Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.4 LAccepted-AOC OLD AIRPORT ROAD W ANBAL SRINAGAR J K 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹19.8 L+₹1.2 L (6.19%)Rejected-Finance | L-2 | Rejected-Finance Other than L-1 | |
| 3 | L-3₹20.4 L+₹1.8 L (9.39%)Rejected-Finance | L-3 | Rejected-Finance Other than L-1 | |
| 4 | L-4₹22.5 L+₹3.9 L (20.6%)Rejected-Finance | L-4 | Rejected-Finance Other than L-1 | |
| 5 | L-5₹22.7 L+₹4.1 L (21.9%)Rejected-Finance | L-5 | Rejected-Finance Other than L-1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
23 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt. Col Preetham P GE
GE 970 EWS C/o 56 APO PIN-913970
REPAIR AND MAINT OF INTERNAL WIRING, INCL ELECTRIC FITTINGS, FIXTURES AND SECURITY LIGHTS JUNCTION BOX ETC AT HAFT CHINAR MANASBAL SONAMARG UNDER GE 970 EWS
2023_MES_626584_1
GE 970 EWS-41/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
HAFT CHINAR MANASBAL SONAMARG
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹72,000
Yes
18 Jan 2024
3 Nov 2023
29 Nov 2023
3 Nov 2023
23 Nov 2023
17 Nov 2023
Amount
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, fan regulator etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) ISI marked medium grade white colour or Non metallic rigid PVC Conduit not less than 20 mm dia as per ground requirement with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switches, fan regulators etc for one light/fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp switch socket out let on the independent board complete all as specified and as directed
All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp socket out let on the same board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping (double interlock type) of as required width (not less than 20 mm in width) ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC Box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 4 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
Ditto all as per item No 7 here in before, but two run of single core 6 sqmm and one run of 6 sqmm cables as earth continuity conductor all as directed.
Switch Piano flush button single pole one way 5 A , 240 V complete all as specified and as directed
Switch Socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and as directed
Switch Socket Combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed
Socket outlet 3 pin, 5 Amp flush type, 240 V, complete all as specified and as directed
Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
Stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
S & F in repairs MCB DB SPN 8 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
Ditto all as per item No 15 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
S & F MCB SPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SPN 40 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with & including 9 watt LED bulb complete all as specified and directed.
S & F in repairs 1 x 20 watt LED 6000K (4Ft) Decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate environment friendly, energy efficient, extruded plastic and deorative end cap body Heat srink provided for efficient disspation and integrated electronic driver copmplete with lamp complete all as specified and directed.
S & F in repairs 1x 09 watt LED 6000K (2Ft). Decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate environment friendly,energy efficient, extruded aluminium body Heat srink. Provided for efficient disspation and integrated electronic driver copmplete with lamp complete all as specified and directed.
Supply and fixing in repair square shape 36 watt 220 volts AC recessed mounting type low depth aesthetically designed LED 2x2 feet flat with driver (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts etc complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 Mtr in wide, exceeding 1.5 m depth and not exc. 3.0 m in depth for taking out / laying of under ground cable in trenches or cable ducts complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified and directed.
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I complete all as specified and directed. Note : punned thickness shall be measured for payment purpose
Supply and lay brick of conventional size 230x115x75mm locallly available as protection of cable in trenches complete all as specifed and as directed.
M&L for 50mm dia GI pipe light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
M&L for 80mm dia GI pipe light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
M&L for 100mm dia GI pipe light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
S&F in repair of 1.5 sqmm 3 core pvc insulated flexible copper conductor wire from street light terminal box to fittings of required length drawn through and including PVC conduit of suitable size or as indicated and directed.
Material & lalbour in replacement of cable junction box/ distribution board IP 65 with metric knockouts for cable entry of size 10 to 25 Sqmm x 2 core including fastening clamp with LT pole, box size : 333 x 233 x 120 mm (or nearest higher size) hinged cover with locking arrangements including with terminals TPN strip, with 01 No. MCB SP 6A complete all as specified and directed.
Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 16 to 70 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified and directed. Note ;- Lugs and Glands will be measured and paid separately.
Taking up/down old unserviceable LT UG cable from any description (trenches, walls, ceilings.,etc) from various locations, including any length, complete all as specified and directed. NOTE:- 1. Excavation , concrete cable protection bicks, pipe, PCC work for crossing/hard standing and sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), gable gland, new nut bolt and washers of required size shall be deemed to be included in the unit rate quoted by the tenderer.
Supply and laying under ground LT cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 4 core, with aluminium conductor with suitable size aluminium cable lugs and jointed in any description complete all as specified and directed. NOTE:- 1. Excavation , concrete cable protection bicks, pipe, PCC work for crossing/hard standing and sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), gable gland, new nut bolt and washers of required size shall be deemed to be included in the unit rate quoted by the tenderer.
All as per item Sl No 37 above but of size 16 sqmm 2 core
All as per item Sl No 37 above but of size 25 sqmm 4 core
All as per item Sl No 37 above but of size 35 sqmm 3.5 core
M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 16sqmm x 4 core cables including testing and commissioining complete all as specified Make : Densons / 3M / Raychem
All as per item Sl No 41 above but of size 25 to 50 sqmm x 3.5 / 4 core, as per the size of existing UG cable. Make : Densons / 3M / Raychem
Material & labour in repairs ACSR conductor any size from poles including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and dirceted.
Supply & fixing in repair 250 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specifeid and directed.
Supply & fixing in repair 250 A 3 pole MCCB, 36 KA , 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.
Supply & fixing in repair 200 A 3 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal setting including necessary cable lugs & wire etc complete all as specified and directed
Supply & fixing in repair 100 A 3 pole MCCB, 16KA , 415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete all complete as specified and directed.
Supply & fixing in repair 63 A TP MCCB, 16 KA, 415V, 50 Hz, AC supply including necessary cable lugs & wire etc complete as specified and directed.
Supply & fixing in repair digital type Ammeter 96X96 mm square Flush mounted case of class 1.0 complete as specified and directed. MAKE : AE / IMP / MECO / MEI / HPL
Supply & fixing in repair digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 complete as specified and directed. MAKE : AE / IMP / MECO / MEI / HPL
Supply & fixing in repair CT 400 - / 5A, 200/5A or 100/5A for ammeter complete as specified and directed. MAKE : AE / IMP / MECO / MEI / HPL
M&L in repair for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion.
Dismantling old unsv conventional earth pit including electrode plate/pipe from position and material and labour for maintenace free modern marconite® conductive concrete based technology earthing system in same or different place where directed with copper earth electrode of suitable size including back fill compound and other accessories as required and recommended by OEM and connecting with copper strip of size 25x3 mm in position (connecting upto 7.5 mtr length max) complete all as specified and as directed and having following specifications :- a) Fixed Carbon 98.5 % b) Ash, Volatile and Water 1.5 % c) Sulphur Content 1.5 % Maximum d) Size Grading (Approx) - 10% below 0.10 mm, 5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm (e) Thermal Stability Between (-) 10% and (+) 60% ambient temperature (f) Ultra Low Resistivity (g) Versatile - shall be suitable for all type of soil and climate (h) Consistent Performance (i) Chemically Inert (j) Non-corrosive (k) Maintenance free and life span.
M & L for painting the steel surfaces of any description, over 10cm width or girth with synthetic enamel paint after preparing the old surface, properly removing the dust, wornout material, applying one coat of primer all complete as specified and described.
Taking out old unserviceable steel tubular/RCC poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed by Engr-in-Charge.
Supply and fixing in repair off load change over switch in sheet metal enclosure of capacity 4P 63 Amps, complete all as specified and directed.
Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 100 Amps, complete all as specified and directed.
Supply and fixing in repair on load change over switch in sheet metal enclosure of capacity 4P 200 Amps, complete all as specified and directed.
S & F in repair of Integral LED street light luminaires 35 Watt complete comprising of epoxy powder coated housing, enclosed with glass cover in front having 3500 lumen output mounted on MCPCB in gress protection IP-66 complete all as specified and as directed. Make : Havells or equiavalent in Phiips/ Crompoton.
S & F in repair of Integral LED street light luminaires 45 Watt complete comprising of epoxy powder coated housing, enclosed with glass cover in front having 4500 lumen output mounted on MCPCB in gress protection IP-66 complete all as specified and as directed.
S & F in repair of LED driver suitable for upto 4500 lumen lumanaries complete all as speified and directed.
S & F inrepair of 150W LED flood light of die cast aluminium body, IP-66 including all accessories as required complete all as specified and as directed.
S & F in repair of 240/250W LED flood light of die cast aluminium body, IP-66 including all accessories as required complete all as specified and as directed.
Taking down of existing unserviceable street light fitting bracket and supply and fix new brackets made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers complete all as specified and directed.
Taking down of existing unserviceable clamps and supply and fixing new clamps made out of 40x6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair MCB SP 5/6 amp, 'C' curve, 10 KA, 240V complete inside existing postion of street light terminal boxes including taking down old unserviceable all as specified and as directed.
S&F in repair rigid non-metallic PVC conduit of 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc including taking down old unserviceable all as specified and as directed.
M/S GHULAM MOHD AND CO
M/s Nasir Rasool Dar
Kesar Impex
M/S Noor Mohammad Shalla
M/S MIR SAJAD ENTERPRISES
FIRDOUS AHMAD BABA
M/S GASSI CONSTRUCTION AND CO
M/S B A Traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .