| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical As per CEO order |
| 2 | Accepted-Technical | Accepted-Technical As per CEO order |
| 3 | Accepted-Technical | Accepted-Technical As per CEO order |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹17.6 L
EMD Value
₹35,122
Closing Date
17 Feb 2026, 3:00 pmClosed
CEO Shahjahanpur
Office of the Cantonment Board Shahjahanpur
CONSTRUCTION OF SHOPS ON VACANT SPACE ADJACENT TO EXISTING SHOPS NEAR HEAD POST OFFICE AT GLR SY NO. 152 (PART).
2026_DGDE_895275_1
48/works/BandR/shops and water point/2025-26
Open Tender
Civil Works - Buildings
Item Rate
365 days
Shahjahanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
CEO Shahjahanpur
₹35,122
21 Feb 2026
24 Jan 2026
18 Feb 2026
24 Jan 2026
17 Feb 2026
24 Jan 2026
Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) in Laid dry or laid dry and pointed complete all specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out of Soft/loose soil complete all specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick of Soft/loose soil complete all specified and directed.
Spreading and levelling in layers n exc. 25 cm thick of remaining at Soft/loose soil complete all specified and directed.
M&L for anti-termite treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I
M&L for anti-termite treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all specified and directed by E/I
M&L for anti-termite treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all specified and directed by E/I
M&L for anti-termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I
M & L Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate)
M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in foundation / footing, plinth beam etc. excluding steel reinforcement and formwork complete all specified and directed.
M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves excluding steel reinforcement and formwork complete all specified and directed.
M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Beams, cantilevers, bressummers, lintels over 1.5m span excluding steel reinforcement and formwork complete all specified and directed.
M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Columns, pillars, piers, posts and struts excluding steel reinforcement and formwork complete all specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all specified and directed
M&L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished surface fair and even complete all specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) finished surface fair and even complete all specified and directed.
M&L Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) finished surface fair and even complete all specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished surface fair and even complete all specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. finished surface fair and even complete all specified and directed.
M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1:6 complete all specified and directed.
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
M&L for 12mm thick cement plastring in 1:6 cement motar on fair faces of brick work or concrete surface finished even and smooth without using extra cement on surface complete all specified and directed.
M&L for 3mm thick wall care putty on ceiling
M&L for Screed bed or bedding layer of mortar 15 mm thick Cement plaster with 1:4 mortar for laying floor finishes complete all specified and directed.
M&L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for c.c. flooring complete all specified and directed.
M&L for Machine cut kota stone slab flooring 40-50mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all specified and directed.
M&L two coat synthetic enamel paint preparation of over steel surface.
3 mm thick wall care putty on wall
M&L two coat oil bound distemper and preparation of newly plastered surface of wall for internal side ceiling complete all specified and directed by E/I. MAKE- APEX
M&L for cement paint i.e. two coat of exterior emulson paint and preparation of newly plastered surface outside complete all specified and directed by E/I.
Supplied and fixed with thickness of laths in 1.25mm thick of Steel rolling shutters, without ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all specified and directed.
S&F Ball bearing for rolling shutters
M&L for 75 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for c.c. flooring complete all specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
M&L for point writing for one light/fan point, 3/5 pin socket outlet independent/bell or buzzer point/telephone point controlled by one switch with cable 1.5 Sqm size PVC suface conduit nsulated (unsheathed) 1100 Volts grade single core staded (multistred) copper conductor FRLS cable as per IS-694 and drawing in and including IVC suitable conduct medium grade not less than 20mm dia and sunk cast iron terminal boxes for mounting fittings, light switches, sockets with 3mm thick Bakelite laminated sheet with brass screws and cup washers including one continuous run of 1 Sqmm nominal area PVC insulated unsheathed 100 Volts grade signle core FR cable conform to IS-694 with stranded copper conductor (multistranded) green colour earth wire and connecting to earth dolly complete all as specified and directed.-make of havells, fenolex, pllaza
M&L for point writing for one light/fan point, 3/5 pin socket outlet independent/bell or buzzer point/telephone point controlled by one switch with cable 2.5 Sqm size PVC suface conduit nsulated (unsheathed) 1100 Volts grade single core staded (multistred) copper conductor FRLS cable as per IS-694 and drawing in and including IVC suitable conduct medium grade not less than 20mm dia and sunk cast iron terminal boxes for mounting fittings, light switches, sockets with 3mm thick Bakelite laminated sheet with brass screws and cup washers including one continuous run of 1 Sqmm nominal area PVC insulated unsheathed 100 Volts grade signle core FR cable conform to IS-694 with stranded copper conductor (multistranded) green colour earth wire and connecting to earth dolly complete all as specified and directed.-make of havells, fenolex, pllaza
Supply and fixing modular switch one way 6 Amps complete all as specified and directed.
Supply and fixing switch socket outlet 3 pin 5 Amps flush type complete all as specified and directed.
Supply and fixing switch socket outlet combined multipurpose 6 pin, 16 Amps 3 module complete all as specified and directed.
S&F lamp holder insulated body with back plate 5 Amps suitable for batten fittings (angle plain) complete all as specified and directed.
S&F Single pole & neutral1, 4 way DB enclose double door complete all as specified and directed. MCB 5 to 30 Amp single phase 12 Nos DP single phase 40Amp 3 Nos- make- HAVELLS
Supply and fixing ceiling fan regulator electronic type 5 stage speed variation ISI marked complete all as specified and directed..
Supply & Fixing single pole MCB 10 to 40 amp. complete all as specified and directed.
Supply & Fixing isolator Double pole 40 amp.complete all as specified and directed..
Supplying and fixing 1100 volts grade heavy duty, 10 Sqmm 2 core cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mater aprt including 4mm dia, GI suspensions wire, two single core cable falt or circular complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_941016.xls
BOQ • 0.26 MB
TENDOC.pdf
Tender Documents • 11.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .