Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC D 91 BLOCK D AMITY GREEN HASEMAU LUCKNOW PIN 226028 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226028 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹18.9 L+₹41,975.50 (2.27%)Rejected-Finance JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹20.9 L+₹2.4 L (13.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹21.3 L
EMD Value
₹42,600
Closing Date
16 Dec 2020, 6:00 pmClosed
GE(AF) Gorakhpur
GE(AF) Gorakhpur Pin-273008
SPECIAL REPAIR TO CIVIL ADMIN OFFICE REPLACEMENT OF NORMAL EXTERNAL PAINTING WITH CCD SCHEME OF CERTAIN BLDG IN TECH AREA PROVISION OF TILING AT COS OFFICE AT 27 SQN AND INTERLOCKING TILE FOR APPROACH PATH OF CERTAIN OMQ AT AKASH VIHAR AT AF STN GORA
2020_MES_395949_1
8742/E8
Open Tender
Civil Works
Item Rate
120 days
Gorakhpur
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) Gorakhpur
₹42,600
Yes
19 Jan 2021
18 Nov 2020
17 Dec 2020
18 Nov 2020
16 Dec 2020
4 Dec 2020
Amount
Taking down cement or cement lime plaster any description including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces and of brick work or concrete surface finishing the surface even and smooth without extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall, pilasters, cornices etc and applying two coat of exterior emulsion paint in camouflage pattern (two or more colour combination) over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old painted surface of wall and applying one coat of exterior emulsion paint in camouflage pattern (two or more colour combination) complete all as specified and directed.
M&L for complete removal of existing treatment by scrapping, washing, rubbing down & stopping etc of old painted surfaces of wall and applying two coat of exterior emulsion paint camouflage pattern (two or more colour combination) over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old painted surface of AC roof sheet and applying one coat of exterior emulsion paint in camouflage pattern (two or more colour combination) complete all as specified and directed.
M&L for complete removal of existing treatment of old painted surfaces of CGI roof sheeting and applying two coats of synthetic enamel paint in camouflage pattern (two or more colour combination) over a coat of red oxide prime complete all as specified and directed.
Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all specified and directed.
S&F light colour vitrified, 8 to 10mm thick (square/ rectangular) area of each tile exceeding 0.36sqm and n.exc. 0.42 sqm, as in floor etc, set & jointed with in neat cement slurry or with adhesive as per manufacturers instructions & pointed in white/colour cement to match over the shade of tile and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No. 09 above but on vertical surface of wall as in dado/skirting including cutting of tile in required size and 15mm thick rendering screed in CM 1:4.
Surface dressing n.exc. 15 Cm deep in soft/loose soil including removal of brick/stone pieces, herbs, shrubs & vegetation complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete or sub base of floor complete all as specified and as directed.
S&F 60-62mm thick reflective rubber moulded interlocking cloured precast PCC paver, tiles M-35 grade made up with 12.5mm graded mechanically crushed stone aggregate, factory made, of any tint, conforming to IS-15658-2006 over & including 30mm sand cushioning & filling the joints with coarse sand complete all as specified and directed.
Demolition of cement concrete un-reinforced in ground floors and paving not exc 15 cm thickness below or above ground level complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and pre-cast articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exceeding 6 metre mean radius built in CM 1:4 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding, roof kerb, coping etc mixed with liquid water proofing compound, surface finished even and fair without using extra cement complete all as specified and directed. Note:-WPC will be measured & paid separately)
M&L for 15 mm thick rendering on roof padding surface in cement mortar 1:3 mixed with water proofing compound as per manufacturer instruction, finished even and smooth without using extra cement complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately as supply only.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 mixed with water proofing compound as per manufacturer instruction, finished even and smooth without using extra cement complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately as supply only.
M&L for rendering 15mm thick in CM 1:4 on fair faces and of brick work or concrete surface finishing the surface even and smooth without extra cement complete all as specified and directed.
Supply only integral liquid water proofing compound complete all as specified and directed. Make: Dr Fixit Pidiproof LW+ or equivalent in specified make.
S&F non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm and n.exc. 0.38 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cement mortar 1:6 etc complete all as specified and directed.
All as per item No. 22 above but on vertical surface of wall as in dado/skirting including cutting of tile in required size and 15mm thick rendering screed in CM 1:4.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame n.exc 1.50 Sqm each and removing from site complete all as specified and directed.
All as per Item No. 24 above but exc 1.50 Sqm and n.exc 4 sqm each.
M&L for powder coated anodised aluminium doors (sliding/hanging type) with frame size 101.60X44.45X 2.00 mm thick and shutter aluminium anodised and top rail 47.62X44.45X1.50mm and style 47.5x44.5x1.5 mm, lock rail 83.50X44.45X1.50mm and bottom rail 150.00X44.50X2.50mm and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.4mm incl necessary aluminium fittings like aluminium butt hinges 04 Nos, aluminium handles 150mm 02 Nos, aluminium tower bolts 200mm 01 No. mortise lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stopper 01 Nos, jointing cleats, glazing cleats, rubber packing, anodised aluminium shape beading, screws etc with paneling in two parts with 12mm thick prelaminated particle board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture complete all as specified and directed.
S&F powder coated anodized aluminium sliding type glazed window shutters with 5mm thick plain sheet glass fixed open track section 100x38x1.5mm having three track (two of glass & one of stainless steel wire cloth) with members of window shutter of section 38x12x1.5mm and other standard Bombay sliding sections including necessary fiber wheel rollers suitable handles to facilitate sliding and all necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading etc all as specified and directed at site. Make of glass:- Modi/Atul/Swastik
S&F powder coated aluminium chequered grill weight exc 3.5 kg and n.exc. 5.5 kg per sqm with all fittings & fixture complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L preparing old decorated surfaces of wall by washing, rubbing down and stopping of painted surfaces and applying one coat of cement base paint complete all as specified and as directed.
M&L for preparing new plastered surface of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treatment by washing, rubbing down and stopping old surfaces of wall including scrapping and applying two coats of oil emulsion distemper over a coat of 1mm thick Birla putty as base coat complete all as specified and as directed.
M&L for preparation of old painted surface of wood and wood based material of any description area exc 10cm width or girth and applying one coat of synthetic enamel paint as directed.
Taking down carefully copper/aluminium point wiring light/fan/bell/socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ ceilings complete all as specified and directed .
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia medium grade with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc with provision of new GI terminal boxes of not less than 1.60mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete all as specified and directed for the following:- (a) one light/fan point controlled by one switch
(b) All as per item No 35 above but one socket outlet 3/5 pin 5/6 amps independent controlled by one switch
(c) All as per item No 35 above but one socket outlet 3/5 pin 5/6 amps controlled by one switch on same board.
Material and labour for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note for item Nos 35 to (e) to 38:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F in replacement switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
All as per item No. 39 above but of 15/16 Amps.
S&F in replacement socket outlet, 5 pin, 5/6 amps flush type complete all as specified and directed.
S&F in replacement socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed.
S&F in replacement of ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F ceiling fan complete with all electronic fan regulator and accessories of capacity 230V, 1200 mm sweep, BEE 5 star rating complete all as specified and directed. Make: Havells, Model No. ES 50 Premium 5 or equivalent in Bajaj/Crompton.
S&F exhaust fan single phase 230/240 volt AC 300mm sweep, 1400 RPM with painted louvers, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc required for fixing fan and making good to match the existing surface and making connection with twisted copper flexible wire 23/0.0076mm complete all as specified and directed. Make: Havells/Bajaj/CG.
S&F in replacement wall mounted batten integrated LED plastic channel with tube of capacity 20 Watt (4ft), integral sleek extruded polycarbonate LED channel with white acrylic cover and integrated electronic driver complete fixed/connect properly complete all as specified and as directed. Make:-Bajaj/Havells/Philips/C&S
All as per Item No. 46 above but for capacity 9-10 watt (2ft).
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1 :3 for concealed water tubing/wiring, cutting n.exc. 10cm girth complete all as specified and directed.
M&L for replacement sub main wiring with 2 Nos single core PVC insulated -unsheathed 4.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4 Sqmm conductor cable, 1 No. 2.5 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for replacement sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 Sqmm conductor cable, 1 No. 2.5 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F in replacement factory made epoxy powder coated distribution board double door TPN 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 100/ MCB 63 Amps as incomer and TPN/SP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified & directed.
S&F in replacement factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F in replacement MCB SP 6 to 32 Amp 240 volts 10 KA breaking capacity 'C' curve complete all as specified and directed.
S&F in replacement MCB SPN 40 Amp 240 volts 10 KA breaking capacity 'C' curve complete all as specified and directed.
S&F in replacement MCB TPN 63 Amp 415 volts 10KA breaking capacity 'C' curve complete all as specified and directed .
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
M&L for earthing complete with galvanized steel earth plate 60cmx60cmx6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover and frame all as shown in electric plate of SSR part-I (2009), including testing on completion all as directed.
DEEP ENTERPRISES
m/s eastern technocrafts
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .