Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹45.7 L+₹1.8 L (4.20%)Rejected-Finance SUBHASINI TEA ESTATE HASIMARA PS JAIGOAN DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.0 L+₹3.1 L (7.09%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹48.1 L+₹4.3 L (9.73%)Rejected-Finance SURJANAGAR ALIPURDUAR | ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 736121 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹50.2 L+₹6.3 L (14.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
17 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
REPAIR/MAINT OF STORM WATER DRAINS INCLUDING REPLACING OF DAMAGED BRICK, REPAIR/MAINT OF FOOTPATHS, HARD STANDING, APPROACH PATHS AND OTHER ITEMS IN OMQ AREA, REPAIR/MAINT OF FOOTPATHS, HARD STANDING, APPROACH PATHS AND OTHER ITEMS IN ARJAN AREA AND
2024_MES_662101_1
C/8766/2024-25/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹89,000
Yes
3 Sept 2024
26 Jun 2024
19 Jul 2024
26 Jun 2024
17 Jul 2024
10 Jul 2024
Amount
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) laid dry or pointed, complete all as specified and directed.
M&L for brick work with, sub class 'B' bricks, old size, laid flat and bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) in drains, channels, kerbs etc, complete all as specified and directed.
All as per item No 2.00 here-in before but except bricks, complete all as specified and as directed. Note-(i) Bricks obtained from demolition shall be re-used. (ii) The quoted rate shall deemed to be included for cleaning of old bricks obtained from demolition.
M&L for brick work with, sub class 'B' bricks, old size, laid on edge and bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) in drains, channels, kerbs etc, complete all as specified and as directed.
All as per item No 4.00 here-in before but except bricks, complete all as specified and as directed. Note-(i) Bricks obtained from demolition shall be re-used. (ii) The quoted rate shall deemed to be included for cleaning of old bricks obtained from demolition.
M&L for racking out joints/pointing to brick work or brick tiles laid flat, in floors, surface channels, roofs, etc in cement mortar and flush pointing to bricks laid flat or brick tiles in paving in cement mortar (1:4), complete all as specified and directed.
M&L for racking out joints/pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc and flush pointing to brick on edge paving in cement mortar (1:4), complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, manholes etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified and directed.
M&L for PCC (1:2:4), type B-1. (using 20mm graded crushed stone aggregate) as in benching, coping, bed plate, lintel upto 1.5m span cast, in situ including necessary form work, complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
M&L 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces finished surfaces of wall, fair and even, complete all as specified and directed.
Demolition of un-reinforced cement concrete of any description not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
M&L PCC (1:3:6) type C1 (using 40mm graded crushed stone aggregate) as in surface chanel, drains etc., complete all as specified and directed.
M & L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds, mitred/stopped ends etc, complete all as specified and as directed
Add or deduct from item No. 16.00 here-in-before for each 25mm girth or part thereof over or under 30cm girth, complete all as specified and as directed
M & L for PCC (1:3:6), type C 2, (using 40mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300mm bore RCC pipe, complete all as specified and directed.
S&F 300mm bore reinforced concrete pipes, class NP2 laid and jointed complete with collar including demolition and breaking up old unserviceable drain pipe including hunching, of any description, complete all as specified and directed.
M & L 75mm thick PCC (1:3:6), type C-2, (using 40mm graded crushed stone aggregate) as in path, drain sides, plinth protections etc.finishing cement concrete surface even and smooth without using extra cement , complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position, disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. (Note:- Reinforcement shall be cut as required to facilitate demolition.)
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, endings and similar work not exceeding 200mm thick (horizontal of sloping) for flat rough finished surfaces of concrete,complete all as specified and directed.
M&L for RCC (1:1.5:3) type A-1, (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like,complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
M&L for pre-cast RCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in cover slab of drain, manholes etc and set in cement mortar (1:4) including necessary form, moulds, etc, complete all as specified and directed. (Note : Reinforcement shall bemeasured and paid separately)
S & F mild steel TMT bars 10mm dia (Grade Fe-500D), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 6mm to 8mm dia (Grade Fe-500D), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed.
M & L 75mm thick PCC (1:4:8), type D 2 (using 40mm graded crushed stone aggregate) as in sub base to floor etc. including necessary formwork, complete all as specified and directed.
Dismantling of floor, hearth or wall tiles including cement mortar bedding (but not backing) and remvoing rubbish off the premishes, complete all as specified and directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25cm thick set jointed and pointed in near cement slurry with pigment in floors over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed
M&L for 60mm thick machine pressed precast concrete coloured interlocking paver block, any shape and size, fixed with grey cement and pigment confirming to IS 15658-2006, M-35 grade, complete all as specified and directed.
M&L for sand filling under floors or in foundations or below paver block etc. including watering and consolidation, complete all as specified and directed. ( Note : Consolidation thickness shall be measured for payment.)
M&L for 100mm thick PCC (1:2:4) type B-2 (using 20mm graded crushed stone aggregate) as in sub-base, path etc including necessary formwork,complete as specified and directed.
M&L for PCC (1:2:4) type B-0, (using 12.5mm graded crushed stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed.
M&L for forming 65mm deep x 10mm wide cantraction (dummy) joints filled with sealing compound, Grdae 'B',complete as specified and directed.
M&L for forming 30mm deep x 10mm wide construction joints filled with sealing compound, Grdae 'B',complete as specified and directed.
Supplying, installing, testing and commissioning of outdoor type LT feeder piller box made out of 3.0mm thick CRCA sheet out door type, CPRI approved, totally enclosed weather dust and vermin proof as per IS with front and rear, with bus bar 500 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron, grouted at floor above 30cm from ground level including PCC, (1:3:6) in foundation comprising with the following accessories including taking down old unserviceble LT feeder piller box , complete all as specified and directed. BUS BAR CHAMBER:- (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 500 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification. INCOMER (i) MCCB 4 pole of capacity 250 Amps with breaking capacity of 36 KA-01 No. INDICATING DEVICES (i) LED Indicating lamps for Main Supply indicating R', Y' B' (set of three) (ii) Digital multi function meter 0-500 volt (iii) LED Indicating lamps - 03 Nos (iv) CT's 500/5 Amp - Set of three OUTGOING FEEDERS (i) MCCB 4 pole of capacity 125 Amps with breaking capacity of 16 KA-01 No. (ii) MCCB 4 pole of capacity 63 Amps with breaking capacity of 16 KA -05 Nos. (Note: Unit quoted rate shall deemed to be included necessary internal wiring for meters, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals, connecting bus bar to MCCB/MCB connections.)
Supplying, installing, testing and commissioning of outdoor type LT feeder piller box made out of 3.0mm thick CRCA sheet out door type, CPRI approved ,totally enclosed weather dust and vermin proof as per IS with front and rear, with bus bar 400 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron, grouted at floor above 30cm from ground level including PCC, (1:3:6) in foundation comprising with the following accessories including taking down old unserviceble LT feeder piller box , complete all as specified and directed. BUS BAR CHAMBER:- (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification. INCOMER (i) MCCB 4 pole of capacity 200 Amps with breaking capacity of 36 KA-01 No. INDICATING DEVICES (i) LED Indicating lamps for Main Supply indicating R', Y' B' (set of three) (ii) Digital multi function meter 0-500 volt (iii) LED Indicating lamps - 03 Nos (iv) CT's 500/5 Amp - Set of three OUTGOING FEEDERS (i) MCCB 4 pole of capacity 160 Amps with breaking capacity of 25 KA-01 No. (ii) MCB SPN 4 pole of capacity 32 Amps 'C' series, with breaking capacity of 10 KA -13 Nos. (Note: Unit quoted rate shall deemed to be included necessary internal wiring for meters, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals, connecting bus bar to MCCB/MCB connections.)
Supplying, installing, testing and commissioning of outdoor type LT feeder piller box made out of 3.0mm thick CRCA sheet out door type, CPRI approved ,totally enclosed weather dust and vermin proof as per IS with front and rear, with bus bar 400 Amps capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron, grouted at floor above 30cm from ground level including PCC, (1:3:6) in foundation comprising with the following accessories including taking down old unserviceble LT feeder piller box , complete all as specified and directed. BUS BAR CHAMBER:- (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification. INCOMER (i) MCCB of 4 pole of capacity 160 Amps with breaking capacity of 36 KA-01 No. INDICATING DEVICES (i) LED Indicating lamps for Main Supply indicating R', Y' B' (set of three) (ii) Digital multi function meter 0-500 volt (iii) LED Indicating lamps - 03 Nos (iv) CT's 500/5 Amp - Set of three OUTGOING FEEDERS (i) MCCB 4 pole of capacity 125 Amps with breaking capacity of 25 KA-01 No. (ii) MCB SPN 4 pole of capacity 32 Amps 'C' series, with breaking capacity of 10 KA -13 Nos. (Note: Unit quoted rate shall deemed to be included necessary internal wiring for meters, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals, connecting bus bar to MCCB/MCB connections.)
Supplying, installing, testing and commissioning of outdoor type LT feeder piller box made out of 3.0mm thick CRCA sheet out door type, CPRI approved ,totally enclosed weather dust and vermin proof as per IS with front and rear, with bus bar 250 Amps capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron, grouted at floor above 30cm from ground level including PCC, (1:3:6) in foundation comprising with the following accessories including taking down old unserviceble LT feeder piller box , complete all as specified and directed. BUS BAR CHAMBER:- (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 250 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification. INCOMER (i) MCCB 4 pole of capacity 125 Amps with breaking capacity of 36 KA-01 No. INDICATING DEVICES (i) LED Indicating lamps for Main Supply indicating R', Y' B' (set of three) (ii) Digital multi function meter 0-500 volt (iii) LED Indicating lamps - 03 Nos (iv) CT's 500/5 Amp - Set of three OUTGOING FEEDERS (ii) MCB SPN 4 pole of capacity 32 Amps 'C' series with breaking capacity of 10 KA -14 Nos. (Note: Unit quoted rate shall deemed to be included necessary internal wiring for meters, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals, connecting bus bar to MCCB/MCB connections.)
M&L straight through joints (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 16 to 35 Sqmm 3.5 core and testing, complete all as specefied and directed.
All as per itme No 41.00 here-in-before but cross sectional area 50 to 70 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 41.00 here-in-before but cross sectional area 95 to 120 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 41.00 here-in-before but cross sectional area 240 to 300 Sqmm 3.5 core, complete all as specified and directed.
M & L for cleaning the LT feeder piller box indoor/out door type of size up to 3.0m x 3.0m x 0.5m of different rating bus bar, after dismatling the incomming and out going connections from MCCB/bus bar and replacing with and including old unserviceble nut, bolts, supporting insulators etc and checking the servicebility of MCB/MCCB, earth continuity conductor, tightning the earth conductor, incomming and out going cables and removing existing old insulation of bus bar and MCCB/MCB terminals, providing new insulation tape of standard quality, applied to bus bar and MCCB terminals and cleaning the feeder piller box, complete all as specified and directed. Note : Contactor have to take the shut down of LT panel before starting the job and switch on the panel after completion of work.
S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15cm size, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core including taking down old unserviceable UG cable of any description, complete all as specified and directed.
All as per itme No 47.00 here-in-before but 120 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 47.00 here-in-before but 70 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 47.00 here-in-before but 25 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 47.00 here-in-before but 16 Sqmm 4 core, complete all as specified and directed.
M&L for lifting, and relaying the existing PVC/XLPE insulated, armoured, heavy duty electric cable with aluminimum conductor, 1100 Volts grade, in trenches/fixed on wall for cross- sectional area of cable of size from 300 Sqmm to 400 Sqmm 3.5 core, complete all as specified and directed. Note: (i) Necessary excavation and earth work shall be measured and paid separately. (ii) Unit quoted rate shall deemed to be included the cost of lugs of suitable size and cable gland irespective of length of cable etc .
All as per itme No 52.00 here-in-before but 185 Sqmm to 240 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 52.00 here-in-before but 70 Sqmm to 120 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 52.00 here-in-before but 35 Sqmm to 50 Sqmm 3.5 core, complete all as specified and directed.
All as per itme No 52.00 here-in-before but 16 Sqmm to 25 Sqmm 3.5/4 core, complete all as specified and directed.
All as per itme No 52.00 here-in-before but 10 Sqmm to 16 Sqmm 2core, complete all as specified and directed.
Supply and laying in trenches/fixed on wall 80mm bore GI tubing, light grade, with necessary fittings such as bend, tee, elbow etc for protection of LT UG cable including taking up/down old unserviceable GI tubing, complete all as specified and directed.
Supply and laying in trenches/fixed on wall 50mm bore GI tubing, light grade, with necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable including taking up/down old unserviceable GI tubing, complete all as specified and directed.
Supply and laying in trenches/fixed on wall 40mm bore GI tubing, light grade, with necessary fittings such as bend, tee, elbow etc complete for protection of LT UG cable including taking up/down old unserviceable GI tubing, complete all as specified and directed.
Supply and laying in trenches or fixed to wall double walled corrugated (DWC) HDPE duct pipe of 50mm dia conforming to IS, approved colour complete with fittings for cable protection including taking up/down old unserviceable pipe, complete all as specified and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation etc. or for shaft, wells, cesspits, manhole, pair house etc. n. exc. 10 Sqm on plan and getting out in any type of soil, complete all as specified and directed.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Supply and laying well burnt sub class 'B' bricks, old size, laid in trenches perpendicular to UG cable, laid flat, (width of brick along the length of cable) over sand cushioning for cable protection, complete all as specified and directed.
Laying only old bricks, sub class 'B' laid in treches perpendicular to UG cable, laid flat, (width of brick along the length of cable) over sand cushioning for cable protection, complete all as specified and as directed. (Note : Old serviceable bricks obtained during taking out of old UG cable shall be re-used)
Supply, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15cm above the cable punned down to 18cm for under ground cable, complete all as specified and directed. (Note : Punned thickness shall be measured for payment)
S&F water proof junction box made from SMC sheet ready made of size 350 x 270 x 200mm with aluminium bus bar of 150 Amp capacity for RYB and neutral fixed inside the junction box with necessary supporting insulators fixed on hylem sheet/insulating sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole/wall with MS clamp 25 x 5mm and nuts & bolts and connecting cables from junction box to fittings including dismantling of old junction box of any size, complete all as specified and directed.
All as per itme No. 68.00 here-in-before but of size 400 x 300 x 190mm and aluminium bus bar of capacity 200 Amps, complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles, etc. including necessary formwork (as required), complete all as specified and directed.
Horizontal boring under the road (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized strip of size 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-I with 50mm thick Pre-cast RCC (1:2:4) type B-I cover slab (reinforced with 8mm dia deformed bar @ 15cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including taking down old unserviceable earthing of any description, complete all as specified and directed. Note : Proper earthing pit should be provided with pit cover.
S&F in repair MCCB 415 volt of capacity 63 Amps 4 pole 16 KA with thermal magnetic protection unit, complete all as specified and directed.
S&F in repair MCCB 415 volt of capacity 100 Amps 4 pole 16 KA with thermal magnetic protection unit, complete all as specified and directed.
S&F in repair MCCB 415 volt of capacity 125 Amps 4 pole 16 KA with thermal magnetic protection unit, complete all as specified and directed.
S&F in repair MCCB 415 volt of capacity 160 Amps 4 pole 25 KA with thermal magnetic protection unit, complete all as specified and directed.
S&F in repair MCCB 415 volt of capacity 200 Amps 4 pole 25 KA with thermal magnetic protection unit, complete all as specified and directed.
S&F in repair MCCB 415 volt of capacity 250 Amps 4 pole 36 KA with thermal magnetic protection unit, complete all as specified and directed.
S&F in repair MCCB 415 volt of capacity 400 Amps 4 pole 36 KA with thermal magnetic protection unit, complete all as specified and directed.
Note: An amount of Rs.38,184.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S. VINITA CONSTRUCTION
M/S ANIL KUMAR BAUL
SHRI SURAJIT SIKDER
MAA TARA TRADING
M/S ANNI ENTERPRISE
MAJUMDER ENTERPRISE
M/S MANODEEP CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .