GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS/RENEWAL AND DAY TO DAY MAINTENANCE OF DAMAGED WATER SUPPLY DISTRIBUTION LINE TESTING OF WATER, LT OH LINE, LT UG CABLE, LT PANELS, STREET LIGHTS AND ALLIED WORKS AT UNIT 289 AND UNIT 729 UNDER GE (U) SECUNDERABAD
2023_MES_577022_1
GE (U)/SEC/TOKEN/68 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹80,000
Yes
11 Aug 2023
24 Jan 2023
27 Feb 2023
24 Jan 2023
20 Feb 2023
7 Feb 2023
Amount
M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Taking down old unsv Street light / flood light fittings in any position of any capacity for Repair by replacement of unsv spares ( SPD / Driver / MCBs etc ) and re-fixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items.
Notes for Item Nos 1.01 to 1.03 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store on daily basis.
M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed.
S&F of Galvanised steel wire (GI) 4mm dia including disconnecting/taking out old existing unsv GI wire complete all as specified and directed.
M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed.
Supply & replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs of capacity 200 Amps, 4 Pole, 36 KA, 415 Volt, adjustable type including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed.
All as per item No- 08 here in before but MCCB's 415 volts 4 pole 36 KA breaking capacity adjustable type of 160 Amps Capacity
All as per item No- 08 here in before but MCCB's 415 volts 3 pole 36 KA breaking capacity adjustable type of 160 Amps Capacity
All as per item No- 08 here in before but MCCB's 415 volts 4 pole 16 KA breaking capacity fixed type of 100 Amps Capacity
All as per item No- 08 here in before but MCCB's 415 volts 3 pole 16 KA breaking capacity fixed type of 100 Amps Capacity
All as per item No- 08 here in before but MCCB's 415 volts 4 pole 16 KA breaking capacity fixed type of 63 Amps Capacity
All as per item No- 08 here in before but MCCB's 415 volts 3 pole 16 KA breaking capacity fixed type of 63 Amps Capacity
Supply and fix in replacement of old MCB TPN 32 Amps 6 KA, C Curve complete all as directed
S&F MCB, SPN 10-32 Amps, 415 Volts with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
S&F MCB, SP 10-32 Amps, 415 Volts with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
supply and fix Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. complete including taking down old one. Make Swadeep Model Nature switch -02 (sensor) or equivalent as approved by GE
supply and fix Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The nature switch to be fiffed in a IP 54 SMC enclosure and protected with MCB SP 10 Amps complete including taking down old one . Make swadeep Model Nature switch -02 E (sensor) or equivalent as approved by GE.
Supply and replace contactor single pole 20/25/32 amps in street light timer box coil operating voltage 230 volt complete all as specified and directed .
Supply and replace contactor single pole 40/63 amps in street light timer box coil operating voltage 230 volt complete all as specified and directed .
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LTUG cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
All as per item No 24 here in before but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and directed.
All as per item No 26 here in before but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
All as per item No 26 here in before but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 150 Sqmm, 3.5 Core
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Pipes, Bricks, etc. of any descriptions, laying in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed.
Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 2 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No - 30 here in before but 4 Core 10 Sqmm
All as per item No - 30 here in before but 4 Core 16 Sqmm
All as per item No - 30 here in before but 4 Core 25 Sqmm
All as per item No - 30 here in before but 3.5 Core 50 Sqmm
All as per item No - 30 here in before but 3.5 Core 95 Sqmm
Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item.
Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item.
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole in one span (contains 2/4/6 runs) i.e one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
All as per item No 40 here in before but depth exc 1.5 mtr but not exc 3 mtr.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 210 x 110 x 70 mm laid across in trenches for cable protection complete all as specified and directed.
M&L filling sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 36 & 37 here-in-before), complete all as directed.
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed by Engr-in-Charge.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed
Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE / GI pipe medium duty duty of size 50 mm dia in any length including jointing materials to carry LT UG cables of size upto 95 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. Note : Pipe will be measured and paid separately under relevant items.
Cutting the existing building plinth protection/ Floor by using suitable cutter , depth and width as required for replacement of LTUG Cable of any size /any kind of pipes pipes up to 50 mm dia and making good of disturbed surface shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) to match with the adjoining surface complete all as specified and directed.
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamole base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built ( size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed.
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job.
Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed.
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying One Coats of Synthetic Enamel Paint (First quality) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, fixing to wall/pole, complete all as specified and directed. Note : (i) Make of Street light fittings and LED's used should be as per PS. (ii) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers. (iii) Surge protection of the drive should be 10 KV
All as per item No-63 here in before but 60 watts.
All as per item No-63 here in before but 70/72 watts.
All as per item No-63 here in before but 100 watts.
All as per item No-63 here in before but 120 watts.
All as per item No-63 here in before but 150 watts.
All as per item No-63 here in before but 200 watts.
S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 120 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole complete all as specified and directed. Note : (i) Make of Street light fittings and LED's used should be as per PS. (ii) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (iii) Surge protection of the driver should be 10 KV
All as per item No-69 here in before but 150 watts.
All as per item No-69 here in before but 200 watts.
Supply, fixing, connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X35/40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. Make:- PHILIPS Cat Part No BGP161 LED2500/NW PSU 220-240V 7043 IN or CG MODEL NO LPTO 40 CDL/ Surya model lP07 501-XXX-57-CL / Havells Cat No. RUBYPT35WLED757PSYMTOPC or Wipro cat No.LP07-501-XXX-57-CL as approved by GE..
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 60 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 70/72 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 90 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 100/110/120 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 100 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 120 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 150 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similer wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS crtified suitable for 200 watts LED flood light fittings of any make complete all as specified and directed.
Supply and fixing steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified.
S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed.
All as per item No-83 here in before but of size 6 Sqmm complete all as specified and directed.
S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 300 x 200 x 1055 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed.
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
S&F On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 100 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
S&F On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
Supply only of aluminium cable lugs of following sizes :-
16 to 25 Sqmm Size
35 to 50 Sqmm Size
70 to 95 Sqmm Size
120 to 150 Sqmm Size
S&F MCCB box FACTORY FABRICATED Powder coated Suitable for fixing at WALL including two set of clamps comprisinf with the following i) MCCB 63 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK.
S&F MCCB box FACTORY FABRICATED Powder coated Suitable for fixing at WALL including two set of clamps comprisinf with the following i) MCCB 100 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK.
S&F MCCB box FACTORY FABRICATED Powder coated Suitable for fixing at WALL including two set of clamps comprisinf with the following i) MCCB 125 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK.
Supply and fix on wall with necessary arrangements busbar chamber 100 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rate is deemed to be inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
Dismentling of damage / broken coping of PCC/steel pole of any size anf and removing the debries from site complete all as specified and directed
Supply and fixing lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 / 11 m SP-55 Steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed
Dismantling LT steel tubuler pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheated weatherproof 3 X single core cable for electrical connection and refixing the fitting after repair to its original/New location or as directed by engr-in-charge.(connecting wire will be measured and paid separately only)
Supply anfd fix locally available Acrylic glob light best quality clear with and including LED bulb 9 watt of 200 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one.
Supply anfd fix locally available Acrylic glob light best quality clear with and including LED bulb 9 watt of 300 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one.
S&F LED High Bay light 90 W lumanaries with with high luminous efficacy,IP 65 protected, front toughened glass with discrete high lumen LED along with Reflector including dismantling of old unserviceable fitting all accessories complete all as directed. Make - Surya Cat Ref: SLE HB 90 W COMET AND RFHB 90 COMET or equivalent make of Philips/CROMPTON/HAVELLS/BAJAJ as approved by GE.
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduit of dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . ( USED FOR GARDEN LIGHT CONNECTION, EXCAVATION , RETUNING FILLIING ETC WILL BE MEASURED AND PAID SEPARATELY.
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 1.5 sqmm as required for connection of light fittings .
Supply, fixing, connecting and testing decorative LED Bollard light with opal diffuser and aluminium reflector of 8/9/11 watt LED including nut, bolts, washers, clamps etc as in repair complete all as specified and directed. Make:- C&S Cat Part NoLTGLCW9WLED or SURYA MODEL NO SLEBL 6W BLK800 or Havells Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0) or Wipro cat No.LB14-131-XXX-65-05 as approved by GE.
S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 2.5 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of size 0.7MX0.75Mx0.35M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(SIZE NOT LESS THAN 1.05mx0.75mx0.4m)
(a) Aluminium bas bar 300amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 200 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 02 Nos Make Legrand model no: 420018 or equivalent from Schinder/L&T/Hagar/Havells as approved by GE.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of size 1MX.75mX.35M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 Nos Make Legrand model no: 420015 or equivalent from Schinder/L&T/Hagar as approved by GE. Note : for Sl No 107 & 109 (i) All Internal connection between MCCB and Bus bar shall be connected by aluminium strip of suitable size and capacity. (II) All MCCB to be connected with both side Spreader Link. The rate shall deemed to be include in the item rate
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50 X 50 X 6 mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–(SIZE NOT LESS THAN 1.05 m x 1.25 m x 0.4 m) (a) Aluminium bas bar 200 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 125 Amps, 415 volt,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar as IN COMING - 01 Nos. Make - Legrand model no: 420015 or equivalent from Schinder/ L&T/ Hagar/ Havells/C&S as approved by GE.
Repair/rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation,cutting of hard standing , returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 111 here in before but for GI tubing 40 mm bore to 50 mm bore
All as per item No 111 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine compaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 114 here in before but for GI tubing 40 mm bore to 50 mm bore.
Attending compaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION ( MARRIED / OTM/ single / multi story building ) , IDENTIFY THE FAULTS including rectification by taking down of existing GI/PPR tubing up to 80 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site TO RESTORE WATER SUPPLY complete all as specified and directed.
Notes for Sl item No 111 to 116 :- (a) The contractor will be alloted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
Notes for Sl item No 111 to 116 (Contd.....):- (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work above 1 CUM mesured and paid separately under relivent items . j) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. (k) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Rectification of lekages in pumping /delivery lines(CI/DI/PPR/MS) of size 80 mm to 100 mm at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints, filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and Lead joint , necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
Rectification of lekages in pumping /delivery lines(MS/CI/DI/PPR) of size 150 mm to 400 mm at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads by taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft&hard soil/rock of any depth by using necessary T&P(Excavator/hammer drill)as per the requirement , De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/tail peaces,any type of gasket , welding work etc as required to arrest the leakages completely and making joints,filling the trenches , site clearences and PCC at the top portion as required complete all as specified and as directed. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation exceeding 2 CUM and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
M&L for attending break down of water supply pipe line at Military area / Military Roads /civil Roads /PWD Roads /Cantt board roads and repair s to CI/DI/PPR/MS water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil , PCC,RCC, hard rock etc by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed including making good of disturbed surfaces. Note:- (i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'. (ii) Excavation and PCC will be measured and paid separately under relivent items. (iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate. (iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Notes for item No 121.01 to 121.06 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Notes for item No 123.01 to 123.06 :- (a) Excavation and Earth work shall be measured and paid separately. (b) Requisite fittings shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:- Note : Requisite fittings shall be measured and paid separately.
15 mm dia
20 mm dia
25 mm dia
Taking up or down PPR pipe and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
25 to 32 mm dia
50 mm dia
110 mm dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
25 to 32 mm dia
63 mm dia
110 mm dia
Notes for item No 126.01 to 126.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
25 to 32 mm dia
63 mm dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings laid in trenches of following sizes including all fittings.
25 to 32 mm dia
63 mm dia
110 mm dia
Notes for item No 128.01 to 128.03 :- (a) Excavation and Earth work shall be measured and paid separately. (b) Requisite fittings shall be measured and paid separately.
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes including all fittings. Note : Requisite fittings shall be measured and paid separately.
25 to 32 mm dia
63 mm dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Refixing of old CI/DI/MS Pipe and connection after cleaning in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Notes for item No 131.01 to 131.04 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Quoted rate is deemed to be inclusive of Push on Joints / D-Joints as required (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
100 mm Dia
150 mm Dia
200 mm Dia
Notes for item No 132.01 to 132.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Elbow
Hex Nipple
All as per item No 134 here in before but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Reducer Elbow 20 x 15 mm
Elbow
Hex Nipple
All as per`item No 134 here in before but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Elbow
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
Hex Nipple
All as per item No 134 here in before but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40 x 25 mm
Nipple 75mm Long
Elbow
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Hex Nipple
All as per item No 134 here in before but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 50mm x 40mm.
Reducer 50mm x 25mm.
Elbow
Hex Nipple
Supply and fixing PP-R Pipe fittings and accessories 25 to 32 mm bore, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Reducer Socket 32 x 25 mm
Socket
All equal Tee
Union
Gate Valve
All as item No 139 here in before but 63 mm bore :-
Reducer Socket 63 x 32 mm
Socket
All equal Tee
Reducer Tee 63 x 63 x 32 mm
Union
Gate Valve
All as item No 139 here in before but 110 mm bore :-
Socket
All equal Tee
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for Arresting leakages of sluice valves by replacing Gland packing, gland bush, gland falange, nutbolts, gasket, packing material as required after dismantling in existing position including testing on completion complete all as specified and directed for the following sizes:- Note: Quoted rate is deemed to be inclusive of the materials mentioned above like Gland packing, gland bush, gland falange, nutbolts, gasket, packing materia etc as required to arrest the leakages
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F CI / DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 145 here in before but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate is deemed to be inclusive of cutting of any kind of pipes and all items as required for fixing and proper functioning of Joints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
150 mm Dia
200 mm Dia
Sypply and fixing in replacement of DI D/F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves( Sluice valves Non RAISING TYPE ) with body bonnet of ductile cast iron of grade GGG-40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade quiality and Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimention as per BS 5163-89/IS 14846-2000/DIN 3202 F 4. and Valves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials ( Gasket , Nutbolts ets) connecting and testing complete all as specified and directed. Note : OLD SERVICEABLE VALVES TO BE DEPOSITED TO the DEPARTMENT store FOR FURTHER USE as directed by Engr-In-Charge)
150 mm Dia
200 mm Dia
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
M&L for Construction of new PCC solid Masonry valve chamber of size 1000 X 1000 X 1000 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 159 mm thick 159 mm wide off sets around over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 159 mm below GL externally & top of floor including excavation earth work in hard/Dense soil 5 mm thick MS sheet cover fixed on 59 mm X 59 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 59 m etc complete all as specified and directed.
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, TO CROSS WATER PIPE LINE UP TO 200 mm dia in any length including jointing materials and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed INCLUDING MAKING GOOD OF DISTURBED SURFACES. Note : Pipe will be measured and paid separately under relevant items.
Supply and lay Pipes MS black ERW Steel including specials having nominal dia 80 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls /ducts complete all as specified and directed. Note: Quoted rate is deemed to be inclusive of supply and fixing of flange of suitable size as required , bends welding and cutting etc as required for fixing of pipe .
All as per Item No. 155 here in before but for 100 mm dia
M&L Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Side Wall of Cable Duct, etc., complete all as specified and as directed.
Supply and replace single phase preventor cum low level water guard suitable for 4 to 7.5 HP submersible pump set complete all as directed by Engineer-in-Charge.
Supply and replace DOL starter suitable for 5/ 7.5 HP motor, 5.5 KW & relay max range 20-32 Amps for submersible pump set of 3 phase including necessary internal wiring with suitable copper wire including testing and commissioning complete all as directed by Engineer-in-Charge. Make L&T cat part No CS90947 or equivalent of Havells /CG as approved by GE.
Taking out unserviceable GI socket from 50 mm column pipe and S&F new GI socket 50mm (ISI marked) long type, heavy duty suitable for the column pipe complete all as directed by Engineer-in-Charge.
Taking out unserviceable GI socket from 40 mm column pipe and S&F new GI socket 40mm (ISI marked) long type, heavy duty suitable for the column pipe complete all as directed by Engineer-in-Charge.
Cutting the existing damaged threading of GI column pipe 50 mm dia and re-threading on lathe machine complete all as directed by Engineer-in-Charge.
Cutting the existing damaged threading of GI column pipe 40 mm dia and re-threading on lathe machine complete all as directed by Engineer-in-Charge.
Removing old unserviceable column pipe as obtained from lowering of submersible pump set and S&F new GI column pipe 50mm dia, heavy duty, ISI marked, including fittings (Long socket), both ends machine threaded with long threaded socket complete all as directed by Engr-in-Charge.
Removing old unserviceable column pipe as obtained from lowering of submersible pump set and S&F new GI column pipe 40 mm dia, heavy duty, ISI marked, including fittings (Long socket), both ends machine threaded with long threaded socket complete all as directed by Engr-in-Charge
Supply & fixing HDPE heavy duty coloumn pipe in Bore well internal dia 50mm PN 16kq/Sqmm including all necessary fittings and fixtures as requited for fixing with submerceable motor Complete all as specified and directed. Note: Quoted rate is deemed to be inclusive of fixing of pipe with submerceable motor and lowring in existing bore well
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 2.5 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 4.0 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
M&L for heavy duty PVC casing pipe of size 150 mm for bore well complete all specified and directed.
S&F Borewell casing cover 200 to 300 mm
Supply & fix steel wire rope anti corrosion (SS) of cage 6 mm thickness for fixing submersible pumps including necessary nuts, bolts & clamps all as specified and directed by Engineer-in-charge.
Core cutting / drilling of Bldg Roof / Wall for passing of GI Pipe up to 40 mm dia including necessary mechinaries complete all as specified and directed
M&L for flushing of existing borewells of any size upto 150 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well upto 450 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid seperetely.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 5 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well above 450 feet and upto 750 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid separately.
M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :-
Submersible Motor upto and including 5 HP.
Submersible Motor above 5 HP up to 10 HP.
Supply only the following spares suitable for existing make of submersible/centrifugal pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed :-
Gun metal Impeller.
Stage casing.
SS Sleeves.
Middle bush.(LB)
Middle sleeve.
Discharge outlet.(LB)
Pump coupling.
DOL SS Sleeve.
Suction bush.
Pump Shaft
Supply only the following spares for repairs of centrifugal / monoblock pump set of up to 10 HP capacity complete all as specified and directed :-
Ball bearing
GM bush.
CI impeller.
MS pump shaft.
Gland cover.
Dismantling and strip opening the centrifugal/ monoblock pump/motor including disconnecting the suction, delivery, vacuum pipe lines and coupling for repairs to pump and refixing the same after repairs including overhauling the pump set, renewal of gasket to pump suction and delivery lines, gland packing, greasing nuts, bolts and washers, Metal Sleeves, painting ,all kind of grinding & welding work, replacement of bearing, etc as required for arresting any kind of water leakages including testing and commissioning complete all as specified and directed for the Pump 3 phase 7.5 to 10 HP capacity. Notes (i) The rate considered is inclusive of tools and plants including transportation of pump set from site to workshop and back required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease, Gland packing, nut bolts , all kind of grinding, welding work , gasket and other minor consumables. The cost of other spares for pump measured and paid separately under appropriate items. (iii) The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump not mentioned above will be considered separately under appropriate items
M&L for rewinding the centifugal/ Monoblock electric motor startor or rotor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed ofStartor Winding of Electric Motor, 7.5 to 10 HP capacity.
Supply and installation CPRI approved pump starter electric control panel board, for indoor use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 2 mm thick angle iron legs of size 50 x 50 x 5 mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX70CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA 'C' Curve 415 volts, 25Amps -02 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-02 No. (c) Single phase preventor realy type Sz% (6wire), 415 volts -01 No
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA 'C' Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No
Material labour for removing submerceable pump motor set of capacity up to 10 HP stuck in side the borewell of depth up to 200 meter by flushing the exixting borewells of any size with drilling Compressuremounted on truck at a pressure of 7 Kg/ Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till removing of the stuck motor and then clear the bore by using rod drilling using bore well drilling machine from any kind of obstruction, reinstall the motor and coloumn pipe, necessary electric connection and testing complete all as directed and specified. Note; Quoted rate is deemed to be inclusive of flushing by using suitable compressure, rod drilling for cleaning of bore well, removing the submerceable pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of coloumn pipe , casing pipe, electrical connections, testing ets as required.
Supply and fix MCB SP&N 32 Amps 10 KA C Curve . Make L&T model BB20320C / Legrand/ Havells/C&S as approved by GE.
Supply and fix MCB SP&N 25 Amps 10 KA C Curve . Make L&T model BB20325C /Legrand/ Havells/C&S as approved by GE.
Supply and fix MCB SP&N 20 Amps 10 KA C Curve . Make L&T model BB20200C /Legrand/ Havells/C&S as approved by GE.
Supply and fix MCB TP&N 20 Amps 10 KA C Curve . Make L&T model BB40200C /Legrand/ Havells/C&S as approved by GE.
Supply and fix MCB TP&N 32 Amps 10 KA C Curve . Make L&T model BB40320C /Legrand/ Havells/C&S as approved by GE.
Supply and fix MCB TP 20 Amps 10 KA C Curve . Make L&T model BB30200C /Legrand/Havells/C&S as approved by GE.
Supply and fix MCB TP 32 Amps 10 KA C Curve . Make L&T model BB30320C /Legrand/Havells/C&S as approved by GE.
Supply only Bleaching powder Grade-I, IS 1065:1989(used in drinking water), stable dry free flowing white in appearance without hard lumps and visible impurities in laminated high density polythene bags of 25 Kgs capacityof each bags. Make : ADITYA BIRLA CHEMICALS LTD (DC) /RAMCO/GRASIM/DCM
Supply only Calcium Hypochlorite calcium based high strength granular chlorine having 65 % - 70 % chlorine content packed in 45 Kgs PVC sealed container, superior quality suitable for treatment of drinking water ( Much more stable than chlorine gas, bleaching power and sodium hypochlorite) all as specified and directed. NOTE :- Approval of chemical (calcium hypochlorite) shall be given after verifaction of test certificates of chemical of various manufactures and other factores like chemical and safety and health hazard aspects of usage of chlorination . Make of the chlorination of chemical must be stated in production of certificate duly certified by govt laboratory conforming compliance of specification suitable for drinking water with a declartion from the laboratory that from the technical strengh stability health safety and operation point of view , this product is used for drinking water applications for consumption by humans and the brand/make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory. Traditional means of chemical shall be used subject to fulfil the parameters specified in the manual on water supply and treatment (Third edition May 1999) issued by Central Public Health and Environmental Engineering Organisation (CPHEEO), Ministry of Urban Development New Delhi. The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS
Notes for item No 194 to 195 :- (i) Contractor shall supply material as per monthly requirement basis in bags/containers as and when directed by Engr-in-Charge at various installation of AGE E/M No-II. (ii) Quoted rate is deemed to be inclusive of complete labour and transportation for the materials at various installations of AGE E/M No II with out any extra cost.
Servicening / periodical checking of Starter panel board suitable for 5 HP to 10 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Servicing of Submersible pump motor set of capacity up to 10 HP complete all as directed
Attending Breakdown of any capacity any type ( Submerceable, Monoblock, Cetrifugal etc) of PUMP SETS , Starter panel by Technitian and Helper for checking all parts and rectify the faults and give reports to concern JE as directed by Engr-In-Charge Note : All spare parts to be replaced and paid against respective items.
Arresting lekages from pumps of motor capacity 05 HP to 10 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Quoted rate is deemed to be inclusive of all items as requiree to arrest the leakages from pumps
M&L for Painting of centrigfugal pumpset of capacity up to 10 HP complete in all arespect including ite inlet and outlets pipes , valves , base frame complete with synthetic enamelled spray painting complete all as directed
S&F, connecting and testing in repair of Cast Iron foot Valves flanged ends swing type operation 50 mm dia with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
Testing of water samples for bacteriological and chemical analysis as mentioned below from borewells viz Unit 729, Unit 289 & Pump House Old Assay Line, BMH Tank and certain other areas.complete all as specified and directed. Note: Testing of water for meter o water for Testing of water and Treated water in Each PH consider as One Job (a) Sample of Water for the above media test are to collected in transparent container/ Jar/bottle separately for each test against each pump house. (Hyginenically clean bottles). 9b0 Sample of water to be collected shall be forwarded to Govt Lab.
JAMDAGNI ENGG WORKS
sree venkateswara enterprises
Srinivash Engineers
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .