Garrison Engineer Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
ADDN/ALTN TO LT ELECTRICAL NETWORK, FIRE HYDRANT SYSTEM AND REPAIRS TO TOILET, INTERNAL WIRING and SUB MAIN WIRING AND CONNECTED ITEMS AT KV SCHOOL CH (EC) UNDER GE (A) KOLKATA
2026_MES_798799_1
GE/ALP (8759) KOLKATA OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Garrison Engineer Alipore
Class D category b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer Alipore
₹59,300
Yes
Garrison Engineer Alipore
16 Nov 2026
16 Nov 2026
14 Dec 2026
16 Nov 2026
7 Dec 2026
30 Nov 2026
16 Nov 2026 - 23 Nov 2026
24 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying and testing, LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed. | 145 | RM | - | - |
| 2 | All as per BoQ Serial Item No.1.00 above but with stranded aluminium conductor of size 25 sq mm 4 core. | 300 | RM | - | - |
| 3 | All as per BoQ Serial Item No.1.00 above but with stranded aluminium conductor of size 16 sq mm 4 core. | 75 | RM | - | - |
| 4 | Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sq mm, 2 core, 1100 Volts grade complete all as specified and directed. | 150 | RM | - | - |
| 5 | All as per BoQ Serial Item No.4.00 above but with with stranded copper conductor of size 2.5 sq mm ,2 core, 1100 Volts grade. | 150 | RM | - | - |
| 6 | S&F in repairs LED street light fitting, 70 watt, 230 V, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. | 10 | Each | - | - |
| 7 | S&F in repairs steel tubular swaged poles, type 410 SP 31 (overall length 9.00 m) with cast iron base plate, finial taper plug, bolts, nuts screws and washers with & including painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paint over & including a coat of red oxide primer and writing pole No with white paint on black back ground complete all as specified and as directed. | 10 | Each Job | - | - |
| 8 | S&F in repair street light junction box of size 300mm x 200mm x 105mm with MCB, SP, 6A, - 02 Nos, 10KA capacity, and 04 nos terminal for looping of cable on procelin insulator suitable capacity for 3 phase and neutral complete with necessary MS clamp made of 25x3 mm MS flat, bolts, nuts, wahsers etc for fixing to steel tubular / rail pole including dismantling of existing old unserviceable junction box with all accessoreis complete all as specified and as directed. | 10 | Each | - | - |
| 9 | Supplying, installing, commissoning & testing of 16M high mast lighting system with its accessories, mast shaft shall be in two sections with steel material confirming to BS EN 10025/IS 2062 hot dip galvanised confirming to IS 4759/IS 2629 and suitable for wind velocity as per IS 875. It shall also include accessories for 'high mast' including head frame, steel wire rope 6 mm dia (7/19 construction), trailing cable, double drum winch, gear box, galvaniseed lantern carriage arrangement suitable for 08 luminaires symmetrically. The following items is deemed to be included in quoted rates complete all as specified and directed:-
(i) Supply of LED flood light luminaire type capacity 120 w with potted driver and 10 kv surge protection device.
(ii) Supply of LED double dome aviation obstruction lights.
(iii) Supply of control panel housing 32 A TPN MCB incomer, double dial timer contactor circuit for the automatic control of luminaries, outgoing terminals and control circuit for the power tool motor.
(iv) Complete foundation work as per manufacturer design/ recommendation. | 1 | Each Job | - | - |
| 10 | M&L for earthing with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. NOTE: Main earthing lead & protection pipe 40 mm dia light grade from earth electrode to test point upto 7.5 mm is deemed to be included in quoted rate. | 1 | Each Set | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_896137.xls
BOQ • 5.81 MB
doc.pdf
Tender Documents • 1.22 MB
SCH.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .