| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L1 | Accepted-AOC Found lowest and reasonable and accepted | |
| 2 | L2₹21.6 L+₹2.7 L (14.5%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹22.6 L+₹3.7 L (19.9%)Rejected-Finance VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-Finance In order but L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U) E/M Meerut
ROORKEE ROAD MEERUT CANTT
REPAIR AND MAINT OF AC PLANTS OF MH AT AGE E/M (ES) UNDER GE (U) E/M MEERUT CANTT
2023_MES_591915_2
8504/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
Meerut
Please refer tender documents
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut
₹50,000
Yes
1 Aug 2023
20 May 2023
21 Jun 2023
20 May 2023
19 Jun 2023
30 May 2023
Amount
Supply and fix ( in repairs) miniature circuit breakers TPN , 10Amps to 63 Amps , 415 Volts ,50 hz, 16 KA, 'C' curve rating complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Supply and fix ( in repairs) miniature circuit breakers TPN , 6 Amps to 32 Amps , 415 Volts ,50 hz, 16 KA, 'C' curve rating complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Supply and fix (in repairs), stranded copper conductor single core wire 1.5 sqmm, PVC insulated and PVC sheathed, FR , 1100 Volts ISI-694 marked and making connections complete all as specified and directed.
Supply and fix (in repairs), stranded copper conductor single core wire 6 sqmm, PVC insulated and PVC sheathed, FR , 1100 Volts ISI-694 marked and making connections complete all as specified and directed.
Renewal of electonic timer type ET-100 /ST-100 suitable for 240 Volts, 3-30 seconds complete all as specified.
Supply and fix in repairs MCCB, TPN, 100 Amps, 25KA, Icu=100%Ics 415 volts, 50 hz, AC , with Adjustable Thermal release (0.7 to 1.0 In), Fixed magnetic type suitable release for 10.0 In duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
Supply and fix in repairs MCCB, TPN, 250 Amps, 25KA, Icu=100%Ics 415 volts, 50 hz, AC , with Adjustable Thermal release (0.7 to 1.0 In), Fixed magnetic type suitable release for 10.0 In duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
Supply and fix (in repairs) MCCB, TPN, 400 Amps, 25KA, Icu=100%Ics 415 volts, 50 hz, AC, with Adjustable Thermal release (0.7 to 1.0 In), Fixed magnetic type suitable release for 10.0 In duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
Renewal of Single Phase Preventer VSP-2 / VSP-3/ VSP D-2 type, 415 V, TP, auto reset 40/50 Volts all as specified and directed by EIC .
Renewal of Oil pressure gauge with adapter, 100mm dia , 0 to 1 kg vaccuum and 0 to 12.50Kg pressure complete all as specified and directed.
Renewal of discharge gauge 100mm dia , 0 to 1 kg vaccuum and 0 to 25 Kg pressure complete all as specified and directed.
Renewal / Topping of non freezing compressor oil ZR68/72 in factory sealed containers in standard packings as directed.
Renewal of ball bearing No. 6203 for electric induction motor of 2 HP to 5HP capacity complete all as specified and directed.
Renewal of ball bearing No. 6205 for electric induction motor of 7.5 HP to 15 HP capacity complete all as specified and directed.
Renewal of ball bearing No. 6311 for electric induction motor of 20 HP to 30 HP capacity complete all as specified and directed.
Renewal of ball bearing.for AHU of 15 TR to 21 TR capacity complete all as specified and directed.
Renewal of ML2 type power Contactor, 3 pole, 415 V, 50Hz, with auxulary Contact 2 NO+2NC suitable for Non-Inductive or Slightly Inductive ,Resistive Load (AC1- 45 Amps rating )/ Squirrel Cage Motor (AC3- 40 Amps rating )to match with the existing complete all as specified.
Renewal of ML3 type power Contactor, 3 pole, 415 V, 50Hz, with auxulary Contact 2 NO+2NC suitable for Non-Inductive or Slightly Inductive ,Resistive Load (AC1- 45 Amps rating )/ Squirrel Cage Motor (AC3- 40 Amps rating )to match with the existing complete all as specified.
Renewal of ML4 type power Contactor, 3 pole, 415 V, 50Hz, with auxulary Contact 2 NO+2NC suitable for Non-Inductive or Slightly Inductive ,Resistive Load (AC1- 100 Amps rating )/ Squirrel Cage Motor (AC3- 70 Amps rating ) to match with the existing complete all as specified.
Renewal of MNX45 type power Contactor, 3 pole, 415 V, 50Hz, with auxulary Contact 2 NO+2NC suitable for Non-Inductive or Slightly Inductive ,Resistive Load (AC1- 85 Amps rating )/ Squirrel Cage Motor (AC3- 45 Amps rating ) to match with the existing complete all as specified.
Renewal of MNX32 type power Contactor, 3 pole, 415 V, 50Hz, with auxulary Contact 2 NO+2NC suitable for Non-Inductive or Slightly Inductive ,Resistive Load (AC1- 32 Amps rating)/ Squirrel Cage Motor to match with the existing complete all as specified.
Renewal of Bimetal overload relay suitable for , Direct Mounting on ML Contactors, (Directly Operated) range up to 15 Amps to match with the existing complete all as specified.
Renewal of Phase voltage monitoring relay suitable for 208-420 VAC 3 Phase to match with the existing complete all as specified.
Renewal of Bimetal overload relay suitable for , Direct Mounting on ML Contactors, (Directly Operated) range 15-45/20-65 Amps to match with the existing complete all as specified.
Renewal of Bimetal overload relay suitable for, Direct Mounting on MNX Contactors, (Directly Operated) range 35/45 Amps to match with the existing complete all as specified.
Dismantling existing Monoblock pump with motor 3 HP to 10 HP, 3 Phase, 415 Volts, servicing of pump and motor by opening of pump, machining of pump shaft; renewal of gaskets, gland packing, Gun metal bushes; bearing ; greasing of bearing complete all as specified . Note:- Ball bearing renewed and motor winding shall only be measured and paid separately.
Dismantling/ taking down burnt squirrel Cage Induction Motor of any capacity , 3 Phase, 415V, 1450 RPM of any make from its base and transporting the motor to the Contractor's workshop and back, refixing the motor at site after carrying out the following repairs/ renewals complete all as specified.- (i) opening the side covers and removing the rotor and cutting/ removing the burnt coils / winding from stator. (ii) Cleaning the slots carefully. (iii) Rewinding the stator using super enamelled copper winding wire with same size, number of coils,number of turms/ coils as per data acquired from the old burnt motor, including varnishing two coats, drying and reassembling the electric motor at site. (iv) Testing the coils for there continuity and no current passing through the stator core. (v) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance vibtrations. (vi) Re-assembling the rotor and connecting the end terminals to the terminal plate of the motor, closing the ends with side covers. (vii) Testing and commissioing the electric motor connecting to the electric supply to its full load by connecting the compressor. (viii) Renewal of Bolts, nuts and washers. Note :- (i) Parts renewed i.e Ball bearing shall be measured and paid separately. However filling of grease and oiling extra shall be deemed to be included in Unit rates. (ii) The weight of copper coil provided before varnishing shall be taken for the purpose of payment.
Replacement of new Shell and Tube type condensor of 15 TR Central AC Plant as per existing including replacement of copper pipe size 7/8, 48 Nos including carrying out necessary parts and testing of leakage and pressure hold test with Nitrogen gas and vaccum with connecting the plant complete all as specified and directed.
Dismantling of side cover of Shell and tube type Condensor of Central AC plant, making arrangements fo connect the suction and Discharge line to chemical pump, descaling the condensor by circulation of discalation solution and by rodding fitted with nylon brushes of suitable size and circulation of fresh water through condensor till clear water comes from other end including carrying out necessary repairs for 15TR Capacity plant all as specified and directed by Engineer-in-Charge. Note:- (i) Parts renewed only shall be measured and paid separately. (ii) The rate quoted againt this item shall include all the T&P and solutions required .
Dismantling of suction line from compressor of Central AC plant, making arrangements for connect the cooling coil , cleaning of cooling coil with carbon tetra chloride chemical solution for flushing out coil and dust for 2x15TR Capacity plant.
Renewal of High pressure and low pressure control (HP&LP) switch for F-22 complete all as specified.
Renewal of High pressure and low pressure control (HP&LP) switch suitable for 11 TR Air Cooled package type AC unit ( Make- Blue Star) complete all as specified.
Renewal of oil pressure control switch F-22 complete all as specified.
Supply and fix in repairs thermostatic expansion valve suitable for 3x15 TR Direct expansion type AC plant including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means , cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc. complete all as specified and directed.
Supply and fix (in repairs) thermostatic expansion valve of 1x11 TR working on R-407 (c) NON CFC refrigerent gas ( Ecofriendly) suitable for 1x22 TR package type AC plant ( Make - Blue Star) including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means , cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc. complete all as specified and directed.
Supply and fix (in repairs) thermostatic expansion valve of 1x5.5 TR working on R-407 (c) NON CFC refrigerent gas ( Ecofriendly) suitable for 1x16.5 TR Air cooled package type AC plant ( Make - Blue Star) including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means , cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc. complete all as specified and directed.
Supply and fix (in repairs) thermostatic expansion valve of 1x4.5 TR working on R-407 (c) NON CFC refrigerent gas ( Ecofriendly) suitable for 1x8.75 TR Air cooled package type AC plant ( Make - Blue Star) including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means , cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc. complete all as specified and directed.
Supply and fix in repairs shaft seal suitable for 15 TR Block capacity semi sealed compressor all as specified and directed.
Renewal of V Belts of size B-81 to B-100 complete all as specified.
Renewal of V Belts of size B-40 to B-60 complete all as specified.
Supply and charging of Refrigerent gas M-22 in company sealed cylinders of any capacity complete all as specified. Note: If the recharged refrigerent gas is leaked within one month of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
Supply and charging of Refrigerent gas R-407 (c) Non CFC ( ecofriendly) in company sealed cylinders of any capacity complete all as specified. Note: If the recharged refrigerent gas is leaked within one month of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
Renewal of thermostate / temperature control switch suitable for Central/ package type AC plants complete all as specified.
Renewal of thermostate / temperature control switch suitable for 1x22 TR Air Cooled package type AC plants ( Make- Blue Star) complete all as specified.
Renewal of anti freeze switch suitable for Central/ package type AC plants complete all as specified.
Renewal of condensor safety valve of 1/2" to with stand the pressure upto 300 PSI complete all as specified.
Renewal of drier for liquid line suitable for 11 TR capacity compressor complete all as specified.
Renewal of drier for liquid line suitable for 4.5TR to 5.5 TR capacity compressor complete all as specified.
Renewal of finned strip heater ,single phase 3 KW suitable for AC plant including provision of nuts, bolts & washers etc all as specified and directed.
Material and labour for taking down/ dismantling of portion of false ceiling for internal cleaning of air ducts with cloths with care and deposting the dust particles in container , removing the grills/ diffusers, and refixing the grills, diffusers and false ceiling in its original locations including renewal of screws complete all as specified and directed ( 3x15 TR)( ASII/ASIII, 6x22TR OT PLANT,'B' BLOCK, 'C' BLOCK,X-Ray at MH)
Material and labour for servicing of cooling tower of to 2X15 TR ( ASII MH and AS III MH) capacity Central AC by draining out complete water from bottom tank, cleaning of inner surfaces with nylone brushes opening of wtaer strainer from water inlet to condensor after removal of flange and renewal of gaskets and jali after cleaning and removal of all foreign materials and descaling of complete water pipe line with descaling solution complete all as specified.
Material and labour for removing of old paint from the water cooling tower by scraping and apply new color of synthetic enamel paint by spray painting in to new color as existing to 3x15 TR water cooled AC plant(AS II AND AS III MH) as specified and directed
Material and labour for servicing of 1x22 TR air cooled package type Air Conditioner plant ( Make Blue star) by opening the plant, consisting Indoor unit-01 No and Outdoor Unit-02 Nos with air blower including cleaning Air conditioner internally and externally, cooling coil and condensing units- 2 Nos each , washing of filter of IDU with water, and drying in shade, checking and rectifying any oil leak, gas leak in all refrigerant pipes and reassembling the complete units and testing complete all as specified and directed .
Material and labour for servicing of 1x16.5 TR air cooled package type Air Conditioner plant ( Make Blue star) by opening the plant, consisting Indoor unit-01 No and Outdoor Unit-03 Nos with air blower including cleaning Air conditioner internally and externally, cooling coil and condensing units- 3 Nos each , washing of filter of IDU with water, and drying in shade, checking and rectifying any oil leak, gas leak in all refrigerant pipes and reassembling the complete units and testing complete all as specified and directed .
Material and labour for servicing of 1x8.75 TR air cooled package type Air Conditioner plant ( Make Blue star) by opening the plant, consisting Indoor unit-01 No and Outdoor Unit-02 Nos with air blower including cleaning Air conditioner internally and externally, cooling coil and condensing units- 2 Nos each , washing of filter of IDU with water, and drying in shade, checking and rectifying any oil leak, gas leak in all refrigerant pipes and reassembling the complete units and testing complete all as specified and directed .
Renewal of transformer 50 watt with CT 5 Amp unit suitable for Air cooled package type AC indoor unit of any capapcity complete all as specified
Renewal of Fan Blade suitable for Air cooled package type AC outdoor unit ( Make- Blue Star) of size 18- 22 Inch any capacity complete all as specified.
Renewal of blower fan Blade suitable for Air cooled package type AC indoor unit ( Make- Blue Star) of any capacity complete all as specified.
Supply and fix in repairs including testing harmetically sealed scroll Compressor of 11 TR Air Cooled package type AC indoor unit of 1x22 TR capacities ( Model No. DPA-2642R2 of Blue Star) , suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
Supply and fix in repairs including testing harmetically sealed scroll Compressor of 4.5 TR Air Cooled package type AC indoor unit of 1x8.75 TR capacities ( Model No. DPA-2642R2 of Blue Star) , suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
Supply and fix In repairs including testing harmetically sealed scroll Compressor of 5.5 TR Air Cooled package type AC indoor unit of 1x16.5 TR capacities ( Model No. DPA-2642R2 of Blue Star) , suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
Renewal of Base unit suitable for Air cooled packaged AC indoor unit 1x22 TR ( R-407 C non CFC refrigerent gas, including PCB card and control wiring( Model No. DPA-2642R2 of Blue Star) complete all as specified and directed.
Renewal of Base unit suitable for Air cooled packaged AC indoor unit 1x8.75 TR ( R-407 C non CFC refrigerent gas, including PCB card and control wiring ( Model No. DPA-2642R2 of Blue Star) complete all as specified and directed.
Renewal of Base unit suitable for Air cooled packaged AC indoor unit 1x16.5 TR ( R-407 C non CFC refrigerent gas, including PCB card and control wiring( Model No. DPA-2642R2 of Blue Star) complete all as specified and directed.
Renewal of LED Hand set / Key pad- 01 No complete all as specified and directed.
Material and labour for two coats of painting in copper pipe of size 3/4" and 1/2" incoming and out going from indoor compressor unit to out door unit placed over the roof of building yellow (return) and red (out going) as per colour code all as specified and directed by Engr-in-Charge.
Taking down if existing unserviceable GI ducting and Supply, assembly and erection of GI sheet with C & SS rectangular/ square duct made out of 24 gauge 'L' shaped hollow profile , duly factory boxed, including all accessories such as elbows, splinter dampers, vanes, hangers, supports Corner, cleat, Carriage bolt, gasket and appropriate sealant on longitudinal joints etc including making hole in existing wall/ ceiling and making good disturbed surfaces complete all as specified.
Taking down of old existing unserviceable thermal insulation and Supplying, installing, testing and commissioing of extrenal thermal insulation of class O conforming to BS 476 Part 7 on ducts with 9mm thick nitrile rubber having density 33 Kg/cum and thermal conductivity not exceeding 0.035 W/mK at an average temperature of 400 Centigrade including sealing the joints with aluminium tape and finally strapped with 12mm wide packing strips at 1m c/c duly laminated with Aluminium layer complete all as specified.
Taking out defective compressor of 15 TR capacity, Overhauling, testing, and commissioning of open type reciprocating compressor including dismantling and disconnecting suction and discharge refrigerant lines, other controls and accessories, loading, transporting to contractors workshop and back to plant room after necessary repairing and then reinstallation in its original position including provision and charging of refrigerent gas complete all as specified. (Note :-1. Renewal of items not covered in the succeeding items of BoQ but essentially required for completing the Job like cut washers, valve springs, castle nuts, etc shall be provided by the contractor and no extra payment shall be admissible on this account. (2).Parts renewed shall be measured and paid separately as supply only as given below.-
Supply only set of Gasket
Supply only Piston pin bush
Supply only Piston
Supply only Piston ring
Supply only Suction valve plate reed
Supply only Discharge valve plate reed
Material and labour for grinding, machining, and polishing of crank shaft suitable for normal running and matching the dia to th man bush , connecting rod and bearings etc all as specified and directed. : Parts renewed shall be measured and paid separately at supplied only rates:-
Supply only valve plate suitable for 15 TR capacity compressor
Supply only main bush/ bearing under size
Supply only connecting rod
Material and labour for reboring of cylender and installation new liner
Supply only O ring
Supply only loader and unloader
Supply only sluice valve spring and Discharge valve spring
Supply only Discharge valve assembly
Servicing of oil pump of 15 TR compressor including renewal of wornout parts, i.e. Neoprene 'O' ring,gear set and bush set
Supply only Half section bearing
Supply only Thurst washer
Supply only Heater Assembly
Supply only Filter
Material and labour for grinding, machining, and polishing of cam shaft suitable for normal running and matching the dia of bearings etc all as specified and directed.
Supplying, installing, in repair HEPA(High eficiency particulate air filter) Filters to filter the dust in the air 99.97 percent, of size 660x210x100mm of all particles 0.3 microns or larger complete as per sample all as specified.
Supplying, installing, in repair HEPA (High eficiency particulate air filter) Filters to filter the dust in theair 99.97 percent, of size 270x187x100mm of all particles 0.3 microns or larger complete as per sample all as specified.
Supplying, installing, in repair HEPA (High eficiency particulate air filter) Filters to filter the dust in the air 99.97 percent, of size314x187x100mm of all particles 0.3 microns or larger complete as per sample all as specified.
Supply & fixing in repairs 100 Amp 415V 4 pole ON load changeover switch with sheet metal enclosurs, front operated, 50Hz fixed to walls/panels with suitable size nuts, bolts and washers complete including making connection and testing complete all as specified and directed.
Supply & fixing in repairs 200 Amp 415V 4 pole ON load changeover switch with sheet metal enclosurs, front operated, 50Hz fixed to walls/panels with suitable size nuts, bolts and washers complete including making connection and testing complete all as specified and directed.
Supply and fix in repair GI Pipe heavy duty size-80mm dia complete all as specified and directed
Supply and fix in repair Gate valve for 80mm dia including nut,bolt, washer complete all as specified and directed
Supply and fix in repair Ball valve for 50mm dia incliding nut, bolt, washer complete all as specified and directed
Supply and fix in repair Condensor / Capacitor, 240V, AC, suitable for fans all as directed for capacity 4.0 mfd
All as per item No 82.00 above but capacity 7.0 mfd
Supply and fix in replacement outdoor Fan motor of capacity for compressor 5.5 to 11 TR AC plant complete all as specified and directed.
Supply and fix Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples for cooling tower complete all as specified and directed
Supply and fix new water Filter for cooling tower in AS-II&III AC plant complete all as specified and directed
Supply & fixing in repairs 160 Amp 415V 4 pole ON load changeover switch with sheet metal enclosurs, front operated, 50Hz fixed to walls/panels with suitable size nuts, bolts and washers complete including making connection and testing complete all as specified and directed.
Supply & fixing in repairs 250 Amp 415V 4 pole ON load changeover switch with sheet metal enclosurs, front operated, 50Hz fixed to walls/panels with suitable size nuts, bolts and washers complete including making connection and testing complete all as specified and directed.
Supply & fixing in repairs 315 Amp 415V 4 pole ON load changeover switch with sheet metal enclosurs, front operated, 50Hz fixed to walls/panels with suitable size nuts, bolts and washers complete including making connection and testing complete all as specified and directed.
Taking out existing old unsv cable and Material and labour including jointing testing and commissioning XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts cross section area (ISI marked) laid in trenches, ducts, pipe or fixed on pole etc of following size 240 Sqmm, 3 1/2 core cable
Taking out existing old unsv cable and Material and labour including jointing testing and commissioning XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts cross section area (ISI marked) laid in trenches, ducts, pipe or fixed on pole etc of following size 25 Sqmm, 4 core cable
Excavation in trenches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables, foundation of poles, stay etc complete all as specified.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
Material and labour sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for payment.
Material and labour bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed.
Material and labour for boring in any type of soil under road 1.5 Mtr below the top surface of road by convential method complete for passing through 80mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE:- Pipe will be measured and paid for separately. Any damage to existing cables of any type and road will made good by the tenderer without any extra payment.
Supply, installing, testing and commissioning of LT out door type factory made(CPRI Approved ), junction box of size 600mmX600mmX500mm (over all dimension )with mild steel angle iron of size 40X40X5mm vertical frame and legs with mild steel flat iron 40X6 mm in horizontal sides of the frame LT Junction box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system,The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x5 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & back opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and directed.with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock-2Nos with 3 keys with OUTGOING MCCB 4 pole, 415 volts AC grade, 200 Amps Aluminium bus bar of 600 Amps rating with drilled holes for incoming /out going cable core connection including aluminium lugs ,GI bolts ,Nuts and washers of suitable size . Porcelain / synthetic bridge insulators, heavy duty with necessary steel / GI screws ,bolts, nuts and washers -08 Nos , complete all as specified and as directed. , The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directedincluding connections of all out going/in coming existing cables of size 25/35/50/95/120/ 150 sqmm by drawing /digging out cable from loops in trenches out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed Engr-in-Charge (NOTE:-1 Panel should be 61439 Panel Builder should Submit All Certificate Before Executing the job.)
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles/walls ( with required size flat iron clamp bolts, nuts and washers ) pipes of the size 40mm bore complete all as specified and directed.
All as per item No 99.00 above but size 80mm
Material and labour for plate earthing for sub station equipments complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 3.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 2.75 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 5 of SSR Pt-I.
Supply and fixing thermoplastic/polycarbonate enclouser bus bar chamber, shock proof, vermin proof and dust proof complete with 02 Nos aluminium strip of capacity 32 amp including non metalic clapms and GI nut bolts and washers of suitable size and fixed on pole/ wall complete all as specified and directed.
Supply and fix 2 core stranded copper conductor cable 1.5 sqmm, PVC insulated and PVC sheathed, 100 Volts grade for making connection from junction box to street light fitting including PVC conduit of size 20mm dia including necessary clamps complete all as specified and directed.
Supply & fixing Sheet Metal Enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps capacity 240 volts 'B' series 10KA and making connections complete all as specified & directed including taking out old u/s any capacity.Make;- Havells/C&S /Legrand
Material and labour for replacement with new indoor unit of capacity 2.0 ton Hot & Cold with cooling coil, blower motor complete with all accessories of suitable any make of AC model.
Material and labour for replacement with New Hot & Cold outdoor unit of capacity 2.0 ton with condensor coil, blower motor 1/6 HP , single phase, including fixing serviceable compressor and connection of copper tubing suction / discharge of suitable any make of AC model including filling of gas complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
AIRCOM
M/s. S.S. Refrigeration, Bareilly
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .