Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹10.1 L+₹1.5 L (16.8%)Rejected-Finance SUDHA RANI VILA GROUND FLOOR 65 NASKAR PARA ROAD KOLKATA 700041 | KOLKATA | KOLKATA | WEST BENGAL | 700041 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹11.2 L+₹2.5 L (29.0%)Rejected-Finance NALIAPOOL BAZAR ROAD NEAR GABHARUPATHAR RAILWAY COLONY DIBRUGARH DIST ASSAM 786001 | DIBRUGARH | DIBRUGARH | ASSAM | 786001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹11.7 L+₹3.0 L (34.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹11.9 L+₹3.2 L (37.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 Jul 2020, 9:00 amClosed
GE (AF) Mohanbari
GE (AF) Mohanbari
REPAIR AND MAINTENANCE OF PERIMETER LIGHT, STREET LIGHT AND MISC E/M CONNECTED WORKS AT AF STN MOHANBARI UNDER GE (AF) MOHANBARI.
2020_MES_353732_1
NIT No . 8001/218/01/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AFS Mohanbari
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹20,000
Yes
10 Oct 2020
18 Jun 2020
17 Jul 2020
18 Jun 2020
15 Jul 2020
3 Jul 2020
Amount
Taking down unserviceable Sodium Vapour/Metal Halide lamp/LED fittings of any watt and any type from existing position on pole/wall/tower checking its serviceability for reuse/repair or replacement of unserieable items such as electronic ignitor,ballast, capacitor, porcelain holder, HPSV/MH lamps of any watts to make it fully functional, internal wiring in all respect complete and keeping unserviceable fittings in safe custody for re-use in the work complete all as specified and directed by Engineer-in-charge. Note:- (i) Spares required for repairs and replacement shall be measured and paid seperately under respective item. (ii) Quoted rate shall deemed inclusive of labour element for repair and replacement of spares. (iii) Inventory of all defective parts required to be replaced will be recorded in a separate register alongwith pole No & location / area and type of light fittings before replacement duly signed by JE, Engineer-In-Charge & contractor and the same shall be produced as and when desired for verification.
Supply only Electronic Ignitor of non integral HPSV fittings suitable for of 70 watts to 250 watts complete all as specified and directed by Engineer-in-charge.
Supply only Electronic Ignitor SI for Metal Halide fittings of any Wattage complete all as specified and directed by Engineer-in-charge.
Supply only ballast copper wounded suitable for HPSV/MH fittings 250 watts and conforming to IS : 6616-1982 (latest) complete all as specified and directed by Engineer-in-charge.
Supply only ballast copper wounded suitable for HPSV/MH fittings 150 watts and conforming to IS : 6616-1982 (latest) complete all as specified and directed by Engineer-in-charge.
Supply only ballast copper wounded suitable for HPSV fittings 70 watts and conforming to IS : 6616-1982 (latest) complete all as specified and directed by Engineer-in-charge.
Supply only ballast copper wounded suitable for Metal Halide fittings 400 watts 240 Volts 50 hz complete all as specified and directed by Engineer-in-charge.
Supply only capacitor suitable for HPSV fittings 150/250 watts SV light (33 MFD) complete all as specified and directed by Engineer-in-charge.
Supply only porcelain lamp holder screw type suitable for HPSV lamps any watts complete all as specified and directed by Engineer-in-charge.
Supply only 250 watt HPSV lamp ISI marked conforming to IS:9974(Pt. 1)/1981 and IS: 9974 (Pt. 2)/1981, tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply complete all as specified and directed by Engineer-in-charge.
Supply only 150 watt HPSV lamp ISI marked conforming to IS:9974(Pt. 1)/1981 and IS: 9974 (Pt. 2)/1981, tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply complete all as specified and directed by Engineer-in-charge.
Supply only 70 watt HPSV lamp ISI marked conforming to IS:9974(Pt. 1)/1981 and IS: 9974 (Pt. 2)/1981, tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply complete all as specified and directed by Engineer-in-charge.
Supply only Metal Halide lamp 250 Watt, minimum output, 23000 lumen high intensity discharge lamp 220/240 Volts complete all as specified and directed by Engineer-in-charge.
Supply only Metal Halide lamp 150 Watt, minimum output, 23000 lumen high intensity discharge lamp 220/240 Volts complete all as specified and directed by Engineer-in-charge.
Supply only Metal Halide lamp 400 Watt, minimum output, 23000 lumen high intensity discharge lamp 220/240 Volts complete all as specified and directed by Engineer-in-charge.
Supply only LED outdoor driver 45 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge.
Supply only LED outdoor driver 75 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge.
Supply only LED outdoor driver 100 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge.
Supply only LED outdoor driver 150 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge.
Supply only surge protection devices compatible with industrial & outdoor LED voltage 5 KV fixtures upto rated power of 75 W for suitable LED fittings complete all as specified and directed by Engineer-in-charge.
Supply only surge protection devices compatible with industrial & outdoor LED voltage 5 KV fixtures rated power above 75 W and upto 150 W for suitable LED fittings complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repair loop in loop out Polycarbonate Junction box in accordance with IEC 60670-22 of size 200 mm x 160 mm x 98 mm , with front openable hinged cover and locking arrangements with IP 65 degree of protection complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including provision of connector for connection of cables complete all as specified and directed by Engineer-in-charge. Make: Hensel, cat no K9250 or equivalent of Sintex Industries Ltd/ C&S Electric Ltd
Cutting/Trimming and removing of tree branches of any girth all around the overhead lines upto 2 metres from the overhead lines and removing the cut branches from worksite outside MD land to any distance.complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs MCB C-series, four pole of capacity 40 to 63 amps, 240 volts with 10 kA breaking capacity In accordance with IS/IEC 60898-1 including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs MCB C-series, single pole of capacity 6 to 32 amps, 240 volts with 10 kA breaking capacity In accordance with IS/IEC 60898-1 including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair Integral metal halide luminaire 1x250 watt including 1x250 watt metal halide lamp alongwith channel, MS clamp, nuts, bolts and washers for fixing of MH fitting complete all as specified and directed by Engineer-in-charge. Make: Philips Type- MWF331 1xHPITP250W or equivalent of Wipro
Supply and fixing in repair GI bracket for street light made out of 40 mm dia GI pipe medium grade 1.5 metre in length bend in shape as required including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair GI bracket for street light made out of 25 mm dia GI pipe medium grade 1.5 metre in length bend in shape as required including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed by Engineer-in-charge.
Material and Labour for drawing one runs of PVC insulated unsheathed three core multi stranded copper conductor FRLSH cable of size 2.50 sq mm with one run of PVC insulated unsheathed three core multi stranded copper conductor FRLSH cable of size 1.50 sq mm including 20 mm dia rigid steel conduit stove enameled black welded exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs time switch type including programming of time setting complete all as specified and directed by Engineer-in-charge. Make : Legrand : AlphaRex D-21, Cat no. 412631 or equivalent of L&T/Crompton/Schneider
Supply and fixing in replacement Triple Pole Power Contactor 40 Amps 3 module 3 N/O type of contact conforming to IEC/EN 61095 complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil, making the surface plain complete all as specified and directed by Engineer-in-charge.
Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and directed by Engineer-in-charge. (Note: Punned thickness shall be measured and paid. )
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for well burnt bricks having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Material and labour for galvanized iron tubing 40 mm bore light grade with all fitting for protection of cable, laid in trenches/wall/floor including taking down existing. complete all as specified and directed by Engineer-in-charge. Note: Excavation ,earth work shall be measured and paid separately.
Disconnecting and taking out the existing unserviceable LT cable of any size, Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site complete all as specified and directed by Engineer-in-charge. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Disconnecting and taking out the existing unserviceable LT cable of any size, Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site complete all as specified and directed by Engineer-in-charge. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Supply and Fixing in repair PVC insulated multi core stranded copper Conductor cable 4 Sqmm 3 core for connection of luminaires complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 7150 lumen, system wattage 65 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 9900 lumen, system wattage 90 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing for LED flood light, epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 11000 lumen, system wattage 100 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light and removing from work site complete all as specified and directed by Engineer-in-charge.
Supply and fixing for LED flood light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 13200 lumen, system wattage 120 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light and removing from work site complete all as specified and directed by Engineer-in-charge.
Material and labour for CFL lamp 85 Watt, 500 Lumen, minimun 500 average working hours, tri-phosphor coating, high color rendering - 80+ CRI, integrated electronic ballast including taking down unserviceable light and removing from work site complete all as specified and directed by Engineer-in-charge.
R K CHAKRABORTY AND CO
HIND CONSTRUCTION
KP GHOSH AND CO
FREEZCON
M/S N K SAI TRADING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .