| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹13.6 L+₹1.7 L (14.0%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | L3₹15.4 L+₹3.5 L (28.9%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance Rejected being other than L1 | |
| 4 | L4₹15.5 L+₹3.5 L (29.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than L1 | |
| 5 | L5₹16.0 L+₹4.0 L (33.8%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than L1 |
Tender Value
₹15.8 L
EMD Value
₹31,600
Closing Date
5 Mar 2024, 6:00 pmClosed
GE I CG RATNAGIRI
Military Engineer Service Garrison Engineer I CG Ratnagiri SLUY Shed Plot, W19 23 MIDC Mirjole Ratnagiri 415 639
PROVISION OF SPLIT AC AND PROVISION OF CASSETTE AC AT ICGS AND ICGAS RATANGIRI
2024_MES_642224_1
8205/E8
Open Tender
Civil Works
Item Rate
90 days
Ratnagiri
As per tender documents
8 documents required · 8 mandatory
₹500
GE I CG RATNAGIRI
₹31,600
Yes
6 Apr 2024
13 Feb 2024
7 Mar 2024
13 Feb 2024
5 Mar 2024
27 Feb 2024
Amount
Supply , fixing and installation Split Air conditioner electric driven, single phase of capacity 2 TR BEE 4 star rated, inverter type complete 4 star rating Inverter Split AC with Antibacterial Coating Dust Filter Copper Condenser, Antimicrobial Protection, wide operating voltage range 110v to 285 v necessary connection including drain pipe, hole in wall and water outlet pipe as required at site, testing and installation all as specified and directed bby Engr-in-charge.
Supply , fixing and installation Split Air conditioner electric driven, single phase of capacity 1.5 TR BEE 5 star rated, inverter type complete 5 star rating Inverter Split AC with Antibacterial Coating Dust Filter Copper Condenser, Antimicrobial Protection, wide operating voltage range 110v to 285 v necessary connection including drain pipe, hole in wall and water outlet pipe as required at site, testing and installation all as specified and directed by Engr-in-charge.
Supply and fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with 4-6 sec. Initial delay accuracy of +2.5% and of capacity 15 A.
Supply and fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V-285 V with output voltage stabilized at 230V with 3mts+/-20sec. ITDS accuracy of + 2.5% and of capacity 15 A.
S&F Sheet Encloser box Double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps.
Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 3 single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through in and including PVC conduit concealed in walls/ roof/ floors all as directed by Engineer in Charge. Note: (i) 3 wires of 6 Sqmm and PVC conduit shall be measured as one unit. (for 2 ton AC)
Sub main wiring power/circuit using PVC insulated unsheathed FRLS, stranded copper conductor cable 3 single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through in and including PVC conduit concealed in walls/ roof/ floors all as directed by Engineer in Charge. Note: (i) 3 wires of 4 Sqmm and PVC conduit shall be measured as one unit. (for 1.5 ton AC)
S&F MCB SPN 32 to 60 Amps 240 volts 10 KA rating.
Supply Installation testing and commissioning of 3.0 TR Cassette Air Conditioning units having indoor Cooling unit & out-door cooling unit with one cordless remote, microprocessor for each units etc.The unit shall be precharged with refrigerant.Including. i) Interconnecting regrigerant pipe work for following sizes 15.9mm,9.5mm.with closed cell elastometic nitrile rubber tubular insulation (13mm thick) between each set of main panel/DB to outdoor unit & outdoor to indoor unit complete all as specified and directed by Engineer-in-charge. ii)Rigid PVC piping confirming to IS complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete all as specified and directed of following size:-25mm. iii)MS Stand for outdoor unit. iv)Supplying & Charging of Extra refrigerant including leakage testing & Pressure holding of the system etc. complete as reqd. v) S&F Power cum control cable of 5 core x 6 sqmm copper cable in PVC/UPVC conduit between indore and outdoor unit & to outdoor.
LAXMI ENTERPRISES
M/S DUBAL CONSTRUCTION
K M SUBHANAIAH
AIRDOT ENGINEERING
Modern Engineering Co
M/S P S BABU
M/S jvsr constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .