| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹22.0 L+₹3.2 L (17.3%)Rejected-Finance NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹27.4 L+₹8.7 L (46.4%)Rejected-Finance | L3 | Rejected-Finance Being not a lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
5 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
GER-29/2023-24 Rewiring / repair to internal electric wiring and connected works and repair replacement of sub mains, main switches, service wires and cables at Zone -A of AGE E/M under GE 862 EWS
2023_MES_612199_1
GER-29/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS
Class D b(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹60,000
Yes
21 Sept 2023
4 Aug 2023
7 Sept 2023
4 Aug 2023
5 Sept 2023
18 Aug 2023
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including casing & caping of 25mm width (Medium grade double locking system) complete with all accessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the disturbed surfaces, compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per srl item No. 2 above but for socket outlet 5 Amps on independent board, complete all as specified and directed.
Description all as per srl item No. 2 above but for socket out 5 Amps on same board, complete all as specified and directed.
Description all as per srl item No. 2 above but for one bell point controlled by one bell push, complete all as specified and directed.
Description all as per srl item No. 2 above but for one light point controlled by 2 way switch, complete all as specified and directed.
Description all as per Serial item No 2 above but for one 3 pin 16 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper conductor cable with 2.5 sqmm single core multistraind FRLS copper cable as earthing lead, complete all as specified and directed.
S&F for switch piano flush type single pole one way 6 Amps 240 volts, complete all as specified and directed.
S&F for switch piano flush type single pole two way 6 Amps 240 volts, complete all as specified and directed.
S&F for bell push flush type single pole one way 6 amps 240 volts, complete all as specified and directed.
S&F for switch socket combination 2 in 1, 5 pin, 6 Amp flush type, complete all as specified and directed.
S&F for socket 2 in 1, 5 pin, 16 Amp flush type 230 volts, complete all as specified and directed.
S&F for fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically, complete all as specified and directed.
S&F for call bell AC, 230 volts, single pole, ding-dong sound type, complete all as specified and directed.
S&F for ceiling rose 3 phase/PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals, complete all as specified and directed.
S&F in repair for lamp holder insulated body PVC/ Polycabonate type with back plate suitable for angular fittings including LED lamp 9 Watt, complete all as specified and directed.
S&F in repair for LED tube battens 20 watt, 240 volts including , complete all as specified and directed
S&F in repair for retrofit LED bulb 9 watts, 240 volts, 50Hz suitable for housing in pendent/batten/angular holder, complete all as required at site or directed.
M&L in repair for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height, complete all as specified and directed.
M&L in repair for 18 Watt LED recess/surface mounting 3000k/6000k light fitting LED backlit round or square (as reqd at site) down lighter with high efficient LEDs & glare free opal diffuser IP20, internally prewired, 230 V, complete with all accessories such as electronic driver, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item with all connected accessories, complete all as specified and directed. (Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost).
S&F in repair for LED tube light fittings 1x10 watts, complete with 2 feet decorative ultra slim near LED lighting fixture with co extruded polycarbonate body, environmental friendly energy effcient ready to use complete prewire and connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
S&F in repair for LED Tube light fitting, 1x 5 watts, complete with 1 feet Decorative ultra slim linear LED lighting fixture with co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as required at site or directed.
S&F in repair for decorative wall light made up of high grade engineering plastic material suitable for 9 watt LED lamp B-22 base co extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete prewired and connecting electrically, complete all as specified and directed.
S&F in repairs high efficacy 2 x 2 feet recess / surface mounting LED flat panel light fittings 36W LED 3000K - 6000K edge - lit luminaire as required on site and including LED lamp suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. Note: Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost.
S&F in repair for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 13.5 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
S&F in repair for LED bldg street light fitting 35 watt 230 volt AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,complete all as specified and directed
S&F in repair for driver suitable for LED light fitting high efficiency 2"x2" recess LED flat panel light 24W to 40W with due care and refixing the fitting after servicing including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm, complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 10 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 10 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. (Note : - 02 run of 10 sqmm single core copper conductor cable and 01 run of 10 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. (Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
S&F in repair for MCB distribution board TPN 4 way, double door 415 volts duly painted with epoxy based powder coated painting suitable for mounting MCB, TP/FP as incomer of rating upto 63 Amps, FP and MCB SP/TP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate with IP 42 protection including removing old unserviceable item, complete all as specified and directed. (Note:- MCBs will be measured and paid separately.)
S&F in repair for factory made sheet metal enclosure, double door, 415 volt, AC, TPN vertical distribution board 4 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 160 Amps, four pole, rating upto 36 KA and MCB SP/TP as outgoing and complete with including 200 Amps rated copper busbar, neutral bar, earth bar, conneting cable links with and including top bottom removeable gland plate complete with IP 43 protection, complete all as specified and directed. (Note:- MCBs will be measured and paid separately.)
M&L in repair for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volt 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good disturb wall surfaces to match with existing specification, complete all as specified and directed. (Note:- MCBs will be measured and paid separately.)
M&L in rapair for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volt 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good disturb wall surfaces to match wiht existing specification, complete all as specified and directed. (Note:- MCBs will be measured and paid separately.)
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and directed.
M&L for MCB four pole 415 volts any rating from 63 amps, with rupturing capacity 10 KA, including providing thimble for out going, cables, complete all as specified and directed.
M&L in repair for MCCB FP 415 volts any rating from 63 Amp with rupturing capacity 16 KA, including providing thimble for out going cables, complete all as specified and directed.
S&F in repair for sheet metal enclosure with socket plug top and MCBs single pole with one MCB 240 volts 20 amps, complete all as specified and directed.
Supply, Laying, connecting and testing of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories, complete all as specified and directed.
Supply, Laying, connecting and testing of service cable of size 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories, complete all as specified and directed.
Supply,laying, connecting, testing and commissioning, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE)
Supply,laying, connecting, testing and commissioning, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE)
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil, for foundation, etc, or for shafts, wells, drain pipes n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness, complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable, complete all as specified and as directed (Note: Punned thickness of sand shall be measured and paid).
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing, complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
S&F for cable tray 150mm wide x 100mm deep with coupler plates, hot dip galvanised with standard slot pattern thick duly pre-treated with hot dip galvanised in seven tank process, perforated type including provision of fixing arrangement nuts & bolts etc for proper securing to walls/beams or suspended from ceiling or along with road with mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B1 (using 20mm graded stone aggregate) in foundation after taking down old unserviceable cable tray with fittings etc, complete all as specified and directed.
M&L in repair for 40mm bore galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
M/S SURINDER KUMAR MAHAJAN
M/S PARSHOTAM KUMAR GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .