| Sl No | Description | Qty | Unit | MANI PRASAD GUPTA L4 | Ms SATISH CHAND AGARWAL L1 | M/S BIJOYA LAXMI ENTERPRISE L3 | M/S Apple constructions L2 |
|---|---|---|---|---|---|---|---|
| 1.00Schedule 'A' | |||||||
| 1.01 | S&F in repair 8 way IN and 8 way OUT DC distribution board as per existing model and type at site complete all as specified & directed. | 2 | Each | 39,790 ₹79,580 | 31,000 ₹62,000 Lowest | 33,400 ₹66,800 | 33,100 ₹66,200 |
| 2.00 | S&F in repair branch, MC 4 Male/Female connectors set compatible with module connectors with min of IP66 rating as per existing model and type at site complete all as specified and directed. | 10 | Each | 539 ₹5,390 | 450 ₹4,500 | 344 ₹3,440 | 298 ₹2,980 Lowest |
| 3.00 | Taking down of existing 50 KW invertor and transportation to nearest workshop and repair, testing, reinstallation and commissioing of 50KW Inverter complete all as specified and directed. | 4 | Each | 1,28,900 ₹5,15,600 | 1,03,500 ₹4,14,000 Lowest | 1,23,000 ₹4,92,000 | 1,24,590 ₹4,98,360 |
| 4.00 | S&F in repair of 50 KW Invertor, Max PV array open circuit Voltage 1000 Vdc, Nominal input Voltage 620 Vdc, PV input oprating voltage range 250 to 950 Vdc with IP 65 protection complete all as specified and directed. | 1 | Each | 4,14,000 ₹4,14,000 | 3,15,000 ₹3,15,000 Lowest | 3,39,000 ₹3,39,000 | 3,31,200 ₹3,31,200 |
| 5.00 | M&L for Servicing of the Sub LT Panel all as specified and directed. | 2 | Each | 34,500 ₹69,000 | 9,500 ₹19,000 Lowest | 15,560 ₹31,120 | 12,100 ₹24,200 |
| 6.00 | M&L for Servicing of the Main LT Panel all as specified and directed. | 2 | Each | 29,690 ₹59,380 | 9,500 ₹19,000 Lowest | 16,500 ₹33,000 | 12,430 ₹24,860 |
| 7.00 | S&F in repair MCCB, 125 Amp 3 Pole, Adjustable type with rotary motion for On and OFF suitable as per existing type and model all as specified and directed. | 2 | Each | 22,000 ₹44,000 | 9,500 ₹19,000 Lowest | 16,500 ₹33,000 | 14,980 ₹29,960 |
| 8.00 | S&F in repair 25 Sqmm 4 core Cable with copper conductor PVC round sheathed (flexible) industrial cable all as specified and directed. | 100 | RM | 2,190 ₹2,19,000 | 1,300 ₹1,30,000 | 1,450 ₹1,45,000 | 1,185 ₹1,18,500 Lowest |
| 9.00 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of UG cables etc and getting out in soft/ loose soil complete all as specified. | 2 | CUM | 565 ₹1,130 | 365 ₹730 | 400 ₹800 | 345 ₹690 Lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
15 Sept 2025, 6:00 pmClosed
GE 869 EWS
GE 869 EWS PIN - 913869 C/O 99 APO
REPAIR/ MAINT OF 1 MW SOLAR POWER PLANT AT LEIMAKHONG MIL STN
2025_MES_717950_2
8652/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹24,000
Yes
25 Sept 2025
18 Aug 2025
16 Sept 2025
18 Aug 2025
15 Sept 2025
2 Sept 2025
Amount
Schedule 'A'
S&F in repair 8 way IN and 8 way OUT DC distribution board as per existing model and type at site complete all as specified & directed.
S&F in repair branch, MC 4 Male/Female connectors set compatible with module connectors with min of IP66 rating as per existing model and type at site complete all as specified and directed.
Taking down of existing 50 KW invertor and transportation to nearest workshop and repair, testing, reinstallation and commissioing of 50KW Inverter complete all as specified and directed.
S&F in repair of 50 KW Invertor, Max PV array open circuit Voltage 1000 Vdc, Nominal input Voltage 620 Vdc, PV input oprating voltage range 250 to 950 Vdc with IP 65 protection complete all as specified and directed.
M&L for Servicing of the Sub LT Panel all as specified and directed.
M&L for Servicing of the Main LT Panel all as specified and directed.
S&F in repair MCCB, 125 Amp 3 Pole, Adjustable type with rotary motion for On and OFF suitable as per existing type and model all as specified and directed.
S&F in repair 25 Sqmm 4 core Cable with copper conductor PVC round sheathed (flexible) industrial cable all as specified and directed.
Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of UG cables etc and getting out in soft/ loose soil complete all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge.
S&F in repair GI tubing light grade 40mm dia for protection of cable on wall , road crossing, floor etc complete all as specified and as directed by Engr in charge.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron 25 x 4 mm strip as earthing lead by means of galvanized steel bolts, nuts check nuts and washers and other end connected with to Transformer ,DG set,Panel Board etc as directed including funnel, 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1with 8mm dia cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No 5 of MES Schedule Part I and testing complete all as specified and as directed.
Taking down of existing solar panel from it is frame/ structure and refixing after some minor repairs complete all as specified and directed.
Taking down of existing solar panel frame/ structure and refixing as directed at site for each panel complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of pole, protection of UG cable, concrete base, etc complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C1 using 20mm graded crushed stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed.
Supply & Fix in replacement digital 0 to 200 Amp meter complete all as specified.
Supply & Fix in replacement digital 0 to 500 Volt meter complete all as specified.
Supply & Fix in replacement CT coil 250/5 Amps complete all as specified
Supply & Fix in replacement of phase indicator lamp (R.Y.B) complete all as specified.
Supply & Fix in replacement of slector switch complete all as specified.
M&L for vegitiation of grass cutting all around surrounding and inside area of 1 MW Solar Power Plant, with help of sufficient man power with tools provided by the contractor wherever is required as directed. Note:- (a) Contractor will arange the manpower for cleaing 1 MW power plant with water to remove dust and other items from the top of each Solar Panel as and when needed be deemed to be included in the quoted rate. (b) Contractor will arange own conveyeance and communication system like mobile etc to maintain/cleaning the power Plant at Leimakhong Mil Stn.
S&F in repair copper lugs of size 25 Sqmm all as specified and directed.
M/S Apple constructions (BID ID -3414818)
M/S BIJOYA LAXMI ENTERPRISE (BID ID -3417182)
MANI PRASAD GUPTA (BID ID -3418342)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .