 150mm dia. Tube well with top enlargement of 250mm dia. (upto 50 metre). (i) First 50 metre. (Page 50, Item 2(b)(i) Sanitary & plumbing 2017)
Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 meter for 150mm dia. Tube well with top enlargement of 250mm dia. (upto 50 metre). (ii) Next 50 metre. (Page 50, Item 2(b)(ii) Sanitary & plumbing 2017)
Labour charges for lowering of pipe, strainers, blank pipe etc. and fitting, fixing the same including cutting, threading where necessary complete including bucket washing and other incidental works in this connection. (iii) 150mm dia G.I. Housing pipe. (Page 16, Item No-2 W.R.D.D. Schedule rates 2018)
Washing and developing tube well with air compressor pump and engine for 8(eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. (Page 55, Item 20 Sanitary & plumbing 2017)
Charges of mobilisation of drilling equipments, tools and plants etc. and transportation of departmental materials from sub-divisional store to work site and returning excess departmental materials if any, to sub-divisional store after completion of work. (Page 17, Item No-6 W.R.D.D. Schedule rates 2018)
Supplying & Installation of 1 phase electro motor pump set suitable for solar operation covering 1 years warranty for the following condition including loading-unloading and transportation etc. 1 HP ISI marked 1 phase 230 V pump-motor set having discharge at required head as bellows: (ii) Submersible pump-motor set for LDTW ISI marked as per IS:8304 with flow range of 53-77 m^3/ day at 30-44 mtrs head. (WRIDD solar S/n-9-c-iii dated- 16/07/2018)
Supply, transport, installation of Power Conditioning Unit including MPPT, Data Logger and IP54 enclosed inverter unit qualifying IEC61683- Enviroment standard, safety standard suitable for 1 phase AC motor, IGBT based high voltage switching inverterwith MPPt technology, to take care the variation of sunlight and will be suitably mounted inside the metal encloser. Inverter should have protection against dry run, over current, under current, over voltage, under voltage, short circuit etc. System should be able to run at low sunshine and minimum 7-8 hours a day to run should be possible during normal sunshine condition. Inverter should have option to auto start for any short trip off due to low light/cloudly situation except for dry run. Inverter should be provided with a display to show the various parameters by the user such as voltage, current, solar panel dc voltage, inverter IGBT temperature, output AC voltage, output frequency, pump flow (direct or calculated metod), irradiation etc. The system should be capable to store the data at a set interval and transfer it in a pen drive through USB port. It should also monitor and save total run time total water pumped etc. There for 1 HP capacity motor pump set. (WRIDD solar S/n-4 dated- 16/07/2018)
Supply, transport, installation and commissioning of MNRE/IEC approved solar module of multicrystaline cell with minimum efficiency of 15 % and fill factor more than 70% laminated between sheet of Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass, framed in anodized aluminium frame. The power output of individual PV modules in PV array, under STC, should be minimum 300Wp with adequate provision for tolerances. Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent national or international standard. Modules must qualify to IEC 61730 part I and part II for safety qualification testing and salt mist corrosion testing as per IEC 61701/IS 61701 and having warranty for uotput wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate should be supplied. (c) for1 HP grid system solar water pumping system (with multicrystalline PERC/bifacial spv module - 960/990 Wp with 320/325/330/335 Wp SPV panel.
Supplying, transport, installation of weather proof manual tracking structure made of MS channels, angles and pipes etc. duly IS marked channels and angles (IS 808) to hold SPV module with MS heavy duty pipe not less than 125mm as per IS 1239 and plate of IS 226. Structure like canopy supported with aRCC column to be installed to limit land requirement with a height of placement of panel for free human movement and natural air cooling will be happening to get the maximum efficiency from the modules. This structure should be designed considering all the possible loads on the solar panels and on the structure itself including wind load with basic wind velocity 150 km/hr. The steel structure of suitable size is to be protected with minimum 80 micron galvanization and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be provided to face the sun optimally. The weight of module structure having 6 module structure of 320/325/330/335 Wp SPV panels should not be less that 191 kg. (WRIDD solar S/n-2i dated- 16/07/2018)
Foundation of module mounting structure suitable and stable reinforced cement concrete foundation for dual axis manual tracking SPV module structure as per approved drawing (b) for six module structure having maximum capacity of 1980 Wp. (WRIDD solar S/n-3 dated- 16/07/2018)
Foundation of water tank mounting structure suitable for 2000 lts water tank at 2.5 mtr hight from the base level with table reinforced cement concrete foundation
Supplying, fitting and fixing of UV rated Copper cable laid inside HDPE conduit and other accessories as per following with necessary connection with the solar PV modules, MPPT, etc (i) 4.0 Sq.mm single core multi studs-10 mtrs (minimum), (ii) 6.0 Sq.mm single core multi studs-5 mtrs (minimum), (iii) Lugs, HDPE pipes, flexible pipes, saddle, cable tie etc. For 5 HP per structure. (WRIDD solar S/n-5 dated- 16/07/2018)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of each electrode and filling and ramming and (hot dip) MS flat on wall/floor with GI saddle as requiredand connection to equipments incl. drilling holes with bolts, nuts, washer etc. complete. (WRIDD solar S/n-6 dated- 16/07/2018)
Supplying, fitting and fixing conductor air terminal made 20mm dia 1000mm long GI pipe (ISI medium) having 5nos. Discharge prongs of 4 SWG GI (hot dip) wire at top duly soldered with 7/16 standard GI (hot dip) wire (4 mtr. Long), 20mm dia X 125mm long galvanized bolt, double nut, doublr washer including socketing at both end standard GI (hot dip) wire by crimping sockets/thimbles and S&F 40mm dia GI pipe (ISI medium) protection (3 mtr. long) to be filled with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.65 mtr. (WRIDD solar S/n-8 dated- 16/07/2018)
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 1000 litre capacity (P-37, It-6) with establish on civil construction, consisting earth work in excavation of foundation trenches in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom,(payment to be made on measurement of finished quantity), single BFS, Ordinary cement concrete of 1:1.5:3 ratio with grated stonechips, 125mm thick brick work with 1st class bricks in; cement mortal (1:4), Net cement panning, incl. supplying, fitting and fixing of 80mm dia. PVC pipes of approved make (medium duty) conforming to ASTMD-1785 and complete in all respect as per drawing & direction.
Labour for punching hole in plastic water storage tank upto 50 mm dia. (P-38, It-13)
Labour for hoisting plastic water storage tank (ii) Above 1500 litre upto 5000 litre capacity. (a) Upto 2 nd story from G.L (P-37, It-10)
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). (P- 6, It-7 [a])
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
(e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm
Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)
(a) For Exposed Work PVC Pipes (Dia) 15 mm
Supply of PVC pipes & fittings (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) Socket (Dia) 15 mm
Supply of PVC pipes & fittings (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) Elbow (Dia) 15 mm
Supply of PVC pipes & fittings (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) Tee (Dia) 15 mm
Best quality sink in mosaic in silver grey colourwith C.P. waste and other fittings, rubber plug and chain, C.I. heavy brackets with two coats of approved paint. (i) 600 mm X 450 mm X 200 mm
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (iv) 50 mm dia (P-4 , It-4)
Supplying fitting fixing fabricated GI Kiosk Box one side openable of size 1000mm X 600mm X 650mm mounted by 4 nos legs and frame made of GI angle 65 X 65 X 6mm. All sides are cover with 3mm GI sheet on the frane of GI angle 25 X 25 X 3mm with back side cover made of 1.5mm thick GI sheet and providing GI channel door made of 25 X 25 X 3mm GI channel inside the box for fitting the electrical equipment with locking arrangement.
Testing and commissioning of the scheme after completion of all works. (WRIDD solar S/n-10 dated- 16/07/2018)
Display board of the work as per E.I.C. incharge.
SECTION E
SITC of Automatic RO water purifier Machine with Uv protection and TDS controller on wall has a high purification capacity of 80-100 L/hr , Max duty cycle per day 500 LPD with filter change alarm for enhanced safety, Durable Stainless steel body. Dimension[ 505(L)*360 (W)*746(H)] code 11079 (Make: Kent/Bluestar/Aquaguard)
SITC of Automatic Water cooling machine of double tap (One for normal water other for cold water) of 40 liter capacity. Make: Blue Star
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand: Polycab/Finolex/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. nency fittings as required
i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Supply & Fixing 240 V, 16A, 3 pin Modular type plug socket, 16A Modular type switch, without plug top, 16A switch type SP MCB on 4 Module GI Modular type switch board with 4 Module top cover plate (Brand approved by EIC) flushed in wall incl. S & F switch board and top cover plate and making necessary connections as required
Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc. including supplying sockets, tapes.
Shed and protection cell by fabricated G.I. angle strips with net covering and shed over the top with sheet
After complition of project vendor should provide one years of solar grid system(5 KW)/solar submarsible maintanance or menufacturer ensure product warranty for same.
SECTION F
Supply, installation, Testing & commissioning of Microprocessor based addressable type fire alarm control panel with LCD display with network card.The Fire Alarm Panel shall have Minimum 1 loop and expantion capacity of two loop, with relay controls. The PANEL shall be able to generate History Events. The panel should be capable to acknowledge, singnal silence and reset function of event. The Panel shall have provision for Alarm,Trouble relay and Modbus/Bacnet/Lanworks. The Panel should have UL/EN ( Approved Makes:GST/Notofire/Ravel/Mircom/Secutron).
Supply, installation, Testing & commissioning of Addressable multicriteria (capable to detect smoke and heat) detector with base, with LED indication. UL/EN approved make. ( Approved Makes:GST/Notofire/Ravel/Mircom/Secutron).
Addressable Manual call point for manual Fire signaling UL/EN approved.( Approved Makes:GST/Notofire/Ravel/Mircom/Secutron).
Addressable Combined Sounder and Strobe with programmable alarm tones and with require modules. UL/EN approved. ( Approved Makes:GST/Notofire/Ravel/Mircom/Secutron).
Supply, Installation, Testing & commissioning of Isolator module for emergency loop circuit isolation in case pf any type short circuit in loop. Product should be UL/EN approved. ( Approved Makes:GST/Notofire/Ravel/Mircom/Secutron).
25 mm PVC conduits in following sizes including cost of junction boxes, bends, elbows sockets, tees etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware. Approve Make : AKG/Precision/Norpak/Primco Plast.
2Cx 1.5 Sq. mm Twisted copper FRLS , Cable fixed on the surface/through conduit of the building structure complete with termination and testing as per requirement. Approve Make : POLYCAB/HEMFLEX/MESCAB/KEI/Finolex/Amppere.
4 Kg ABC type Fire extinguisher ISI brand Flamen/Fyrex/Safex/Minimax.
Fire extinguishing Ball with Mount Make AFO/Fyrex/Cease Fire
Supply and installation of 4.5Kg CO2 type Fire extinguisher ISI brand Flamen/Fyrex/Safex/One Top/Fireshield/Zenith/Sealfire.
Supply and installation of 5 Kg ABC Moduler type Fire extinguisher ISI brand Flamen/Fyrex/Safex/One Top/Fireshield/Zenith/Sealfire.
SITC of LED type Single side view Fire Exit Sinage with dimention 300x180x25 man running icon. Approved Make: Prolite/Asses Security/Fyrex.
Supply , installation , testing and commissioning of Compact Indoor type wall mount Loudspeaker for Fire Emergency Voice Evacuation: 2.25" twiddler driver or Better, Free field Frequency range (-10dB) of 80Hz to 16kHz; Power handling of 64 Watt peak; Nominal dispersion of 170x160; Free field Sensitivity of 84 dB SPL and Max SPL of 103 dB SPL peak; Nominal Impedance 8 Ohms; Integral multi-tap Transformer with tap settings of 2/4/8/16/20 W @ 100V. with Powder-coated steel grille; Brackets with pitch/yaw adjustment included..Approve Make :EAW/Mayer Sound/Bose
Supply,Installtion,testing & Commissioning of Gooseneck Microphone for Fire Emergency Voice Evacuation Display on Transmitter and Receiver , RF Power output 30mW or Better , Polar Pattern :- Cardiod/Supercardioid or better , Carrier frequency range 500Mhz to 865Mhz , Frequency response 20Hz to 20Khz , Mute Button on Transmitter , Battery Operation time Minimum 8hr , Should have Charging Contact in Transmitter , Receiver, switching bandwidth Minimum 40Mhz Or better, Complete Set complete as required as per tender specifications. Approved Makes: Beyerdynamic /Shure/Studio Master/Equivalent Reputated
Supply , installation , testing and commissioning of Audio mixer with 6x Combo XLR-1/4" inputs 4x Aux inputs 2x Aux sends with Phantom Power. TRS stereo outputs Dedicated headphone output USB A and B for playback or PC.Approve Make :Midas/Allen & Heath/Bose/Studio Master
Supply and installation of Floor mount Rack 8U 600mm x 800mm with fan 2Nos,Tray- 03 Nos. 5/15 Amp power mangement 2 Nos.Lockable front and back door. Valrack/WBOX/Massrack.
Supply and Laying of 80 0.20 mm x 2 Core ATC Copper cable.Approve Make :Krystal/Belden/Molex/Liberty AV
SITC of Horizontal Single mounting Siren, Single Phase 220/250V, 6000 RPM 50 C/s AC/DC Approved Make: Kheraj or equivalent.
Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
25 mm PVC conduits in following sizes including cost of junction boxes, bends, elbows sockets, tees etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware. Approve Make : AKG/Precision/Norpak/Primco Plast.
SITC of Bullet Camera with 1/2.8" Progressive CMOS, ICR, Color: 0.01 Lux @(F1.2, AGC ON), 0lux with IR, 1920x1080:25fps(P)/30fps(N), H.265/H.264/MJPEG, Three Streams, 3D DNR, ROI, DWDR, BLC, HLC, IR range: up to 40m, Fixed lens 2.8mm/4mm, Motion Detection, Line crossing detection, Intrusion detection, Motion Detection. DC12V & PoE; IP67; UL, CE, FCC, BIS, ONVIF Certified. Approved Make:Prama/AlconLink/Pelco/Robotix.
SITC of Dome camera with 1/2.8" Progressive CMOS, ICR, Color: 0.01 Lux @(F1.2, AGC ON), 0lux with IR, 1920x1080:25fps(P)/30fps(N), H.265/H.264/MJPEG, Three Streams, 3D DNR, ROI, DWDR, BLC, HLC, IR range: up to 40m, Fixed lens 2.8mm/4mm, Motion Detection, Line crossing detection, Intrusion detection, Motion Detection. DC12V & PoE; IP67 & IK10; UL, CE, FCC, BIS, ONVIF Certified.Approved Make:Prama/AlconLink/Pelco/Robotix.
Up to 32-ch IP video input; 160Mbps Incoming & 256Mbps Outgoing Bandwidth; 4-SATA Interfaces for HDD (Support upto 8TB in each slot); Alarm interface I/O: 16/4; 1.5U case,19"; ANPR camera support, Recording Resolution Upto 12 Mega Pixel; 2x Ethernet interface 10/100/1000M; RS485; Support H.265 and H. 264; 4K-HDMI & 1080P-VGA Display output resolution. Power Supply 100 to 240 VAC; UL, CE, FCC, BIS, ONVIF Certified.Approved Make:Prama/AlconLink/Pelco/Robotix.
SITC of 8 Port POE switch with POE150s adaptor IEE802.3af complient , up to 100 mtr., gigabit 10/100/1000. Approved Make:Dlink/TPLink/Digilink/WBOX.
SITC of 8 Port Gigabyte uplink switch for NVR gigabit 10/100/1000.Approved Make:Netgear/Dlink/TPLink/Digilink/WBOX or eqivalent reputated brand.
SITC of Colour 33" HD Monitor for display. Make: LG/Phillips/MI/AOC.
SITC of 2U rack for camera switch. Approved Make: Valrack/WBOX/Dlink.
SITC of 6U rack for NVR and switch. Approved Make: Valrack/WBOX/Dlink.
SITC of 1 KVA offline UPS. Approved Make: APC/Microtek/Vertiv.
SITC of Cat6 cable (305 mtr.)with accessories. Approved make: 3C3/D-link/DGLink/WBOX.
PART-B [LOCATION : Nivedita S.C Central Girls Hostel , Natunchati, Bankura]
SECTION-A
SITC of Automatic RO water purifier Machine with Uv protection and TDS controller on wall has a high purification capacity of 80-100 L/hr , Max duty cycle per day 500 LPD with filter change alarm for enhanced safety, Durable Stainless steel body. Dimension[ 505(L)*360 (W)*746(H)] code 11079 (Make: Kent/Aquaguard/LG)
SITC of Automatic Water cooling machine of double tap (One for normal water other for cold water) of 40 liter capacity. Make: Blue Star
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand: Polycab/Finolex/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. nency fittings as required
i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Supply & Fixing 240 V, 16A, 3 pin Modular type plug socket, 16A Modular type switch, without plug top, 16A switch type SP MCB on 4 Module GI Modular type switch board with 4 Module top cover plate (Brand approved by EIC) flushed in wall incl. S & F switch board and top cover plate and making necessary connections as required
Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc. including supplying sockets, tapes.
Shed and protection cell by fabricated G.I. angle strips with net covering and shed over the top with sheet
SECTION B
SITC of Automatic Sanitary Napkin Vending Machine on wall has a capacity of 100 nos pads (230V, 50Hz), having 1.2mm thick powder coated MS enclosure (23*6*31 inch) H*W*L of AVM100 weight approx 18kg. Coin accepted INR 1, 2 & 5 (customisable)
SITC of Automatic Sanitary Napkin Incinerator/Dispoal Machine on wall has a capacity ranging from 100 to 250 nos pads; capacity/cycle: 7-8 pads (230V, 50Hz electric supply), having 1.2mm thick CRCA steel enclosure (16*8.5*10 inch) H*W*L of INC100 weight approx 10kg. Internal housing: 4mm insulation, auto cut-off system with MCB protection, Heater:1000 watt, insulated magnetic doors with total air tight cabinets, Smoke outlet: Top by steel pipe 1.2m comes free with the machine
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand: Polycab/Finolex/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. nency fittings as required
i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Supply & Fixing 240 V, 16A, 3 pin Modular type plug socket, 16A Modular type switch, without plug top, 16A switch type SP MCB on 4 Module GI Modular type switch board with 4 Module top cover plate (Brand approved by EIC) flushed in wall incl. S & F switch board and top cover plate and making necessary connections as required
Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc. including supplying sockets, tapes.
Supply of leak proof M/L/XL/ extra large super hygine sanitary napkin with fast absorvance.( whisper,stayfree,go girl,nine,Pari)
UJJWAL MUKHERJEE (BID ID -6647984)
TAPAN KUMAR SARKAR (BID ID -6648012)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .