Loading…
Loading…
Tender Value
₹43.0 L
EMD Value
₹86,000
Closing Date
7 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
12 conditions · 1 needing a document upload
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
7 conditions · 2 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part- I of attached GCC-2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical work in C/w Balance works of Soft Upgradation of Suratgarh station under jurisdiction of ADEN- Suratgarh.
14-EL-BKN-E-Tender-26-27~NWR
14-EL-BKN-E-Tender-26-27
Open
Works - General
6 Months
Bikaner, Rajasthan
₹0
₹86,000
13 Aug 2026
13 Aug 2026
24 Aug 2026
133 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 43,01,740 | ||
| — | 750.00 | — | — | ||
| Supplying and drawing FR PVC insulated & unsheathed flexible 3 Core X 1.5sqmm PVC Unarmoured copper cable ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. | — | — | — | 46,500 | |
| — | 40.00 | — | — | ||
| Supply and Fixing of Battery-Enabled Emergency LED tube light fitting, 18-20 W, batten type, 4-feet long, complete with in-built Li-ion battery, providing minimum 04 hours backup at reduces load, including all accessories as per specifications. Make- Orient, Crompton, Phillips, Surya, Havells, Jaguar Halonix, HPL, Bajaj, Wipro and Eveready with warranty of 02 years. | — | — | — | 40,600 | |
| — | 28.00 | — | — | ||
| Supply and Fixing of 36/40W Inverter Street light, Battery-Enabled with Clear Toughened glass having Housing Aluminium PDC, Inverter Load Operation 20-25% of rated system wattage for 1.5-2 Hours operation at STC battery fully charged , Battery Used 3.7V Li-ion Battery-BIS compliance cells, RTC based ON/OFF Timing- Factory set pre-programmable Auto ON-OFF, LED-LM 80 certified. LED Lumen Maintenance 50,000 hours @ L70 as per LM 80 report of LED. IS Standard IS 10322 (Part-5/Sec-3) Operating Voltage Range 140V 270 , System Lumen Efficacy 110 lm/W ,Driver Efficiency 85% ,System Protections: Open & Short circuit protection, reverse polarity protection, high voltage cut off at 310V±20V and 5KV Internal Surge, LED Indications-Red Stable-230V AC available, Green Blinking-Battery Charging, Green Stable-Battery full charge with warranty - 2 Years as per specification. Make- Orient, Crompton, Phillips, Surya, Havells, Jaguar Halonix, HPL, Bajaj, Wipro or similar of reputed make. | — | — | — | 2,31,392 | |
| — | 20.00 | — | — | ||
| Supply and erection of 5 m high with single/ double arm model no. BOP-5030 of Bajaj or similar, hot dip galvanized steel octagonal pole with galvanized base plate of 200x200x12 mm, junction box with 6 Amp. MCB and stud terminals (for mounting inside the base compartment of pole), foundation bolt size 4x16mm dia. 600 mm in length including excavation and making foundation as per spec. and drawing. It shall be galvanized internally and externally by single dipping methods. The pole and foundation shall be made as per specification and drawing attached. (Inspection Clause: By Railway Representative). | — | — | — | 1,94,080 | |
| — | 40.00 | — | — | ||
| Supply of material, foundation bolts, etc. and casting of foundation suitable for 5 Mtrs pole with M-20 as per specification /drawing and satisfaction to site engineer. (Supply of octagonal Poles are not included in this NS) | — | — | — | 1,18,440 | |
| — | 80.00 | — | — | ||
| Fixing of LED Street light with all its accessories as per site requirement and instructions of site engineer. | — | — | — | 10,080 | |
| — | 40.00 | — | — | ||
| Removal of existing Octagonal pole & making the ground level good by suitable cement concrete and transportation of rail/swage/octagonal pole and all accessories with fitting etc. Complete from the site to another location as per instructions by concerned SSE/Elect. | — | — | — | 6,880 | |
| — | 40.00 | — | — | ||
| Erection of octagonal Pole with fixing and installation of street light fitting including labour charges and other expenditure as instructed by site engineer. | — | — | — | 24,920 | |
| — | 20.00 | — | — | ||
| Supply of compact body LED street light 70W / 72W outdoor type complete with all accessories and integral electronic driver. Reputed make like Orient, Crompton, Phillips, Surya, Havells, Jaguar Halonix, Bajaj, Wipro, and Eveready Minimum 5 years warranty. | — | — | — | 84,320 | |
| — | 300.00 | — | — | ||
| SITC of LED down light fitting complete with luminaire (Note: The unit is taken per unit which means WATT) | — | — | — | 21,600 | |
| — | 25.00 | — | — | ||
| Supplying, fixing and commissioning of Air circulator fan 24' with all accessories as per requirements. | — | — | — | 2,34,425 | |
| — | 1.00 | — | — | ||
| Supply and fixing of TPN MCCB double door DB 12+2 way with 4P 100A (25 kA) MCCB-1 no., 2P 63A, 100 mA RCCB-3 no. and 2P 25A 'C' series 10 kA MCB-18 nos. MCCB, MCB, RCCB and DB should be as per tech spec. and of same make. | — | — | — | 29,976 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of SPN DB 12 Way with suitable IP protection having 1 No. RCBO 40 Amp Cap., sensitivity 30 mA in the incoming and in outgoing 06 Nos. 10-32 Amp. SP MCB, 10 kA, 'C' curve, 10KA as required with bus bar, neutral bar and necessary wire sets. As per specification. MCB, RCBO and DB should be as per tech spec. and of same make. | — | — | — | 14,508 | |
| — | 2.00 | — | — | ||
| Supply and fixing of Double Door MCB TPN DB SP (8+12 module), neutral and earth link, 4 way with one no four pole MCB 63 amp, one no Four Pole RCCB 63 amp 30 mA and twelve no SP MCB 32/25/16/10/6 amp. | — | — | — | 20,560 | |
| — | 150.00 | — | — | ||
| Supply and fixing of Rigid PVC conduit size 25 mm and its accessories, as per IS: 9537 part III High mechanical stress (HMS) type including fixing accessories. Anchor or similar of reputed make. | — | — | — | 14,400 | |
| — | 150.00 | — | — | ||
| Making and filling of chase for 25 mm dia PVC/MS conduit. Surface of chase shall be made good in all respect and satisfaction of engineer incharge. | — | — | — | 1,350 | |
| — | 100.00 | — | — | ||
| Supply and installation of PVC trunking of size 35mm X 30mm. This PVC Trucking shall be made up of High Quality Rigid Polyvinyl Chloride Material which is Fire Retardant & CE Certified, which adheres to international standards in all process of manufacturing, thus enduring a product which meets the high level of Quality and Safety. The installation work shall be executed to the satisfaction of Site Engineer. | — | — | — | 7,100 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of single phase, 230 volt 50 Hz operating ventilation fan of 300 mm. sweep with louver shutters. Fan should be of reputed make. | — | — | — | 20,250 | |
| — | 2500.00 | — | — | ||
| Supply of 4 x 16 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098(Part-1) and as per tech spec. (Inspection Clause: By Railway Representative). | — | — | — | 3,37,500 | |
| — | 500.00 | — | — | ||
| Supply of 4 x 70 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098(Part-1) and as per tech spec. (Inspection Clause: By Railway Representative). | — | — | — | 1,52,000 | |
| — | 800.00 | — | — | ||
| Supply of 4 x 120 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. (Inspection Clause: By Railway Representative). | — | — | — | 4,55,200 | |
| — | 3800.00 | — | — | ||
| — | — | — | 95,000 | ||
| — | : - Laying, be supplied | testing, commissioning tray etc. with complete by Rly. from main depot. | LT of | ||
| — | 2150.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. (trench work may be on kuchha/pucca land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 90,300 | |
| — | 20.00 | — | — | ||
| Cutting of cement concrete floors(PCC / RCC), any type / depth as required for laying of UG cables in trenches and disposing off the excavated material as directed including refilling the trenches in layers and consolidating complete all as specified and directed. Note:-Providing barricading and danger lighting around the excavated area as safety precaution is a mandatory requirement and cost of this provision, wherever required, is deemed to be included in the quoted rate of this item. | — | — | — | 25,600 | |
| — | 20.00 | — | — | ||
| Supply & providing of cable marker. The cable marker shall be made of MS Sheet 1.5mm thick size 150X100mm welded with 12mm dia MS rod 85 cm long. The lower end of rod should be turned in hooks shape and attached with the cable at the time of laying. (As per specification) | — | — | — | 3,860 | |
| — | 1800.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, PN 6, PE 80 under the road. (Inspection Clause: By Railway Representative). | — | — | — | 1,27,800 | |
| — | 1800.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 16,200 | |
| — | 450.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, PN 6, PE 80 as per requirement. (Inspection Clause: By Railway Representative). | — | — | — | 46,350 | |
| — | 450.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, under the ground/road. The work involves laying of HDPE pipe along with transportation | — | — | — | 6,300 | |
| — | 300.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN 6, PE 80 as per requirement. (Inspection Clause: By Railway Representative). | — | — | — | 1,21,800 | |
| — | 300.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 110 mm dia, under the ground/road. The work involves laying of HDPE pipe along with transportation. | — | — | — | 4,500 | |
| — | 4.00 | — | — | ||
| Supply and fixing of junction box size 390x305x170mm comprising of SMP/FRP material with rubber gasket, locking arrangement, zinc passivated earth bolt, etc. similar to Sintex model no. GSJB 3525 or similar with 4 no. aluminium busbar cap 200 Amp. suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole/ wall as per requirement. All the material should be of good quality and as per tech. spec | — | — | — | 9,024 | |
| — | 40.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 38 mm dia. Pipe should be of reputed make and as per tech. spec. | — | — | — | 5,640 | |
| — | 30.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make and as per tech. spec. | — | — | — | 6,750 | |
| — | 30.00 | — | — | ||
| SITC of 4 meter lengh B Class 50 mm dia GI pipe earth station with digging pit & refilling with charcoal & salt. (As per specification) | — | — | — | 46,320 | |
| — | 30.00 | — | — | ||
| Construction & supply of earth pit CC furnished chamber 300 x 300 x 250 mm, 50 mm thick with CI/RCC earth pit cover 300 x 300 x 25 mm with lifting hooked in center as per requirement | — | — | — | 21,000 | |
| — | 280.00 | — | — | ||
| Supply, laying and fixing of 25 x 5mm GI earth strip at 0.5 meter below ground level or on walls/poles / along pipes etc., including connection / termination with GI nut, bolt, washer etc. as required (jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm). Note:- Suitable GI saddles with screws shall be provided to secure earth strips run on walls /floors etc. | — | — | — | 49,560 | |
| — | 1.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of LT panel, medium voltage.(a) Incoming 1 x 400 amps.4 pole MCCB with adj .overload and adj. short circuit trip unit and breaking cap 50 kA (Ics = 100% Icu).(b) Outgoing 2 x 200 and 2 x 160 amps. 4 pole MCCB with adjustable overload and adj. short circuit trip unit and 2 x 125 amps. 4 pole MCCB with adjustable overload and fixed short circuit trip unit breaking cap. 36kA (Ics = 100% Icu). As per technical specification. (Inspection Clause: By Railway Representative). | — | — | — | 1,67,766 | |
| — | 16.00 | — | — | ||
| Supply of material, fabrication, installation and commissioning of Rolling in Examination lighting MS box of suitable dimension comprising of sheet steel 1.6mm thick, 60 micron powder coating - grey shade, gland plates, neoprene EDPM/rubber gasket, padlock arrangement, zinc passivated earth bolt, canopy etc. All the material should be of good quality. | — | — | — | 85,696 | |
| — | 32.00 | — | — | ||
| Supply and fixing of LED flood lights 30 W, outdoor type suitable for Rolling in Examination Hut as per specification Make Orient, Crompton, Phillips, Surya, Havells, Jaguar Halonix, HPL, Bajaj, Wipro or similar of reputed make. | — | — | — | 67,520 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A, double pole, 30mA with Earth leakage, overload and short circuit protection as per spec. | — | — | — | 25,610 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A, Four pole, 30mA with Earth leakage, overload and short circuit protection as per spec. | — | — | — | 19,430 | |
| — | 15.00 | — | — | ||
| Supply and fixing of 4/8 module metal encloser for fixing of RCBO as per IEC 61439- 3, Suitable for flush mounting and surface mounting with door for IP 54 , similar to Legrand model no. 5077 91/93 of reputed make. | — | — | — | 9,465 | |
| — | 2.00 | — | — | ||
| Supply of unit maintenance free earth material as per RDSO Specs. No RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest. | — | — | — | 20,072 | |
| — | 2.00 | — | — | ||
| Installation of unit maintenance RDSO/PE/SPEC/PS/0/0109 ( REV.0 ) 2008 or Latest. | — | — | — | 8,456 | |
| — | — | — | RDSO | ||
| — | 50.00 | — | — | ||
| Supply of material and laying of perforated GI cable tray of size 100mm X 50 mm with cover and all fixing arrangements as per specification and as per site requirement. (Inspection Clause: By Railway Representative). | — | — | — | 21,850 | |
| — | 50.00 | — | — | ||
| Supply, installation, testing and commissioning of 50 mm. height and 200 mm. width GI perforated cable tray and all required mounting accessories as per technical specification. (Inspection Clause: By Railway Representative). | — | — | — | 26,850 | |
| — | 100.00 | — | — | ||
| Supply of materials & laying of perforated GI cable Tray cable Tray 300 mm x 50mm with cover and fixing arrangement. (Inspection Clause: By Railway Representative). | — | — | — | 1,23,300 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated feeder pillar distribution box made of MS sheet 1.6 mm thick size 600mmX300mmX600mm with suitable MS stand copper bus bar of 200 Amp. capacity and 2X63 Amp MCB four pole as per technical specification. | — | — | — | 6,869 | |
| — | 300.00 | — | — | ||
| Drilling of horizontal bore below Track/Road by pushing method (trenchless technology) for laying of RCC/HDPE/DWC pipe of various sizes up to 200 mm dia. in presence of Railway representative taking all necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. Below from ground level at railway track portion. | — | — | — | 3,96,600 | |
| — | 2.00 | — | — | ||
| Provision of suitable foundation of appropriate height with concrete and cement for water cooler as per site requirement and instructions of railway site supervisor. | — | — | — | 4,590 | |
| — | 10.00 | — | — | ||
| Supply and fixing of MCB DP 32 amp, C series with encloser. Breaking capacity not less than 10 KA. | — | — | — | 14,510 | |
| — | 50.00 | — | — | ||
| SITC of MCB (SP-) 6-32 A "Series of as per specifications with Breaking capacity not less than 10 KA. | — | — | — | 7,750 | |
| — | 1.00 | — | — | ||
| Supplying, fixing ,testing & commissioning Automatic operation street light timing switch box having lighting control (on-off) through astronomical calculation and pre-wired with suitable size of contactors, copper conductor etc. at specified locations as per specification attached and Similar to model no 04764 of LEGRAND make or similar of Siemens/ABB. | — | — | — | 25,804 | |
| — | 2.00 | — | — | ||
| Supply and testing of 1.5HP submersible mono block pump discharge 4 LPS, Head 18 Mtrs. Head range 7/23 Mtrs of reputed make and as per tech spec. Make: Crompton/Greaves/KSR/Kirloskar/ CRI/Texmo/ KSB or similar. | — | — | — | 23,138 | |
| — | 2.00 | — | — | ||
| Supply of single phase submersible pump set suitable for 100 mm bore well 2 HP, Head 48 Mtrs , discharge 110 LPM motor and pump body shall be of stainless steel with suitable starter (with Ammeter & Voltmeter) Make Crompton/Greaves/KSR/ Kirloskar/CRI/Texmo/ KSB or similar. | — | — | — | 26,432 | |
| — | 200.00 | — | — | ||
| Supply and drawing of PVC insulated 3 core sheathed Flat copper submersible cable 1100 volt grade conf. to IS: 694/1990 with latest amendments, size 10 sqmm. Cable should be of reputed make and as per tech. spec. | — | — | — | 81,000 | |
| — | 200.00 | — | — | ||
| Supply and drawing of PVC insulated 3 core sheathed Flat copper submersible cable 1100 volt grade conf. to IS: 694/1990 with latest amendments, size 6 sqmm. Cable should be of reputed make and as per tech. spec. | — | — | — | 37,400 | |
| — | 4.00 | — | — | ||
| Supply & Fixing ISI marked (IS : 15683 ) Portable Fire Extinguisher, CO2 type flat base including valve, discharge hose of not less than 10mm dia, min.600mm long & complete in all respects including initial fill with CO2 gas confirming to IS:307 of 1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket capacity of 4.5 kg capacity. | — | — | — | 35,488 | |
| — | 200.00 | — | — | ||
| Laying of Spun/MS/GI/HDPE pipe 100mm to 200 mm by push through method in Railway yard/below track/Road. | — | — | — | 1,05,200 | |
| — | 30.00 | — | — | ||
| Supply, fixing and connection of modular mobile charging board consting of following.1)Modular board-12M -01 nos 2)Modular Switch 1way 10A-04nos 3)5/10A multi socket - 03nos4) Twin USB Charger Upto2.1 A -1M- 01 nos 5) 12 Module GL metal board-01 nos 6) Mobile charging tray (MDF type board) (7 inch x 12 inch)- 01set as per instruction of site engineer. | — | — | — | 66,390 | |
| — | 48.00 | — | — | ||
| Design, Manufacture, Display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. (Inspection Clause: By Railway Representative). | — | — | — | 1,19,904 | |
| — | 48.00 | — | — | ||
| Erection and Installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. | — | — | — | 12,000 | |
| — | 5.00 | — | — | ||
| SITC of Bracket fan 400mm of reputed make as per requirement. | — | — | — | 7,865 | |
| — | 20.00 | — | — | ||
| Removal of existing Rail/Swage poles from station area. Rail are to be cut 0.5m below the ground level & making the ground level good by suitable cement concrete and transportation of rail pole and all accessories with fitting etc. complete from site to place located at that station by concern SSE/Elect. | — | — | — | 12,700 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
JPOforprotectionofSTCables.pdf JPO for Protection of Cables
ATTACHMENT
RBSIGNAGESPOLICYPART-1.pdf RB Signage Policy Part 1
ATTACHMENT
RBSIGNAGESPOLICYPART-2.pdf RB Signage Policy Part 2
ATTACHMENT
UpdatedGCCandACSupto11.pdf GCC with ACS upto 11
ATTACHMENT
T14TenderSpecification.pdf
ATTACHMENT
JPOforprotectionofSTCables.pdf
ATTACHMENT
RBSIGNAGESPOLICYPART-1.pdf
ATTACHMENT
RBSIGNAGESPOLICYPART-2.pdf
ATTACHMENT
UpdatedGCCandACSupto11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].